Tender For Soil Testing Lab Balotra Under Shyam Prashad Mukharji Yojana (Equipment)

Issued by Boards / Undertakings / PSU · Barmer, Rajasthan
Tender Value
23.65 Lakhs
Estimated cost
Bid Submission
23 Nov 2026
7 days left
EMD
47300
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Barmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Soil Testing Lab Balotra Under Shyam Prashad Mukharji Yojana (Equipment) , Ph Meter - Standard Measurement Range Of 0.00 To 14.00 Ph With A Standard Laboratory Accuracy Of ±0.01 Ph, Microprocessor Controlled, 31/2 Digit Display , Ec Meter- • Conductivity Range: Standard Meters Range From 0 To 20.00 Ms/Cm Resolution: Usually 0.01 Ms/Cm Scale. Accuracy: Typically ± 1% To ± 2% Of The Full Measurement Scale. , Micro Processor Controlled Flame Photometer- • Sodium (Na), Potassium (K), Lithium (Li), Sensitivity: Typically 0.5 To 2 Ppm (Parts Per Million) For Na, K, And Li. Accuracy: ± 2% Or Better Of Full Scale Deflection (Fsd). Reproducibility: Coefficient Of Variation 1% For Consecutive Samples. Response Time: Fast Readings, Usually Under 8 Seconds Per Sample. , Visible Spectrophotmeter Model. Visible Spectrophotometer With Ccd Detector And Halogen Light Source Ccd Allows Simultaneous Spectral Recording From380-950 Nm In Less Than 1 Second The System. No Mechanical Movement Part For Rugged Performance. The Ultra-Fast Ccd Module Is Our In-House Developed Alpha Capture.No Moving Components. User Selectable Integration Time. Wave Length Range. Wavelength Range : 340 - 950.0Nm Photometric System : Single / Split Beam/Multi Beam Grating : 600 Lines/Mm Spectral Bandwidth : 1.0Nm Detector : Ccd Array With 3648 Element Wavelength Increment : 0.1Nm Data Interface : Usb Noise Level : 0.005 A Wavelength Accuracy : 0.1Nm @ 656.1Nm Wavelength Repeatability : 0.3Nm Full Spectrum Scan Time : 0.1 Seconds Photometric Accuracy : 0.002 A @ 0.5 A External Calibration Available To User Built In Pc Specification: 8 Inch Graphic Color Touch Screen 32 Gb Memory,Wi-Fi & Usb Port Power Requirements: Ac 230 +/- 10% With Proper Ground. 50Hz, 30 Va. Standard Supply: Two Pair Of Glass Cuvette, Dust Cover, Manual, Interface Cable Or As Bid Requirement , Double Beam Atomic Absorption Spectrophotometer With Auto 8 Lamp Turret & Variable Slit Control, Automatic Gas Unit,Background Correction. System Consists Of Following (I) Fully Automated 8 Lamp Turret With Automatic Lamp Optimization, Self-Alignment & Automatic Peaking Of The Hollow Cathode Lamp Energy For Maximum Light Throughput To Ensure Optimum Accuracy. (Ii) Automatic Hollow Cathode Lamp Warm Up Of Next Element To Be Analyzed. (Iii) All Reflective Optics For Greater Light Throughput. (Iv) Automatic Setting Of Wavelength Over The Range Of 175 To 930Nm. (V) Focal Length 330 Mm, Holographic Grating 1800 Lines/Mm And Linear Reciprocal Dispersion Of 1.6 Nm/Mm. (Vi) Continuously Adjustable Slit Width From 0.1 To 2.0 Nm With Automatic Setting. (Vii) High Performance Photomultiplier Tube (Pmt) Detector Covers Full Wavelength Range. (Viii) Variable Modulation To Reduce Noise By Up To 45%. , (Ix) Coded Lamp Compatible. (X) Each Lamp Quadrants Position Is Programmed In Software To Enable Automatic Lamp Recognition. (Xi) Advanced Software Operating On The Latest Windows® Platform. (Xii) User Friendly Software & Supports Cfr 21 Part 11 Compliance. (Xiii) Calibration With Up To N Number Of Standards. Uses Linear Fit Polynomial, Linear Least Squares, Standard Additions Standards Etc. (Xiv) Guaranteed Highest Sensitivity (5 Ppm Cu Gives 0.900 Abs). (Xv) Pc Connectivity Port - Usb. (Xvi ) Flame Atomization System Pre-Mix Design With Solid Inert Ptfe Polymer Spray Chamber, Adjustable Impact Bead . Titanium Burner Head Construction. Burner Can Be Moved In All Three Dimensions To Get Best Signal (Burner Slot Beam Path Alignment). The Air Acetylene Burner Is Designed To Reduce Carbon Build Up. Nebulizer Has Platinum-Iridium Capillary And Inert Venturi For Resistance To Acid Attack (Corrosion Resistant). , (Xvii) Programmable Flame Control With Eleven Safety Interlocks With Stand Alone Control Module & Status Display & Retains The Gas Flow Rates As Per Last Run Method Used, It Provides Reproducible Results With Set Gas Flows Automatically When Changing Methods. Interlocks Monitor Air, Acetylene And Nitrous Oxide Pressure, Burner Presence, Burner Type, Liquid Trap Level, Presence Of Nebulizer And Pressure Relief Bung, Oxidant Flow, Flame Condition, Vibration In Flame Auto Changeover, Safe Extinguish And Mains Power. (Xvii) Background Correction Accessory With Deuterium (D2) Working Range Of 185-425 Nm. Ultra Fast Pulse Background Correction For Accurate Monitoring Of Transient Background Signals To 2.5 Abs. (Xix) To Operate Aas Windows Loaded Pc To Be Supplied . , Analytical Balance 220 G 0.1Mg Accuracy . Reputed Branded , Electronics Weight Balance Of Capacity 6000 Gms, Readibility 0.1 Gm, Heving Pan Size 180X195 Mm Of Stainless Steel Weighting Pan, Level Indicator, Easy To Read Lcd Display With Back Light, Calibration Facility With External Weight. , Distillation Glass Apparatus Horizontal 3 L/Hr Automatic Electrical Heating With All Safety Fearures Built In , Horizontal Shaker Machine Reciprocating Type, Stroke 20-300 Per Minute , Double Door Refrigerator Cap: 300 Ltr. , Lpg Gas Cylinder With Lpg Stove , 5.0 Kva Ups With 60 Minutes Backup Single Phase Input 180-270 V Ac, Out Put 220V +/- 5V

AI Tender Summary

OUR REF NO 58540511
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 23.65 Lakhs
LAST DATE 23-11-2026
Authority
Authority Name Rajasthan State Agricultural Marketing Board
Work Description Tender for Soil Testing Lab Balotra Under Shyam Prashad Mukharji Yojana (Equipment) , Ph Meter - Standard Measurement Range Of 0.00 To 14.00 Ph With A Standard Laboratory Accuracy Of ±0.01 Ph, Microprocessor Controlled, 31/2 Digit Display , Ec Meter- • Conductivity Range: Standard Meters Range From 0 To 20.00 Ms/Cm Resolution: Usually 0.01 Ms/Cm Scale. Accuracy: Typically ± 1% To ± 2% Of The Full Measurement Scale. , Micro Processor Controlled Flame Photometer- • Sodium (Na), Potassium (K), Lithium (Li), Sensitivity: Typically 0.5 To 2 Ppm (Parts Per Million) For Na, K, And Li. Accuracy: ± 2% Or Better Of Full Scale Deflection (Fsd). Reproducibility: Coefficient Of Variation 1% For Consecutive Samples. Response Time: Fast Readings, Usually Under 8 Seconds Per Sample. , Visible Spectrophotmeter Model. Visible Spectrophotometer With Ccd Detector And Halogen Light Source Ccd Allows Simultaneous Spectral Recording From380-950 Nm In Less Than 1 Second The System. No Mechanical Movement Part For Rugged Performance. The Ultra-Fast Ccd Module Is Our In-House Developed Alpha Capture.No Moving Components. User Selectable Integration Time. Wave Length Range. Wavelength Range : 340 - 950.0Nm Photometric System : Single / Split Beam/Multi Beam Grating : 600 Lines/Mm Spectral Bandwidth : 1.0Nm Detector : Ccd Array With 3648 Element Wavelength Increment : 0.1Nm Data Interface : Usb Noise Level : 0.005 A Wavelength Accuracy : 0.1Nm @ 656.1Nm Wavelength Repeatability : 0.3Nm Full Spectrum Scan Time : 0.1 Seconds Photometric Accuracy : 0.002 A @ 0.5 A External Calibration Available To User Built In Pc Specification: 8 Inch Graphic Color Touch Screen 32 Gb Memory,Wi-Fi & Usb Port Power Requirements: Ac 230 +/- 10% With Proper Ground. 50Hz, 30 Va. Standard Supply: Two Pair Of Glass Cuvette, Dust Cover, Manual, Interface Cable Or As Bid Requirement , Double Beam Atomic Absorption Spectrophotometer With Auto 8 Lamp Turret & Variable Slit Control, Automatic Gas Unit,Background Correction. System Consists Of Following (I) Fully Automated 8 Lamp Turret With Automatic Lamp Optimization, Self-Alignment & Automatic Peaking Of The Hollow Cathode Lamp Energy For Maximum Light Throughput To Ensure Optimum Accuracy. (Ii) Automatic Hollow Cathode Lamp Warm Up Of Next Element To Be Analyzed. (Iii) All Reflective Optics For Greater Light Throughput. (Iv) Automatic Setting Of Wavelength Over The Range Of 175 To 930Nm. (V) Focal Length 330 Mm, Holographic Grating 1800 Lines/Mm And Linear Reciprocal Dispersion Of 1.6 Nm/Mm. (Vi) Continuously Adjustable Slit Width From 0.1 To 2.0 Nm With Automatic Setting. (Vii) High Performance Photomultiplier Tube (Pmt) Detector Covers Full Wavelength Range. (Viii) Variable Modulation To Reduce Noise By Up To 45%. , (Ix) Coded Lamp Compatible. (X) Each Lamp Quadrants Position Is Programmed In Software To Enable Automatic Lamp Recognition. (Xi) Advanced Software Operating On The Latest Windows® Platform. (Xii) User Friendly Software & Supports Cfr 21 Part 11 Compliance. (Xiii) Calibration With Up To N Number Of Standards. Uses Linear Fit Polynomial, Linear Least Squares, Standard Additions Standards Etc. (Xiv) Guaranteed Highest Sensitivity (5 Ppm Cu Gives 0.900 Abs). (Xv) Pc Connectivity Port - Usb. (Xvi ) Flame Atomization System Pre-Mix Design With Solid Inert Ptfe Polymer Spray Chamber, Adjustable Impact Bead . Titanium Burner Head Construction. Burner Can Be Moved In All Three Dimensions To Get Best Signal (Burner Slot Beam Path Alignment). The Air Acetylene Burner Is Designed To Reduce Carbon Build Up. Nebulizer Has Platinum-Iridium Capillary And Inert Venturi For Resistance To Acid Attack (Corrosion Resistant). , (Xvii) Programmable Flame Control With Eleven Safety Interlocks With Stand Alone Control Module & Status Display & Retains The Gas Flow Rates As Per Last Run Method Used, It Provides Reproducible Results With Set Gas Flows Automatically When Changing Methods. Interlocks Monitor Air, Acetylene And Nitrous Oxide Pressure, Burner Presence, Burner Type, Liquid Trap Level, Presence Of Nebulizer And Pressure Relief Bung, Oxidant Flow, Flame Condition, Vibration In Flame Auto Changeover, Safe Extinguish And Mains Power. (Xvii) Background Correction Accessory With Deuterium (D2) Working Range Of 185-425 Nm. Ultra Fast Pulse Background Correction For Accurate Monitoring Of Transient Background Signals To 2.5 Abs. (Xix) To Operate Aas Windows Loaded Pc To Be Supplied . , Analytical Balance 220 G 0.1Mg Accuracy . Reputed Branded , Electronics Weight Balance Of Capacity 6000 Gms, Readibility 0.1 Gm, Heving Pan Size 180X195 Mm Of Stainless Steel Weighting Pan, Level Indicator, Easy To Read Lcd Display With Back Light, Calibration Facility With External Weight. , Distillation Glass Apparatus Horizontal 3 L/Hr Automatic Electrical Heating With All Safety Fearures Built In , Horizontal Shaker Machine Reciprocating Type, Stroke 20-300 Per Minute , Double Door Refrigerator Cap: 300 Ltr. , Lpg Gas Cylinder With Lpg Stove , 5.0 Kva Ups With 60 Minutes Backup Single Phase Input 180-270 V Ac, Out Put 220V +/- 5V
Basic Detail
Tender No NIT-05/2026-27(E-1)
Bidding Type Tender
Location
City Barmer
State Rajasthan
Key Dates
Publish Date 14 Nov 2026
Submission Date 23 Nov 2026
Open Date 25 Nov 2026
Finance
Tender Value 23.65 Lakhs
Tender Fee 500
EMD 47300
Exemption Available
Document List
76d972a7-f0d1-440e-a3f6-cbe4708fe02b.html
BOQ_1074582.xls
Document.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Nov 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

76d972a7-f0d1-440e-a3f6-cbe4708fe02b.html

xls

BOQ_1074582.xls

pdf

Document.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender