Defence Statutory Bodies & Commissions/Committees Closing in 14 days TDR #58539910

Tender For Repair/Maint/Replacment Of Misc B/R Works, Periodical Services Of Shed At Varoius Technical Shed At 24 Ed Manauri

Issued by Statutory Bodies & Commissions/Committees · Prayagraj, Uttar Pradesh
Tender Value
40 Lakhs
Estimated cost
Bid Submission
05 Dec 2026
14 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Prayagraj → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint/Replacment Of Misc B/R Works, Periodical Services Of Shed At Varoius Technical Shed At 24 Ed Manauri

BOQ

Name of Work:- REPAIR/MAINT/REPLACMENT OF MISC B/R WORKS, PERIODICAL SERVICES OF SHED AT VAROIUS TECHNICAL SHED AT 24 ED MANAURI
Sl. No. Item Description
1Taking down cement plaster on brick/stone surface of wall built in cement mortar including racking out joints, hacking for key, scrubbing down with water etc
2M & L for rendering 10 mm thick on fair face of brick walls or concrete surface in CM 1:6 complete finished even and fair complete all as specified and directed.
3M & L for rendering 15 mm thick on fair face of brick walls or concrete surface in CM 1:4 complete finished even and fair complete all as specified and directed.
4M & L for rendering 5 mm thick on ceiling or concrete surface in CM 1:3 complete finished even and smooth without using extra cement all as specified and directed.
5M&L preparation of new surface and applying two coats of cement based paint over a coat of primer complete all as specified and as directed by Engr-in-Charge
6M&L for preparing new plastered surface of walls with 2 coat of Birla/Asian wall care Putty and applying two coat of oil bond distemper white or any tint over a coat of primer etc complete as specified and directed
7M & L for preparation of old plastered surface of wall, ceiling complete removal of existing treatment and washing, rubbing down and stopping of distempered and painted surfaces complete all as specified and directed.
8M&L applying 1mm thick wall care putty on walls and after drying the surfaces sand the putty smooth before painting complete all as specified and directed.
9M&L applying 1mm thick wall care putty on ceilings and after drying the surfaces sand the putty smooth before painting complete all as specified and directed.
10M & L for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/ltr and UV resistance as per IS 15489:2004, alkali & fungal reistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon aditives at 1.43 ltr/10sqm over and including priming coat of exterior primer applied at 0.90ltr/10sqm all as specified and directed by Engineer-in-Charge.
11M & L for applying two coat of oil bound distemper on ceiling including one coat of primer complete all as specified & directed by Engr-in-Charge
12M & L for preparation of walls and applying one coat of 100% premium acrylic emulsion paint having VOC less than 25gm/ltr and UV resistance as per IS 15489:2004, alkali & fungal reistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon aditives at 1.43 ltr/20sqm all as specified and directed.
13M & L for preparation of old plastered surface of wall, complete removal of existing treatment and washing, rubbing down and stopping of distempered and painted surfaces and applying two coats of cement based paint incl. one coat of primer complete all as specified & directed by Engineer-in-Charge.
14M&L for preparation of old surface and applying one coat of cement based paint complete all as specified and as directed by Engr-in-Charge.
15M & L for preparation of old plastered surface of wall, complete removal of existing treatment and washing, rubbing down and stopping of distempered and painted surfaces and applying two coats of Oil bounded distemper on walls incl. one coat of primer complete all as specified and directed by Engineer-in-Charge.
16M & L for preparation of old surface and applying one coat of Oil bound distemper on walls over a coat of primer complete all as specified and as directed by Engr-in-Charge.
17M & L for preparation of old ceiling surface and applying one coat of oil bound distemper complete all as specified & directed by Engr-in-Charge
18M & L for preparation of old plastered surface of walls including cornices and apply one coat of white wash complete all as specified and as directed by Engr-in-Charge.
19M&L for preparation of old surfaces of ceiling including cornices and apply one coat of white wash complete all as specified and directed by Engineer-in-Charge.
20M & L for preparation of old wooden surface exceeding 10Cm width or girth and apply one coat of synthetic enamel paint complete all as specified and as directed by Engr-in-Charge.
21M & L for preparation of old steel surface exceeding 10Cm width or girth and apply one coat of synthetic enamel paint complete all as specified and as directed by Engr-in-Charge.
22Dismantling floor, hearth or wall tilling including cement mortar bedding(but not backing), and rubbish off premises etc complete all as specified and directed by Eng-in-Charge.
23M & L coloured non-skid ceramic tiles joint free ceramic tiles 7 to 8 mm thick( square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed in cement mortar 1:6 complete all as specified and directed by Eng-in-Charge.
24M&L coloured glazed ceramic tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick/300mm x 200mm x 6to7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match over 10 mm thick backing coat in cement mortar 1:3 complete all as specified and directed by Eng-in-Charge.
25Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15cm thickness complete all as specified and directed by Eng-in-Charge..
26M&L for 100 mm thick PCC1:2:4 type B-2 using 40mm graded stone aggregate as in floor etc including necessary use and waste of formwork complete all as specified and directed by Engr-in-charge.
27M&L for PCC1:3:6 type C-2 using 40mm graded stone aggregate as in sub base to floor etc complete all as specified and directed by Engr-in-charge.
28M & L for 40 mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in floor finished even and smooth with using extra cement complete all as specified and directed by Engineer-in-Charge.
29M&L providing Chequered cement concrete tiles 25cm x 25cm x 20-22mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment laid over and including screed bed or bedding layer 20 mm thick in cm 1:6 as in floors complete all as specified and directed.
30M&L 75mm thick PCC (1:2;4) type B-1 using 20mm graded coarse aggt in plinth protection laid in alternate bays and joint filled with bituminious mastic and like including neccesry form workcomplete all as specified and directed.
31Dismantling wall and ceiling boards (fiber, pulp, insulation etc.) any thickness, including cover fillets etc complete all as specified and directed.
32S & F grid false ceiling in GI system powder coated prelude main runner section 38 x 24 x 0.40mm, cross 'T' 28 x 24 x 0.40mm, wall angle 24 x 24 x 0.40mm and including providing and fixing 4mm thick non asbestos fibre fire resistant cement building board/designer E-Board with all finishes size 595 x 595mm fixed in ceiling frame work with all necessary hanging washers, expansion holding fasteners etc for securing framework to ceiling wherever required complete all as specified and directed.
33S & F 12 mm thick gypsum plaster board flame proof conforming to IS-2095 1982 to fix as suspended celling with on step and including frame consisting perimeter channe I 20X27X30.5 mm intermediate channel 45 (WEB) X 1. 5 ( flange ) X 0.9 mm @ 1.22 M C/C with ceiling angle 2 5 X10X0.5 MM fixed to soffit with GI cleat and steel expansion fastner , celing section 51.5 ( Knurled web X 26 ( flange) with lips of 10.5 mm X 0.5mm @ 610 mm C/C nec clip , screw , nylon sleeves etc complete and apply two coats of oil bound distemper over a coat of 1mm thick putty on celling over preparation surface complete all as specified and directed.
34Taking down rolling shutter of size not exceeding 10 Sqm each from any position, any location including fittings and fixtures. Repairing / Replacing of unserviceable components and re-fixing on same opening in its original position after complete overhauling, greasing and oiling for smooth function and apply one coat of synthetic enamel paint complete all as specified & directed by Engineer-in-Charge.Note: Components/Parts replaced under this item shall be measured & paid separately as supply only under respective items.
35All as per serial Item No. 36 above but area of each rolling shutter exceeding 10 Sqm each complete as directed by Engineer-in-Charge.
36All as per serial Item No. 36 above but complete work without taking down of rolling shutter complete as directed by Engineer-in-Charge.
37All as per serial Item No. 37 above but complete work without taking down of rolling shutter complete as directed by Engineer-in-Charge.
38Supply Only MS cranked handles for operating gear operated rolling shutters made with hardened mild steel complete all as specified & directed by Engineer-in-Charge.
39Supply Only spindle/ rails of rolling shutters complete as directed by Engineer-in-Charge.
40Supply Only steel helical wires or flat spiral spring for rolling shutters to pull out the shutters including proper greasing for smooth movements/ functions complete as directed by Engineer-in-Charge.
41Supply & Fixing in replacement 0.8 mm thick Plain black mild steel sheeting for cover hood of rolling shutter made channel or semi round shape including twp coats of synthetic enamel pain over one coat of red oxide primer Internal or External surface complete as directed by Engineer-in-Charge.
42Supply Only 40mm bore MS pipe for shaft of rolling shutter as per length required at site complete all as specified & directed by Engineer-in-Charge.
43Supply Only MS pulley / wheel made with flat iron 25x 6 mm of 160mm dia for revolving of rolling shutter in shaft complete as directed by Engineer-in-Charge..
44Repair to locking plate/ locking arrangement by welding and providing missing part with new material using new nuts and bolts with locking arrangement for rolling shutter complete as directed by Engineer-in-Charge.
45Supply & Fixed in replacement in position steel rolling shutters having 1.25mm thick of laths, without ball bearing, including top hood cover, anchoring rod, hasp and staple, push pull or manual type including one coat of red oxide primer fixed in position complete as directed by Engineer-in-Charge.
46Supply & Fixed in replacement in position steel rolling shutters having 1.25mm thick of laths, without ball bearing, including top hood cover, anchoring rod, hasp and staple, gear operated type with bevel gear box and crank handle including one coat of red oxide primer fixed in position complete as directed by Engineer-in-Charge.
47Supply and fixed in replacement safety lever locks mild steel with 4 levers for rolling shutters approved/ best quality complete as directed by Engineer-in-Charge.
48Supply and fixed in replacement Ball Bearing for rolling shutter to match the existing complete as directed by Engineer-in-Charge.
49Supply & Fixed in replacement in position gear box assembly complete suitable for operating rolling shutters of size up to 25 Sqm complete as directed by Engineer-in-Charge.
50M & L for preparation of new steel surface exceeding 10 Cm width or girth and apply two coats of synthetic enamel paint complete as specified & directed.
51Dismantling wrought iron mild steel work of any description etc .complete all as specified and directed.
52S&F rolled mild steel framed work as in doors or gates of angle or other section conforming to Fe-410-S (E-250) quality-B with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
53S & F 1.25mm thick MS, plain black sheet in steel gates, covering to door and similar work, cut to size, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints all as required
54Dismantling asbestos cement / GI based (corrugated,semicorrugated, etc.) or any type of sheets in roof coverings including ridges, valley gutter of any type size and shape etc complete as specified & directed by Engineer-in-Charge.Note: No extra amount will paid for opening of overlapped corrugated roof sheets if requered in dismantling of valley sheet,roof coverings etc.
55S&F Pre-painted galvalume aluminium zinc coating GI based corrugated curved steel sheet 0.50 mm thick having minimum tensile strength of 550mpa as in roof covering / cladding to wall, fixed with self-tapping screws. Pitch of corrugation 175mm -190mm centre to centre and minimum crest depth 29mm. Note:-(i) Colour of prepainted sheet will be as approved by AGE(I).
56S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick having minimum tensile strength of 550mpa as in ridge, valley gutter bend to shape for fixing as required, fixed with self-tapping screws. Note:-(i) Colour of prepainted sheet will be as approved by AGE(I). No extra amount will paid for fixing of opened overlaped sheets.
57S & F 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side fixed with coach/self driving screws and washers in roof, wall etc
58S & F 6 to 8mm thick poly carbonate sheet of colour as approved by Engr-in-Charge in roof coverings incl ridges and fixed with necessary J/J hook, fasterners etc complete as specified & directed
59Excavation in trenches not exc 1.5mtr wide and n.exc. 1.50m deep as in foundation of drain n.exc. 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed..
60M&L for PCC1:3:6 type C-2 using 40mm graded stone aggregate,as in surface channels and drains filling & mass concrete etc complete all as specified and directed.
61M&L brick work with sub class 'B' bricks(old size bricks) straight or curved on plan exceeding 6 mtr mean radius built in cement mortar 1 : 4 and external face of brick work pointed flush in the same mortar as the work proceeds, complete as specified and directed.
62M&L PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate as in lintels,cills, steps; seismic and other similar bands, plinth courses, string courses, acing courses, parapets and railings upto 60 cm in height, copings,benching,or kerbs kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating,complete as specified and directed.
63Returning, filling in, including spreading, levelling, watering and well ramming in layers,soil not exc 25 cm.complete as specified and directed.
64Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point .complete as specified and directed.
65M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, ncluding forms, moulds, mi- tred/stopped ends etc.complete all as specified & as directed
66Add or deduct for each 25 mm girth or part thereof over or under 30cm inner girth in cement concrete, using ex- tra cement, ncluding forms, moulds, mi- tred/stopped ends etc.complete all as specified & as directed.
67Demolition of cement conc.,reinforced cement concrete of any description and in any position not otherwise specifically provided for all as specified and directed by Engineer-in-Charge.
68Providing precast cement concrete type B-1 (1:2:4) using 20 mm grade aggregate set in 1:4 cement mortar in but in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces, complete all as specified & as directed.
69M&L 10mm dia and over TMT bar, cut to length, bent to shape required for RCC pre cast cover slab, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified & as directed.
70M&L old size sub class 'B' bricks laid flat in floor, drain bedded,jointed in CM 1:6 and pointed in CM 1:3 including filling of uneven surface with sand, spreading,levelling,and well ramming the surface after dismantling of bricks complete all as specified & as directed.Note: the rates include for embedding bricks in the ground to depths indicated and tamping ground around bricks and also for removing any surplus spoil, etc
71Ditto all as above item no 72 but except bricks complete all as specified and directed by Engineer-in-Charge.
72M&L old size sub class 'B' brick work laid on edging with width equal to the depth of the brick, laid on edge and jointing and pointing in CM 1:4 including filling of uneven surface with sand, spreading,levelling,and well ramming the surface after dismantling of bricks complete all as specified & as directed.Note: the rates include for embedding bricks in the ground to depths indicated and tamping ground around bricks and also for removing any surplus spoil, etc complete all as specified and directed by Engineer-in-Charge.
73Ditto all as above item no 74 but except bricks complete all as specified and directed by Engineer-in-Charge.
74Dismantling of Bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons,drain etc. (each layer) laid , bedded,jointed and pointed in any mortar.complete all as specified & as directed.
75M&L for writing letters or figures (Block, Roman, Italic or Indian) not exceeding 30cm high including one coat of synthetic enamel paint on the plastered surface before writing etc, complete all as specified and directed by Engineer-in-Charge.
76M&L for stops, comma, short lines, dashes. Hyphen, brackets etc complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58539910
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 05-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint/Replacment Of Misc B/R Works, Periodical Services Of Shed At Varoius Technical Shed At 24 Ed Manauri
Basic Detail
Tender No 8000/77/E8
Bidding Type Tender
Location
City Prayagraj
State Uttar Pradesh
Key Dates
Publish Date 14 Nov 2026
Submission Date 05 Dec 2026
Open Date 07 Dec 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
BOQ_896082.xls
c963e3fa-a5b6-4371-8426-aff413e96262.html
listofmakes77.pdf
TENDER77.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Dec 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_896082.xls

html

c963e3fa-a5b6-4371-8426-aff413e96262.html

pdf

listofmakes77.pdf

pdf

TENDER77.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender