Tender For Special Repair To Bldg No P-151 (Pump House) Gomat At Pokaran Mil Stn
Tender Value
9.69 Lakhs
Estimated cost
Bid Submission
30 Nov 2026
8 days left
EMD
19500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jaisalmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Bldg No P-151 (Pump House) Gomat At Pokaran Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises |
| 2 | M&F glazed ceramic coloured tiles (300mmx 450mmx7 mm) in vertical surfaces jointed in neat cement slurry and pointed in white cement. Incl cutting the tiles to the required size whereven required incl mitring the corners etc over 10 mm thick backing coats of cement plaster in CM (1:4) complete all as specified and directed. |
| 3 | Taking down chowkhat or frame existing doors/windows/ventilators (without taking off shutters and guard bars) of n exe 1.5 sqm complete all as specified and as directed incl stacking the materials properly. |
| 4 | Providing and fixing powder coated 50 microns extruded aluminium in 3 Tier Track Sliding Windows/glazing, with frame of section 100x44-45x1.30mm, track of size 100x38.10x1.30 & shutters made of size 32x18x1.3mm, with and including 4mm thick tinted sheet glass selected quality fixed in 2 shutters and stainless steel wire gauage 0.36mm nominal dia of wire and average width of aperture 1.40mm in one shutter and including EPDM gasket to render the glazing, air and water tight etc. & aluminium beeds 20mm size and also including powder coated 150mm handle with built in locking system for each leaf complete all as specified.Make (Aluminium Sections) : Jindal/Valco/Galco/Hindalco or equivalent as approved by Engr-In-Charge |
| 5 | S&F Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe Fe 290 Gde E-165 |
| 6 | M&L preparation of new steel surface and applying two coats of synthetic enamel paint ovre a coat of red oxide primer. |
| 7 | Dismantling of Stone slabs and tiles of any description or thickness in floors, walss, aprons etc., removing serviceable tiles to store and rubbish off the premises. |
| 8 | M & L for Machine cut kota stone slab flooring 20-25mm thick for window cill, jambs and sofits over and including cement screed base 15 mm thk in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including dismantling of stone slab |
| 9 | Complete removal of existing water proofing treatment incl bedding if any n exc. 50mm thick etc. on any type of roof, cleaning with wire brushers etc. and removal of debris out side MD land complete all as specified and directed. |
| 10 | Demolition of concrete of any description and in any position (PCC Padding over roof) complete all as specified and as directed by the Engineer-in-Charge. |
| 11 | M&L for PCC 1:2:4 type BO using 12.5 mm graded stone aggregate for levelling course for consolidated thickness shall be varied from 50 mm as per the requirements all as directed by Engr-in-Charge. |
| 12 | M&L for 10mm thick screed plaster on roof for laying in CM 1:4 waterproofing treatment, with using WPC (WPC will be measured and paid separately as supply only) |
| 13 | Supply only integral Waterproofing compound. |
| 14 | M&L for APP based polymeric membrane minimum weighing 3 Kg/Sqm and minimum 3mm thick reinforced with polyester non wove fabric (wt not less than 150 gms/sqm) laid over primed surface including bituminous primer conforming to IS-3384 applied @ 0.3 Ltr/Sqm by forced all as specified and as directed |
| 15 | M & L for 50mm thick plain cement concrete type C-2 (1:3:6) with 20mm garded stone aggregate in plinth protection complete all as specified and directed. |
| 16 | Dismantling of RCC/steel posts/struts any section , including taking out embedded in concrete, brick work or stone masonry including taking out embedded portion etc and making to disturbed ground complete all as specified and directed. |
| 17 | Dismantling of fencing wire mesh any type |
| 18 | M&L for PCC in foundation filling ;and mass concrete (1:3:6) type C-2 using 40 mm graded stone aggregate all as specified. |
| 19 | S&F Posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0 |
| 20 | S&F 11 to 15mm dia Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n.exc 10cm long |
| 21 | Supply only Chain link MS galvanised fencing, any size or type |
| 22 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire |
| 23 | Supply only MS 10mm dia round bars as line wire for chain link fencing complete all as specified and directed |
| 24 | Supply and fixing in repairs galvanized 2 strand, steel barbed wire 2.24 mm dia, barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of stranded rails, straining bolts, including securing or tying at crossing with and provisions of galvanized MS wire, staples or steel pins, etc as directed (Each line wire to b e measured). |
| 25 | Dismantling mild steel work of any description not otherwise as specified and directed. |
| 26 | S &F framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering. Door etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and decorative cast iron artical etc. |
| 27 | Demolition of stone masonry built in cement or cement lime mortar all as specified and directed. |
| 28 | M&L for squared rubble walling, Jodhpur type brought up to courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) all as specified & directed. but except stone |
| 29 | Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exceeding 20mm & dressing face beds and joints as specified to squared rubble walling Jodhpur type brought up to courses all as specified & directed by Engineer-in-Charge. |
| 30 | Taking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and directed. |
| 31 | M & L for rendering 5 mm thick ready mix self curing plaster on ceilling by adding potable water by weight of material as mentioned by manufacture ready mix plaster shall comply with IS- 1661-1972, IS-2402-1963, IS-2250-1981 and shall confirm 28 compressive days cstrength 10-15 MPA bulk dencity 1600-1800 kg/cum and pull out bond strength-> 0.5 MPA omplete all as specified and directed. |
| 32 | M & L for rendering 10mm thick ready mix plaster on internal wall by adding potable water by weight of material as mentioned by manufacture ready mix plaster shall comply with IS- 1661-1972, IS-2402-1963, IS-2250-1981 and shall confirm 28 compressive days cstrength 10-15 MPA bulk dencity 1600-1800 kg/cum and pull out bond strength-> 0.5 MPA omplete all as specified and directed. |
| 33 | M & L for Cement plastering 15mm( thick in two layers -first layer 10mm thick with ready mix plaster and outer layer 5mm thick ready mix water proof plaster) on outer walls by adding potable water by weight of material as mentioned by manufacture ready mix plaster shall comply with IS- 1661-1972, IS-2402-1963, IS- 2250-1981 and shall confirm 28 days compressive strength 10-15 MPA, bulk density 1600-1800 kg/cum and pull out bond strength->0.5 MPA complete all as specified and directed |
| 34 | M&L preparation of new wall surface and applying three coat of white wash on surfaces of ceiling complete all as specified & directed by Engineer-in-charge. |
| 35 | M & L for Applying 3mm thick wall care putty on wall for desired smoothness and levelling of surfaces in two or more layers) for receiving painting complete all as specified and directed.Make of wall Putty : JK wall Putty / Birla Wall care Putty / Bison Wall Putty or equivalent as approved by Engr-In-Charge .Notes : (i) The prepared surface after wall putty, the contractor will inform to the AGE as well as to the Engineer-in-Charge for site inspection before applying further external finishes. Please note that the further external finishes work will start only after approval of the prepared surface from the AGE as well as to the Engineer-in-Charge through site order. |
| 36 | M&L for preparation of new plastered surface of wall and applying Two coat of oil bound distemper over the alkali resistance priming paint primer over 1.5 to 2mm thick wall care putty complete all as specified and as directed. |
| 37 | M & L for Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)Make of Exterior Wall Primer : Asian / BerAGEr / Nerolac [Best Quality].Make of Exterior Emulsion : Asian (APEX) / BerAGEr (WEATHER COAT ANTI DUST) / Nerolac (EXCEL TOTAL) . |
| 38 | Demolition of RCC of any description and in any position not otherwise specifically provided rainforced (rainforcement of cut as required to facilasite demolition etc) and removal of rubbish/ demolished materials out of MD land complete all as specified and directed. |
| 39 | Providing and placing in position microconcrete which shall be cement based prepacked single component, chloride free, non-shrink, free flow, self compacting, ready to use after mixing water in specified proportion obtained from approved manufacturer of thermoex chemical as per speciification and direcation of engineer-in-charge (payment under this item shall be made only after wet curing bas been done and surface has been satisfactory evaluated by sounding/tapping with blunt metal instrument). |
| 40 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter |
| 41 | M&L for form work to side and soffits of floor or roof beam,beam haunchings,girders,bressummers,lintels,cantilevers,shelves including sup-ports,overhangs,etc also splays between floors and beam,etc |
| 42 | S & F mild steel TMT bars 10 mm dia over, cut to length, bent to shape required including crancking bending spirally for hooping for columns hooking ends and binding with and including mile steel wire not less than 0.9 mm dia securing with clips in quality complete all as specifed and directed. |
| 43 | -ditto- all as per item No 42 here in before but 6mm to 44mm dia quality confirming complete all as specified and directed. |
| 44 | Taking down carefully aluminium point wiring any type ,surface/concealed/ PVC capping or tubing ( including light,fan,s/socket, or power)complet fittings such as switches,ceiling rose,pendents,regulators,sockets etc complet |
| 45 | Taking down and refixing ceiling fan/cabin fan/ air circulating fan with cleaning & painting of ceiling fan complete with two coat of synthetic enamel paint of white colour by spraying including filling cavities with filler complete all as directed by E- in- charge after minor repairs |
| 46 | Taking down and refixing exhaust fan with cleaning & painting of exhaust fan complete with synthetic two coat of enamel paint of black colour by spraying including filling cavities with filler complete all as directed by E- in- charge after minor repairs |
| 47 | M & L for point wiring with two single core 1.5 Sqmm cabel (nominal area) stranded copper conductor, PVC insulated unsheathed FRLSH cable, 1100 V grade, conforming IS:694 & colour code in conduit system of wiring, drawn in and including concealed rigid PVC Conduit not less than 20 mm dia with galvanised modular metal flush box, thickness as per OEM suitable of suitabe size and modular white cover plate with frame of suitale module and wiring to be terminated in pressed steel sunken boxes including all accessories fixed with chromium plated screws and washers and using single core 1.5 Sqmm (nominal area) stranded copper conductor, PVC insulated unheated FRLSH cable as in earth wire (green colour) connecteedd to common earth only complete all as specified and directed for following:- (a) One light, C/Fan, E/Fan, bell point controlled by one switch. |
| 48 | (b) All as per item no. 4 above here in before but with copper conductor cable of size 1.5 Sqmm for one 3 pin socket outlet, 5 amp on same board. |
| 49 | (c) All as per item no. 4 above here in before but with copper conductor cabe of size 2.5 Sqmm for one 3 pin socket outlet, 5 amp on independent board. |
| 50 | All as per item no. 4 above here in before but with copper conductor cabe of size 4 Sqmm for one 3 pin socket outlet, 16 amp on independent board. |
| 51 | S & F for Modular switch, flush button, 1 way, 6A, 1 module, complete as specified and directed by Engineer- in- charge. |
| 52 | M & L For modular socket outlet 2/3pin, 2 module, 6Amps, 230 Volts AC, complete all as specified and directed by Engineer-in-charge. |
| 53 | M & L For modular socket outlet 2 in 1, 6 pin, 2 module, 6/16Amps, 230 Volts AC, complete all as specified and directed by Engineer-in-charge. |
| 54 | S & F for Modular switch, flush button, 1 way, 16A, 1 module, complete as specified and directed by Engineer- in- charge. |
| 55 | S & F ceiling rose surface backlite 65x50mm 3 terminals complete. |
| 56 | S & F Modular Fan step regulator, 120 W-1 module complete all as specified and directed. |
| 57 | M&L Modular white cover plate with frame ( both inner & outer plate cover) 1 module |
| 58 | M&L Modular white cover plate with frame ( both inner & outer plate cover) 3 module |
| 59 | M&L Modular white cover plate with frame ( both inner & outer plate cover) 8 module |
| 60 | M&L Modular white cover plate with frame ( both inner & outer plate cover) 6 module |
| 61 | Supply and fix in repair LED tube light fitting capacity 20 watt fixed on wall/surface / ceiling with all accessories tube,driver,with surge protector completerewired with multistranded copper cable & connecting to ceiling rose with 3 core ,multistranded flexible copper cable. |
| 62 | M&L in repair lamp holder insulated body with back plate suitable for battern fittings |
| 63 | supply and fix in repair LED Lamp Retro fit type 9 watts 230 V and all as specified by Engr-in-charge |
| 64 | Supply, fix,in reapir connecting and testing factory made, MCB distribution board (MCB DB), IP 38, SPN, 8 way, 415 Volts, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatised, duly powder coated and conforming to IS 13032 with 200 Amps rated bus bar, neutral link, earth bar and din rail etc. complete fixed in switch board/ wall complete all as specified and directed. Note: MCBs shall be measured and paid separately. |
| 65 | S&F connecting and testing MCB Single pole (MCB SP) 6-32 Amps , 240 Volts of rupturing capacity 10 KA, C Curve type complete all as specified and directed. |
| 66 | S&F MCB SPN 40 A rating 240 V, 10KA, C series fixing in DB's including connecting with bottle type copper thimble complete all as specified and directed by Engr-in-Charge |
| 67 | S & F in repair 15 Watt LED Bldg security light with a nominal system . The luminaire housing should be made of pressure die cast aluminimum. The total power consumption should not exceed 15W (including driver) pre wired fitted on and including two Nos PVC block of suitable l size and connection up to tube light fitting with connecting up with copper 3 core flexible cord of minimum size 0.5 Sqmm size and testing complete including LED lamp, including taking down old unserviceable fitting any type complete all as specified and as directed. |
| 68 | Earthing with galvanised iron earth plate electrode 600 x 600 mm & 6 mm thick burried directly in ground (earth pit not less than 2.25 metre deep below normal GL) with top of earth plate not less than 1.5 metre below GL connected to GI earth lead wire 4 mm dia connected to earth plate electrode by means of GI nuts, bolts & washers earth wire protected with & including 15 mm dia medium grade ISI marked GI pipe not less than 7.5 metre long all as shown in electrical plate No. 3 MES Schedule Part 1, with & including ; PCC 1:3:6 B1 reinforced with welded steel wire fabric not less than 4 Kg per Sq M, watering arrangements with 20 mm GI medium grade pipe ISI marked , GI funnel with GI mesh, filling with mixture of common salt & charcoal, necessary excavation and earth works in any type of soil, including test point, testing & commissioning, complete. (Note :- GI earth wire with GI pipe protection beyond 7.5 metre measured & paid separatelyand it includes taking down old existing earthing.) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysDec 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer