Civil Aviation Boards / Undertakings / PSU Closing in 15 days TDR #58532611

Tender For Annual Rate Contract For Providing Way Finding Signages And Associated Electrical Works Including Providing Decorative Lighting For Terminal Building & Carpark Area Of T1, T2 & T4 In View Of Festival / Occasions And Supply Of Electrical Sp

Issued by Boards / Undertakings / PSU · Chennai, Tamil Nadu
Tender Value
2.85 Crore
Estimated cost
Bid Submission
07 Dec 2026
15 days left
EMD
5.70 Lakhs
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Annual Rate Contract For Providing Way Finding Signages And Associated Electrical Works Including Providing Decorative Lighting For Terminal Building & Carpark Area Of T1, T2 & T4 In View Of Festival / Occasions And Supply Of Electrical Spares And Other Miscellaneous Works At Chennai International Airport.

BOQ

Name of Work:- Annual Rate contract for providing way finding signages and associated electrical works including providing decorative lighting for Terminal Building & carpark area of T1, T2 & T4 in view of Festival / occasions and Supply of Electrical Spares and other miscellaneous works at Chennai International Airport.
Sl. No. Item Description
1SH-I: Decorative Lighting Common for all Festivals / Occasions.
2Hiring charges for providing illumination with standard coloured serial LED lamps 15,000 sets per day (containing minimum 40 Nos. of lamps per set) on the city side of terminal buildings T1, T2 & T4 including Admin Building, fly over, carpark area, Lawn & Trees for the following Occasions as required and as per the direction of Engineer-in-Charge.1. Independence day - 3 days2. Diwali - 2 days3. Christmas - 2 days4. New Year - 2 days5. Pongal - 3 days6. Republic Day - 3 days7. Other occasions - 4 Days
3Hiring charges for providing illumination with multicolour LED colour wash flood lights 500 nos per day with required cables & all accessories to illuminate the facia of terminals T1, T2, T4 & Admin Building to create bright & colourful ambience for the following Occasions as required and as per the direction of Engineer-in-Charge.1. Independence day - 3 days2. Diwali - 2 days3. Christmas - 2 days4. New Year - 2 days5. Pongal - 3 days6. Republic Day - 3 days7. Other occasions - 4 Days
4Hiring charges for providing illumination with RGB pixel digital serial lighting LED lamps 2,000 sets per day (containing minimum 40 Nos. of lamps per set) on the city side of terminal building T1, T2 & T4, including Admin Building, fly over, carpark area, Lawn, admin building, V&Y type columns of buildings etc. for the following Occasions as required and as per the direction of Engineer-in-Charge.1. Independence day - 3 days2. Diwali - 2 days3. Christmas - 2 days4. New Year - 2 days5. Pongal - 3 days6. Republic Day - 3 days7. Other occasions - 4 Days
5Hiring charges for providing illumination with LED strip Lights 1500 mtrs of length per day on the city side of terminal building T1, T2 & T4, including Admin Building, fly over, carpark area, Lawn & Trees etc., as required as directed by the Engineer-in-Charge.1. Independence day - 3 days2. Diwali - 2 days3. Christmas - 2 days4. New Year - 2 days5. Pongal - 3 days6. Republic Day - 3 days7. Other occasions - 4 Days
6Hiring charges for providing 2 Nos. Happy Independence day / Diwali / Christmas / New year / Pongal / Republic Day with matching background colour board having min 4 feet LED letters with suitable size decorated aesthetic looking MS support at Entry/car park area of Domestic and International Terminals etc. complete as required and as per the direction of Engineer-in-charge.1. Independence day - 3 days2. Diwali - 2 days3. Christmas - 2 days4. New Year - 2 days5. Pongal - 3 days6. Republic Day - 3 days
7Hiring Charges for providing 3 Nos RGB pixel LED digital board of size 10 feet x 4 feet (one at T1 Terminal Departure, T2 Terminal Departure & T4 Terminal Departure) with a message of Happy Independence day / Diwali / Christmas / New Year / Pongal / Republic day with matching background colour, with required decorated aesthetic looking MS support to withstand against strong winds etc. complete as required and as per the directions of Engineer-in-charge.1. Independence day - 3 days2. Diwali - 2 days3. Christmas - 2 days4. New Year - 2 days5. Pongal - 3 days6. Republic Day - 3 days
8Installation and Dismantling of decorative lighting materials at different locations of T1, T2 & T4 Departure, Arrival & Admin Building, car parking areas. Job involves Transportation, loading and unloading etc. of decorative lighting materials, laying, fixing and testing of decorative lighting for different occasions like Independence day, Diwali, New year, Pongal, Republic Day etc. at various locations of Chennai Airport including providing and disconnecting electrical connections etc., removing the decorative lighting materials and clearing the site after completion of work etc. complete as required.
9Installation & Dismantling of illuminated super flex boards with connections, frame fabrication works including providing 6/8 feet height stage with decoration etc. as required as per directions of Engineer-in-charge.
10a) 8 ft x 6 ft
11b) 10 ft x 12 ft
12Hiring charges for following multi-colour digitally 3D printed logo with description, untearable, stretchable flex sheet including suitable metal bar with required 200 W LED flood lights for illumination etc. as required and as per the directions of Engineer-in-charge.
13a) 8 ft x 6 ft
14b) 10 ft x 12 ft
15Hiring charges for providing illumination with standard coloured serial LED lamps 2500 sets per day (containing minimum 40 Nos. of lamps per set) on the CISF BARRACKS/ buildings at Pazhavanthangal & Meenambakkam including Lawn & Trees for the following Occasions as required and as per the direction of Engineer-in-Charge.1. Independence day - 3 days2. Diwali - 2 days3. New Year - 2 days4. Republic Day - 3 days5. CISF Raising Day - 1 day
16SH II: R&M of Internal & External Electrical Installations on as and when required basis.
17Maintenance of High masts (height 20-30 metres) which includes lowering of high mast lantern carriage, checking, adjustment and replacement of all mechanical components like wire rope, trailing cable, drum, winch, power tool etc., if required (Materials will be given by the department). Checking and adjustment of electrical components like cable, luminaries etc., and replace if required and raising the lantern carriage to the top, testing and commissioning etc., as required.
18Maintenance of Flag mast (height 30.5 metres) which includes lowering of 30'X20' national flag, checking, adjustment and replacement of all mechanical components like wire rope, trailing cable, drum, winch, power tool etc., if required (Materials will be given by the department). Checking and adjustment of electrical components like cable etc., and replace if required and raising the 30'X20' national flag, checking, adjustment and replacement of all mechanical components like wire rope, trailing cable, drum, winch, power to the top, testing and commissioning etc., as required.
19Dismantling the high mast of height above 20.0m and upto 30.5 m from the foundation to replace the damaged pulley / wire rope / trailing cable and reinstallation of the high mast after repair in the same foundation using crane and other appropriate equipments complete as required.
20Design and Construction of suitable shallow foundation with anchor plates, templates as per the OEM recommendation of high masts of height above 20.0m and upto 30.0 m i/c fixing of foundation bolts supplied for high mast with M20 grade concrete for above mentioned height high masts after testing the soil bearing capacity at site and installation of high masts on the base using suitable heavy equipments, installation of required No. of LED light fittings / components with switch gear arrangement on the lantern carriage, installation of LED aviation obstruction lights, installation of control panel, interconnecting cables, wiring, testing and commissioning etc., complete as required.
21Dismantling of unserviceable winch gear assembly from the high mast, complete overhauling of the winch gear assembly i/c replacement of parts such as shaft, bearing, oil seals and filling up with lubricating oil etc., and re-fixing the winch gear assembly i/c. testing and commissioning etc., as required.
22Dismantling of drive motor from the high mast, cleaning, greasing and painting of the motors, reinstallation in the high mast i/c testing and commissioning etc., as required.
23Dismantling of unserviceable / burnt out motor of rating upto 1.5HP motor from the high mast. Complete dismantling of burnt out motor stator winding and thorough cleaning of stator slots, Rewinding the stator with Class 'F' polyester coated super enamelled copper wire and insulating materials i/c baking, varnishing, finishing and re-fixing the stator in the motor frame. Replacement of both end bearings and reinstallation in the high mast i/c testing and commissioning etc. as required. (Dismantled copper wire is to be retained by the contractor)
24Supply and Installation of 2m x 2m MS Barricade made out of ISMB 150 channel around the high mast with 4 Nos. of ISMB 150 Channels mounting 750mm above ground level and 450mm below ground level for vertical support including excavation of soil, providing 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement concrete and disposal of the excavated soil etc. including welding, painting with one coat of zinc chromate and two coats of polyurethane paint of colour red and white etc. complete as required as per the instructions of Engineer-In-Charge.
25Supply and Installation of 2m x 2m MS Barricade made out of ISMB 150 channel around the high mast with 4 Nos. of ISMB 150 Channels mounting 750mm above ground level and 450mm below ground level for vertical support including excavation/dismantling of concrete / bitumen surface of required dia with core cutting machine, providing 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement concrete and disposal of the excavated soil/concrete/bitumen etc. including welding, painting with one coat of zinc chromate and two coats of polyurethane paint of colour red and white etc. complete as required as per the instructions of Engineer-In-Charge.
26Dismantling, shifting ,re-installation, testing and commissioning of existing feeder pillar panel including termination etc., making proper pedestal for placing the panel with 1:2:4(1cement : 2 Coarse : 4 graded stone aggregate nominal size) cement concrete etc., complete as required.
27Repairing / Servicing of existing LED Exit sign board at T1 & T4 Terminals etc., as required.
28SH-III: Supply of following electrical spares on as and when required basis.
29Supply of Double drum winch suitable for 25 - 30 m high mast
30Supply of Double drum winch suitable for 100 ft flag mast
31Supply of Stainless steel wire rope 6mm dia.
32Supply of Wire clamps (U type)
33Supply of Lantern Carriage resting arm (Set of 3)
34Supply of Headframe pulley
35Supply of Headframe pulley for flag mast
36Supply of Eye Bolt with Clamps
37Supply of Drive chain with connecting pins
38Supply of Ratchet wheel set (Torque limiter)
39Supply of Gear oil SAE 140 (5 Litre Can) (IOCL/ BPCL/ HPCL/ CASTROL make)
40Supply of 16A, 5pin splash proof Insulated plug socket set
41Supply of LED Aviation Obstruction light, shall have input 240V, 50Hz IP65, suitable for Flag Mast/High mast etc. as required.
42Supply of 5C x 4 sqmm copper conductor, EPR insulated, PC tape, PCP outer sheathed Elastomeric Rubber cable of 1.1KV grade for use in high masts as trailing cable.
43Supply of 3C x 2.5 sqmm copper conductor, EPR insulated, PC tape, PCP outer sheathed Elastomeric Rubber cable of 1.1KV grade for use in high masts as trailing cable.
44Supply of 1.1kW(1.5HP), 415V, 50Hz, 989 RPM (6 pole motor), S1 duty, IP55 with Class F Insulation Energy Efficient, TEFC, Induction motor conforming to IS 12615 for high mast/ Flag mast application with all accessories.
45Supply of 1.5kW(2HP), 415V, 50Hz, 989 RPM (6 pole motor), S1 duty, IP55 with Class F Insulation Energy Efficient, TEFC, Induction motor conforming to IS 12615 for high mast drive application with all accessories.
46Supply of 12Volt, 45watts, 5 metres length of profile shine LED light Strips 6500K Philips make, model No. 57808 product code: 929003591801, 240LEDs per meter or equivalent.
47Supply of input 220Volt/ Output 12Volt Led Light Driver,60W 5A 12V DC of Philip make model No. C060C500V012FNE2AIC2 or its equivalent.
48Supply of input 220Volt/ Output 12Volt Led Light Driver, 24W 2A 12V DC of Philip make model No. C024C200V012FNP3AI or its equivalent.
49Supply of 4 core x 25 sqmm XLPE insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1KV grade conforming to relevant IS 7098 Part 1 with upto date amendments etc. as required.
50Supply of 3.5 core x 35 sqmm XLPE insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1KV grade conforming to relevant IS 7098 Part 1 with upto date amendments etc. as required.
51SH-IV: Signages and associated electrical works on as and when required basis.
52Facility Announcers - Passenger Amenities
53Refer design drawing 1.7dS, 1.7dG
54Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. All exterior signs should be manufactured considering harsh outdoor conditions, weatherproofing techniques and materials shall be used.
55Sign Box 1
56Providing and fixing sign box all 4 sides with laser cut Bent Fabrication in 8mm thick clear acrylic with pantone yellow C Vinyl pasted over acrylic with white diffuser film on inside face. Blockout vinyl for text Pantone Black 6C. Complete box excluding bottom side is lited with internal LED lighting. Acrylic fabrication shall have transparent structural supports for obstruction free lighting. Box to be directly mounted on the sign structure.
57Sign face
58Providing and fixing sign face with 3 mm thick Aluminium sheet fabrication with black colour RAL 9011, Aluminium sheet fixed to sign structure with a provision of niche for telephone as specified in the drawings.
59Sign Structure
60Providing and fixing MS square 50 x 50 x 2 mm fabrication, 50 microns hot dipped galvanised and fixed to the ground. Frame to receive the sign face with 3 mm thick Aluminium sheet fabrication with specific grey colour, Aluminium sheet fixed to sign structure as specified in the drawings. The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together.
61Lighting
62All internal illumination shall be using Power LED Light strips/modules from Osram or equivalent with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification .Cost to include all internal connections and Wiring, terminating and connecting the incoming cable at the site.
63Foundation
64Providing and fixing signboard in position and sturdy on existing floor by suitable size anchor fasteners(Anti Corrosive type) and fixing in position electrical connection wherever applicable and finished as per drawing. The item cost includes cutting and opening the floor finish at location, and making good the location to the match the original finish after fixing and installation of sign.
65Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing.
66Ceiling Hung Directional Sign
67Refer design drawing 2.1aS, 2.1aG
68Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge.
69Sign face
70Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone yellow C or Cyan 311C as per graphics (Wherever Single side content provided then other side also to be provided with 5 mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl shall match colour Pantone Black 6C The sign height shall be equal to the message panel height used i.e. multiple of 255mm and of specified make duly approved by the Engineer-in-Charge.
71Sign Frame
72Providing and fixing sign frame 50mm wide Powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with 3M brand dual lock system in one side and 3M both way tape from the other side. The panel should be made easily openable for maintenance.
73Sign internal Structure
74Providing and fixing Framework of Aluminium 25mmx 25mm x 1.5 hollow square sections. Shall be directly fixed to the sign frame.
75Suspender
76Providing and fixing Stainless steel 32mmx32mmx2mm Hollow sections (assuming typical length of 1 metre) mounted on slabs/beams/walls. All hardware used for fixing of sign shall be Stainless steel. The item cost includes cutting and opening of various types of false at location, and making good the location to the match the original finish after fixing and installation of sign.
77Lighting
78All internal illumination shall be using Power LED Light strips/modules from Osram or equivalent ( Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable at the site. The number of LED strips / modules and electronic controllers shall vary as per number of messages in sign board to the satisfactory illumination of sign boards.
79The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together.
80Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing.
81Message 1 (Single Side)
82Message 1 (Double Side)
83Message 2 (Single Side)
84Message 2 (Double Side)
85Message 3 (Single Side)
86Message 3 (Double Side)
87Message 4 (Single Side)
88Message 4 (Double Side)
89Floor mounted directional sign - Without FIDS
90Refer design drawing 2.1b-1S, 2.1b-1G
91Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge.
92Sign face
93Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone yellow C or Cyan 311C as per graphics (Wherever Single side content provided then other side also to be provided with 5 mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl shall match colour Pantone Black 6C).The sign panel height shall be equal to the message panel height used i.e. multiple of 255mm and of specified make duly approved by the Engineer-in-Charge.
94Sign Frame
95Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system in one side and 3M both way tape from the other side. The panel should be made easily openable for maintenance.
96Sign Structure
97All structural members in SS square post 100 x 100 x 3mm and horizontal cross tie member square sections 50x50x2mm, brush finished. base plate embedded below the floor finish and provided with a floor trim ring. All hardware used for fixing of sign shall be Stainless steel. Post including SS base Plate and Gussets in 6mm thick SS Plate as per drawing with holes to fix it on holding down bolts anchored in concrete slab. The post shall closed with a 3 mm thick SS plate as specified and approved by the Engineer-In-charge. The Post shall be always be a single continuous element without any joints. Cost to include all activities and temporary props used for a perfect vertical in plumb installation, etc. required for fixing the sign in an internal location. The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together.
98Lighting
99All internal illumination shall be using Power LED Light strips/modules from Osram or equivalent ( Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable at the site. The number of LED strips / modules and electronic controllers shall vary as per number of messages in sign board to the satisfactory illumination of sign boards.
100The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together.
101Foundation
102Providing and fixing SS Posts in position and sturdy on existing RCC floor below the granite by using suitable size anchor fasteners(Anti Corrosive type) and finished as per drawing. The item cost includes cutting and opening the floor granite/marble/tile etc finish at location, and making good the location to the match the original finish after fixing and installation of sign.
103Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing.
104Message 3 (Single Side)
105Message 3 (Double Side)
106Message 4 (Single Side)
107Message 4 (Double Side)
108Message 5 (Single Side)
109Message 5 (Double Side)
110Floor mounted directional sign - With Maps
111Refer design drawing 2.1b-2S, 2.1b-2G
112Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge.
113Sign face
114Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone yellow C or Cyan 311C as per graphics (Wherever Single side content provided then other side also to be provided with 5 mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl shall match colour Pantone Black 6C).The sign panel Height shall be equal to the message panel height used. i.e. multiple of 255mm and of specified make duly approved by the Engineer-in-Charge.
115Sign Frame
116Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system in one side and 3M both way tape from the other side. The panel should be made easily openable for maintenance.
117Sign internal Structure
118Providing and fixing Framework of Aluminium 25mmx 25mm x 1.5 mm hollow square sections. Shall be directly fixed to the sign frame.
119Sign Structure
120All structural members in SS square post 100 x 100 x 3 mm and horizontal cross tie member square sections 50x50x 2.5mm brush finished, base plate embedded below the floor finish and provided with a floor trim ring. All hardware used for fixing of sign shall be Stainless steel. Post including SS base Plate and Gussets in 6mm thick SS Plate as per drawing with holes to fix it on holding down bolts anchored in concrete slab. The post shall closed with a 3 mm thick SS plate as specified and approved by the Engineer-In-charge. The Post shall be always be a single continuous element without any joints. Cost to include all activities and temporary props used for a perfect vertical in plumb installation, etc. required for fixing the sign in an internal location.The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together.
121Information Panel
122Providing and fixing 50 mm wide Aluminium extrusion openable secure frames with printed graphic behind 4mm clear Polycarbonate.Secret fixing methods should be used to fix parts together (rear side also to be provided with 4 mm thick Polycarbonate (as specified) having graphics pasted in Plotter cut Blockout vinyl shall match colour Pantone Black 6C.)
123Lighting
124All internal illumination shall be using Power LED Light strips/modules from Osram or equivalent (Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable laid by Airport contractor at the site. The number of LED strips / modules and electronic controllers will vary as per number of messages in sign board and to the satisfaction of the Engineer-in-Charge.
125The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together.
126Foundation
127Providing and fixing SS Posts in position and sturdy on existing RCC floor below the granite by using suitable size anchor fasteners(Anti Corrosive type) and fixing in position electrical connection wherever applicable and finished as per drawing. The item cost includes cutting and opening the floor granite/marble/tile etc. finish at location, and making good the location to the match the original finish after fixing and installation of sign.
128Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing.
129Message 3 (Single side)
130Message 3 (Double Side)
131Message 4 (Single side)
132Message 4 (Double Side)
133Message 5 (Single side)
134Message 5 (Double Side)
135Floor mounted directional sign - Single
136Refer design drawing 2.1b-3S, 2.1b-3G
137Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge.
138Sign face
139Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone yellow C or Cyan 311C as per graphics (Wherever Single side content provided then other side also to be provided with 5 mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl shall match colour Pantone Black 6C).The sign panel Height shall be equal to the message panel height used. i.e. multiple of 255mm and of specified make duly approved by the Engineer-in-Charge.
140Sign Frame
141Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system in one side and 3M both way tape from the other side. The panel should be made easily openable for maintenance.
142Sign internal Structure
143Providing and fixing Framework of Aluminium 25mmx 25mm x 1.5 mm hollow square sections. Shall be directly fixed to the sign frame.
144Sign Structure
145All structural members in SS square post 100 x 100 x 3 mm, brush finished. base plate embedded below the floor finish and provided with a floor trim ring. All hardware used for fixing of sign shall be Stainless steel. Post including SS base Plate and Gussets in 6mm thick SS Plate as per drawing with holes to fix it on holding down bolts anchored in concrete slab. The post shall closed with a 3 mm thick SS plate as specified and approved by the Engineer-In-charge. The Post shall be always be a single continuous element without any joints. Cost to include all activities and temporary props used for a perfect vertical in plumb installation, etc. required for fixing the sign in an internal location.The actual structural design of the sign for its stability shall be ensued. Secret fixing methods should be used to fix parts together.
146Tension Rod
147Providing and fixing tension rod of dia 10mm in brush finished S.S. with the turn buckle system. Tension rod shall be fixed to the sign structure and the sign frame with S.S. gusset plates.
148Lighting
149All internal illumination shall be using Power LED Light strips/modules from Osram or equivalent (Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable at the site. The number of LED strips / modules and electronic controllers shall vary as per number of messages in sign board to the satisfactory illumination of sign boards.
150The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together.
151Foundation
152Providing and fixing SS Post in position and sturdy on existing RCC floor below the granite by using suitable size anchor fasteners(Anti Corrosive type) and finished as per drawing. The item cost includes cutting and opening the floor granite/marble/tile etc. finish at location, and making good the location to the match the original finish after fixing and installation of sign.
153Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing.
154Message 1 (Single Side Content either LHS or RHS of Pole)
155Message 2 (Single Side Content either LHS or RHS of Pole)
156Message 3 (Single Side Content either LHS or RHS of Pole)
157Message 4 (Single Side Content either LHS or RHS of Pole)
158Message 5 (Single Side Content either LHS or RHS of Pole)
159Floor mounted directional sign - Double
160Refer design drawing 2.1b-4S, 2.1b-4G
161Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge.
162Sign face
163Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone yellow C or Cyan 311C as per graphics (Wherever Single side content provided then other side also to be provided with 5 mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl shall match colour Pantone Black 6C).The sign panel Height shall be equal to the message panel height used. i.e. multiple of 255mm and of specified make duly approved by the Engineer-in-Charge.
164Sign Frame
165Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system in one side and 3M both way tape from the other side. The panel should be made easily openable for maintenance.
166Sign internal Structure
167Providing and fixing Framework of Aluminium 25mmx 25mm x 1.5 mm hollow square sections. Shall be directly fixed to the sign frame.
168Sign Structure
169All structural members in SS square post 100 x 100 x 3 mm, brush finished. base plate embedded below the floor finish and provided with a floor trim ring. All hardware used for fixing of sign shall be Stainless steel. Post including SS base Plate and Gussets in 6mm thick SS Plate as per drawing with holes to fix it on holding down bolts anchored in concrete slab. The post shall closed with a 3 mm thick SS plate as specified and approved by the Engineer-In-charge. The Post shall be always be a single continuous element without any joints. Cost to include all activities and temporary props used for a perfect vertical in plumb installation, etc. required for fixing the sign in an internal location.The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together.
170Tension Rod
171Providing and fixing tension rod of dia 10mm in brush finished S.S. with the turn buckle system. Tension rod shall be fixed to the sign structure and the sign frame with S.S. gusset plates.
172Lighting
173All internal illumination shall be using Power LED Light strips/modules from Osram or equivalent (Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable at the site. The number of LED strips / modules and electronic controllers shall vary as per number of messages in sign board to the satisfactory illumination of sign boards.
174The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together.
175Foundation
176Providing and fixing SS Post in position and sturdy on existing RCC floor below the granite by using suitable size anchor fasteners(Anti Corrosive type) and finished as per drawing. The item cost includes cutting and opening the floor granite/marble/tile etc. finish at location, and making good the location to the match the original finish after fixing and installation of sign.
177Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing.
178Message 3 (Single Side content on LHS & RHS of Pole)
179Message 3 (Double Side content on LHS & RHS of Pole)
180Wall mounted Directional Sign
181Refer design drawing 2.1c-S, 2.1c-G
182Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge.
183Sign face
184Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone yellow C or Cyan 311C as per graphics and of specified make duly approved by the Engineer-in-Charge. The sign panel height shall be equal to the message panel height used i.e. multiple of 255mm.
185Sign Frame
186Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system in one side and 3M both way tape from the other side. The panel should be made easily openable for maintenance.
187Sign internal Structure
188Providing and fixing Framework of Aluminium 25mmx 25mm x 1.5mm hollow square sections. Shall be directly fixed to the sign frame.
189Lighting
190All internal illumination shall be using Power LED Light strips/modules from Osram or equivalent (Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable laid by Airport contractor at the site. The number of LED strips / modules and electronic controllers shall vary as per number of messages in sign board to the satisfactory illumination of Sign Board.
191The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together.
192Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing.
193Message 1 (Single Side)
194Message 2 (Single Side)
195Message 3 (Single Side)
196Message 4 (Single Side)
197Message 5 (Single Side)
198Wall Projected Directional Sign
199Refer design drawing 2.1d-S, 2.1d-G
200Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge.
201Sign face
202Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone yellow C or Cyan 311C as per graphics (Wherever Single side content provided then other side also to be provided with 5 mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl shall match colour Pantone Black 6C).The sign panel height shall be equal to the message panel height used i.e. multiple of 255mm and of specified make duly approved by the Engineer-in-Charge.
203Sign Frame
204Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system in one side and 3M both way tape from the other side. The panel should be made easily openable for maintenance.
205Sign internal Structure
206Providing and fixing Framework of Aluminium 25mmx 25mm x1.5mm hollow square sections. Shall be directly fixed to the sign frame.
207Tension Rod
208Providing and fixing tension rod of 10 mm dia in brush finished S.S. with the turn buckle system. Tension rod shall be fixed to the wall structure and the sign frame with S.S. gusset plates.
209Lighting
210All internal illumination shall be using Power LED Light strips/modules from Osram or equivalent (Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable at the site. The number of LED strips / modules and electronic controllers shall vary as per number of messages in sign board to the satisfactory illumination of Sign boards.
211The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together.
212Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing.
213Message 1 (Double Side Either LHS or RHS of Column/Wall/Steel Structure)
214Message 2 (Double Side Either LHS or RHS of Column/Wall/Steel Structure)
215Message 3 (Double Side Either LHS or RHS of Column/Wall/Steel Structure)
216Wall Mounted Facility Announcer
217Refer design drawing 2.2a-S, 2.2a-G
218Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge.
219Sign face
220Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone yellow C or Cyan 311C as per graphics (Wherever Single side content provided then other side shall be provided with ACP) and of specified make duly approved by the Engineer-in-Charge.
221Sign Frame
222Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system in one side and 3M both way tape from the other side. The panel should be made easily openable for maintenance.
223Lighting
224All internal illumination shall be using Power LED Lights from Osram or equivalent (Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable at the site.
225The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together.
226Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing.
227Wall Projected Facility Announcer
228Refer design drawing 2.2b-S, 2.2b-G
229Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge.
230Sign face
231Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone yellow C or Cyan 311C as per graphics and of specified make duly approved by the Engineer-in-Charge. (Double Side)
232Sign Frame
233Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system in one side and 3M both way tape from the other side. The panel should be made easily openable for maintenance.
234Lighting
235All internal illumination shall be using Power LED Lights from Osram or equivalent (Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable at the site.
236The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together.
237Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing.
238Boarding Gates - Totem Without Information panel/ FIDS
239Refer design drawing 2.2g-1-S, 2.2g-1-G
240Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. (Signboard should have provision of opening for maintenance)
241Sign Box
242Providing and fixing sign box with laser cut Bent Fabrication in 5mm thick clear acrylic with pantone yellowC Vinyl pasted on it. Complete box excluding bottom side is lited with internal LED lighting. Acrylic fabrication shall have transparent structural supports for obstruction free lighting. Box to be directly mounted on the sign structure. Text in opaque black vinyl to match RAL 9011
243Sign Face
244Providing and fixing sign face panels 3 mm thick Aluminium sheet fabrication, Aluminium sheet fixed to sign structure with black colour RAL 9011 with a provision of through and through laser cutting for information panel and text with pantone yellowC Vinyl. Backlit Text with 5mm thick milky white acrylic flushed with the sign face. Bottom structure to be finished in 3 mm thick Aluminium sheet fabrication with grey colour RAL 9006 and directly fixed to the sign structure.
245Sign Structure
246Providing and fixing MS square post 50x50x2.5mm fabrication, 50 microns hot dipped galvanised and fixed to the ground. Frame to receive the sign faces.The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together.
247Crash Guard
248Providing and fixing Protection for sign from trollies, wheeled baggage in 18 SWG stainless steel pipe 2mm dia brush finished fixed with 6mm thick SS plate bracket.
249Lighting
250All internal illumination shall be using Power LED Lights from Osram or equivalent ( Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting with the incoming cable at the site.
251Foundation
252Providing and fixing of MS Posts of Signboard in position and sturdy on existing floor by suitable size anchor fasteners(Anti Corrosive type) and finished as per drawing. The item cost includes cutting and opening the floor finish at location, and making good the location to the match the original finish after fixing and installation of sign
253Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing.>>
254Boarding Gates - Wall Projected
255Refer design drawing 2.2g-2-S, 2.2g-2-G
256Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge.
257Sign face
258Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective over laminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone yellow C or Cyan 311C as per graphics and of specified make duly approved by the Engineer-in-Charge.
259Sign Frame
260Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system in one side and 3M both way tape from the other side. The panel should be made easily openable for maintenance.
261Lighting
262All internal illumination shall be using Power LED Lights from Osram or equivalent (Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable at the site.
263The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together.
264Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing.
265Boarding Gates - Wall Mounted (Modified) without Information panel/ FIDS
266Refer design drawing 2.2g3-S, 2.2g3-G (modified)
267Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. (Wherever Single side content provided then other side shall be provided with ACP)
268Sign face
269Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone yellow C or Cyan 311C as per graphics with a provision of through and through cut out for information panel and of specified make duly approved by the Engineer-in-Charge.
270Sign Frame
271Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system. The panel should be made easily openable for maintenance.
272Sign internal Structure
273Providing and fixing Framework of Aluminium 25mmx 25mm x1.5 mm hollow square sections. Shall be directly fixed to the sign frame.
274Lighting
275All internal illumination shall be using Power LED Lights from Osram or equivalent (Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable at the site.
276The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together.
277Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing.
278Airport zonal route Map - Interiors
279Refer design drawing 2.3a-S, 2.3a-G
280Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. (Wherever Single side content provided then other side also to be provided with 5 mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl shall match colour Pantone Black 6C)
281Sign Face
282Providing and fixing sign face panel in 5mm thick white translucent 040 acrylic. Graphics - Plotter cut blockout vinyl pantone black C, translucent printed vinyl for text / Map and pasted over white translucent acrylic.
283Sign Frame
284Providing and fixing sign frame of 50mm wide powder coated, colour RAL 9006 aluminium extrusion with inbuilt frame to receive the sign face. The panel should be made easily openable from back for maintenance.
285Sign Structure
286SS square post 70x70X3 mm and horizontal square sections 50 x 50 X 2 mm mm Post including SS base Plate in 6mm thick as per drawing with holes to fix it on holding down bolts anchored in concrete footing. The post shall closed with a 3 mm thick SS plate The post shall closed with a 3 mm thick MS plate and parts kept unpainted to weld the sign structure as per the drawing to ensure a rigid connection at site. The entire post assembly shall be hot dipped galvanised and P.U. Painted to match RAL 9006 as specified and approved by the Engineer-In-charge. The Post shall be always be a single continuous element without any joints. Cost to include all activities and temporary props used for a perfect vertical in plumb installation, shim Plates for adjustment of levels and filling the gap with concrete slurry etc. required for fixing the sign in an external location.The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together. 225x225mm size, 5 mm thick cover plate mounted in case the flooring is present.
287Lighting
288All internal illumination shall be using Power LED Lights from Osram or equivalent ( Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable at the site.
289Foundation
290Providing and fixing SS Posts in position and sturdy on existing RCC floor below the granite by using suitable size anchor fasteners(Anti Corrosive type) and finished as per drawing. The item cost includes cutting and opening the floor granite/marble/tile etc. finish at location, and making good the location to the match the original finish after fixing and installation of sign
291Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing.
292Lift Directory
293Refer design drawing 2.3b-S, 2.3b-G
294Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge.(Wherever Single side content provided then other side shall be provided with 3 mm thick ACP)
295Sign face
296Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone yellow C or Cyan 311C as per graphics and of specified make duly approved by the Engineer-in-Charge.
297Sign Frame
298Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system. The panel should be made easily openable for maintenance.
299Lighting
300All internal illumination shall be using Power LED Lights from Osram or equivalent ( Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting with the incoming cable at the site.
301The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together.
302Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing.
303Washroom / Drinking Water / Baby care
304Refer design drawing 2.4a-S, 2.4a-G
305Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge.(Wherever Single side content provided then other side shall be provided with 3 mm thick ACP)
306Sign face
307Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone Cyan 311C as per graphics and of specified make duly approved by the Engineer-in-Charge.
308Sign Frame
309Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system in one side and 3M both way tape from the other side. The panel should be made easily openable for maintenance.
310Lighting
311All internal illumination shall be using Power LED Lights from Osram or equivalent (Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting with the incoming cable at the site.
312The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together.
313Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing.
314Wall Projected (Double Side - Sign face in acrylic)
315Wall mounted (Single side content - Sign Face: acrylic, and Back: 3mm ACP)
316Lift No. Sign
317Refer design drawing 2.4c-S, 2.4c-G
318Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge.(All the wall mount signs shall be provided with 3 mm thick ACP at the back)
319Sign face
320Sign face shall be made in 5mm thick 040 white acrylic (as specified) having graphics pasted in Plotter cut Blockout vinyl. Entire panel covered with a protective overlaminate. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The Plotter cut blockout vinyl shall match the specified colour (colour Pantone Black 6C) and vinyl for text Pantone Cyan 311C as per graphics and of specified make duly approved by the Engineer-in-Charge.
321Sign Frame
322Providing and fixing sign frame 50mm wide powder coated, colour RAL 9006 special aluminium extrusion with inbuilt frame to receive the sign face. The sign face shall be fixed to sign frame with the 3M brand dual lock system. The panel should be made easily openable for maintenance.
323Lighting
324All internal illumination shall be using Power LED Lights from Osram or equivalent (Edge lighting - 6500K, 24 v, with optimal homogeneous backlighting & light Throw of minimum 4 ft) with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting with the incoming cable at the site.
325The actual structural design of the sign for its stability shall be ensured. Secret fixing methods should be used to fix parts together.
326Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing.
327Wall Projected (Double Side - Sign face in acrylic)
328Wall mounted (Single side content - Sign Face: acrylic, and Back: 3mm ACP)
329Emergency Direction Signs - Illuminated
330Refer design drawing 2.6a-G
331Providing and fixing illuminated emergency signs (having min.1.5 hrs backup time) including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge.
332Sign face
333Sign face shall be made in 5mm thick Laminated acrylic (as specified) having graphics pasted on the inside with translucent white vinyl pasted over plotter cut Translucent vinyl. The Plotter cut translucent vinyl to match the specified colour and of specified make duly approved by the Engineer-in-Charge. (As per design drawings, Emergency signs are in various sizes, single sided for wall/face mounted and double sided for Ceiling hung/wall projected/floor mounted)
334Suspender for ceiling hung
335Providing and fixing Stainless steel 32 x 32 mm x 2 mm Hollow sections (assuming typical length of 1 metre) mounted on slabs/beams/walls. All hardware used for fixing of sign shall be Stainless steel. The item cost includes cutting and opening of various types of false at location, and making good the location to the match the original finish after fixing and installation of sign.
336Sign Box
337The sign box 80 mm deep shall be made out of 1.6 mm thick CRCA MS sheet fabricated and provided with same material support channel and ties welded to sign channel. All fabrication shall be done using CNC machines. Sign box shall be provided with openings with Mesh from inside for ventilation. Complete sign box including channel supports are to be powder coated to match RAL9016. Sign box flange receiving the sign face shall be provided with slots to receive the rivets to fix the sign frame.
338Lighting
339All internal illumination shall be using Power LED Lights from Osram or equivalent with electronic controllers, having even spread and overlaps to avoid banding and dark spots and adhering to the LUX levels mentioned in the performance specification. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable laid by Airport contractor at the site.
340Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing.
341Emergency Exit
342Providing and Fixing of computerised 3M vinyl cut text of approved matter in three language with directional sign etc., in double colour on existing 5mm thick Polycarbonate sheet of different sizes on existing signages including dismantling of existing polycarbonate sheet board from the existing signage board and remove the existing signage vinyl sticker over the polycarbonate sheet including cleaning of the complete polycarbonate surface without causing any damage and scratch over the surface and re-fixing the polycarbonate sheet on the existing sign board etc., as per direction of Engineer-in-Charge complete as required.Note: In case of any breakage of Polycarbonate sheets during dismantling, shifting, handling & re-fixing etc., the complete sheet to be replaced by contractor at free of cost.
343Providing and fixing of new Airline logo sticker at city side departure level airline listing announcer board as per direction of Engg-in-charge.
344Providing and fixing of computerized poly vinyl sticker with blue background and white letters have self adhesive type complete as required and as per direction of Engg-in-charge.
345Supply, assembly and laying of under floor trunking made out of 1.6mm(min) thick GI sheet complete with jointing sleeve, horizontal bends, vertical bends, level adjustment components and closer, vertical elbow, covers, access outlet. etc. complete with all other accessories under floor installation, making good the same, placing in position and cleaning from inside complete etc. as required.
346a) 150 mm wide x 38 mm deep raceway (1 compartment)
347b) 50 mm wide x 38 mm deep raceway (1 compartment)
348Providing and fixing 300 x 300 x 50-70 mm deep GI (hot dip galvanized) cross over box made out of 1.6 mm thick sheet steel cross over box in under floor installation in complete as required as per specification.
349Providing and fixing 225 x 225 x 50-70 mm deep GI (hot dip galvanized) cross over box made out of 1.6 mm thick sheet steel junction box in under floor installation in complete as required as per specification.
350Providing and fixing 150 x 150 x 50-70 mm deep GI (hot dip galvanized) cross over box made out of 1.6 mm thick sheet steel junction box under floor installation in complete as required as per specification.
351Supply and fixing of pop up type metal flush mounting box (floor mounted) on floor including Switch & sockets, connection & accessories etc. as required.
352a) 3 Module ( 6 amps ) (Similar to Legrand Cat No. 0540 10or Equivalent)
353b) 6 Module ( 6/16 amps) (Similar to Legrand Cat No. 0540 12 or Equivalent)
354Supply and fixing of pop up type metal flush mounting box (Furniture Mounted)including Switch & sockets, connection & accessories etc. as required.
355a) 4 Module ( 6/16 amps) (Similar to Legrand Cat No. 6540 14 or Equivalent) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58532611
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 2.85 Crore
LAST DATE 07-12-2026
Authority
Authority Name Airports Authority Of India
Work Description Tender for Annual Rate Contract For Providing Way Finding Signages And Associated Electrical Works Including Providing Decorative Lighting For Terminal Building & Carpark Area Of T1, T2 & T4 In View Of Festival / Occasions And Supply Of Electrical Spares And Other Miscellaneous Works At Chennai International Airport.
Basic Detail
Tender No AAI_CHE_AMED-II_2026_5
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 14 Nov 2026
Submission Date 07 Dec 2026
Open Date 08 Dec 2026
Finance
Tender Value 2.85 Crore
Tender Fee 1180
EMD 5.70 Lakhs
Exemption Not Available
Document List
BOQ_347019.xls
e5948132-a2d5-41f3-81b3-8ac517bb714a.html
TenderDocument.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Dec 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_347019.xls

html

e5948132-a2d5-41f3-81b3-8ac517bb714a.html

pdf

TenderDocument.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender