Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #58539904

Tender For Extension Of Existing Cuboid Of Cnc Bay In Industrial Facility Of 1 Brd At Afs Chakeri Kanpur

Issued by Statutory Bodies & Commissions/Committees · Kanpur Nagar, Uttar Pradesh
Tender Value
43.67 Lakhs
Estimated cost
Bid Submission
07 Dec 2026
18 days left
EMD
87340
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kanpur Nagar → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Extension Of Existing Cuboid Of Cnc Bay In Industrial Facility Of 1 Brd At Afs Chakeri Kanpur

BOQ

Name of Work:- EXTENSION OF EXISTING CUBOID OF CNC BAY IN INDUSTRIAL FACILITY OF 1 BRD AT AFS CHAKERI KANPUR
Sl. No. Item Description
1Excavating in post holes (or similar holes) each n exc 0.5cu. m, getting out in hard/dense soil, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
2M & L for PCC 1:2:4 Type B1 (using 20mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
3S & F rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe 410 -W (Gde E- 250) quality A complete all as specified and directed.
4S & F rolled mild steel work in tubular trusses ,posts, purlins & rafters including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.11611979 grade St.-240 complete all as specified and directed.
5S & F 12mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed.
6S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensilestrength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed.
7S & F Providing & fixing false ceiling at all heights with fully perforated 12mm thick micro tegular edged or 10 mm hick square edged GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter locking metal T-Grid of hot dipped galvanized iron section of 0.33 mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000 mm,cross-T of size 15x 32mm of length 1200 mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams persqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners , 6mm dia fully threaded hanger rod upto 1 OOOmm length and L shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawings and complete all as specified and directed.
8S & F powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
9S & F powder coated aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. complete all as specified and directed.
10S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gaske etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, complete all as specified and drawing.
11S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions.
12S & F anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design /pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and directed.
13S & F 5.5mm thick sheet glass,ordinary quality and glazing with oil putty in square exc 0.5sq. m in each pane complete all as specified and directed.
14S & F 4mm thick powder coated aluminium composite panel for aluminium partition wall complete all as specified and directed.
15M & L double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
16M& L for preparation of new or previously untreated steel iron surfaces of any description, over 10cm in width or girth,not otherwise describe and applying two coat of synthetic enamel paint over a coat of primer complete all as specified and directed.
17Excavating in trenches, n exc1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc1.5 m in depth and getting out soft/loose soil complete all as specified and directed.
18M & L for PCC 1:3:6 Type C2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
19M & L for brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4
20M & L for 15mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces finished even smooth without using extra cement complete all as specified and directed.
21M & L for 15mm thick rendering in CM 1:4on fair faces of brick work or concrete surfaces finished even smooth with neeru finish to plastering complete all as specified and directed.
22M& L 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and 15mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to matchwith shade of granite complete all as specified and directed.
23M & L 20mm thick granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
24M & L for providing edge moulding to 18-20 mm thick granite of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete complete all as specified and directed.
25S & Factory made single extruded WPC (Wood Polymer Composite) solid plain flush type as in shelves of 18mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder /rice husk / wheat husk) and nontoxic additives (maximum toxicity index of 12 for 100gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge),minimum compressive strength 50 N/mm2, modulus ofelasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water /moisture proof and fire retardant and fixed with stainless steel L shaped brackets which should withhold as average weight of 20-30 Kg and fixed with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed.
26S&F sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe,overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
27S & F 15mm dia GI pipe, 'medium grade' with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
28Cutting existing steel tubing 20mm bore for alterations or additions (Each cut measured) complete all as specified and directed.
29S & F 15mm bore stop valves, fancy type, chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
30S & F 15mm dia bib taps, fancy type chromium plated screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
31M & L 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
32S & F 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
33M & L for preparing new plastered surfaces of wall and applying three coat of white wash complete all as specified and directed.
34M & L for RCC 1:2:4 Type B1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
35M & L for providing & setting precast cement concrete Type B1, 1:2:4 (using 20mm graded stone aggregate) in CM 1:4 as in slabs (for man holesetc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces fair faces, including chamfers, weatherings,throat- ing etc. complete with joints to match complete all as specified and directed.
36M & L formwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
37TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
38Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
39Removing excavated material exc. 250 m but n exc. 500 m and depositing where complete all as specified and directed.
40Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required 75mm dia pipe complete all as specified and directed.
41M&L Preparation of new steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint over a coat of red oxide primer complete all as specified & as directed.
42M & L for machine cut kota stone slab flooring 18-20mm thick over 15mm thick cement screed base in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
43Dismantling stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar as in floors, aprons etc complete all as specified and directed..
44M & L for PCC 1:2:4 Type B1 (using 20mm graded stone aggregate)as in string course, lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones, bed plates, kerbs etc complete all as specified and directed.
45Supplying Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners (2.0 TR) complete with Indoor unit(IDU) Out door unit (ODU), surface/concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrite rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mir (IDU to ODU) ic drain pipe R-32/R-410/R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz 1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll/rotary compressor The system shall be able to deliver 100% of the rated capacity uple 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply Electrical cable IS 694 or IS 9965 temperature sensing control IS International Electrotechnical Commission (IEC) 60730, hermetic compressor t5 10617, heat exchanger IS 11329 capacitor IS 2993 and motor IS 12615. Complete as per specification and IS 1301 Part II 2023. The system shall be able to operate up to 500C (out door ambient temperature) complete all as specified and directed.
46Supply and fixing of automatic voltage stabilizer for automatic operation single phase, naturally air cooled, indoor type and designed for input variation between 150 V to 285 V with out put voltage at 230 V wih accurac of ±2.5% and of capacity 5 KVA complete all as specified and directed.
47Supplying and fixing 20 A 240 V SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 AC curve, SP MCB in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. complete all as specified and directed.
48Supply and fix copper pipe 1/2\\" outer dia with insulation of suitable size for installation of Split Type AC complete all as specified and directed.. Note -Measurement of copper pipe shall be excusive of copper pipe with insulation as provided with New Split AC (appx 3.0 Rm) complete all as specified and directed.
49Supply and fix copper pipe 1/4\\" outer dia with insulation of suitable size for installation of Split ype ACcomplete all as specified and directed. Note: Measurement of copper pipe shall be excusive of copper pipe with insulation as provided with New Split AC (appx 3.0 Rm) complete all as specified and directed.
50M & L of 4 x 4 sq mm with two continous earth wire of size 4.0 sq mm. ISI marked complete all as specified and directed.Note 4 runs of 4 sq mm cable and two runs of 4.0 sq mm earth wire and PVC conduit will be measured as one ane meter complete all as specified and directed.
51M&L Wiring for circuit/ submain wiring 2 X 4 sq mm + 1 X 4 sq mm alongwith earth wire of FRLS PVC insulated copper conductor singie core cable in surface/ recessed medium class PVC conduit as required ISI marked complete all as specified and directed.
52Supply install, commissioning and testing of commercial Aircurtain unit for prevention of dust and conditioned air losses, single phase 220 V, 50 HZ (Size 4 Feet) made out of MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint (oven baked) with MS-CRC 18 gauge square square perforated suction grills Aluminium alloy fans and single phase electric motor nozzles etc, complete with fittings and accessories so as to produce 1 1.5 m/sec air velocity at floor level for door opening as specified and complete all as specified and directed.
53M & L for surface point wiring on wall and surface on ceiling / roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid stove enamelled steel conduit ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and modular white cover plate with frame for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed for one light point controlled by one switch complete all as specified and directed.
54All as per item No. 53 above but One ceiling fan/exhaust fan control by one switch complete all as specified and directed.
55All as per item No. 53 above but One 3 pin socket outlet, 5 Amps independent complete all as specified and directed.
56All as per item No. 53 above but One 3 pin 5 amps socket outlet on the same board with other switches complete all as specified and directed.
57All as per item No 53 here in before but for one socket out let 2in1 5 and 15 Amps with 2.5 Sqmm PVC insulated copper conductor and provn of 2.5 sqmm PVC insulated single core copper cable green in colour as earth continuity conductor complete all as specified and directed.
58S&F switch flush type single pole one way 5 Amps, 240 volts, white finish ISI Marked complete all as specified and directed.
59S&F switch flush type 15 Amps, 240 Volts single pole white finish complete ISI Marked complete all as specified and directed.
60S&F socket outlet 5 pin, 5 Amps flush type white finish complete conforming/ ISI Marked complete all as specified and directed.
61S&F socket outlet 2 in 1, 3 pin, 5/15 A, flush type universal, 240 V white finish complete conforming/ ISI Marked complete all as specified and directed.
62S&F ceiling rose surface bakelite 65 x 20 mm three terminal conforming ISI marked complete all as specified and directed.
63S&F, S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd.complete all as specified and directed.
64S&F double door metallic sheet metal enclosure for DB when MCBs to be used TPNL, 4 ways, 415Volts (horizontal type) with 200 Amps rated bus bar suitable for TPN MCB/ 4 pole Isolator fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires complete all as specified and directed.
65Supplying and fixing of 8 way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required complete all as specified and directed.
66S&F, testing and commissioning of MCB SP 240 volt 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed.
67Al as per item No 66 above but MCB SPN 40 Amp complete all as specified and directed.
68All as per item No. 66 above, but TPN 63 A 415V complete all as specified and directed.
69M&L for XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade 50 sqmm 3.5 core laid in trenches/panel or passing through pipe including connecting with suitable lugs, nuts and bolts and testing complete all as specified and directed.
70M&L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor wire of size 2.5 sqmm drawn in Steel Conduit with single core 2.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete all fixing accessories such as coupler lock, nuts, pipe hooks etc fixed properly complete all as specified and directed.Note : Two single core cable and one single core of earth copper conductor will be measured and paid as one unit length(ii) Rate quoted are inclusive of steel conduit of 25 mm dia
71S & F sub main wiring for circuit of size 6 sq mm 2 runs (FRLSH) alongwith earth wire of 6 sq mm single runs of FRLSH PVC insulated unsheathed cable, 1100 volts grade with multistranded copper conductor including steel conduit of suitable size, complete in concealed position complete all as specified and directed.
72M & L complete for recess mounting LED Panel 600x600 mm fittings made of CRCA powder coated finish LED used shall be SMD type and fixture should have minimum efficiency at system level (Not chip level) 100lm/watt, life of fixture 50000 burning hours @ L70% Lumen maintenance CCT UP TO 6500,CRI MORE THEN 80,pf 0.95 and an operating voltage 140 Volt to 270 volt complete all as specified and directed.
73M&L for earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, earth plate souroundally filled charcoal and common salt in alternate layer (min 10 Kg charcoal & 10 Kg salt), connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel with and including excavation, PCC (1:3:6) type C-1 (using 20mm graded stone agg) as in chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 8 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia mediam grade, lugs etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 complete all as specified and directed. all as specified and directed. Note :- Main earth lead upto 7.5 mtr shall be deemed to be included in unit rate. Beyong above earth lead shall be measured and paid seperetley.
74M&L for earth continuity conductor or main earthing lead 4 mm dia GI or steel wire fixed to wall on batten or recessed or buried in ground or drawn in conduit/pipe complete all as specified and directed.
75Supply and fixing of ceiling fan, complete with down rod & accessories 230 V, with connection of 1200 mm sweep BEE 5 Star rated complete all as specified and directed.
76Supply and fixing of Exhaust fan 300mm sweep, copper winded , 1400 RPM complee with brackets frme and blades, metallic body heavy duty with lovours suitable size , suitable for 240 Vol, 50 Hz supply complete all as specified and directed.
77Supply, installation, testing and commissioning of CPRI approved indoor type LT panel board suitable for 440 Volt, 3 phase & Neutral , 50Hz supply , weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame,with 2 mm thick CRCA sheet. ( load bearing members 2 mm thick and non load bearing members such as doors partitions etc of thick ness 1.6 mm thick ), with gland plates at bottom with suitable Brass chromium plated glands, with cadmium plated high tensile nut and bolts washers, suitable barrel copper lugs for cable terminations complete, with locking arrangements complete ,sheets bend, folded, cut with CNC machine for the accuracy of diamensions +/-0.5%, duly powder coated with siemens grey colour after chemical trteatment, with suitable ventilation fan at the top ,including LED RYB indicators -03 nos on incoming side & 03 No on outgoing side of breaker and ON/OFF/TRIP indications on outgoing side of breaker, interconnections from bus bars MCCB's with suitable size AL bus bars, all internal ckt / protection wiring with FRLSH 1100 V grade wiring with MCB protection,including terminal adapters, spreader links on incoming and out going sides of MCCB's complete all as specified and directed and comprising of the following :-(a) Bus bar Aluminum - 200 A capacity- 04 Nos high conductivity, suitable for 415 V, 50 Hz supply including interconnection from incoming, and out going feeders with suitable mounting insulators, heat shrinkable colour sleeves. (b) MCCB four pole 440 V, 125-160 Amp,36 KA adjustable thermal and magnetic setting -01 No ( As Incomer) (c) MCCB four pole 440 V, 63-100 Amp,36 KA , adjustable thermal and magnetic setting - 3 Nos (For 3 Nos CNC M/C ) (d) MCCB four pole 440 V, 40-100 Amp,36 KA , with thermal and magnetic settings - 01 Nos (For TPN DB(e) Digital Ammeter including CTs and selector switch -01 No(f) Digital Voltmeter(0-500V) with selector switch -01 No(g) Three Nos indication lamp (R,Y,B) - 1Set of three - 05 No(h) LED Multifunction meter accuracy class 1.0,input voltage 17 to 520V Ac, flush typ, 96x96 mm size, Model Vega of L&T / equivalent make of ABB/ siemens, suitable to measure parameters such as A,V,F,KW,KVA,KVAr,KVARh,Phase angle ,THD etc-01 Nos,(j) Phase sequencer suitable for load upto 200 Amp - 1 Nos Supply and fixing of Exhaust fan 300mm sweep, copper winded , 1400 RPM complee with brackets frme and blades, metallic body heavy duty with lovours suitable size , suitable for 240 Vol, 50 Hz supply complete all as specified and directed by Engineer in Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58539904
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 43.67 Lakhs
LAST DATE 07-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Extension Of Existing Cuboid Of Cnc Bay In Industrial Facility Of 1 Brd At Afs Chakeri Kanpur
Basic Detail
Tender No GE (AF) BR/CHK/T-41 OF 2026-27 8624/A/E8
Bidding Type Tender
Location
City Kanpur Nagar
State Uttar Pradesh
Key Dates
Publish Date 14 Nov 2026
Submission Date 07 Dec 2026
Open Date 14 Dec 2026
Finance
Tender Value 43.67 Lakhs
Tender Fee 500
EMD 87340
Exemption Available
Document List
3d40ef78-49f7-499a-8db3-eb7e01db75cb.html
BOQ_895896.xls
tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Dec 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
html

3d40ef78-49f7-499a-8db3-eb7e01db75cb.html

xls

BOQ_895896.xls

pdf

tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender