Tender For Annual Rate Contract For Providing Way Finding Signages And Associated Electrical Works Including Providing Decorative Lighting For Terminal Building & Carpark Area Of T1, T2 & T4 In View Of Festival / Occasions And Supply Of Electrical Sp
Tender Overview
Project Description
Tender for Annual Rate Contract For Providing Way Finding Signages And Associated Electrical Works Including Providing Decorative Lighting For Terminal Building & Carpark Area Of T1, T2 & T4 In View Of Festival / Occasions And Supply Of Electrical Spares And Other Miscellaneous Works At Chennai International Airport.
BOQ
| Sl. No. | Item Description |
| 1 | SH-I: Decorative Lighting Common for all Festivals / Occasions. |
| 2 | Hiring charges for providing illumination with standard coloured serial LED lamps 15,000 sets per day (containing minimum 40 Nos. of lamps per set) on the city side of terminal buildings T1, T2 & T4 including Admin Building, fly over, carpark area, Lawn & Trees for the following Occasions as required and as per the direction of Engineer-in-Charge.1. Independence day - 3 days2. Diwali - 2 days3. Christmas - 2 days4. New Year - 2 days5. Pongal - 3 days6. Republic Day - 3 days7. Other occasions - 4 Days |
| 3 | Hiring charges for providing illumination with multicolour LED colour wash flood lights 500 nos per day with required cables & all accessories to illuminate the facia of terminals T1, T2, T4 & Admin Building to create bright & colourful ambience for the following Occasions as required and as per the direction of Engineer-in-Charge.1. Independence day - 3 days2. Diwali - 2 days3. Christmas - 2 days4. New Year - 2 days5. Pongal - 3 days6. Republic Day - 3 days7. Other occasions - 4 Days |
| 4 | Hiring charges for providing illumination with RGB pixel digital serial lighting LED lamps 2,000 sets per day (containing minimum 40 Nos. of lamps per set) on the city side of terminal building T1, T2 & T4, including Admin Building, fly over, carpark area, Lawn, admin building, V&Y type columns of buildings etc. for the following Occasions as required and as per the direction of Engineer-in-Charge.1. Independence day - 3 days2. Diwali - 2 days3. Christmas - 2 days4. New Year - 2 days5. Pongal - 3 days6. Republic Day - 3 days7. Other occasions - 4 Days |
| 5 | Hiring charges for providing illumination with LED strip Lights 1500 mtrs of length per day on the city side of terminal building T1, T2 & T4, including Admin Building, fly over, carpark area, Lawn & Trees etc., as required as directed by the Engineer-in-Charge.1. Independence day - 3 days2. Diwali - 2 days3. Christmas - 2 days4. New Year - 2 days5. Pongal - 3 days6. Republic Day - 3 days7. Other occasions - 4 Days |
| 6 | Hiring charges for providing 2 Nos. Happy Independence day / Diwali / Christmas / New year / Pongal / Republic Day with matching background colour board having min 4 feet LED letters with suitable size decorated aesthetic looking MS support at Entry/car park area of Domestic and International Terminals etc. complete as required and as per the direction of Engineer-in-charge.1. Independence day - 3 days2. Diwali - 2 days3. Christmas - 2 days4. New Year - 2 days5. Pongal - 3 days6. Republic Day - 3 days |
| 7 | Hiring Charges for providing 3 Nos RGB pixel LED digital board of size 10 feet x 4 feet (one at T1 Terminal Departure, T2 Terminal Departure & T4 Terminal Departure) with a message of Happy Independence day / Diwali / Christmas / New Year / Pongal / Republic day with matching background colour, with required decorated aesthetic looking MS support to withstand against strong winds etc. complete as required and as per the directions of Engineer-in-charge.1. Independence day - 3 days2. Diwali - 2 days3. Christmas - 2 days4. New Year - 2 days5. Pongal - 3 days6. Republic Day - 3 days |
| 8 | Installation and Dismantling of decorative lighting materials at different locations of T1, T2 & T4 Departure, Arrival & Admin Building, car parking areas. Job involves Transportation, loading and unloading etc. of decorative lighting materials, laying, fixing and testing of decorative lighting for different occasions like Independence day, Diwali, New year, Pongal, Republic Day etc. at various locations of Chennai Airport including providing and disconnecting electrical connections etc., removing the decorative lighting materials and clearing the site after completion of work etc. complete as required. |
| 9 | Installation & Dismantling of illuminated super flex boards with connections, frame fabrication works including providing 6/8 feet height stage with decoration etc. as required as per directions of Engineer-in-charge. |
| 10 | a) 8 ft x 6 ft |
| 11 | b) 10 ft x 12 ft |
| 12 | Hiring charges for following multi-colour digitally 3D printed logo with description, untearable, stretchable flex sheet including suitable metal bar with required 200 W LED flood lights for illumination etc. as required and as per the directions of Engineer-in-charge. |
| 13 | a) 8 ft x 6 ft |
| 14 | b) 10 ft x 12 ft |
| 15 | Hiring charges for providing illumination with standard coloured serial LED lamps 2500 sets per day (containing minimum 40 Nos. of lamps per set) on the CISF BARRACKS/ buildings at Pazhavanthangal & Meenambakkam including Lawn & Trees for the following Occasions as required and as per the direction of Engineer-in-Charge.1. Independence day - 3 days2. Diwali - 2 days3. New Year - 2 days4. Republic Day - 3 days5. CISF Raising Day - 1 day |
| 16 | SH II: R&M of Internal & External Electrical Installations on as and when required basis. |
| 17 | Maintenance of High masts (height 20-30 metres) which includes lowering of high mast lantern carriage, checking, adjustment and replacement of all mechanical components like wire rope, trailing cable, drum, winch, power tool etc., if required (Materials will be given by the department). Checking and adjustment of electrical components like cable, luminaries etc., and replace if required and raising the lantern carriage to the top, testing and commissioning etc., as required. |
| 18 | Maintenance of Flag mast (height 30.5 metres) which includes lowering of 30'X20' national flag, checking, adjustment and replacement of all mechanical components like wire rope, trailing cable, drum, winch, power tool etc., if required (Materials will be given by the department). Checking and adjustment of electrical components like cable etc., and replace if required and raising the 30'X20' national flag, checking, adjustment and replacement of all mechanical components like wire rope, trailing cable, drum, winch, power to the top, testing and commissioning etc., as required. |
| 19 | Dismantling the high mast of height above 20.0m and upto 30.5 m from the foundation to replace the damaged pulley / wire rope / trailing cable and reinstallation of the high mast after repair in the same foundation using crane and other appropriate equipments complete as required. |
| 20 | Design and Construction of suitable shallow foundation with anchor plates, templates as per the OEM recommendation of high masts of height above 20.0m and upto 30.0 m i/c fixing of foundation bolts supplied for high mast with M20 grade concrete for above mentioned height high masts after testing the soil bearing capacity at site and installation of high masts on the base using suitable heavy equipments, installation of required No. of LED light fittings / components with switch gear arrangement on the lantern carriage, installation of LED aviation obstruction lights, installation of control panel, interconnecting cables, wiring, testing and commissioning etc., complete as required. |
| 21 | Dismantling of unserviceable winch gear assembly from the high mast, complete overhauling of the winch gear assembly i/c replacement of parts such as shaft, bearing, oil seals and filling up with lubricating oil etc., and re-fixing the winch gear assembly i/c. testing and commissioning etc., as required. |
| 22 | Dismantling of drive motor from the high mast, cleaning, greasing and painting of the motors, reinstallation in the high mast i/c testing and commissioning etc., as required. |
| 23 | Dismantling of unserviceable / burnt out motor of rating upto 1.5HP motor from the high mast. Complete dismantling of burnt out motor stator winding and thorough cleaning of stator slots, Rewinding the stator with Class 'F' polyester coated super enamelled copper wire and insulating materials i/c baking, varnishing, finishing and re-fixing the stator in the motor frame. Replacement of both end bearings and reinstallation in the high mast i/c testing and commissioning etc. as required. (Dismantled copper wire is to be retained by the contractor) |
| 24 | Supply and Installation of 2m x 2m MS Barricade made out of ISMB 150 channel around the high mast with 4 Nos. of ISMB 150 Channels mounting 750mm above ground level and 450mm below ground level for vertical support including excavation of soil, providing 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement concrete and disposal of the excavated soil etc. including welding, painting with one coat of zinc chromate and two coats of polyurethane paint of colour red and white etc. complete as required as per the instructions of Engineer-In-Charge. |
| 25 | Supply and Installation of 2m x 2m MS Barricade made out of ISMB 150 channel around the high mast with 4 Nos. of ISMB 150 Channels mounting 750mm above ground level and 450mm below ground level for vertical support including excavation/dismantling of concrete / bitumen surface of required dia with core cutting machine, providing 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement concrete and disposal of the excavated soil/concrete/bitumen etc. including welding, painting with one coat of zinc chromate and two coats of polyurethane paint of colour red and white etc. complete as required as per the instructions of Engineer-In-Charge. |
| 26 | Dismantling, shifting ,re-installation, testing and commissioning of existing feeder pillar panel including termination etc., making proper pedestal for placing the panel with 1:2:4(1cement : 2 Coarse : 4 graded stone aggregate nominal size) cement concrete etc., complete as required. |
| 27 | Repairing / Servicing of existing LED Exit sign board at T1 & T4 Terminals etc., as required. |
| 28 | SH-III: Supply of following electrical spares on as and when required basis. |
| 29 | Supply of Double drum winch suitable for 25 - 30 m high mast |
| 30 | Supply of Double drum winch suitable for 100 ft flag mast |
| 31 | Supply of Stainless steel wire rope 6mm dia. |
| 32 | Supply of Wire clamps (U type) |
| 33 | Supply of Lantern Carriage resting arm (Set of 3) |
| 34 | Supply of Headframe pulley |
| 35 | Supply of Headframe pulley for flag mast |
| 36 | Supply of Eye Bolt with Clamps |
| 37 | Supply of Drive chain with connecting pins |
| 38 | Supply of Ratchet wheel set (Torque limiter) |
| 39 | Supply of Gear oil SAE 140 (5 Litre Can) (IOCL/ BPCL/ HPCL/ CASTROL make) |
| 40 | Supply of 16A, 5pin splash proof Insulated plug socket set |
| 41 | Supply of LED Aviation Obstruction light, shall have input 240V, 50Hz IP65, suitable for Flag Mast/High mast etc. as required. |
| 42 | Supply of 5C x 4 sqmm copper conductor, EPR insulated, PC tape, PCP outer sheathed Elastomeric Rubber cable of 1.1KV grade for use in high masts as trailing cable. |
| 43 | Supply of 3C x 2.5 sqmm copper conductor, EPR insulated, PC tape, PCP outer sheathed Elastomeric Rubber cable of 1.1KV grade for use in high masts as trailing cable. |
| 44 | Supply of 1.1kW(1.5HP), 415V, 50Hz, 989 RPM (6 pole motor), S1 duty, IP55 with Class F Insulation Energy Efficient, TEFC, Induction motor conforming to IS 12615 for high mast/ Flag mast application with all accessories. |
| 45 | Supply of 1.5kW(2HP), 415V, 50Hz, 989 RPM (6 pole motor), S1 duty, IP55 with Class F Insulation Energy Efficient, TEFC, Induction motor conforming to IS 12615 for high mast drive application with all accessories. |
| 46 | Supply of 12Volt, 45watts, 5 metres length of profile shine LED light Strips 6500K Philips make, model No. 57808 product code: 929003591801, 240LEDs per meter or equivalent. |
| 47 | Supply of input 220Volt/ Output 12Volt Led Light Driver,60W 5A 12V DC of Philip make model No. C060C500V012FNE2AIC2 or its equivalent. |
| 48 | Supply of input 220Volt/ Output 12Volt Led Light Driver, 24W 2A 12V DC of Philip make model No. C024C200V012FNP3AI or its equivalent. |
| 49 | Supply of 4 core x 25 sqmm XLPE insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1KV grade conforming to relevant IS 7098 Part 1 with upto date amendments etc. as required. |
| 50 | Supply of 3.5 core x 35 sqmm XLPE insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1KV grade conforming to relevant IS 7098 Part 1 with upto date amendments etc. as required. |
| 51 | SH-IV: Signages and associated electrical works on as and when required basis. |
| 52 | Facility Announcers - Passenger Amenities |
| 53 | Refer design drawing 1.7dS, 1.7dG |
| 54 | Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. All exterior signs should be manufactured considering harsh outdoor conditions, weatherproofing techniques and materials shall be used. |
| 55 | Sign Box 1 |
| 56 | Providing and fixing sign box all 4 sides with laser cut Bent Fabrication in 8mm thick clear acrylic with pantone yellow C Vinyl pasted over acrylic with white diffuser film on inside face. Blockout vinyl for text Pantone Black 6C. Complete box excluding bottom side is lited with internal LED lighting. Acrylic fabrication shall have transparent structural supports for obstruction free lighting. Box to be directly mounted on the sign structure. |
| 57 | Sign face |
| 58 | Providing and fixing sign face with 3 mm thick Aluminium sheet fabrication with black colour RAL 9011, Aluminium sheet fixed to sign structure with a provision of niche for telephone as specified in the drawings. |
| 59 | Sign Structure |
| 60 | Providing and fixing MS square 50 x 50 x 2 mm fabrication, 50 microns hot dipped galvanised and fixed to the ground. Frame to receive the sign face with 3 mm thick Aluminium sheet fabrication with specific grey colour, Aluminium sheet fixed to sign structure as specified in the drawings. The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together. |
| 61 | Lighting |
| 62 | All internal illumination shall be using Power LED Light strips/modules from Osram or equivalent with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification .Cost to include all internal connections and Wiring, terminating and connecting the incoming cable at the site. |
| 63 | Foundation |
| 64 | Providing and fixing signboard in position and sturdy on existing floor by suitable size anchor fasteners(Anti Corrosive type) and fixing in position electrical connection wherever applicable and finished as per drawing. The item cost includes cutting and opening the floor finish at location, and making good the location to the match the original finish after fixing and installation of sign. |
| 65 | Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing. |
| 66 | Ceiling Hung Directional Sign |
| 67 | Refer design drawing 2.1aS, 2.1aG |
| 68 | Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. |
| 69 | Sign face |
| 70 | Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone yellow C or Cyan 311C as per graphics (Wherever Single side content provided then other side also to be provided with 5 mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl shall match colour Pantone Black 6C The sign height shall be equal to the message panel height used i.e. multiple of 255mm and of specified make duly approved by the Engineer-in-Charge. |
| 71 | Sign Frame |
| 72 | Providing and fixing sign frame 50mm wide Powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with 3M brand dual lock system in one side and 3M both way tape from the other side. The panel should be made easily openable for maintenance. |
| 73 | Sign internal Structure |
| 74 | Providing and fixing Framework of Aluminium 25mmx 25mm x 1.5 hollow square sections. Shall be directly fixed to the sign frame. |
| 75 | Suspender |
| 76 | Providing and fixing Stainless steel 32mmx32mmx2mm Hollow sections (assuming typical length of 1 metre) mounted on slabs/beams/walls. All hardware used for fixing of sign shall be Stainless steel. The item cost includes cutting and opening of various types of false at location, and making good the location to the match the original finish after fixing and installation of sign. |
| 77 | Lighting |
| 78 | All internal illumination shall be using Power LED Light strips/modules from Osram or equivalent ( Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable at the site. The number of LED strips / modules and electronic controllers shall vary as per number of messages in sign board to the satisfactory illumination of sign boards. |
| 79 | The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together. |
| 80 | Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing. |
| 81 | Message 1 (Single Side) |
| 82 | Message 1 (Double Side) |
| 83 | Message 2 (Single Side) |
| 84 | Message 2 (Double Side) |
| 85 | Message 3 (Single Side) |
| 86 | Message 3 (Double Side) |
| 87 | Message 4 (Single Side) |
| 88 | Message 4 (Double Side) |
| 89 | Floor mounted directional sign - Without FIDS |
| 90 | Refer design drawing 2.1b-1S, 2.1b-1G |
| 91 | Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. |
| 92 | Sign face |
| 93 | Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone yellow C or Cyan 311C as per graphics (Wherever Single side content provided then other side also to be provided with 5 mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl shall match colour Pantone Black 6C).The sign panel height shall be equal to the message panel height used i.e. multiple of 255mm and of specified make duly approved by the Engineer-in-Charge. |
| 94 | Sign Frame |
| 95 | Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system in one side and 3M both way tape from the other side. The panel should be made easily openable for maintenance. |
| 96 | Sign Structure |
| 97 | All structural members in SS square post 100 x 100 x 3mm and horizontal cross tie member square sections 50x50x2mm, brush finished. base plate embedded below the floor finish and provided with a floor trim ring. All hardware used for fixing of sign shall be Stainless steel. Post including SS base Plate and Gussets in 6mm thick SS Plate as per drawing with holes to fix it on holding down bolts anchored in concrete slab. The post shall closed with a 3 mm thick SS plate as specified and approved by the Engineer-In-charge. The Post shall be always be a single continuous element without any joints. Cost to include all activities and temporary props used for a perfect vertical in plumb installation, etc. required for fixing the sign in an internal location. The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together. |
| 98 | Lighting |
| 99 | All internal illumination shall be using Power LED Light strips/modules from Osram or equivalent ( Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable at the site. The number of LED strips / modules and electronic controllers shall vary as per number of messages in sign board to the satisfactory illumination of sign boards. |
| 100 | The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together. |
| 101 | Foundation |
| 102 | Providing and fixing SS Posts in position and sturdy on existing RCC floor below the granite by using suitable size anchor fasteners(Anti Corrosive type) and finished as per drawing. The item cost includes cutting and opening the floor granite/marble/tile etc finish at location, and making good the location to the match the original finish after fixing and installation of sign. |
| 103 | Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing. |
| 104 | Message 3 (Single Side) |
| 105 | Message 3 (Double Side) |
| 106 | Message 4 (Single Side) |
| 107 | Message 4 (Double Side) |
| 108 | Message 5 (Single Side) |
| 109 | Message 5 (Double Side) |
| 110 | Floor mounted directional sign - With Maps |
| 111 | Refer design drawing 2.1b-2S, 2.1b-2G |
| 112 | Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. |
| 113 | Sign face |
| 114 | Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone yellow C or Cyan 311C as per graphics (Wherever Single side content provided then other side also to be provided with 5 mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl shall match colour Pantone Black 6C).The sign panel Height shall be equal to the message panel height used. i.e. multiple of 255mm and of specified make duly approved by the Engineer-in-Charge. |
| 115 | Sign Frame |
| 116 | Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system in one side and 3M both way tape from the other side. The panel should be made easily openable for maintenance. |
| 117 | Sign internal Structure |
| 118 | Providing and fixing Framework of Aluminium 25mmx 25mm x 1.5 mm hollow square sections. Shall be directly fixed to the sign frame. |
| 119 | Sign Structure |
| 120 | All structural members in SS square post 100 x 100 x 3 mm and horizontal cross tie member square sections 50x50x 2.5mm brush finished, base plate embedded below the floor finish and provided with a floor trim ring. All hardware used for fixing of sign shall be Stainless steel. Post including SS base Plate and Gussets in 6mm thick SS Plate as per drawing with holes to fix it on holding down bolts anchored in concrete slab. The post shall closed with a 3 mm thick SS plate as specified and approved by the Engineer-In-charge. The Post shall be always be a single continuous element without any joints. Cost to include all activities and temporary props used for a perfect vertical in plumb installation, etc. required for fixing the sign in an internal location.The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together. |
| 121 | Information Panel |
| 122 | Providing and fixing 50 mm wide Aluminium extrusion openable secure frames with printed graphic behind 4mm clear Polycarbonate.Secret fixing methods should be used to fix parts together (rear side also to be provided with 4 mm thick Polycarbonate (as specified) having graphics pasted in Plotter cut Blockout vinyl shall match colour Pantone Black 6C.) |
| 123 | Lighting |
| 124 | All internal illumination shall be using Power LED Light strips/modules from Osram or equivalent (Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable laid by Airport contractor at the site. The number of LED strips / modules and electronic controllers will vary as per number of messages in sign board and to the satisfaction of the Engineer-in-Charge. |
| 125 | The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together. |
| 126 | Foundation |
| 127 | Providing and fixing SS Posts in position and sturdy on existing RCC floor below the granite by using suitable size anchor fasteners(Anti Corrosive type) and fixing in position electrical connection wherever applicable and finished as per drawing. The item cost includes cutting and opening the floor granite/marble/tile etc. finish at location, and making good the location to the match the original finish after fixing and installation of sign. |
| 128 | Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing. |
| 129 | Message 3 (Single side) |
| 130 | Message 3 (Double Side) |
| 131 | Message 4 (Single side) |
| 132 | Message 4 (Double Side) |
| 133 | Message 5 (Single side) |
| 134 | Message 5 (Double Side) |
| 135 | Floor mounted directional sign - Single |
| 136 | Refer design drawing 2.1b-3S, 2.1b-3G |
| 137 | Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. |
| 138 | Sign face |
| 139 | Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone yellow C or Cyan 311C as per graphics (Wherever Single side content provided then other side also to be provided with 5 mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl shall match colour Pantone Black 6C).The sign panel Height shall be equal to the message panel height used. i.e. multiple of 255mm and of specified make duly approved by the Engineer-in-Charge. |
| 140 | Sign Frame |
| 141 | Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system in one side and 3M both way tape from the other side. The panel should be made easily openable for maintenance. |
| 142 | Sign internal Structure |
| 143 | Providing and fixing Framework of Aluminium 25mmx 25mm x 1.5 mm hollow square sections. Shall be directly fixed to the sign frame. |
| 144 | Sign Structure |
| 145 | All structural members in SS square post 100 x 100 x 3 mm, brush finished. base plate embedded below the floor finish and provided with a floor trim ring. All hardware used for fixing of sign shall be Stainless steel. Post including SS base Plate and Gussets in 6mm thick SS Plate as per drawing with holes to fix it on holding down bolts anchored in concrete slab. The post shall closed with a 3 mm thick SS plate as specified and approved by the Engineer-In-charge. The Post shall be always be a single continuous element without any joints. Cost to include all activities and temporary props used for a perfect vertical in plumb installation, etc. required for fixing the sign in an internal location.The actual structural design of the sign for its stability shall be ensued. Secret fixing methods should be used to fix parts together. |
| 146 | Tension Rod |
| 147 | Providing and fixing tension rod of dia 10mm in brush finished S.S. with the turn buckle system. Tension rod shall be fixed to the sign structure and the sign frame with S.S. gusset plates. |
| 148 | Lighting |
| 149 | All internal illumination shall be using Power LED Light strips/modules from Osram or equivalent (Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable at the site. The number of LED strips / modules and electronic controllers shall vary as per number of messages in sign board to the satisfactory illumination of sign boards. |
| 150 | The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together. |
| 151 | Foundation |
| 152 | Providing and fixing SS Post in position and sturdy on existing RCC floor below the granite by using suitable size anchor fasteners(Anti Corrosive type) and finished as per drawing. The item cost includes cutting and opening the floor granite/marble/tile etc. finish at location, and making good the location to the match the original finish after fixing and installation of sign. |
| 153 | Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing. |
| 154 | Message 1 (Single Side Content either LHS or RHS of Pole) |
| 155 | Message 2 (Single Side Content either LHS or RHS of Pole) |
| 156 | Message 3 (Single Side Content either LHS or RHS of Pole) |
| 157 | Message 4 (Single Side Content either LHS or RHS of Pole) |
| 158 | Message 5 (Single Side Content either LHS or RHS of Pole) |
| 159 | Floor mounted directional sign - Double |
| 160 | Refer design drawing 2.1b-4S, 2.1b-4G |
| 161 | Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. |
| 162 | Sign face |
| 163 | Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone yellow C or Cyan 311C as per graphics (Wherever Single side content provided then other side also to be provided with 5 mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl shall match colour Pantone Black 6C).The sign panel Height shall be equal to the message panel height used. i.e. multiple of 255mm and of specified make duly approved by the Engineer-in-Charge. |
| 164 | Sign Frame |
| 165 | Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system in one side and 3M both way tape from the other side. The panel should be made easily openable for maintenance. |
| 166 | Sign internal Structure |
| 167 | Providing and fixing Framework of Aluminium 25mmx 25mm x 1.5 mm hollow square sections. Shall be directly fixed to the sign frame. |
| 168 | Sign Structure |
| 169 | All structural members in SS square post 100 x 100 x 3 mm, brush finished. base plate embedded below the floor finish and provided with a floor trim ring. All hardware used for fixing of sign shall be Stainless steel. Post including SS base Plate and Gussets in 6mm thick SS Plate as per drawing with holes to fix it on holding down bolts anchored in concrete slab. The post shall closed with a 3 mm thick SS plate as specified and approved by the Engineer-In-charge. The Post shall be always be a single continuous element without any joints. Cost to include all activities and temporary props used for a perfect vertical in plumb installation, etc. required for fixing the sign in an internal location.The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together. |
| 170 | Tension Rod |
| 171 | Providing and fixing tension rod of dia 10mm in brush finished S.S. with the turn buckle system. Tension rod shall be fixed to the sign structure and the sign frame with S.S. gusset plates. |
| 172 | Lighting |
| 173 | All internal illumination shall be using Power LED Light strips/modules from Osram or equivalent (Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable at the site. The number of LED strips / modules and electronic controllers shall vary as per number of messages in sign board to the satisfactory illumination of sign boards. |
| 174 | The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together. |
| 175 | Foundation |
| 176 | Providing and fixing SS Post in position and sturdy on existing RCC floor below the granite by using suitable size anchor fasteners(Anti Corrosive type) and finished as per drawing. The item cost includes cutting and opening the floor granite/marble/tile etc. finish at location, and making good the location to the match the original finish after fixing and installation of sign. |
| 177 | Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing. |
| 178 | Message 3 (Single Side content on LHS & RHS of Pole) |
| 179 | Message 3 (Double Side content on LHS & RHS of Pole) |
| 180 | Wall mounted Directional Sign |
| 181 | Refer design drawing 2.1c-S, 2.1c-G |
| 182 | Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. |
| 183 | Sign face |
| 184 | Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone yellow C or Cyan 311C as per graphics and of specified make duly approved by the Engineer-in-Charge. The sign panel height shall be equal to the message panel height used i.e. multiple of 255mm. |
| 185 | Sign Frame |
| 186 | Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system in one side and 3M both way tape from the other side. The panel should be made easily openable for maintenance. |
| 187 | Sign internal Structure |
| 188 | Providing and fixing Framework of Aluminium 25mmx 25mm x 1.5mm hollow square sections. Shall be directly fixed to the sign frame. |
| 189 | Lighting |
| 190 | All internal illumination shall be using Power LED Light strips/modules from Osram or equivalent (Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable laid by Airport contractor at the site. The number of LED strips / modules and electronic controllers shall vary as per number of messages in sign board to the satisfactory illumination of Sign Board. |
| 191 | The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together. |
| 192 | Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing. |
| 193 | Message 1 (Single Side) |
| 194 | Message 2 (Single Side) |
| 195 | Message 3 (Single Side) |
| 196 | Message 4 (Single Side) |
| 197 | Message 5 (Single Side) |
| 198 | Wall Projected Directional Sign |
| 199 | Refer design drawing 2.1d-S, 2.1d-G |
| 200 | Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. |
| 201 | Sign face |
| 202 | Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone yellow C or Cyan 311C as per graphics (Wherever Single side content provided then other side also to be provided with 5 mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl shall match colour Pantone Black 6C).The sign panel height shall be equal to the message panel height used i.e. multiple of 255mm and of specified make duly approved by the Engineer-in-Charge. |
| 203 | Sign Frame |
| 204 | Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system in one side and 3M both way tape from the other side. The panel should be made easily openable for maintenance. |
| 205 | Sign internal Structure |
| 206 | Providing and fixing Framework of Aluminium 25mmx 25mm x1.5mm hollow square sections. Shall be directly fixed to the sign frame. |
| 207 | Tension Rod |
| 208 | Providing and fixing tension rod of 10 mm dia in brush finished S.S. with the turn buckle system. Tension rod shall be fixed to the wall structure and the sign frame with S.S. gusset plates. |
| 209 | Lighting |
| 210 | All internal illumination shall be using Power LED Light strips/modules from Osram or equivalent (Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable at the site. The number of LED strips / modules and electronic controllers shall vary as per number of messages in sign board to the satisfactory illumination of Sign boards. |
| 211 | The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together. |
| 212 | Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing. |
| 213 | Message 1 (Double Side Either LHS or RHS of Column/Wall/Steel Structure) |
| 214 | Message 2 (Double Side Either LHS or RHS of Column/Wall/Steel Structure) |
| 215 | Message 3 (Double Side Either LHS or RHS of Column/Wall/Steel Structure) |
| 216 | Wall Mounted Facility Announcer |
| 217 | Refer design drawing 2.2a-S, 2.2a-G |
| 218 | Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. |
| 219 | Sign face |
| 220 | Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone yellow C or Cyan 311C as per graphics (Wherever Single side content provided then other side shall be provided with ACP) and of specified make duly approved by the Engineer-in-Charge. |
| 221 | Sign Frame |
| 222 | Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system in one side and 3M both way tape from the other side. The panel should be made easily openable for maintenance. |
| 223 | Lighting |
| 224 | All internal illumination shall be using Power LED Lights from Osram or equivalent (Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable at the site. |
| 225 | The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together. |
| 226 | Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing. |
| 227 | Wall Projected Facility Announcer |
| 228 | Refer design drawing 2.2b-S, 2.2b-G |
| 229 | Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. |
| 230 | Sign face |
| 231 | Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone yellow C or Cyan 311C as per graphics and of specified make duly approved by the Engineer-in-Charge. (Double Side) |
| 232 | Sign Frame |
| 233 | Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system in one side and 3M both way tape from the other side. The panel should be made easily openable for maintenance. |
| 234 | Lighting |
| 235 | All internal illumination shall be using Power LED Lights from Osram or equivalent (Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable at the site. |
| 236 | The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together. |
| 237 | Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing. |
| 238 | Boarding Gates - Totem Without Information panel/ FIDS |
| 239 | Refer design drawing 2.2g-1-S, 2.2g-1-G |
| 240 | Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. (Signboard should have provision of opening for maintenance) |
| 241 | Sign Box |
| 242 | Providing and fixing sign box with laser cut Bent Fabrication in 5mm thick clear acrylic with pantone yellowC Vinyl pasted on it. Complete box excluding bottom side is lited with internal LED lighting. Acrylic fabrication shall have transparent structural supports for obstruction free lighting. Box to be directly mounted on the sign structure. Text in opaque black vinyl to match RAL 9011 |
| 243 | Sign Face |
| 244 | Providing and fixing sign face panels 3 mm thick Aluminium sheet fabrication, Aluminium sheet fixed to sign structure with black colour RAL 9011 with a provision of through and through laser cutting for information panel and text with pantone yellowC Vinyl. Backlit Text with 5mm thick milky white acrylic flushed with the sign face. Bottom structure to be finished in 3 mm thick Aluminium sheet fabrication with grey colour RAL 9006 and directly fixed to the sign structure. |
| 245 | Sign Structure |
| 246 | Providing and fixing MS square post 50x50x2.5mm fabrication, 50 microns hot dipped galvanised and fixed to the ground. Frame to receive the sign faces.The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together. |
| 247 | Crash Guard |
| 248 | Providing and fixing Protection for sign from trollies, wheeled baggage in 18 SWG stainless steel pipe 2mm dia brush finished fixed with 6mm thick SS plate bracket. |
| 249 | Lighting |
| 250 | All internal illumination shall be using Power LED Lights from Osram or equivalent ( Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting with the incoming cable at the site. |
| 251 | Foundation |
| 252 | Providing and fixing of MS Posts of Signboard in position and sturdy on existing floor by suitable size anchor fasteners(Anti Corrosive type) and finished as per drawing. The item cost includes cutting and opening the floor finish at location, and making good the location to the match the original finish after fixing and installation of sign |
| 253 | Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing.>> |
| 254 | Boarding Gates - Wall Projected |
| 255 | Refer design drawing 2.2g-2-S, 2.2g-2-G |
| 256 | Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. |
| 257 | Sign face |
| 258 | Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective over laminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone yellow C or Cyan 311C as per graphics and of specified make duly approved by the Engineer-in-Charge. |
| 259 | Sign Frame |
| 260 | Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system in one side and 3M both way tape from the other side. The panel should be made easily openable for maintenance. |
| 261 | Lighting |
| 262 | All internal illumination shall be using Power LED Lights from Osram or equivalent (Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable at the site. |
| 263 | The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together. |
| 264 | Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing. |
| 265 | Boarding Gates - Wall Mounted (Modified) without Information panel/ FIDS |
| 266 | Refer design drawing 2.2g3-S, 2.2g3-G (modified) |
| 267 | Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. (Wherever Single side content provided then other side shall be provided with ACP) |
| 268 | Sign face |
| 269 | Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone yellow C or Cyan 311C as per graphics with a provision of through and through cut out for information panel and of specified make duly approved by the Engineer-in-Charge. |
| 270 | Sign Frame |
| 271 | Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system. The panel should be made easily openable for maintenance. |
| 272 | Sign internal Structure |
| 273 | Providing and fixing Framework of Aluminium 25mmx 25mm x1.5 mm hollow square sections. Shall be directly fixed to the sign frame. |
| 274 | Lighting |
| 275 | All internal illumination shall be using Power LED Lights from Osram or equivalent (Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable at the site. |
| 276 | The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together. |
| 277 | Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing. |
| 278 | Airport zonal route Map - Interiors |
| 279 | Refer design drawing 2.3a-S, 2.3a-G |
| 280 | Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. (Wherever Single side content provided then other side also to be provided with 5 mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl shall match colour Pantone Black 6C) |
| 281 | Sign Face |
| 282 | Providing and fixing sign face panel in 5mm thick white translucent 040 acrylic. Graphics - Plotter cut blockout vinyl pantone black C, translucent printed vinyl for text / Map and pasted over white translucent acrylic. |
| 283 | Sign Frame |
| 284 | Providing and fixing sign frame of 50mm wide powder coated, colour RAL 9006 aluminium extrusion with inbuilt frame to receive the sign face. The panel should be made easily openable from back for maintenance. |
| 285 | Sign Structure |
| 286 | SS square post 70x70X3 mm and horizontal square sections 50 x 50 X 2 mm mm Post including SS base Plate in 6mm thick as per drawing with holes to fix it on holding down bolts anchored in concrete footing. The post shall closed with a 3 mm thick SS plate The post shall closed with a 3 mm thick MS plate and parts kept unpainted to weld the sign structure as per the drawing to ensure a rigid connection at site. The entire post assembly shall be hot dipped galvanised and P.U. Painted to match RAL 9006 as specified and approved by the Engineer-In-charge. The Post shall be always be a single continuous element without any joints. Cost to include all activities and temporary props used for a perfect vertical in plumb installation, shim Plates for adjustment of levels and filling the gap with concrete slurry etc. required for fixing the sign in an external location.The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together. 225x225mm size, 5 mm thick cover plate mounted in case the flooring is present. |
| 287 | Lighting |
| 288 | All internal illumination shall be using Power LED Lights from Osram or equivalent ( Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable at the site. |
| 289 | Foundation |
| 290 | Providing and fixing SS Posts in position and sturdy on existing RCC floor below the granite by using suitable size anchor fasteners(Anti Corrosive type) and finished as per drawing. The item cost includes cutting and opening the floor granite/marble/tile etc. finish at location, and making good the location to the match the original finish after fixing and installation of sign |
| 291 | Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing. |
| 292 | Lift Directory |
| 293 | Refer design drawing 2.3b-S, 2.3b-G |
| 294 | Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge.(Wherever Single side content provided then other side shall be provided with 3 mm thick ACP) |
| 295 | Sign face |
| 296 | Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone yellow C or Cyan 311C as per graphics and of specified make duly approved by the Engineer-in-Charge. |
| 297 | Sign Frame |
| 298 | Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system. The panel should be made easily openable for maintenance. |
| 299 | Lighting |
| 300 | All internal illumination shall be using Power LED Lights from Osram or equivalent ( Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting with the incoming cable at the site. |
| 301 | The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together. |
| 302 | Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing. |
| 303 | Washroom / Drinking Water / Baby care |
| 304 | Refer design drawing 2.4a-S, 2.4a-G |
| 305 | Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge.(Wherever Single side content provided then other side shall be provided with 3 mm thick ACP) |
| 306 | Sign face |
| 307 | Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone Cyan 311C as per graphics and of specified make duly approved by the Engineer-in-Charge. |
| 308 | Sign Frame |
| 309 | Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system in one side and 3M both way tape from the other side. The panel should be made easily openable for maintenance. |
| 310 | Lighting |
| 311 | All internal illumination shall be using Power LED Lights from Osram or equivalent (Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting with the incoming cable at the site. |
| 312 | The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together. |
| 313 | Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing. |
| 314 | Wall Projected (Double Side - Sign face in acrylic) |
| 315 | Wall mounted (Single side content - Sign Face: acrylic, and Back: 3mm ACP) |
| 316 | Lift No. Sign |
| 317 | Refer design drawing 2.4c-S, 2.4c-G |
| 318 | Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge.(All the wall mount signs shall be provided with 3 mm thick ACP at the back) |
| 319 | Sign face |
| 320 | Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone Cyan 311C as per graphics and of specified make duly approved by the Engineer-in-Charge. |
| 321 | Sign Frame |
| 322 | Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system. The panel should be made easily openable for maintenance. |
| 323 | Lighting |
| 324 | All internal illumination shall be using Power LED Lights from Osram or equivalent (Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting with the incoming cable at the site. |
| 325 | The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together. |
| 326 | Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing. |
| 327 | Wall Projected (Double Side - Sign face in acrylic) |
| 328 | Wall mounted (Single side content - Sign Face: acrylic, and Back: 3mm ACP) |
| 329 | Emergency Direction Signs - Illuminated |
| 330 | Refer design drawing 2.6a-G |
| 331 | Providing and fixing illuminated emergency signs (having min.1.5 hrs backup time) including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. |
| 332 | Sign face |
| 333 | Sign face shall be made in 5mm thick Laminated acrylic (as specified) having graphics pasted on the inside with translucent white vinyl pasted over plotter cut Translucent vinyl. The Plotter cut translucent vinyl to match the specified colour and of specified make duly approved by the Engineer-in-Charge. (As per design drawings, Emergency signs are in various sizes, single sided for wall/face mounted and double sided for Ceiling hung/wall projected/floor mounted) |
| 334 | Suspender for ceiling hung |
| 335 | Providing and fixing Stainless steel 32 x 32 mm x 2 mm Hollow sections (assuming typical length of 1 metre) mounted on slabs/beams/walls. All hardware used for fixing of sign shall be Stainless steel. The item cost includes cutting and opening of various types of false at location, and making good the location to the match the original finish after fixing and installation of sign. |
| 336 | Sign Box |
| 337 | The sign box 80 mm deep shall be made out of 1.6 mm thick CRCA MS sheet fabricated and provided with same material support channel and ties welded to sign channel. All fabrication shall be done using CNC machines. Sign box shall be provided with openings with Mesh from inside for ventilation. Complete sign box including channel supports are to be powder coated to match RAL9016. Sign box flange receiving the sign face shall be provided with slots to receive the rivets to fix the sign frame. |
| 338 | Lighting |
| 339 | All internal illumination shall be using Power LED Lights from Osram or equivalent with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable laid by Airport contractor at the site. |
| 340 | Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing. |
| 341 | Emergency Exit |
| 342 | Providing and Fixing of computerised 3M vinyl cut text of approved matter in three language with directional sign etc., in double colour on existing 5mm thick Polycarbonate sheet of different sizes on existing signages including dismantling of existing polycarbonate sheet board from the existing signage board and remove the existing signage vinyl sticker over the polycarbonate sheet including cleaning of the complete polycarbonate surface without causing any damage and scratch over the surface and re-fixing the polycarbonate sheet on the existing sign board etc., as per direction of Engineer-in-Charge complete as required.Note: In case of any breakage of Polycarbonate sheets during dismantling, shifting, handling & re-fixing etc., the complete sheet to be replaced by contractor at free of cost. |
| 343 | Providing and fixing of new Airline logo sticker at city side departure level airline listing announcer board as per direction of Engg-in-charge. |
| 344 | Providing and fixing of computerized poly vinyl sticker with blue background and white letters have self adhesive type complete as required and as per direction of Engg-in-charge. |
| 345 | Supply, assembly and laying of under floor trunking made out of 1.6mm(min) thick GI sheet complete with jointing sleeve, horizontal bends, vertical bends, level adjustment components and closer, vertical elbow, covers, access outlet. etc. complete with all other accessories under floor installation, making good the same, placing in position and cleaning from inside complete etc. as required. |
| 346 | a) 150 mm wide x 38 mm deep raceway (1 compartment) |
| 347 | b) 50 mm wide x 38 mm deep raceway (1 compartment) |
| 348 | Providing and fixing 300 x 300 x 50-70 mm deep GI (hot dip galvanized) cross over box made out of 1.6 mm thick sheet steel cross over box in under floor installation in complete as required as per specification. |
| 349 | Providing and fixing 225 x 225 x 50-70 mm deep GI (hot dip galvanized) cross over box made out of 1.6 mm thick sheet steel junction box in under floor installation in complete as required as per specification. |
| 350 | Providing and fixing 150 x 150 x 50-70 mm deep GI (hot dip galvanized) cross over box made out of 1.6 mm thick sheet steel junction box under floor installation in complete as required as per specification. |
| 351 | Supply and fixing of pop up type metal flush mounting box (floor mounted) on floor including Switch & sockets, connection & accessories etc. as required. |
| 352 | a) 3 Module ( 6 amps ) (Similar to Legrand Cat No. 0540 10or Equivalent) |
| 353 | b) 6 Module ( 6/16 amps) (Similar to Legrand Cat No. 0540 12 or Equivalent) |
| 354 | Supply and fixing of pop up type metal flush mounting box (Furniture Mounted)including Switch & sockets, connection & accessories etc. as required. |
| 355 | a) 4 Module ( 6/16 amps) (Similar to Legrand Cat No. 6540 14 or Equivalent) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender