Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #58539951

Tender For Repair/ Maintenance / Rewiring Of Internal Electrification, Fittings And Fixtures Alongwith Connected Items In Domestic Area At Af Stn Suratgarh

Issued by Statutory Bodies & Commissions/Committees · Ganganagar, Rajasthan
Tender Value
50 Lakhs
Estimated cost
Bid Submission
07 Dec 2026
18 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ganganagar → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Maintenance / Rewiring Of Internal Electrification, Fittings And Fixtures Alongwith Connected Items In Domestic Area At Af Stn Suratgarh

BOQ

Name of Work:- REPAIR/ MAINT / REWIRING OF INTERNAL ELECTRIFICATION, FITTINGS AND FIXTURES ALONGWITH CONNECTED ITEMS IN DOMESTIC AREA AT AF STN SURATGARH
Sl. No. Item Description
1BOQ (REPAIR/ MAINT / REWIRING OF INTERNAL ELECTRIFICATION, FITTINGS AND FIXTURES ALONGWITH CONNECTED ITEMS IN DOMESTIC AREA AT AF STN SURATGARH)
2Attending day to day complaints lodged in complaint register at AF Stn Suratgarh Domestic area. The contractor will adhere time schedule for attending complaints as directed by Engr-in-Charge as follows: (a) Attending complaints for checking the existing electrical items for continuous electric supply including carrying out minor repairs etc as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc., Attending minor repairs such as testing, connections, fittings, nut, bolts screws etc to ceiling fan, exhaust fan (without taking down), shifting/refixing of LED light fittings, switch & socket, MCB etc, emergent complaints i.e. no light, earth leakage, short circuit, neutral break in mains/ sub mains/ internal circuits of existing electrical system of main building/ block and . required to make the system in order/ functional with insulation tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and directed by Engineer-In-Charge (this will be included in unit rate).Notes:- (i) The complaint for \\"No Light\\" shall be attended immediately/ On Priority.(ii) Contractor shall submit the complaint register alongwirth complaint slip verfied from JE E/M or Engr-in -charge.(iiI) In case daily complaints are not attended,per complaint per day penalty recovery shall be charged Rs. 200/- (iv) The contractor shall deploy a team of one electrician and one helper to report to JE E/M daily by 0930 hrs to attend complaints and general electrical maintenance as directed by JE E/M or Engr -in-Charge.(v) Proper attendance register and complaint attended register will be maint by JE E/M. (vi) The team of complaint attended will be utilised by JE E/M for attending complaints and will not be used by contractor for other maint work which are catered in the subject work. (vii) All complaints attended and general maint carried out to the satisfaction of Engr-in-Charge for 08 hours per day will be measured .
3M&L for in replacement of sub-main wiring (concealed) with two single core 4 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonry including 25 mm dia non-metallic PVC conduit fixed in wall including 4 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by Engr-in-charge.
4M&L for in replacement of sub-main wiring (concealed) with two single core 6 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonry including 25 mm dia non-metallic PVC conduit fixed in wall including 6 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by Engr-in-charge.
5M&L for in replacement of sub-main wiring (existing concealed PVC conduit) with two single core 4 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through existing PVC/steel conduit including 4 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by Engr-in-charge.
6M&L for in replacement of sub-main wiring (existing concealed PVC conduit) with two single core 6 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through existing PVC/steel conduit including 6 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by Engr-in-charge.
7M&L as in replacement of sub-main wiring (Surface) with two single core 4 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn on and including 25 mm dia non-metallic PVC conduit fixed on wall including 4 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by Engr-in-charge.
8Taking down carefully aluminum point wiring (light, fans, socket etc) complete including conduit etc and fittings such as switch, ceiling rose, light fittings, regulators, socket, etc. and making good disturbed surface of wall/floor, etc. complete all as specified and as directed.
9M & L for point wiring (concealed) complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in and including non metallic medium grade rigid PVC conduit, ISI marked, 19/20 mm dia including all accessories, concealed in walls/floors/ceilings etc by cutting chases using machine and making good the disturbed surface, with and including sunken type pressed steel / MS terminal box 1.2 mm thick bakelite laminated sheet top cover 3 mm thick/Modular boxes with cover plate and 1.5 sq mm copper earth continuity wire connected to earth dolly complete for the following complete all as specified and as directed by Engr-in-charge.
10(a) One light/fan/exhaust fan point controlled by by one switch
11(b) One bell/ buzzer point controlled by one push switch.
12(c) One switch socket outlet 3 pin 6 amp on same board.
13(d) One light point controlled by two 2-way switches, with cables
14All as per item No 8 above but 1.5 sq mm cable size and 1.5 sq mm earth continuity wire for one 3 pin socket outlet, 5 amps on Independent board.
15All as per item No 8 above but 2.5 sq mm cable size with 2.5 sq mm earth continuity wire for one 3 pin socket outlet, 15 Amps on independent board.
16All as per item No 10 above but 4 sq mm cable size with 4 sq mm earth continuity wire for one AC pointNote for Item No. 8 to 15 :- The disturbed surfaces of wall for concealing the wiring shall be make good by applying cement plaster, putty and colour wash etc matching with the existing surfaces. The rate for point wiring shall be deemed to include the cost of making good.
17M & L for point wiring (surface) complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn through and including non metallic medium grade rigid PVC conduit , ISI marked, 19/20 mm dia including all accessories on the surface of walls/floors/ceilings and making good the disturbed surface, with and including sunken type pressed steel MS terminal box and 1.2 mm thick bakelite laminated sheet top cover 3 mm thick/ Modular Boxes with cover plate and 1.5 Sq mm copper earth continuity wire connected to earth dolly complete for the following complete all as specified and as directed by Engr-in-charge.
18(a) One light/fan point controlled by one switch.
19(b) One 3 pin socket outlet 5 amps on independent board.
20(c) One bell point controlled by one bell push switch
21(d) One switch socket outlet 3 pin 6 amp on same board.
22(e) One light point controlled by 2 way switch.
23All as per item No 12 above but 2.5 sq mm cable size with 2.5 sq mm earth continuity wire for one 3 pin socket outlet, 15 Amps on independent board.
24All as per item No 12 above but 4.0 sq mm cable size with 4.0 sq mm earth continuity wire for one AC Point.
25M&L for point wiring complete with 1.5 Sqmm (existing PVC/steel conduit) FRLS PVC insulated, multi stranded, copper conductor cable unsheathed in existing concealed PVC conduit and PVC insulated copper conductor cable of size 1.5 sq mm as earth wire , connected to common earth dolly and replacement of laminated sheet cover of 3 mm thick for mounting swiches,socket,regulator suitable for mounting switches all as specified and as directed by Engr-in-charge for the following :-
26(a) One light/fan point controlled by one switch.
27(b) One bell point controlled by one bell push switch
28(c) One switch socket outlet 3 pin 6 amp on same board.
29(d ) One 3 pin socket outlet 6 amps on independent board.
30(e ) One light point controlled by 2 way switches.
31All as per item no 15 above but One 3 pin socket out let 15 Amps on independent board, with cables 2.5 Sq mm size and earth wire 2.5 sqmm.
32All as per item No 15 above but 4.0 sq mm cable size with 4.0 sq mm earth continuity wire for one AC Point.
33Supply and fixing for Switch modular type, one module single pole one way 6 Amps, 240 volts Ac suitable for modular switch boxes, all as specified and as directed.
34All as per item No 18 but switch 2 way
35Supply and fixing for socket modular type 6 Amps, 3 pin , 2 module,240 volts all as specified and as directed.
36Supply and fixing for switch modular type 16 Amps, 1 module,240 volts all as specified and as directed.
37Supply and fixing for socket modular type 6/16 Amps, 3 pin combine, 2 module,240 volts all as specified and as directed.
38Supply and fixing for bell push, modular type, 6 Amps, 1 module, 230 volts all as specified and as directed.
39Supply and fixing for 0 to 4 step Modular type 02 module electronic regulator for ceiling fan, 240 volts, 100 Watts humfree single pole, all as specified and as directed.
40Supply and fixing for door bell ding dong, AC, 230 Volts, single pole.
41Supply and fixing for switch piano flush button single pole one way 6 amp 240 volts, all as specified and as directed.
42Supply and fixing for Socket outlet, flush type 2 in 1, 3 pin, 6 amps, 240 volts, all as specified and as directed.
43Supply and fixing for switch piano flush type single pole two way 6 amps 240 volts, all as specified and as directed.
44Supply and fixing for switch piano flush button single pole one way 15/16 amp 240 volts, all as specified and as directed.
45Supply and fixing for Socket outlet 2 in 1, 3 pin, 5 and 15/16 amps, flush type, 240 volts, all as specified and as directed.
46Supply and fixing for bell push switch, single pole, one way flush type, 5 Amps, 240 volts, all as specified and as directed.
47Supply and fixing for 0-4 step piano type electronic regulator for ceiling fan 1200 mm sweep, 240 volts, 100 Watts humfree single pole, all as specified and as directed.
48M&L as in replacement for ceiling rose, surface bakelite, 65mmx 50mm, three terminals, complete all as specified and directed.
49S&F batten holder, PVC Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
50S&F in replacement of LED lights fitting 1x 20W, 220V, AC PC batten with a compact, versatile design CRI not less than 80, efficacy not less than 110 lumen per watt, IP rating 20 decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed.
51S&F in replacement of LED light fitting mirror optic type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
52S&F in replacement of LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable sizecomplete with IP 65/66 protection, complete all as specified and directed.
53S&F junction box plastic round, complete all as specified and directed.
54S&F as in replacement recess mounting back lit LED 36 watt 2x2 with color temperature 6500 k and efficacy not less than 100 lumens per watt in CRCA housing with full opal difference suitable for grid ceiling with revolutionary flicker controlled technology. complete all as specified and directed.
55Supply and fixing in replacement of round/ shape 15 watt 6500k 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with independent electronic LED drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specefied and directed.
56Supply and fix as in replacement driver for 8 to 36 Watts LED ceiling light luminaries complete all as specified and directed by Engr-in-charge.
57Supply and fixing as in replacement 1 Module cover plate with base frame.
58Supply & fixing as in replacement 3 Module cover plate with base frame , complete all as specified and directed
59Supply & fixing as in replacement 4 Module cover plate with base frame, complete all as specified and directed
60Supply & fixing as in replacement 6 Module cover plate with base frame, complete all as specified and directed
61Supply & fixing as in replacement 8 Modulecover plate with base frame complete all as specified and directed
62Supply & fixing as in replacement 12 Module cover plate with base frame complete all as specified and directed
63Supply & fixing as in replacement Hylum sheet of size 10\\"x12\\" with screws, complete all as specified and directed.
64Supply & fixing as in replacement Hylum sheet of size 9\\"x11\\" with screws, complete all as specified and directed.
65Supply & fixing as in replacement Hylum sheet of size 8\\"x5\\", with screws, complete all as specified and directed.
66Supply & fixing as in replacement Hylum sheet of size 5\\"x5\\", with screws, complete all as specified and directed.
67Taking down old U/S light fitting and Supply and fixing building security LED light fitting 35 Watt 230 V AC outdoor type with pressure die cast hosing with integrated lenses and high power LED's with efficacy not less than 110 lumens per watt. complete with IP 66 protection and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20/25 mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener complete all as specified and directed.
68Supply and fixing post top lantern LED type 20 watt, 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete
69Supply and laying as in replacement cable passing through pipe, 1100 volts grade heavy duty with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm 3 core in service connections complete all as specified and directed.
70S/F in replacement of sheet metal enclosure with socket plug top single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 amps , 240 Volts, complete all as specified and directed.
71Supply & Fixing in replacement of sheet metal enclosures Triple pole and neutral earth enclosure with a three pin and earth plug and socket complete with one triple pole MCB 32 amps, 415 volts, complete all as specified and directed.
72Supply and Fixing in replacement of Sheet metal Vertical double door DB 4 Way, 415 Volt, TPN with 200 Amps rated bus bar complete with MCCB as incoming and MCB's SP as out Going and fixed. complete all as specefied and directed.
73Supply and Fixing in replacement of Sheet metal double door DB 4 Way, 415 Volt, TPN with 200 Amps rated bus bar complete with MCCB as incoming and MCB's SP as out Going and fixed. complete all as specefied and directed.
74S & F of sheet metal enclosures for SPN DB's with double door for incorporating MCBs,IP-43 , 12 way with 200 amps rated busbar, 240 volts, as per IS-8623, including taking down old unserviceable single phase DBs, all as specified and as directed.
75S & F of sheet metal enclosures for SPN DB's with double door for incorporating MCBs,IP-43 , 8 way with 200 amps rated busbar, 240 volts, as per IS-8623, including taking down old unserviceable single phase DBs, all as specified and as directed.
76S & F of sheet metal enclosures for DB's for incorporating MCBs, ,4 way, IP-43 double door with 200 amps rated busbar,240 volts, as per IS-8623, including taking down old unserviceable DBs, all as specified and as directed.
77S & F of MCCB four poles, 100 Amps, breaking capacity 16 KA , confirming to IS-8828, 415 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc.
78S & F in replacement of MCCB four poles, 125 Amps, breaking capacity 16 KA , confirming to IS-8828, 415 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc.
79S & F in replacement of MCB TPN 40 to 63 Amps, breaking capacity 10 KA 'C' curve confirming to IS-8828, 415 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc. complete all as specified and as directed .
80S & F in replacement of MCB TP 3 poles,40 to 63 Amps, breaking capacity 10 KA 'C' curve confirming to IS-8828, 415 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc. complete all as specified and as directed .
81S & F in replacement of MCB SPN 40 to 63 amps 'C' series, breaking capacity 10 Ka, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc.
82S & F in replacement of MCB SP, 06 to 32 Amps, C series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc.
83Supply and fixing LED Bollard light 20 watt, 230 volts AC outdoor type fixing on ground to height ( 2 to 4 feet) comprising a robust die- cast/ extruded aluminium housing with epoxy powder coating, itegrated high efficiency LED module ingress protection rating of IP 65, complete with all internal wiring, earthing terminal, base plate, and heavy duty galvanized anchor foundation bolts, installed on a pre-cast/ cast in situ concrete foundation, complete all as specefied and directed by Engr-in -Charge.Note: The cost wil be inclusive of concrete foundation for bollard light
84Supply & fixig in replacement of Rigid non-metalic PVC conduit (20mmdia) exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc and laying of under ground, fixingin on the wall. complete all as specified and directed. Note: The rate will be inclsive of excavation for pipe laying
85M & L for replacement of Earthing complete with galvanised steel plate electrode, 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below nominal ground level) with top edge of the plate not less than not less than 1.5 metres below nominal ground level connected to earthing lead of 4 mm dia galvanised iron or steel wire all as shown in elcetrical plate No.3 to the earthing test point all as specified and as directed. Note :- the cost of excavation and earth work PCC pit and CI cover funnel & watering pipe, wiremesh, charcoal dust and common salt shall be deemed included in the unit rate for earthing all as specified and as directed.
86Contract Amount shall be derived after deducting the amount of Schedule of Credit in General Summary on serial page No 17 of tender documents. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58539951
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 50 Lakhs
LAST DATE 07-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maintenance / Rewiring Of Internal Electrification, Fittings And Fixtures Alongwith Connected Items In Domestic Area At Af Stn Suratgarh
Basic Detail
Tender No 8368/E8
Bidding Type Tender
Location
City Ganganagar
State Rajasthan
Key Dates
Publish Date 14 Nov 2026
Submission Date 07 Dec 2026
Open Date 09 Dec 2026
Finance
Tender Value 50 Lakhs
Tender Fee 500
EMD 1 Lakhs
Exemption Available
Document List
4ee869e6-859f-43da-ab91-3a9d8bcc794b.html
BOQ_896152.xls
Tenderdocuments8368.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Dec 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

4ee869e6-859f-43da-ab91-3a9d8bcc794b.html

xls

BOQ_896152.xls

pdf

Tenderdocuments8368.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender