Tender For Repair/ Replacement Of Led Fittings Including Internal Wiring/ Distribution Boxes, Repair To Cooling Appliances Repair/ Replacemkent Of Old Unsv Ug Cables, Street Light Poles/ Fittings Including Maintenance Of Transformers Standby Dg Sets
Tender Overview
Project Description
Tender for Repair/ Replacement Of Led Fittings Including Internal Wiring/ Distribution Boxes, Repair To Cooling Appliances Repair/ Replacemkent Of Old Unsv Ug Cables, Street Light Poles/ Fittings Including Maintenance Of Transformers Standby Dg Sets And Other Connected Accessories At installation Kardip & At Icgs Kamorta. 8873/E8
BOQ
| Sl. No. | Item Description |
| 1 | Carrying out quarterly comprehensive and preventive maintenance of under mentioned existing 03 No of diesel generator set of capacity 160 kVA to 250 kVA of any make, including thorough inspection, cleaning, checking, servicing and necessary adjustments of diesel engine, alternator, radiator, cooling system, fuel injection system, lubrication system, air intake and exhaust system, starting system, battery and battery charging system, control panel, AMF panel and associated electrical and mechanical components; checking and tightening of all electrical terminals and connections; checking engine oil level, coolant level, fuel lines, fuel filters, air filters, lubricating oil filters, fan belts, hoses, pipe connections, mountings and vibration isolators; cleaning of radiator fins, air filter housing and engine exterior; checking battery terminals, electrolyte level, specific gravity and charging voltage; checking for oil, fuel and coolant leakage; checking alternator insulation resistance, output voltage, frequency, phase balance, earthing connections, protective devices, safety interlocks and automatic/manual starting arrangements; carrying out necessary lubrication, minor adjustments, tightening and rectification of minor defects, including trial running of DG set on no-load and available load conditions, recording operating parameters and ensuring satisfactory and efficient operation of the complete DG set, including all necessary labour, tools, testing instruments, cleaning materials and incidental operations, complete all as specified, in accordance with manufacturer's recommendations and as directed by the Engineer-in-Charge:- (1) 250KVA DG Set - 01 Nos(2) 160KVA DG Set - 02 Nos Note :-(i) The complete Quarterly servicing, maintenance of captive DG set to be carried out during the contract period with minimum 1 Kirloskar Senior Engineer (OEM) having minimum 5 year experience in maintenance of DG set. Please Enable Macros to View BoQ information |
| 2 | Carrying out quarterly comprehensive and preventive maintenance of under mentioned existing 03 No of diesel generator set of capacity 160 kVA to 250 kVA of any make, including thorough inspection, cleaning, checking, servicing and necessary adjustments of diesel engine, alternator, radiator, cooling system, fuel injection system, lubrication system, air intake and exhaust system, starting system, battery and battery charging system, control panel, AMF panel and associated electrical and mechanical components; checking and tightening of all electrical terminals and connections; checking engine oil level, coolant level, fuel lines, fuel filters, air filters, lubricating oil filters, fan belts, hoses, pipe connections, mountings and vibration isolators; cleaning of radiator fins, air filter housing and engine exterior; checking battery terminals, electrolyte level, specific gravity and charging voltage; checking for oil, fuel and coolant leakage; checking alternator insulation resistance, output voltage, frequency, phase balance, earthing connections, protective devices, safety interlocks and automatic/manual starting arrangements; carrying out necessary lubrication, minor adjustments, tightening and rectification of minor defects, including trial running of DG set on no-load and available load conditions, recording operating parameters and ensuring satisfactory and efficient operation of the complete DG set, including all necessary labour, tools, testing instruments, cleaning materials and incidental operations, complete all as specified, in accordance with manufacturer's recommendations and as directed by the Engineer-in-Charge:- (1) 250KVA DG Set - 01 Nos(2) 160KVA DG Set - 02 Nos Note :-(i) The complete Quarterly servicing, maintenance of captive DG set to be carried out during the contract period with minimum 1 Kirloskar Senior Engineer (OEM) having minimum 5 year experience in maintenance of DG set. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender