| Sl. No. | Item Description |
| 1 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 50 Sqmm 3.5 core as per IS 7092 Pt -I including connecting with suitable size alumunium lugs/thimble and taking out old u/s existing LT cable complete all as specified and directed. Make- Havells /Plaza / Paragon /SCI/KEI/Finolex |
| 2 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 25 Sqmm 4 core as per IS 7092 Pt -I including connecting with suitable size alumunium lugs/thimble and taking out old u/s existing LT cable complete all as specified and directed. Make- Havells/Plaza/Paragon/SCI/KEI/Finolex |
| 3 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 16 Sqmm 4 core as per IS 7092 Pt -I including connecting with suitable size alumunium lugs/thimble and taking out old u/s existing LT cable complete all as specified and directed. Make- Havells/Plaza/Paragon/SCI/KEI/Finolex |
| 4 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 10 Sqmm 4 core as per IS 7092 Pt -I including connecting with suitable size alumunium lugs/thimble and taking out old u/s existing LT cable complete all as specified and directed. Make- Havells/Plaza/Paragon/SCI/KEI/Finolex |
| 5 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 16 Sqmm 2 core as per IS 7092 Pt -I including connecting with suitable size alumunium lugs/thimble and taking out old u/s existing LT cable complete all as specified and directed. Make- Havells/Plaza/Paragon/SCI/KEI/Finolex |
| 6 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 10 Sqmm 2 core as per IS 7092 Pt -I including connecting with suitable size alumunium lugs/thimble and taking out old u/s existing LT cable complete all as specified and directed. Make- Havells/Plaza/Paragon/SCI/KEI/Finolex |
| 7 | M&L for Double wall corrugated (DWC) HDPE pipe , ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls/ pole including all connections, accessories like socket, couplers, bends etc for protection of LT cable XLPE grade 1100 volts including taking down of u/s existing HDPE pipes complete all as specified and directed by Engineer-in-charge. |
| 8 | Excavation in trenches in soft/loose soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out complete all as specified and as directed. |
| 9 | Excavation in trenches in any type of soil not exc 1.5 mtrs wide and exceeding 1.5 mtr but not exc 3 mtr in depth for laying of pipe/ cables/ poles etc and getting out complete all as specified and as directed. |
| 10 | Returning filling in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed. |
| 11 | Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed. |
| 12 | M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in coping of poles etc including form work for poles complete surfce finished even and smooth without using extra cement all as specified and directed by Engr-in-Charge. |
| 13 | M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete for poles (bed concrete) all as specified and directed by Engr-in-Charge. |
| 14 | M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete of poles including form work for poles all as specified and directed by Engr-in-Charge. |
| 15 | S&F of Kiosk box for luminaires ,weather proof made out of PVC FRP housing fire retardant, non fusing, shock & rust proof, single piece moulded and cover with hinged door, pole mounting type comprising of copper connector 4 nos of 16 Amps with 6 Amp MCB single pole , of minimum size 300x200x125mm, IP 66 fixed on pole with MS, clamps 30x5mm with necessary nuts, washer and incl. applying two coats of synthetic enamel paint over a red oxide primer on steel surface/clamps and embossing/painting of Danger sign of size not less than 10cms x 7.5cms with letter and conventional skull and bones in single red color on front face of kiosk box including taking down old u/s existing kiosk box complete all as specified and directed |
| 16 | M & L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt upto 1.5 meter depth all around the earth plate and connected to galvanised earth strip 25x4mm by means of bolts, nuts, check nuts and washers of galvd iron or steel surronded by charcoal of coke and salt and protected by galvanized iron or steel pipe light grade 40 mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 5 of MES schedule Pt I of 2009 and also including making test point for testing of earthing made out of gun metal or phosphorous bronge size 75x75x25 mm complete all as specified and directed by Engineer in Charge |
| 17 | Note : 1. RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover.2. Charcoal dust and common salt upto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate inside earth pit . On testing after completion of earthing if desired earth resistance is not achieved , the earthing will be redone at no extra cost to obtain the desired earth values less than 2 ohms.3. The cost of GI earth lead and GI pipe of 7.50m lenth for protection of GI wire and excavationwork fpr pit shall deemed to be included in this item. |
| 18 | Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP-31) 9.0 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with two coats of aluminium paint over one coat of red oxide primer and incl taking down existing old unserviceable poles & shifting of cross arms ACR conductor , GI wire, insulator, street light brackets etccomplete all as specified and directed. (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed.) Note :- Excavation incl earth work and PCC foundation will be measured and paid separately. |
| 19 | S & F in replacement of GI brackets for fixing LED street light fitting fabricated out of GI tubing 40 mm dia, medium grade, 1.2 mtr long , bend to 120 degree shape by cutting, welding and well finishing including MS clamp of flat iron of size 32 x 4 mm -02 Nos complete for steel poles / PCC pole as per site requirement with nut, bolt & washers for fixing of GI bracket complete all as specified and directed. |
| 20 | S&F in replacement of new generation energy saving and enviromental friendly long life LED security/ street light fitting 45 Watt with pressure die cast housing, toughened glass and secondary lens optics with IP-66 ingress protection, 4 KV in built surge protection, top opening driver cover for easy maintenance, efficacy upto 120 Im/w, white colour, input voltage of 150-240 Volts (Normal rated voltage 240Volts) complete including replacement of twisted 3 core copper cable of size 1.5Sqmm dia for connecting phase, neutral and earth from junction box to LED light through copper connectors complete as specified and as directed. Make:- CG/Wipro/Bajaj/Havells/Phillips .Note:-(i) Warrantty for replacement of each LED light fitting shall not be less than 02 years. |
| 21 | S&F in replacement of new generation energy saving and enviromental friendly long life LED security/ street light fitting 60 Watt with pressure die cast housing, toughened glass and secondary lens optics with IP-66 ingress protection, 4 kv in built surge protection, top opening driver cover for easy maintenance, efficacy upto 120 Im/w, white colour, input voltage of 150-240 Volts (Normal rated voltage 240Volts) complete including replacement of twisted 3 core copper cable of size 1.5Sqmm dia for connecting phase, neutral and earth from junction box to LED light through copper connectors complete as specified and as directed. Make:- CG/Wipro/Bajaj/Havells/Phillips .Note:-(i) Warrantty for replacement of each LED light fitting shall not be less than 02 years. |
| 22 | S&F in replacement of new generation energy saving and enviromental friendly long life LED security/ street light fitting 70 Watt with pressure die cast housing, toughened glass and secondary lens optics with IP-66 ingress protection, 4 KV in built surge protection, top opening driver cover for easy maintenance, efficacy upto 120 Im/w, white colour, input voltage of 150-240 Volts (Normal rated voltage 240Volts) complete including replacement of twisted 3 core copper cable of size 1.5Sqmm dia for connecting phase, neutral and earth from junction box to LED light through copper connectors complete as specified and as directed. Make:- CG/Wipro/Bajaj/Havells/Phillips. Note:-(i) Warrantty for replacement of each LED light fitting shall not be less than 02 years. |
| 23 | S&F in replacement of new generation energy saving and enviromental friendly long life LED security/ street light fitting 90 Watt with pressure die cast housing, toughened glass and secondary lens optics with IP-66 ingress protection, 4 KV in built surge protection, top opening driver cover for easy maintenance, efficacy upto 120 Im/w, white colour, input voltage of 150-240 Volts (Normal rated voltage 240Volts) complete including replacement of twisted 3 core copper cable of size 1.5Sqmm dia for connecting phase, neutral and earth from junction box to LED light through copper connectors complete as specified and as directed. Make:- CG/Wipro/Bajaj/Havells/Phillips .Note:-(i) Warrantty for replacement of each LED light fitting shall not be less than 02 years. |
| 24 | S&F in replacement of new generation energy saving and enviromental friendly long life LED security/ street light fitting 120 Watt with pressure die cast housing, toughened glass and secondary lens optics with IP-66 ingress protection, 4 kv in built surge protection, top opening driver cover for easy maintenance, efficacy upto 120 Im/w, white colour, input voltage of 150-240 Volts (Normal rated voltage 240Volts) complete including replacement of twisted 3 core copper cable of size 1.5Sqmm dia for connecting phase, neutral and earth from junction box to LED light through copper connectors complete as specified and as directed. Make:- CG/Wipro/Bajaj/Havells/Phillips. Note:-(i) Warrantty for replacement of each LED light fitting shall not be less than 02 years. |
| 25 | S&F in replacement of LED flood light 70 watt 230 Volt, AC outdoor type high performance with pressure die cast housing, toughened glass and secondary lens optics with IP-66 ingress protection, efficacy 120 Im/W complete with driver and lamp all as specified and directed. Make:- CG/Wipro/Bajaj/Havells/Phillips. Note:-(i) Warrantty for replacement of each LED light fitting shall not be less than 02 years. |
| 26 | S&F in replacement of LED flood light 100 watt 230 Volt, AC outdoor type high performance with pressure die cast housing, toughened glass and secondary lens optics with IP-66 ingress protection, efficacy 120 Im/W complete with driver and lamp all as specified and directed. Make:- CG/Wipro/Bajaj/Havells/Phillips .Note:-(i) Warrantty for replacement of each LED light fitting shall not be less than 02 years. |
| 27 | S&F in replacement of LED flood light 170 watt 230 Volt, AC outdoor type high performance with pressure die cast housing, toughened glass and secondary lens optics with IP-66 ingress protection, efficacy 120 Im/W complete with driver and lamp all as specified and directed. Make:- CG/Wipro/Bajaj/Havells/Phillips .Note:-(i) Warrantty for replacement of each LED light fitting shall not be less than 02 years. |
| 28 | Supply and fixing Post top lantern LED 20 watt 230 watt volts AC outdoor type made in die cast alumnium bottom housing and spun aluminium top reflector with decorative clear acrylic diffuser and IP-65 protection opal diffuser complete all as specified and directed. Make:- CG/Wipro/Bajaj/Havells/Phillips .Note:-(i) Warrantty for replacement of each LED light fitting shall not be less than 02 years. |
| 29 | S&F in replacement of LED bollard/garden light stailess steel 9 watt weather proof light (warm white) with opal acrylic diffuser, IP-66 protection complete with all accessaries including excavation and grouting with PCC foundation complete all as specified and directed. Make:- CG/Wipro/Bajaj/Havells/PhillipsNote:-(i) Warrantty for replacement of each LED bollard light fitting shall not be less than 02 years from date of pruchse. |
| 30 | M&L for restringing of LT overhead line conductor comprising of any size ACSR conductor after opening from insulators, including restringing same and winding on insulator with proper size of binding wire upto permissible sag complete all as directed by Engineer in Charge. |
| 31 | M&L for Cutting and trimming of tree branches of any girth all around the HT/LTover head lines upto two mtr from all around the over head lines complete and removing the cut branches from site to a distance not exc 50 mtr all as directed. Note:- T&P required for cutting/trimming of tree branches shall be provided by contractor without any extra cost complete all as directed by Engineer in Charge. |
| 32 | S&F MCB 63 Amp TPN 'C' series for street light complete all as specified and directed. Make:-Havells/L&T/ABB/Legrand |
| 33 | S&F MCB 6 - 32 Amp SPN for street light complete all as specified and directed. Make:-Havells/L&T/ABB /Legrand |
| 34 | S&F in replacement of contactor of rating 63 Amps, 230 volts suitable for single phase street light timer complete all as specified and directed |
| 35 | S&F in replacement of relay of rating 63 Amps, 230 volts suitable for single phase street light timer complete all as specified and directed |
| 36 | S&F in replacement of contactor of rating 40 Amps, 230 volts suitable for 3 phase street light timer complete all as specified and directed |
| 37 | S&F in replacement of relay of rating 40 Amps, 230 volts suitable for 3 phase street light timer complete all as specified and directed |
| 38 | S&F in replacement of MCB of rating 63 Amps, 230 volts suitable for single phase street light timer complete all as specified and directed |
| 39 | S&F in replacement of MCB of rating 40 Amps, 230 volts suitable for 3 phase street light timer complete all as specified and directed |
| 40 | Supply only PVC insulation tape (Red, Black, Yellow, Green colour) 15 mtr length suitable for LT XLPE cable complete all as specified and as directed. |
| 41 | Supply only PVC insulated stranded aluminium conductor 1100 Volts grade heavy duty ISI marked two core cable flat or circular of size 6 Sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connections etc complete all as specified and direcetd. |
| 42 | Supply only PVC insulated stranded aluminium conductor 1100 Volts grade heavy duty ISI marked two core cable flat or circular of size 4 sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connections etc complete all as specified and direcetd. |
| 43 | Supply only cable PVC insulated copper conductor 1100 Volts grade heavy duty ISI marked three core cable flat or circular of size 1.5 sqmm for street light connections etc complete all as specified and direcetd. |
| 44 | Supply only aluminium lugs/thimble suitable for LT XLPE cable of size 10 Sqmm complete all as specified and directed |
| 45 | Supply only aluminium lugs/thimble suitable for LT XLPE cable of size 16 Sqmm complete all as specified and directed |
| 46 | Supply only aluminium lugs/thimble suitable for LT XLPE cable of size 25 Sqmm complete all as specified and directed |
| 47 | Supply only aluminium lugs/thimble suitable for LT XLPE cable of size 50 Sqmm complete all as specified and directed |
| 48 | Supply only LED drivers of LED streeet light /flood light/Glow sign board as per existing sample of any make , of capacity 30 watts to 60 watts including replacement of burnt drivers carefully and as directed |
| 49 | Supply only LED drivers of LED streeet light /flood light/Glow sign board as per existing sample of any make , of capacity 70 watts to 90 watts including replacement of burnt drivers carefully and as directed |
| 50 | Supply only LED drivers of LED streeet light /flood light/Glow sign board as per existing sample of any make , of capacity 100 watts to 150 watts including replacement of burnt drivers carefully and as directed |
| 51 | Supply & fixing GI tube 40 mm bore light grade with all fittings for laid in trenches/fixed along with poles/walls & floor of buildings etc under crossing of road for protection of cables including demolition and taking down of the old existing pipe including repair of the floor/wall and matching with the existing surface if required complete as directed by Engineer-in-Charge. |
| 52 | Supply & fixing in repair of three phase 415 V automatic street light timer switch of capacity 12 KW using integrated sensor based NATURE SWITCH for automatic switching of street lights based on LUX level of natural light required illuminance for switching on is ‹ 30 Lux and for switching OFF › 10 Lux level. The sensor (nature switch) along with suitable power contactors input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof , termite proof and FR graded SMC junction box conforming of IP 66 degree of ingress three phase 12 KW lightning load capacity including mounting bracket , cable glands, openable doors with lock complete all as specified and directed. |
| 53 | The contactor MCB and circuit wiring should suitable enough to take load of 12 KW equally distributed over three phase and street light timer should be comprising of following:- (a). Input MCB rating 40 Amps - 03 Nos (b).Contactor rating 40 Amps - 03 Nos (c).Out put MCB rating 40 Amps - 03 Nos (d).Three phase circuit wiring minimum 10 Sqmm multistranded copper wire. (e) Model No :- SWADEEP -02EC 12 KW 3 P- VMS. Make :- Kakatiya Energy Systems Ltd (f). Voltage monitoring - Device (SM500 Make -GIC/L&T)-01 Nos.Note:-(i) 01 year Guarantee + 01 year Warranty on sensor & 01 year warranty on remaining other items from date of purchase. |
| 54 | Supply & fixing in repair of single phase automatic street light timer switch of capacity 8 kw using integrated sensor based NATURE SWITCH for automatic switching of street lights based on LUX level of natural light required illuminance for switching on is ‹ 30 Lux and for switching OFF › 10 Lux level. The sensor (nature switch) along with suitable power contactors input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof , termite proof and FR graded SMC junction box conforming of IP 66 degree of ingress single phase 8KW lightning load capacity including mounting bracket , cable glands, openable doors with lock including taking down of u/s existing timer panel complete all as specified and directed. |
| 55 | The contactor MCB and circuit wiring should suitable enough to take load of 8 KW and street light timer should be comprising of following:- (a). Input MCB rating 63 Amps - 01 Nos (b) .Contactor rating 63 Amps - 01 Nos (c). Out put MCB rating 63 Amps - 01 Nos (d). Single phase circuit wiring minimum 16 Sqmm multistranded copper wire. (e) Model No :- SWADEEP -02EC 8 KW1P- VMS. Make :- Kakatiya Energy Systems Ltd (f). Voltage monitoring - Device (SM500 Make -GIC/L&T)-01 Nos.Note:-(i) 01 year Guarantee + 01 year Warranty on sensor & 01 year warranty on remaining other items from date of pruchse. |
| 56 | M&L for painting of steel tubuler 9 mtr poles any type complete incl flat iron clamps, D clamps, Stay clamps, earth wire clamps, bracing, cross arm with two coat aluminium paint including prepration old painted surface initally & applying one coat of red oxide, applying two coat of aluminum paint over the red oxide, marking with alternate white and red strips 30 cm height 5 Nos strips with two coat of synthetic enamel paint (Ist quality of manufacturer )and also including numbering of poles with white paint are located on different locations complete all as specified and directed . |
| 57 | M & L for cutting of road up to 0.75m deep suitable for laying underground cable/MS tubes of any size/dia including GI pipe of 50mm dia and making good the disturbed area to match with the existing level with cement concrete including removing the surplus soil to a distance upto 50mtrs complete all as specified and directed. |
| 58 | S&F in replacement of Tri Colour LED light strip of 18 mtr (saffron, white and green) around the pole out door grde IP-65 LED strip with uniform illumination complete with clamps, driver, wiring and commissioning all as specified and as directed by Engr-in-Charge. |
| 59 | S&F in replacement of LED driver suitable for glow sign board as per existing sample or user requirement complete all as specified and as directed. |
| 60 | S&F in replacement of plastic LED kerb stones light as per existing sample or user requirement complete all as specified and as directed. |
| 61 | Demolition of existing complete roof treatment of any description i.e APP membrane, brick tiling including cement mortar OR concrete padding and open up top layer of roof mother slab (any type) complete removal of debris from site all as directed by Engineer in Charge.Note :- The work is required to be carried out at roof for single/double storey . The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof for site inspection. The rates quoted shall deemed to be included for these items. |
| 62 | M&L for wire brushing and cleaning top surface of roof slab, flashing and junction of parapet etc including picking, sweeping cleaning and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any other loose material complete all as directed by Engineer in Charge. |
| 63 | M&L for widening the cracks in existing roof or teracing , cleaning out , wetting and grouting with polymer mortar (cement : sand in 1;4) admixed with crack seal as per manufctured direction all as directed by Engineer in Charge |
| 64 | M&L for one coat of Cement slurry admixed with acrylic bonding compound SBR Latex of approved make as to be used for bonding of new concrete/ mortar to old surface.(will be applied and as per direction of manufacturer ) |
| 65 | M&L for 40mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded stone agg) mixed with polymer modified repair mortar (SBR Latex liquid polymer as per manufacturer direction ) and finishing the surface even and smooth using extra cement as in roof padding to receive roof treatment complete all as specified and directed.Note :- (SBR) Latex liquid polymer will be measured and paid seperately.. |
| 66 | Cutting grooves in brick wall 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed. |
| 67 | M&L for Concrete angle-fillets of required radiaus shall be provided at junctions between roofs and vertical faces of walls (parapet, pillar for water tank staging and other walls) around obstacles such as pipes, chimney stacks, etc. and other similar situation to ease up about corners.with cement concrete 1:2:4 (Using 12.5mm stone aggregate) mixed with liquid polymer all as directed by Engineer in Charge. (SBR Latex liquid polymer will be mixed as per manufactur direction and paid separately) |
| 68 | Supply only SBR Latex liquid polymer of approved make. |
| 69 | M&L of water proofing treatment to roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :-(a) Applying evenly a tack coat @ 1.2 kg/Sqm using 85/25 grade of industrial hot blown bitumen on primed surface of roof by applying a priming coat of bituminious primer @ 0.30 Kg /Sqm, till the surface is properly impregnated.(b) Providing APP modified 5 layer polymeric membrane minimum weighing 3.6 Kg /Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer(c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance. |
| 70 | Note : 1. The work of water proofing treatment shall be got executed through manufacturer or authorised applicator of the manufacturer only 2. The work is required to be carried out at roof slab . The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof for site inspection . The rates quoted shall deemed to be included for these items.) |
| 71 | Dismantling roof tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises and complete all as specified and as directed. |
| 72 | M&L for Cool Roof Tiles 9-10mm thick 300 MM X300 MM Size (Make: Orient Bell or Equivalent ceramic tiles white confirming to sun reflective Index (SRI) value minimum of 90; set jointed and pointed in neat with grey cement and no pigment slurry in floors, and cut and polishedand shall be laid over 15 mm thick cement mortar screed in 1:3 and joints between the tiles to be filled with chemical like Tile grout or equilent complete all as specified and directed. |
| 73 | Taking up or down existing 20 mm dia bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed. |
| 74 | Taking up or down existing 25 mm dia bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed. |
| 75 | Supplying and laying of CPVC pipes of outer diameter 20mm of grade SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified |
| 76 | Supplying and laying of CPVC pipes of outer diameter 25mm of grade SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified |
| 77 | Fixing only old steel tubing 20mm and connections obtained from taking down in new or old position fixed to wall, ceiling or laid in floor with new fittings complete all as specified and as directed |
| 78 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting n.exc10 cm girth in brick walls complete all as specified and directed |
| 79 | Dismantling of PVC water tanks & removing to store exc 500 & n exc 1000 litres complete all as directed by Engineer in Charge. |
| 80 | S&F rotational moulded multilayer HDPE water storage tank of 3 Layer white color of 1000 ltrs capacity (Cylindrical vertical with closed top) fixed in position complete all as specified including 02 Nos CPVC tank adapter of size 20 mm dia & 20 mm dia PTMT float valve with epoxy coated Aluminium rod with high density plastic float ball etc, complete all as specified and as directed. |
| 81 | Disconnecting existing water tanks, setting aside (or lowering if required) for repairs, cleaning etc and reconnecting and refixing in position capacity of tank exc 500 and n.exc 1000 ltr. (cleaning, repairing etc measured separately) |
| 82 | Cleaning and removing all scale and dirt etc. from tanks and from mouths of circulating pipes etc capacity of tank exc 500 ltrs but n.exc 1000 Ltrs complete all as specified and as directed. |
| 83 | S & F in repair 20mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed. |
| 84 | Taking down cement plaster of any description and in any position of brick or stone wall/concrete surfaces on walls ,ceiling etc including raking out joints ,hacking for key scrubbing down with water etc & prepared to receive new plaster complete all as specified and directed |
| 85 | M&L for 15mm thick rendering on fair faces of brick/concrete surfaces in CM 1:4 finished even and smooth without using extra cement omplete all as specified and as directed. |
| 86 | M&L for preparation of new plastered surface of external wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over a coat of plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even & smooth complete all as specified and directed. complete all as specified and directed. |
| 87 | M&L for complete removal of existing treatment from surface of wall all as specified and as directed by the Engineer-in-Charge |
| 88 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over a coat of plaster of paris putty of 1 mm thickness over old external plastered surface to prepare the surface even & smooth complete all as specified and directed. |
| 89 | Preparation of old painted surface of wood and wood based material any description and in any position over 10 cm width or girth and M&L for applying one coat of synthetic enamel paint complete all as specified and directed. by Engr-in-Charge. |
| 90 | Demolition and breaking up drain pipes (Salt glazed ware, AC/PVC/CI or Reinforced concrete) set in cement mortar in floors or wall in 110/75mm dia meter complete all as specified and directed |
| 91 | S&F 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with clamp out of 25x3mm flate Iron including bolts and nuts 110mm bore complete all as specified and directed |
| 92 | S&F PVC (SWR) bends any radius 110mm bore complete all as specified and directed |
| 93 | S&F PVC (SWR) junction single, (single T) equal or unequal 110mm bore with access door complete all as specified and directed. |
| 94 | S&F PVC (SWR) vent cowl 110mm bore complete all as specified and directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender