Housing Urban and Rular Development Government Departments Closing in 2 days TDR #58531038

Tender For Proposed Construction Of Kendriya Vidyalaya At Hazipur Distt.- Vaishali, State-Bihar. (Notice No. -11/Uppcl/Gm-5/E-Tender/2026-27 Dated: 30-10-2026)

Issued by Government Departments · Vaishali, Bihar
Tender Value
27.35 Crore
Estimated cost
Bid Submission
21 Nov 2026
2 days left
EMD
54.71 Lakhs
Bank guarantee accepted
Document Fee
17700
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Vaishali → Bihar
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Proposed Construction Of Kendriya Vidyalaya At Hazipur Distt.- Vaishali, State-Bihar. (Notice No. -11/Uppcl/Gm-5/E-Tender/2026-27 Dated: 30-10-2026)

BOQ

Name of Work:- PROPOSED CONSTRUCTION OF KENDRIYA VIDYALAYA AT HAZIPUR DISTT.- VAISHALI, STATE-BIHAR. (Notice No. -11/UPPCL/GM-5/E-TENDER/2026-27 Dated: 30-10-2026)
Sl. No. Item Description
1PROPOSED CONSTRUCTION OF KENDRIYA VIDYALAYA AT HAZIPUR DISTT.- VAISHALI, STATE-BIHAR.
2UP TO PLINTH LEVEL
3Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
4All kinds of soil
5Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated orstacked materials.
6All kinds of soil
7Excavating, supplying, stacking and filling of local earth (including royalty) by mechanicaltransport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
8Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
9Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion)
10Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:
11With Chlorpyriphos/Lindane E.C. 20% with 1%concentration
12Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
131:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
14Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
15Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
16RCC WORK UPTO PLINTH
17providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland Slag cement, admixtures in recommended proportions as per iS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
18All works upto plinth level
19concrete of m30 grade with minimum cement content of 350 kg /cum
20COLUMN
21PLINTH BEAM
22PLINTH BAND
23Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
24Thermo-Mechanically Treated bars of grade Fe-500D or more.
25Centering and shuttering including strutting, propping etc. and removal of form for
26COLUMN
27PLINTH BEAM
28PLINTH BAND
29Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
30Cement mortar 1:6 (1 cement : 6 coarse sand)
3115 mm cement plaster of mix :
321:4 (1 cement: 4coarse sand)
33Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
3425 mm thick with 20 mm nominal size stone aggregate
35SUPER STRUCTURE(G+3)
36Providingand laying inposition readymixedorsitebatcheddesignmixcement concrete for reinforcedcementconcretework; using coarse aggregateand fineaggregatederived fromnatural sources, Portland Pozzolana /Ordinary Portland/ PortlandSlag cement, admixtures in recommendedproportionsasper IS:9103toaccelerate/retards ettingof concrete, to improvedurabilityand workability withoutimpairingstrength; includingpumpingofconcretetositeof laying,curing, carriageforall leads;butexcludingthecostofcentering,shuttering, finishingand reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note:Extracementupto10%of theminimumspecifiedcementcontentindesignmixshallbepayableseparately.In case the cement content indesignmix ismore than110%of the specifiedminimumcement content, thecontractor shall have discretion to either re-design the mix or bear the cost of extra cement All works above plinth level upto floor V level
37Concrete of M30 grade with minimum cement content of 350 kg /cum
38COLUMN
39GROUND FLOOR
40FIRST FLOOR
41SECOND FLOOR
42THIRD FLOOR
43MUMTY
44LINTEL BAND
45GROUND FLOOR
46FIRST FLOOR
47SECOND FLOOR
48THIRD FLOOR
49SILL BAND
50GROUND FLOOR
51FIRST FLOOR
52SECOND FLOOR
53THIRD FLOOR
54GROUND FLOOR
55FIRST FLOOR
56SECOND FLOOR
57THIRD FLOOR
58MUMTY
59GROUND FLOOR
60FIRST FLOOR
61SECOND FLOOR
62THIRD FLOOR
63MUMTY
64WARDROBE
65Thermo-Mechanically Treated bars of grade Fe-500D or more.
66Centering and shuttering including strutting, propping etc. and removal of form for
67Column
68LINTEL BAND
69SILL BAND
70Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
71Providing and laying Autoclaved Aerated concrete blosks masonry 100 mm/ 125 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work
72Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor five level in :Cement mortar 1:6 (1 cement : 6 coarse sand)
73Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
7435 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
7525 mm thick (For Cupboard)
76Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. Thelaminate shall be moulded with fire resistant grade unsaturated polyester resin and choppedmat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block inall the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall beprovided at the bottom to steady the frame
77Providing and fixing to existing door frames.
7830 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings,cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames
79Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete :
8020 mm dia
81Providing and fixing S.S.sliding door bolts, ISI marked nuts and screws etc. complete
82300x16 mm
83Providing and fixing S.S. tower bolts, ISI marked, withnecessary screws etc. complete :
84300x10 mm
85Providing and fixing S.S.Handle with necessaryscrews etc. complete
86125 mm
87Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour andshade, with necessary screws etc. complete.
88Single rubber stopper
89Providing and fixing aluminium die cast body tubular type universal hydraulic door closer(having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and doorwidth upto 700 mm), with necessary accessories and screws etc. complete.
90Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
91Using M.S. angels 40x40x6 mm for diagonal braces
92Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard withrectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded andgrinded finish, with profiles of required size, including fixing of necessary butt hinges andscrews and applying a priming coat of approved steel primer.
93Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C.1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
94Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
9535x35x5 (For wardrobe)
96Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete..Fixed to steel windows by welding
97Providing and fixing anodised aluminium grill (anodised transparent or dyed to requiredshade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper openingsize for fixing and operation of handles and fixing approved anodised aluminium standardsection around the opening, all complete as per requirement and direction of Engineer-incharge.(Only weight of grill to be measured for payment).
98Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of leadfree uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extrude dprofiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and designduly reinforced with galvanized mild steel section made of required shape & size as perCPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (whereever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fastenersof minimum 8 mm dia with countersunk head,
99comprising of matching polyamide PA6 gradesleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plasticcaps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required)shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, includingdrilling of holes for fixing hardware and drainage of water etc. After fixing frame the gapbetween frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conformingto CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcementand cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.
100Three track three panels sliding window with two glazed & one wire mesh panels withAluminium channel for roller track, wool pile, nylon rollers with SS 304 body.
101Using R4 series with frame (115mm & above) x (45mm & above) & both glazed and fly screen sash (44mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height above 1.8m)
102Providing and fixing glazing in aluminium door, window, ventilator shutters and partitionsetc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings andthe directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basicitem):
103With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
104Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestorywindows, all complete with :
1054.0 mm thick glass panes
106Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mmand braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers,handles, including applying a priming coat of approved steel primer.
107Supply and fixing of anodized Aluminum door having 2mm thick Aluminum section excluding coating & an average coating of 20 micron fully glazed made of Aluminum door tube size 83.5x44.65mm as Vertical member and 1140x44.45mm size tube in bottom & horizontal members Door chaukhat should be of Aluminum tubular vertical with two openable shutters.The rate will include cost of material fixture 5mm glass Partialy glazed handles,locks,screw necessary beeding & excluding cost of floor spring if required for proper completion of work as per direction of Engineer
10815 mm cement plaster of mix :
1091 : 6 (1 cement : 6 coarse sand)
110Outer side
111Extra for plastering exterior walls of height more than 10 m fromground level for every additional height of 3 m or part thereof.
11212 mm cement plaster of mix :
1131 : 6 (1 cement : 6 coarse sand)
114Inner side
115Extra for plastering exterior walls of height more than 10 m fromground level for every additional height of 3 m or part thereof.
116Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high glossfinish etc. complete at all levels.
117Granite stone slab of colour black, Cherry/Ruby red
118Area of slab over 0.50 sqm
119Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete.
120Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with greycement slurry mixed with pigment to match the shade of the slab, including rubbing andpolishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
12125 mm thick
122Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
123Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by themanufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
124Double charge vitrified tile polished finish of size
125Size of Tile 600x600 mm
126Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by themanufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
127Glazed vitrified floor tiles polished finish of size
128Size of Tile 600x600 mm
129Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.
130In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand)
131Acid and alkali resistant tile
132Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
133Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand)and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
134Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles ofSize 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistanceof 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on inter-locking metal powder coatedT-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile, rotary stiched double webbed white with 6 mm reveal profile (white/black),comprising of main-T runners of size 15x42 mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary
135With 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tiles
136Providing and fixing mineral fibre false ceiling tiles at all heights of size595X595mm of approved texture, design and pattern. The tiles shouldhave Humidity Resistance (RH) of 99%, Light Reflectance ? 85%,Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance asper (BS 476 pt - 6 &7)in true horizontal level suspended on interlockingT-Grid of hot dipped all round galvanized iron section of 0.33 mmthick(galvanized @120 gsm) comprising of main T runners of 15x32 mm oflength 3000 mm, cross T of size 15x32mm of length 1200 mm andsecondary intermediate cross T of size 15x32 mm of length 600 mmto form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item
137(galvanised@80gsm) 50 mm long 8mmouter diameter M-6 dash fasteners, 6 mm diameter fully threadedhanger rod up to 1000 mm length and L-shape level adjuster of size85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’.The system should rest on periphery walls /partitions with the help ofGI perimeter wall angle of size24x24X3000 mm made of 0.40 mmthick sheet, to be fixed to the wall with help of plastic rawl plug at 450mm centre to centre & 40 mm long dry wall S.S. screws. The exposedbottom portion of all T-sections used in false ceiling support systemshall be pre-painted with polyester baked paint, for all heights. Thework shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
138With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6
139Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to
140G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
14112.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
142Finishing walls with Acrylic Smooth exterior paint of required shade :
143New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
144Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
145Two coats
146Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
147Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
148Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
149Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofingcompound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm heightincluding rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm ofcement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-incharge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand)admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks forcuring and for final test.“All above operations to be done in order and as directed and specified by the
150(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. * All above operations to be done in order and as directed and specified by the Engineer-In-charge:
151With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
152Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofingcement compound consisting of applying (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of alljoints, corners, junctions of pipes and masonry with polymer mixed slurry.
153Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.
154Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
155In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
156Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Ordinary cement without any pigment.
157Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
15840 mm thick with 20 mm nominal size stone aggregate
159Providing and fixing sheet covering over expansion joints with iron screws as per design.
160Aluminium fluted strips 3.15 mm thick.
161200 mm wide
162FAÇADE
163Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
164Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthenedmonolithic float glass of approved colour and shade with reflective soft coating on surface #2 of approved colour and shade so as to match the colour and shade of the IGUs in the visionpanels etc. ,all complete for the required performances as specified, as per the Architecturaldrawings, as per the approved shop drawings, as specified, and as directed by theEngineerinCharge.For payment, only the actual area of glass on face # 1 of the glass panels (but excluding thearea of grooves and weather silicone sealant) provided and fixed in position, shall be measuredin sqm. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included incost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective softcoating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Lightreflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28)and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided bytechnical sanctioning authority as per the site requirement
165Providing and fixing double scaffolding system (cup lock type) on the exterior side, up toseven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & verticaltubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps andM.S. staircase system in the scaffolding for working platform etc. and maintaining it in aserviceable condition for the required duration as approved and removing it there after .Thescaffolding system shall be stiffened with bracings, runners, connection with the building etcwherever required for inspection of work at required locations with essential safety featuresfor the workmen etc. complete as per directions and approval of Engineer-in-charge .Theelevational area of the scaffolding shall be measured for payment purpose .The payment willbe made once irrespective of duration of scaffolding.
166SANITARY INSTALLATIONS & FITTINGS
167Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
168White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
169Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
170W.C. pan with ISI marked black solid plastic seat and lid
171Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, sizeand pattern including integrated white vitreous china cistern of capacity10 litre with dual flushing system, including all fittings and fixtures withseat cover, cistern fittings, nuts, bolts and gasket etc including makingconnection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.
172Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
173Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls andfloors wherever required :
174One urinal basin with 5 litre white P.V.C. automatic flushing cistern
175Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inletfrom back side, including fixing to wall with suitable brackets all as permanufacturers specification and direction of Engineer-in-charge.
176Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
177a)White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
178Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
179Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :
180Size 600x450x200 mm
181Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
182Semi rigid pipe
18332 mm dia
184Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
185Providing and fixing PTMT Bottle Trap for Wash basin and sink
186Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms
187Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
188Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
189600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
190C.P. BRASS FITTINGS
191Providing and fixing unplasticised PVC connection pipe with brass unions
19245 cm length
19315 mm nominal bore
194Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
19515 mm nominal bore
196Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
19715 mm nominal bore
198INTERNAL SOIL /WASTE PIPE LINE
199Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
200110mm
201Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.
202110 mm diameter
203Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
204Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
205Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories forunplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
206Bend 87.5°
207110 mm bend
208Shoe (Plain)
209150 mm Shoe
210Providing and fixing of UPVC SWR pipe type -B confirming to IS -13592 including jointing the pipe with rubbing ring ,lubricant and UPVC SWR cupler confirming to IS -14735 ,ALSO Including excavation of trenches cutting of walls and holes and repairing the walls ,floors and refiling the trenches as before but excluding supply and cost of other fitting such as elbow bead ,tee and Y -tee including supply of all materials labour and t&p .Required for proper completion of the work .
211a) 150mm dia P.V.C. pipe
212a) 110mm dia P.V.C. pipe
213b) 75mm dia P.V.C. pipe
214Providing and fixing of UPVC SWR door bend confirming to IS-14735.
215110MM
216150MM
217Providing and fixing of UPVC Nahani trap size 100/75mm ,100/90 mm confirming to IS -14735 self cleaning design fixed in pcc 1:2:4 and supply and fixing of 125mm dia heavt duty cp brass jali.
218Providing and fixing of UPVC SWR cowl confirming to IS-14735.
219110MM
220Providing and fixing of UPVC Plain TEE confirming to IS-14735.
22175X75X75MM
222110X110X110MM
223150X150X150MM
224Providing and fixing of UPVC SWR door y confirming to IS-14735.
225110MM
226INTERNAL WATER SUPPLY WORKS
227Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.
228Concealed work including cutting chases and making good the walls etc.
22915mm dia nominal outer dia pipes
23020mm dia nominal outer dia pipes
231Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.
232Internal work-Exposed on wall
23325mm dia nominal bore
23432mm dia nominal bore
23550mm dia nominal bore
236Providing and fixing gun metal gate valve with wheel of approved quality.
23725mm dia nominal bore
23832mm dia nominal bore
23950mm dia nominal bore
240Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license].
241Capcity in Per Liters (RCC TANK IN MUMTY)
242Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete
24325 mm nominal bore
244Providing and fixing RO WATER COOLER Etc complete.
245Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
246Group C
247Wiring for twin control light point with 1.5 sq.mmFRLS/HFFR PVC insulated copper conductor singlecore cable in surface / recessed medium class PVCconduit, 2way modular switch, modular plate, suitableGI box and earthing the point with 1.5 sq.mmFRLS/HFFR PVC insulated copper conductor singlecore cable etc. as required.
248Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
2492 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2502 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2512 X 4 sq. mm + 1 X 4 sq. mm earth wire
2524 X 6 sq. mm + 2 X 6 sq. mm earth wire
2534 X 10 sq. mm + 2 X 6 sq. mm earth wire
2544 X 16 sq. mm + 2 X 16 sq. mm earth wire
255Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
256Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
257Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
258Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 20 amps modular socket outlet and 20 amps modular switch, connection etc. as required.
259Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
260Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
261Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
262Upto 450 mm sweep
263Supplying and drawing 20 Pair 0.5 mm dia FRLS PVCinsulated annealed copper conductor, unarmoredtelephone cable in the existing surface/ recessedsteel/ PVC Conduit etc. complete as required.
2641 Pair
265Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shieldedwith fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVCconduit as required.
266Supplying and fixing of following sizes of medium class PVC conduit along with accessories insurface/recess including cutting the wall and makinggood the same in case of recessed conduit asrequired.
26720 mm
268Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitablesize of phenolic laminated sheet cover in front including painting etc. as required.
269150 mm X 75 mm X 60 mm deep
270Supplying and fixing following piano type switch/socket on the existing switch box/ cover includingconnections etc. as required.
271Telephone socket outlet
272TV antenna socket outlet
273Bell push
274Supplying and fixing following modular switch/ socketon the existing modular plate & switch box includingconnections but excluding modular plate etc. asrequired.
275Telephone socket outlet
276TV antenna socket outlet
277Bell push
278Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modularswitches in recess etc. as required.
2794 Module (125mmX75mm)
280Supplying, Installation, Testing and commissioning ofindoor Wireless Controller having features andspecifications etc. as mentioned here under- TheSupplying, Installation, Testing & Commissioning ofType 1 IP Phone having 2 VoIP account, 120 x40 DOTmatrix screen with backlight, Full HD duplex speakerphone, IPV6, Gigabit Etherent, PoE etc. complete asrequired.
281Supplying, Installation, Testing & Commissioning ofAnalog phones having standard feautres like 16 digitLCD display, 2 way speaker, caller ID and numberstorage facility etc. complete as required.
282MCCB, MCB & DB'S
283Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
2844 way (4 + 12), Double door
2858 way (4 + 24), Double door
286Supplying and fixing following way, single pole andneutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthingetc. as required. (But without MCB/RCCB/Isolator)
28712 way , Double door
2888 way , Double door
289Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
290Single pole
291Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. asrequired.
292Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. asrequired
293100 A
294Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
29540 amps
29663 amps
297Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
298Hot Dipped Galvanized Iron Cable Tray
299Supplying and installing following size of perforatedHot Dipped Galvanised Iron cable tray (Galvanisationthickness not less than 50 microns) with perforationnot more than 17.5%, in convenient sections, joined
300with connectors, suspended from the ceiling with twonumbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required.
301300 mm width X 50 mm depth X 1.6 mm thickness
302225 mm width X 50 mm depth X 1.6 mm thickness
303150 mm width X 50 mm depth X 1.6 mm thickness
304100 mm width X 50 mm depth X 1.6 mm thickness
305Supplying and installing following size of perforatedHot Dipped Galvanised Iron cable tray \\"bends\\"(galvanisation not less than 50 microns) withperforation not more than 17.5%, in convenientsections, joined with connectors, suspended from theceiling with two numbers GI Suspenders i/c base ofsuitable size GI angle, GI bolts & nuts, fastner etc asrequired.
306300 mm width X 50 mm depth X 1.6 mm thickness
307225 mm width X 50 mm depth X 1.6 mm thickness
308150 mm width X 50 mm depth X 1.6 mm thickness
309100 mm width X 50 mm depth X 1.6 mm thickness
310Supplying and installing following size of perforatedHot Dipped Galvanised Iron cable tray \\"Tee\\"(galvanisation not less than 50 microns) withperforation not more than 17.5%, in convenientsections, joined with connectors, suspended from theceiling with two numbers GI Suspenders i/c base ofsuitable size GI angle, GI bolts & nuts, fastner etc asrequired.
311300 mm width X 50 mm depth X 1.6 mm thickness
312225 mm width X 50 mm depth X 1.6 mm thickness
313150 mm width X 50 mm depth X 1.6 mm thickness
314100 mm width X 50 mm depth X 1.6 mm thickness
315Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc.with charcoal/ coke and salt as required.
316Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
317Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
318Providing and fixing of lightning conductor finial, madeof 25 mm dia 300 mm long, G.I. tube, having singleprong at top, with 85 mm dia 6 mm thick G.I. baseplate including holes etc. complete as required.
319Fixing of lightning conductor finial (single prong) withbase plate including holes etc. complete as required
320Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit,safety rope, copper winding, Power Factor not less than 0.9, Service Value(CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (toleranceas per IS : 374-2019), THD less than 10%, remote or electronic regulator unit forspeed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc.complete as required.
321Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box bymeans of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
322Supply & Erection of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc)in each phase withtouch type selector switches for different readings,instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.
323600A, 50kA 4 Pole MCCB, Ics=100% Icu RatingDigital Voltmeter 0-500V with selector switchAmmeter (0-800 A) with selector swtich & CTs etc.LED type RYB phase indicating lamps, ON, OFF,trip indicating lampsSet of Copper Bus Bar 1000AmpsOutgoings(Note : All outgoing feeders for pumps should havedigital Ammeter with selector switches, and LEDtype ON, OFF, trip indicating lamps)
324200Amp MCCB-1, 400AMP MCCB-1 Nos ,100 Amp MCCB -1 No.,63 AMP MCB-1 ,32 AMP MCB -5NO ;20AMP MCB-1 NO & 16 Amp MCCB -1 NO.
325Installation Electrical room
326Supply, Installation, testing and commissioning ofHYBRID APFC Panel, 3 phase 4 wire, 415 V, 50 HzAC System for Ambient temperature -5°C to +40°Cof following capacity with passive solution of 60%capacity and active solution of 40% capacity,3Phase 4wire Hybrid Power Factor Correction Solution (witharrangment for neutral current balance) to achieve>0.99 lag and TDDI/THDV values within IEEErecommended limits.APFC should be designed as perIS 16636 Or IEC 61921. The active section andpassive section shall work in sync to give optimizedoutput. The degree of protection of passive sectionshould be IP 42, and of active section should beminimum IP 21.The switching device for APFCpassive section should be through capacitor dutycontactor and for the active compensation systemshall be IGBT based with 3 level topology having 12IGBT in inverter circuit. The active compensationsystem should filter harmonics from 2nd to 50thindividual harmonic order and shall be selectable forthe entire range. The active compensation systemshould have feature to improve PF correction andharmonic filtration having response time < 100 Microsecond. The hybrid panel shall be indoor type floormounted free standing totally enclosed, extensible,fabricated in compartmentalised designed made ofCRCA sheet steel of 2.0mm thick for framework &
327covers, 3 mm thick for gland plate i/c cleaning &finishing complete with 9 tank process for powdercoated of approved shade ( RAL 7032-Siemens grayor as approved by Engineer-in-Charge), having frontsection (switch gear and control accessories) and rearsection (capacitor and reactor), front and rear access,having suitable current carrying capacity, extensibleTPN Aluminium alloy bus bar of high conductivity,DMC/SMC bus bar supports,bottom base channel ofMS Section, fabrication shall be done in transportablesection, entire panel shall have common copper earthbar of minimum size of 25mm x 5mm with 2 nos.earth studs, the earth terminals provided on the bodyof capacitor bank shall also be bonded to the maincapacitor panel earth bus with 2 nos. 8 SWG or 6SWG GI earth wires/ equivalent size of copperconductor cable, forced ventilation for maintainingtemperature rise not more than 5°C from ambient,interconnections, connections with 14% detunedreactor and heavy duty 525 V ISI marked ImpregnatedMPP(Metalized Polypropylene) Capacitor (IS 13340Part -1 & 2) APFC Panel shall be in compliance withIS :16636 & CPWD Specifications etc. as per below
328details.(A) IncomersSuitable capacity MCCB/ACB (Upto 300 KVAR,MCCB and above 300 KVAR, ACB ) Microprocessorbase with O/C, S/C, E/L release of TPN 50KAbreaking capacity (Ics=Icu), ON, OFF, Trip, R, Y, B -LED Indicating Lamp set alongwith requiredInstruments and accessories with extended rotaryhandel and door interlocking arrangment. Currentrating of the Incomer in ampere shall be APFC Panelrating in KVAR x 1.4 x 1.5 or Nearest higher standardsrating.
329a)For Passive Section :i) 3-Phase current sensing APFC microprocessorrelay/controller , advance 12/16 stages (12 stages forover all capacity of panel (active + passive) below 500KVAR and 16 stages 500 KVAR & above) and havingdisplay of Phase wise V, A, PF, Cos-Phi, KW, KVA,KVAR, THD-V , THD-I, harmonics up to 31 level.ii) Auto Manual Selector switch, auxiliary contactorswith timer for delay in manual mode.iii) Digital Multi function meter with LED Display for
330A, PF, KW, KVA, KVAR, THD-V & I, Frequency.iv) Suitable rating control transformer shall beprovided for control and indication circuit.v) All components like control transformer, meter,relay and indicating lamp shall be protected by usingsuitable rating individual MCB's.vi) Wiring of the control circuit shall be done by using2.5 sq mm, FRLS/HFFR 1100 V grade, PVC insulatedmulti stranded copper control wire.vii)Communication Ethernet/RS485/SNMP port openprotocol for BMS integration as per approved byEngineering in charge.
331b) For Active Section : Dedicated HMI(Human Machine Interface) (Minimum 7 inchdisplay) for controlling and communication andhaving display of Phase wise V, A, PF, Cos-Phi, KW,KVA, KVAR, THD-V , THD-I, harmonics up to 50thlevel. Communication Ethernet/RS485/SNMP portopen protocol for BMS integration as per approvedby Engineering in charge
332200 KVAR
333Supply & Erection of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc)in each phase withtouch type selector switches for different readings,instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.
334Main L.T. Panel
335Incoming :
336315A, 50kA 4 Pole MCCB, Ics=100% Icu RatingDigital Voltmeter 0-500V with selector switchAmmeter (0-800 A) with selector swtich & CTs etc.LED type RYB phase indicating lamps, ON, OFF,trip indicating lampsSet of Copper Bus Bar 1000AmpsOutgoings(Note : All outgoing feeders for pumps should havedigital Ammeter with selector switches, and LEDtype ON, OFF, trip indicating lamps)
337Outgoing :
338125 Amp MCCB -4 No. , 40 Amp MCCB -2 NO.& 20 AMP MCB-2NO
339For Main building
340Sub. Panel
341Incoming :
342125A, 50kA 4 Pole MCCB, Ics=100% Icu ratingDigital Voltmeter 0-500V with selector switchDigital Ammeter (0-250 A) with selector swtich &CTs etc.LED type RYB phase indicating lamps, ON, OFF,trip indicating lampsSet of Copper Bus Bar 300AOUTGOING( Note : All outgoing feeders for pumps should havedigital Ammeter with selector switches, and LEDtype ON, OFF, trip indicating lamps)
343Outgoing :
34463 Amp TPN MCB -4 NO.
345UPS OUT GOING PANEL
346Outgoing :
34740Amp 4P MCCB 1, 20AMP 4P -2NO.16AMP 4P -1NO
348(I) AMF Panel:Free standing floor mounted IP 42 automatic mainsfailure control panel including auto by-pass, suitablefor KVA as below for silent type DG set complete withrelays, timers, set of CTs for metering & protection andenergy analyser to indicate currents, phase and linevoltages, frequency, power factor, KWH, Kilo VoltAmpere Reative Hour (KVARH), KVA (Phase & Total),KW & provision for overload, short circuit, restrictedearth fault, under frequency, power (aluminium) andcontrol (copper ) cabling of suitable size upto 15 meterbetween AMF panel, LT Panel and DG Set includingconnection interconnection etc. as required, allcomplete and inter locking and communication/Ethernet /RS485/SNMP port open protocol for BMSintegration including suitable software, the panel shallbe of DG Set OEM make etc. as per approved byEngineering in charge and including the following:1. Suitable numbers and appropriate capacity 4 polemotorised electrically operated draw out with cradletype 3 position ACB/ MCCB with electronic release forO/C & E/F and shunt trip.2. Auto/Manual/Test/Off selector switch
349Protection for under and over voltage phasereversal (2 nos Over voltage relay, 2 Nos. reversepower relay and 2 Nos. under voltage relay).4. 3 Sets of current transformers 15 P 10 accuracy forprotection and 15 VA class-I for metering5. Energy analyser unit to indicate current, Voltage( LN& L_L), kW, kVA (Phase & Total), Frequency, KWH,PF.6. LED Indicating lamps for load on mains and load onset7. Fuse/ MCB for instruments8. Battery charger, complete with transformer/ rectifier,
350D.C. voltmeter and ammeter, selector switch fortrickle, off and boost and current adjustment.9. Main supply failure monitor10. Supply failure timer11. Restoration timer12. Control unit with three impulse automatic enginestart/stop and failure to start lockout.13. Impulse counter with locking and reset facility.14. ON/OFF/Control circuit switch with indicator15. Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning16. Protection for over/under Frequency, Loss of ACsensing, Over Current, Unbalancing load with suitable
351number of relays and accessories17. Maintenance notification based on Engine RunHour & due date.18. Load Management through PLC to achieve autoopening and closing of incomer breakers, bus couplerswitching of essential panel , interlocking providingsignal to AMF Panel for load status and AMF shallgive command to DG Set to auto start / auto stopdepending upon load status and requirement etc. andnecessary hardware and software required to performthe operation shall be provided by the contractorincluding all control wiring.
35262.5KVA
353Supply and fixing of danger board fabricated from 10 gauge M.S. sheet as per I.E.rules.
354Supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting of tested quality.
355ALUMINIUM CABLE
356Laying of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade offollowing size direct in ground including excavation,sand cushioning, protective covering and refilling thetrench etc as required.
357Above 35 sq. mm and upto 95 sq. mm
358Above 95 sq. mm and upto 185 sq.
359Above 185 sq. mm and upto 400 sq. mm
360Supply a of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cablerun shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
36135 sq. mm 3-1/2 core
36250 sqmm 3.5 core
36370 sqmm 3.5 core
36495 sqmm 3.5 core
365120sq. mm 3-1/2 core
366185sq. mm 3-1/2 core
367300sq. mm 3-1/2 core
368Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket,bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in theexisting trench, complete as required.
36963 mm dia (OD-63 mm & ID-51 mm nominal)
37090 mm dia (OD-90 mm & ID-76 mm nominal)
371200 mm dia (OD-200 mm & ID-175 mm nominal)
372Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire
3734 X 10 sq. mm (25mm)
3744 X 16 sq. mm (28mm)
37535 sq. mm 3-1/2 core
37650 sq. mm 3-1/2 core
37770sqmm 3.5 core
37895 sqmm 3.5 core
379120sq. mm 3-1/2 core
380185sq. mm 3-1/2 core
381300sq. mm 3-1/2 core
382Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge.
3834 X 10 sq. mm (25mm)
3844 X 16 sq. mm (28mm)
38535 sq. mm 3-1/2 core
38650 sq. mm 3-1/2 core
38770sqmm 3.5 core
38895 sqmm 3.5 core
389120sq. mm 3-1/2 core
390185sq. mm 3-1/2 core
391300sq. mm 3-1/2 core
392LED LUMINAIRES
393CRCA powder coated white after phosphochromate treatment , High transmittance polystyrene opal diffuser for glare free symmetric light distribution, High efficiency long life LED package in integral module with viewing angle of 120° to ensure better uniformity, Operating temperature: -10 °C to +35 °C, Operating voltage range: 140 V - 270 V, Average life L70B50 : 50000 hours, CRI ≥ 80, THD≤10, PF≥0.95, 240V
394PLANOSUR4X1PLS42WLED857G2S
395MAKE:-HAVELLS;
396Surface mounted downlighter with High Purity (>99%) Aluminum heat sink & PC diffuser in white powder coated finish with Independent electronic LED driver, IP20, IK03,Operating temperature: -10 °C to +35 °C, Operating voltage range: 140 V -270V ,LED Life L70 >50000 hrs, Powered by Independent SMPS based constant current electronic driver with lower THD, Output Short Circuit Protection, Surge Voltage Protection, High efficiency long life SMD LED mounted on MCPCB with high LED efficacy of 165 lm/W, CRI ≥ 80, THD≤10, PF≥0.95, 240V, 1750 Lumens
397INTEGRANXTRDDLRSURD18WLED840S
398MAKE:-HAVELLS;
399Surface mounted downlighter with High Purity (>99%) Aluminum heat sink & PC diffuser in white powder coated finish with Independent electronic LED driver, IP20, IK03,Operating temperature: -10 °C to +35 °C, Operating voltage range: 140 V -270V ,LED Life L70 >50000 hrs, Powered by Independent SMPS based constant current electronic driver with lower THD, Output Short Circuit Protection, Surge Voltage Protection, High efficiency long life SMD LED mounted on MCPCB with high LED efficacy of 165 lm/W, CRI ≥ 80, THD≤10, PF≥0.95, 240V, 1450 Lumens
400INTEGRANXTRDDLRSURD15WLED840S
401MAKE:-HAVELLS;
402Surface mounted downlighter with High Purity (>99%) Aluminum heat sink & PC diffuser in white powder coated finish with Independent electronic LED driver, IP20, IK03,Operating temperature: -10 °C to +35 °C, Operating voltage range: 140 V -270V ,LED Life L70 >50000 hrs, Powered by Independent SMPS based constant current electronic driver with lower THD, Output Short Circuit Protection, Surge Voltage Protection, High efficiency long life SMD LED mounted on MCPCB with high LED efficacy of 165 lm/W, CRI ≥ 80, THD≤10, PF≥0.95, 240V, 850 Lumens
403INTEGRANXTRDDLRSURD9WLED840S
404MAKE:-HAVELLS;
405Housing Made of Aluminum Extrusion with housing part in Anodize finish & diffuser part in opal finish, ABS end caps are snap-fitted to the fixture, Operating temperature: -10 °C to +35 °C, Operating voltage range: 140 V - 270 V, Average life L70B50 : 50000 hours, Integral electronic driver (SMPS based constant current output) with lower THD, Output short circuit protection/Open circuit protection, Surge Voltage Protection and other Safety test as per IS15885 Part 2/ Sec 13, CRI ≥ 80, THD≤20, PF≥0.90, 240V, 2200 Lumens
406LUMILINEPLUSNEOBS22WLED865SPCSSINDS
407MAKE:-HAVELLS;
408LED Panel light 2x2 ft., (System lumen efficacy>135 lm/Watt)
409Supplying, installation, Testing & Commissioning ofPanel light 2x2 ft., of following body material andconstruction as per IS : 10322 with driver as per therequirement with Driver efficiency >85%, Operatingvoltage AC 140-270 Volt, frequency 50/60 hz,Operating temp range -5 0C to 40 0C, internalsurge protection of 2.5 KV with Short & Open circuitprotection, THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free,(flicker should be below 5 %), life time (LED, Driver& electrical circuitry), of minimum 50000 BurningHours with , 70% of initial Lumen maintained tilllife ends ,CCT 3000°K / 4000°K / 5700°K /6500°K(As per ANSI Bin), SDCM(Standard DeviationColour Matching) <3, Maximum powerconsumption should not more than the specifiedrating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. completein all respect i/c external connections with 1.5sq.mm FRLS/HFFR, PVC insulated copperconductor single core cable and earthing etc. as
410Powder coated die cast /Extruded aluminiumBody (Thickness > 1.20 mm)
41145 watt
412Supply and erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required
413Bajaj Freshee Exhaust Fan
414Exhaust Fan heavy duty 450 mm dia
415MAKE:-HAVELLS;
416UPS AND WIRING
417Supplying and drawing following sizes of FRLS/HFFRPVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit asrequired.
4181 x 1.5 sq. mm
419Supplying and fixing of following sizes of mediumclass PVC conduit along with accessories insurface/recess including cutting the wall and makinggood the same in case of recessed conduit asrequired.
42020 mm
421Online UPS- Input supply: Three Phase, Outputsupply: Three Phase.
422Supplying, installation, Testing & Commissioning offollowing capacity at full load (Unity Power Factor)at operating temperature 0 to 40 0C, Relativehumidity 0 to 95%, Online double conversion truesine wave Uninterrupted hot swapable (allow for thereplacement or addition of battery modules withoutshutting down the entire system) modular PowerSupply (UPS) system with N+1 modules (N denotestotal number of modules required for rated capacity).The UPS shall include a Rectifier, inverter, batterybank suitable for 30 minutes back up (Battery VAHcapacity shall not be less than 1600 VAH per KVA ofUPS rating per Hour backup time) on full load(Battery shall be VRLA, SMF in ABS Container) andStatic Bypass switch along with provision for manualbypass, suitable isolation transformer for additionalprotection against neutral faults etc. UPS shall haveinbuilt phase sequence correction. The UPSsystems offered are to be of the latest technologywith Digital Control Microprocessor based for
423reliable operation using Insulated Gate BipolarTransistor (IGBT)'s both for the rectifier & inverter(3 Level) with PWM (Pulse Width Modulation). Thequality of design, manufacturing and inspectionprocess should confirm to the relevant Inter-nationalstandards such as IEC/EN/VDE. The operatingefficiency of the UPS systems shall be >96% whileoperating on battery mode and delivering qualitypower to the 100% non-linear loads. Current totalharmonic effect(ITHD) on the input grid shall be <5% at 50 %load. (The required LC ( inductor (L) anda capacitor (C)) filters shall be included in UPScost), extreme power factor kit to be included to limitthe input power factor (PF) to 0.99 and output powerfactor shall be unity (i.e. kw rating of the UPS shallbe kva rating x 1 ), however UPS shall be suitable totake load at 0.7 laging to 0.7 leading power factorloads. UPS shall be suitable for incoming supplyAC : 3Phase 400V +/-20%, 50 Hz +/-5 Hz, ACOutput voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz,Overload capacity of 120% for 10 mins, Sine waveoutput. Non condensing, noise level less than 60dbat 1 meter distance, protections: Input Under voltageover voltage, abnormal out voltage, battery overcharging, output over current, short circuitprotection, battery deep discharge protection, 10KVsurge. UPS must comply with low voltageelectromagnetic compatibility (EMC) achieved asper EN 6204, EN6204 Part I and Part 2,
424it shall bea Voltage and Frequency Independent (VFI)-typeUPS. . Communication RS232/RS485/SNMP portopen protocol for BMS integration, all hardware &software for iOT Communication as per approved byEngineering in charge. Required battery racks andinterconnecting copper conductor cables of suitablesize and connectors and all required accessoriesare inclusive of the cost). This system must providea means for logging and alarming of all monitoredpoints plus email notification. Forced air-cooling withintegral inbuilt fans with redundancy (if one fan failUPS should be able to handle at least 80% of theload, Noise Level 65 DB at 1 meter distance. Thesystem shall be in compliance IEC 62040- 1,2 & 3,IS: 16242 and CPWD Specification. Display Panel(minimum) (In-build 5 inch or more LC Display /LED) to display : a) Input: Voltage, current,Frequency. b) Bypass: Voltage, Frequency. c)Output: Voltage, frequency, Current. d) Battery:
425Voltage, Capacity. e) Load: KVA, KW, Percentage.f) Temperature: STS, Inverter, PFC. g) EventLogging & Statistical Data (On LCD/LED): UPSshould capture and display up to 3000 events like:Over temperature / DC Bus Fail / Fan Fail / FuseFail / Overload / Short-circuit / Device Fail / InverterFail / Rectifier Fail / Bypass Fail, etc. h) StatisticalData: No. of power failures / Transfers to Bypass /Total Running time, etc. i) Mains Mode of Operation/Battery Mode of Operation / Bypass feeding theload / UPS Fault /Battery charging and discharging,overload, battery voltage and battery capacity. j)Audible Alarms : Mains Failure, Battery Low Alarm,UPS Overload, Fault, Shutdown, Input Over, UnderVoltage, Output Over, Under Voltage, Battery Over,Under Voltage, Over Load and short circuit, OverTemperature. The UPS should have QR codewhich should contain drawing, test report OEMmanual, Geo- Tag of manufacturing location etc
42620KVA (Each Power module shall be < 10 KVA)
427Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
4284 way (4 + 12), Double door
42912 way (4 + 36), Double door
430Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
431Single pole
432Double pole
433Supplying and fixing following rating, four pole, 415 V,isolator in the existing MCB DB complete withconnections, testing and commissioning etc. asrequired.
43440 amps
435CCTV System Equipment
436Camera and accessories
437Supplying Installation Testing and Commissioning of 2 MP IP IR Dome Camera having followingspecifications, type of lens and features etc :-
4381) Signal System: PAL/NTSC, Signal to Noise Ratio:>50 dB, Camera should display Camera title, Date &Time in live & recorded video2)Image Sensor: 1/2.8\\" or better progressive ScanCMOS to get color image even at nightcondition(Minimum Illumination: 0.006 Lux@ F1.4,AGC ON, 0 lux with IR or better) True Day & NightHigh Performance Mechanical IR cut filter with autoswitch, Integrated IR Source (Auto, Manual)- Inbuilt IRLED's with effective distance upto 50 meter or betterand 30 meter for colour view in night, Imaging: 1/3s to1/30000s electronic shutter support, Auto Gain Control, White Balance- Auto, Back Light Compensation,Multi zone Privacy Masking, HLC, DigitalWatermarking.
4393) Compression (Minimum):-Video:- H.265 or better,H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726,AAC, G.7234) Wide Dynamic Range:- WDR (120db or more)5) Digital Noise Reduction:- DNR (3D) On/Off6) Video Streaming & Frame Rates :- Triple streaming, configurable (Main stream: 2MP (1920×1080)@25/30 fps,Sub streams minimum:720P@25/30 fps).7) Image Setting: Rotate Mode, saturation, brightness,contrast, sharpness adjustable through client softwareor web browser, Edge Analytics: Tripwire, Intrusion,Motion Detection8) Cyber Security: AES 256-bit Encryption,Configuration encryption, trusted execution, Digest,security logs, account lockout, syslog, videoencryption, IP/MAC filtering, HTTPS, trusted upgrade,trusted boot.9) Onboard Storage: Camera should support built-inMicro SD/SDHC/SDXC Card slot upto 512 GB. Itshould be supplied with minimum 128GB memoryCard.
4402MP (@ 25/30fps@1080P (1920×1080)) IP IR Dome Camera with 2.8/ 3.6mm fixed lens
441PTZ (Pan. Tilt and Zoom) IP IR Camera
442Supplying Installation Testing and Commissioning ofPTZ (Pan,Tilt and Zoom) IP IR Camera havingfollowing spcifications and features etc :-
4435MP IP IR motorized PTZ @25/30fps or bettercamera, Triple streaming , configurable on resolution:-Main stream: 5MP@25/30 fps Substreams:1080p@25/30 fps, varifocal lens 3.95mm(±5mm) ~ 177.75mm (±5mm) or better with Automatic& manual Focus Adjustment provisions, 45x Opticalzoom and 16x Digital zoom with angle of view H:65.7°–1.9°V: 39.4°–1.1°D: 73.1°–2.1, PAN Travel:Pan: 0° ~ 360° endless,Manual Pan: 260° /s, Preset :300° /s, Tilt Travel: Tilt: -20° ~ 90°, auto flip 180°,Manual Tilt: 120° /s, Preset : 200° /s
444Network Video Recorder (NVR)
445Supplying Installation Testing and Commissioning offollowing Channel Network Video Recorder (NVR)with camera licenses to record for all channels havingspecifications and features etc as mentioned below :1) Network Video Recorder Embedded/ Installed OS(Linux) along with Camera Licenses for number ofchannels of NVR to record per NVR and to provide alive view, storage and simultaneously Multi-channelplayback of all IP, IR camera or more and must beONVIF with minimum support of 256Mbps incomingBandwidth.
44664 Channel Network Video Recorder (NVR) havingdisplay split :- Main screen: 1/4/8/9/16/25/36/64, 2ndscreen: 1/4/8/9/16
447Supplying, Installation, Testing and Commissioningfollowing capacity Serveillance grade Hard Disk withupto 256MB/s Transfer Rate, 256 MB Cache, 7200RPM Disk Speed, 3.5 inch form factor, SATAInterface, BSMI, ICES-003/NNB-003, CE, FCC, KC,Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, ULCertifications.
44810TB (Terabytes)
449LED Display
450Supplying, Installation, Testing and Commissioning offollowing size LED display (LED monitor) industrialgrade with 3840x2160 resolution or better, USBplayback, bluetooth and miracast connectivity, 4XHDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nitsor better, Video wall mode should be available,contrast ratio: 1200:1, OPS slot, viewing angle (H/V):170°/ 170°, response time less than 12ms, Displaycontrol shall be on monitor screen and programmablewith remote (remote shall be supplied with system),Key Board, Optical Mouse, etc. as required.
45132 inch or larger
452EXPNSION IO MODULESupplying Installation Testing Commissioning offollowing type of input output (IO) expansion modulecomplete etc. as required.
453I/O Module with 16 DI channels
454Supplying, installation, Testing and commissioning offollowing capacity 8 port Layer 2 indoor NetworkSwitch having features and specifications etc. asmentioned here under: Minimum 8 X RJ-45 GigabitEthernet Ports and additional 2 X 1G SFP Ports withnon-blocking architecture by having Switching capacityof minimum 20Gbps and packet forwarding rate of14Mpps or higher, 8K MAC table. Internal dual ACPower supply with operating temperature of -5 0C to+50 0C. Jumbo frame: 10KB or higher, IGMPSnooping, IGMP snooping querier and support forIGMP Snooping Fast Leave, Should create 250 ormore MLD groups, MLD Snooping, Per VLAN MLDSnooping C MLD Snooping Fast Leave, STP, RSTP,MSTP, Loopback detection, Multicast filtering, VLANTagging, ǪOS: 8 Ǫue per port, WRR, IPv4/IPv6Interface : minimum 100 IPv4 static route entries andminimum 50 IPv6 static route entries, 700 AcessControl entries, SSH CSSL for IPv4 and IPv6, 802.1x,ARP Spoofing, DHCP Snooping and server screening,IP+MAC+Port Binding, Per Port Bandwidth Control,802.1X Authentication (Supports local/RADIUSdatabase, Port-based Access Control and EAP, OTP,TLS, TTLS, PEAP Support) Cable Diagnostic feature,LLDP, LLDP-MED, SNTP/NTP, RMON, SNMP v1,v2c,v3 and SNMP Traps. Certifications: UL, CE, FCC,RoHS, MTCTE, OEM/Product must be on TrustedTelecom Portal of Department of Telecommunication,Government of India etc. complete as required
45524 port PoE Layer 2 Network Switch with PoESupport of 370W or higher with each copper portsupporting 802.3at PoE+ min.
456Supplying Installation Testing and Commissioning of24 port Cat6 Patch Panel loaded. Must be of 1U heightwith clear label holders and white label with the panel.24 Ports Cat-6 Patch Panel should have ETL/ULverification program certificate for compliance withANSI/TIA-568.2-D etc. complete as required
457Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plateof color as per site requirement, should have ETL/UL verification program certificate for compliance withANSI/TIA-568.2-D. All copper Cable and Componentsshould be from same OEM to maintain compatibilityand interoperability etc. complete as required
458Supplying, Installation, Testing and commissioning ofRJ45 Connector for CAT 6/6A Cables. RJ45 modularplug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color,Use for 24- 26 AWG stranded wires etc. complete asrequired.
459Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG TwistedPair Cable in existing conduit/ on surface, Category 6Unshielded Twisted Pair, 4 pair should be complied asper UL/ETL verification program for compliance withANSI/TIA-568.2-D standard. Outer diameter should bein the range of 6.1mm nominal with OperatingTemperature Range : -5° to +60°C, Bending Radius :< 4 X Cable Diameter at –5°C ± 1°C and Pulling Force: 11.5Kg etc. complete as required.
4601 Run of cable
461Supplying and drawing following core Multi modeFiber Optic Cable having corrugated steel armoring,leser optimize 50/125 μm with HDPE jacket, LSZH(Low smoke Zero Halogen), Tight-buffered or loosetube, maximum attenuation: < 3.5 dB/km at 850 nm, <1.5 dB/km at 1300 nm, bandwidth > 2000 MHz-km at850 nm, > 500 MHz-km at 1300 nm compliance andcertifications: ISO/IEC 11801 Ed. 2.2, ANSI/TIA-568-C.3, ITU-T G.651.1 RoHS compliant. Multi Mode Fibershall be Central-loose tube filled with Thixotropic jelly,duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-
46220-core, High quality Electro Chromium CoatedCorrugated Steel tape (ECCS ) and HDPE- Sheath,Operating ambient Temperature should be – 5 0C to+50 0C and Storage Temperature should be – 5 0C to+50 0C, Maximum Attenuation ± 3.5 dB/km atOperational Wavelength 850 nm and ± 1.5 dB / km atOperational Wavelength 1300 nm . type of fibershould be 50/125 / G.652D & Refractive Index shouldbe 1.483/1.478, The value for Mode-filed,CladdingDiameter 50 ± 2.5 μm and 125 ± 1μm correspondinglyi/c splicing & marking etc complete as required.
463Single Mode 6 Core Optical fiber cable
464Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in,metal splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered fiber storing, Capableof storing up to 3 meters of 900μm tight buffered fiber
4656 Port LIU
46624 Port LIU
467Supplying and fixing Patch Cord of Optical Fiber Multi Mode or Single Mode LC to LC Fiber Duplex havinghigh precision ceramic ferrule with good concentricity, Fiber corning single mode G652D, Cable Type 2mmwith Mechanical specification Apex Offset < 50 μm, Fiber Height + 100 nm, End-face radius of Curvature7mm < R <25mm, Repeatability < 0.2 db, Working ambient Temperature – 5 0C to +50 0C, Storage Temperature – 10 0C to +50 0C, Length -- 2meter,Type -- LC-LC Duplex etc complete as required
468Supplying, Installation, Testing and commissioning offollowing CAT6 Patch Cord should have ETL/ULverification program certificate for compliance withANSI/TIA-568.2-D etc. complete as required.
469Copper Patch Cords of length 1m (3ft)
470Copper Patch Cords of length 3m (10ft)
471Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and makinggood the same in case of recessed conduit asrequired.
47220 mm
473Supplying and fixing of following size Wall MountRack having Fixed Structure with 0.8mm CRCASheet, completely knocked-down condition (CKD)Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking,Minimum 2 cable entry/exit provision at Top andbottom with rubber protection, Front 5mm ToughenedGlass with lock, wall mounting kit, Powder coatedColor- RAL- 7035, complied with UL & RoHS, 2 x 6sockets 16A power distribution units, 3 numbersclosed cable organizer, Hardware mounting screwspacket of 20 x 1 number, etc. complete as required
47415U Rack
475Supplying and fixing 24U Rack with 4 inch Castorwheels and front brake Floor Standing Rack withMain Frame Pillar of 1.25mm Powder Coated CRCASheet with removable side panels, L- Shapeadjustable Vertical Mounting Rail of 2mm with'U'Marking completely knocked-down condition (CKD)Shape, fitted with 4 number cooling fans, minimum5nos two line cable entry/exit provision at top and bottom with rubber protection, Front door 5mmToughened Glass with MS frame or MS perforatedwith lock, Rear MS vented or perforated door,Powder coated Color- RAL- 7035 or black, compliedwith UL & RoHS, 2 x 6 sockets 16A power distributionunits, 3 numbers closed cable organizer, Hardwaremounting screws packet of 20 x 1 number, etc.complete as required.
476Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
4772 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
478LAN System Equipment
479Supplying, Installation, Testing and commissioning ofCAT6 Copper Information Outlet (IO) with face plateof color as per site requirement, should have ETL/ULverification program certificate for compliance withANSI/TIA-568.2-D. All copper Cable and Componentsshould be from same OEM to maintain compatibilityand interoperability etc. complete as required.
480Supplying, installation, Testing and commissioning offollowing capacity 24 port Layer 3 Network Switchhaving features and specifications etc. as mentionedhere under: At least 20 X RJ-45 Gigabit Ethernet Portsand additional 4 combo 10/100/1000 base-t/SFP Portswith additional 4 SFP+ ports non-blocking architectureby having Switching capacity of min. 128Gbps andpacket forwarding rate of 95Mpps or higher, 16K MACtable. Console Port, USB port, Internal AC Powersupply with operating temperature of 0 to +50 0C.Stacking port with stacking support of minimum 8 unitsper stack. 48K Mac address, 9K or more Jumboframe, ERPS with enabling ring to converge in lessthan 50 ms from node or link failure, Static routing,Static, 6to4, ISATAP and GRE, IPv6 NeighborDiscovery (ND), BGP, ISIS, MPLS, VRRP v2,
481OSPFv2/v3, PBR, Route Redistribution, RIPv1/v2/ng,IP Helper all L3 Protocols should support from day 1for both IPv6 and IPv4, 802.1x, Port security , RadiusC TACACS+ authentication C accounting, DAD, DAI,DoS attack prevention, SSH, Guest VLAN, IP AccessList, MAC Access List. Multicast: VLAN, PIM-SM, PIMDM,PIM- SDM, PIM-SMv6, DVMRP v3 and MSDP,IGMP C MLD Snooping, Flow mirroring, IGMP C MLDSnooping Ǫuerier, Per-VLAN IGMP C MLD Snooping.SNMP, Dual configurations, Multiple images, RMON,LLDP/LLDP-MED, sFlow, DHCP/BOOTP Client,IPv4/IPv6, Syslog server, Debug command, 802.3ahEthernet Link OAM, 802.1ag Connectivity Fault,Y.1731 OAM, 802.1Ǫbb Priority- based Flow Control(PFC), Dying Gasp, Cable Diagnostics , 6 kV surgeprotection on all Gigabit Ethernet ports and on all GERJ-45 access ports. Certifications: UL, CE, FCC,RoHS, MTCTE, OEM/Product must be on TrustedTelecom Portal of Department of Telecommunication,Government of India etc. complete as required.
482Supplying Installation Testing and Commissioning of24 port Cat6 Patch Panel loaded. Must be of 1U heightwith clear label holders and white label with the panel.
48324 Ports Cat-6 Patch Panel should have ETL/ULverification program certificate for compliance withANSI/TIA-568.2-D etc. complete as required
484Supplying, Installation, Testing and commissioning offollowing CAT6 Patch Cord should have ETL/ULverification program certificate for compliance withANSI/TIA-568.2-D etc. complete as required.
485Copper Patch Cords of length 1m (3ft)
486Copper Patch Cords of length 3m (10ft)
487Supplying, Installation, Testing and commissioning ofRJ45 Connector for CAT 6/6A Cables. RJ45 modularplug supports 4 twisted pairs, 8 positions, 8connectors. Housing: PC, UL94V-2, transparent color,Use for 24- 26 AWG stranded wires etc. complete asrequired.
488Supplying and fixing Patch Cord of Optical Fiber MultiMode or Single Mode LC to LC Fiber Duplex havinghigh precision ceramic ferrule with good concentricity,Fiber corning single mode G652D, Cable Type 2mmwith Mechanical specification Apex Offset < 50 μm,Fiber Height + 100 nm, End-face radius of Curvature7mm < R <25mm, Repeatability < 0.2 db, Workingambient Temperature – 5 0C to +50 0C, StorageTemperature – 10 0C to +50 0C, Length -- 2meter,Type -- LC-LC Duplex etc complete as required.
489Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG TwistedPair Cable in existing conduit/ on surface, Category 6Unshielded Twisted Pair, 4 pair should be complied asper UL/ETL verification program for compliance withANSI/TIA-568.2-D standard. Outer diameter should bein the range of 6.1mm nominal with OperatingTemperature Range : -5° to +60°C, Bending Radius :< 4 X Cable Diameter at –5°C ± 1°C and Pulling Force: 11.5Kg etc. complete as required.
4901 Run of cable
491Supplying and drawing following core Multi modeFiber Optic Cable having corrugated steel armoring,leser optimize 50/125 μm with HDPE jacket, LSZH(Low smoke Zero Halogen), Tight-buffered or loosetube, maximum attenuation: < 3.5 dB/km at 850 nm, <1.5 dB/km at 1300 nm, bandwidth > 2000 MHz-km at850 nm, > 500 MHz-km at 1300 nm compliance andcertifications: ISO/IEC 11801 Ed. 2.2, ANSI/TIA-568-C.3, ITU-T G.651.1 RoHS compliant. Multi Mode Fibershall be Central-loose tube filled with Thixotropic jelly,duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-
49220-core, High quality Electro Chromium CoatedCorrugated Steel tape (ECCS ) and HDPE- Sheath,Operating ambient Temperature should be – 5 0C to+50 0C and Storage Temperature should be – 5 0C to+50 0C, Maximum Attenuation ± 3.5 dB/km atOperational Wavelength 850 nm and ± 1.5 dB / km atOperational Wavelength 1300 nm . type of fibershould be 50/125 / G.652D & Refractive Index shouldbe 1.483/1.478, The value for Mode-filed,CladdingDiameter 50 ± 2.5 μm and 125 ± 1μm correspondinglyi/c splicing & marking etc complete as required.
493Single Mode 6 Core Optical fiber cable
494Supplying and fixing of following sizes of mediumclass PVC conduit along with accessories insurface/recess including cutting the wall and makinggood the same in case of recessed conduit asrequired.
49520 mm
496Supply and fixing following port Rack Mount loadedLIU with pigtail, Front-mounted cable saddles forjumper management, suitable to manage both splicesand terminations, Pre-assembled shelves in multipleconfigurations, Rubber fiber slotted bracket built-in,metal splice shelf to protect the fibers, 2 fiber spoolsbuilt-in for 900μm tight buffered fiber storing, Capableof storing up to 3 meters of 900μm tight buffered fiber
497per adapter, Removable front and rear covers forbetter access to interior of LIU, Should be Single /Multi mode LC Type fully loaded. Accessory kitconsists of cable ties, mounting ear screws, and spiralwrap tube etc complete as required.
4986Port LIU
49924 Port LIU
500Supplying and fixing 42U Rack with 6 inch Castorwheels and front brake Floor Standing Rack withMain Frame Pillar of 1.6mm CRCA Sheet withremovable side panels, L- Shape adjustable VerticalMounting Rail of 2mm with 'U'Marking completelyknocked-down condition (CKD) Shape, fitted with 4number cooling fans, minimum 8nos two line cableentry/exit provision at top and bottom with rubberprotection, Front door 5mm Toughened Glass withMS frame or MS perforated with lock, Rear MS ventedor perforated door, Powder coated Color- RAL- 7035or black, complied with UL & RoHS, 2 x 6 sockets 16Apower distribution units, 3 numbers closed cableorganizer, Hardware mounting screws packet of 20 x 1number, etc. complete as required.
501Supplying, installation, Testing and commissioning offollowing capacity 24 port Layer 3 Network Switchhaving features and specifications etc. as mentionedhere under: At least 20 X RJ-45 Gigabit Ethernet Portsand additional 4 combo 10/100/1000 base-t/SFP Portswith additional 4 SFP+ ports non-blocking architectureby having Switching capacity of min. 128Gbps andpacket forwarding rate of 95Mpps or higher, 16K MACtable. Console Port, USB port, Internal AC Powersupply with operating temperature of 0 to +50 0C.Stacking port with stacking support of minimum 8 unitsper stack. 48K Mac address, 9K or more Jumboframe, ERPS with enabling ring to converge in lessthan 50 ms from node or link failure, Static routing,Static, 6to4, ISATAP and GRE, IPv6 NeighborDiscovery (ND), BGP, ISIS, MPLS, VRRP v2,OSPFv2/v3, PBR, Route Redistribution, RIPv1/v2/ng,IP Helper all L3 Protocols should support from day 1for both IPv6 and IPv4, 802.1x, Port security , RadiusC TACACS+ authentication C accounting, DAD, DAI,DoS attack prevention, SSH, Guest VLAN, IP AccessList, MAC Access List. Multicast: VLAN, PIM-SM, PIMDM,PIM- SDM, PIM-SMv6, DVMRP v3 and MSDP,IGMP C MLD Snooping, Flow mirroring, IGMP C MLDSnooping Ǫuerier, Per-VLAN IGMP C MLD Snooping.SNMP, Dual configurations, Multiple images, RMON,LLDP/LLDP-MED, sFlow, DHCP/BOOTP Client,IPv4/IPv6, Syslog server, Debug command, 802.3ahEthernet Link OAM, 802.1ag Connectivity Fault,Y.1731 OAM, 802.1Ǫbb Priority- based
502Flow Control(PFC), Dying Gasp, Cable Diagnostics , 6 kV surgeprotection on all Gigabit Ethernet ports and on all GERJ-45 access ports. Certifications: UL, CE, FCC,RoHS, MTCTE, OEM/Product must be on TrustedTelecom Portal of Department of Telecommunication,Government of India etc. complete as required.
503Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in,metal splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered fiber storing, Capableof storing up to 3 meters of 900μm tight buffered fiber
5046 Port LIU
50524 Port LIU
506Supplying, Installation, Testing and commissioning ofsmall form-Pluggable (SFP) for Network Switches.Must be hot Pluggable, RoHS Complaint, etc.complete as required.
5071G SFP Single Mode/Multi Mode
508Supplying and fixing of following size Wall MountRack having Fixed Structure with 0.8mm CRCASheet, completely knocked-down condition (CKD)Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking,Minimum 2 cable entry/exit provision at Top andbottom with rubber protection, Front 5mm ToughenedGlass with lock, wall mounting kit, Powder coatedColor- RAL- 7035, complied with UL & RoHS, 2 x 6sockets 16A power distribution units, 3 numbersclosed cable organizer, Hardware mounting screwspacket of 20 x 1 number, etc. complete as required
50915U Rack
510RAIN WATER HARVESTING WITH 2 nos
5112 point
512Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m.
513In all kind of soil upto 1.5m depth
514In all kind of soil upto 1.5m to 3.0m. depth
515In all kind of soil upto 3.0m to 4.5m. depth
516Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors.
517Brick work with common burnt clay F.P.S. (non modular brick) bricks of class designation 7.5 in foundation and plinth in: .
518Cement mortar 1:4 (1 cement : 4 coarse sand)
519Reinforced cement concrete work in beams, suspended floor, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral stair cases above plinth level up to the floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1cement: 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregrate 20mm nominal size derived from natural sources).
520R.C.C. work in Slab
521Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level
522thermo-mechnically treated bars
523Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.
52420 mm cement plaster
525Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:
526With 20x20mm square bar
527Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
528M.D. -10- Circular shape 500mm internal diameter
529Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.
530Drilling of 300mm dia bore hole manually.
531Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
532150 mm nominal size dia
533Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge.
534Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
535Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
536DESILTING CHAMBER
537Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m.
538In all kind of soil upto 1.5m depth
539Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors.
540Brick work with common burnt clay F.P.S. (non modular brick) bricks of class designation 7.5 in foundation and plinth in: .
541Cement mortar 1:4 (1 cement : 4 coarse sand)
542Reinforced cement concrete work in beams, suspended floor, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral stair cases above plinth level up to the floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1cement: 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregrate 20mm nominal size derived from natural sources).
543R.C.C. work in Slab
544Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level
545thermo-mechnically treated bars
54615 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand)
547Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:
548With 20x20mm square bar
549Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
550M.D. -10- Circular shape 500mm internal diameter
551DESILTING CHAMBER
552Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m.
553In all kind of soil upto 1.5m depth
554Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors.
555Brick work with common burnt clay F.P.S. (non modular brick) bricks of class designation 7.5 in foundation and plinth in: .
556Cement mortar 1:4 (1 cement : 4 coarse sand)
557Reinforced cement concrete work in beams, suspended floor, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral stair cases above plinth level up to the floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1cement: 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregrate 20mm nominal size derived from natural sources).
558R.C.C. work in Slab
559Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level
560thermo-mechnically treated bars
56115 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand)
562Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:
563With 20x20mm square bar
564Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
565M.D. -10- Circular shape 500mm internal diameter
566DRAINAGE NETWORK
567Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m.
568Pipes 80 mm to 300 mm diameter
569Supplying and laying of following size DWC HDPEpipe ISI marked along with all accessories like socket,bend, couplers etc. conforming to IS 14930, Part IIcomplete with fitting and cutting, jointing etc. in theexisting trench, complete as required.
570160 mm dia (OD-160 mm & ID-135 mm nominal)
571200 mm dia (OD-200 mm & ID-175 mm nominal)
572250 mm. dia.
573Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design
574150 mm. dia.
575200 mm. dia.
576250 mm. dia.
577Constructing brick masonry chamber for underground C.I. inspectionchamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarsesand) C.I. cover with frame (light duty) 455x610 mm internal dimensions,total weight of cover with frame to be not less than 38 kg (weight of cover23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stoneaggregate 40 mm nominal size), inside plastering 12 mm thick withcement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with afloating coat of neat cement on walls and bed concrete etc. complete asper standard design
578Inside dimensions 455x610 mm and 45 cm deep for single pipe line :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
579Extra for depth beyond 45 cm of brick masonry chamber :
580For 455x610 mm size
581With common burnt clay F.P.S. (non modular)bricks of class designation 7.5
582TYPE- III(G+3)- 8 UNIT
583UP TOPLINTH LVL
584Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
585All kinds of soil
586Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
587All kinds of soil
588Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
589Ground floor
590Supply and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
591Ground floor
592Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
5931:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
594Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment(excluding the cost of chemical emulsion) :
595Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart.
596Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in
597Cement Mortar 1:6 (1 Cement : 6 Coarse sand)
598Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
599Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
600RCC WORK
601providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland Slag cement, admixtures in recommended proportions as per iS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
602All works upto plinth level
603concrete of M25 grade with minimum cement content of 330 kg /cum
604TIE BEAM
605PLINTH BAND
606COLUMN
607Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
608Thermo-Mechanically Treated bars of grade Fe-500D or more.
609UP TO plinth Lvl.
610Centering and shuttering including strutting, propping etc. and removal of form for
611Tie Beam
612PLINTH BAND
613Column
61415 mm cement plaster of mix :
6151:4 (1 cement: 4coarse sand)
616Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
61740 mm thick with 20 mm nominal size stone aggregate
618APPRON DRAIN ALONG APPRON 150X150
619SUPER STRUCTURE
620Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
621Providing and laying Autoclaved Aerated concrete blosks masonry 100 mm/ 125 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work
622Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor five level in :Cement mortar 1:6 (1 cement : 6 coarse sand)
623RCC WORK ABOVE PLINTH
624Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland Slag cement, admixtures in recommended proportions as per iS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
625All works above plinth level upto floor V level
626Concrete of m25 grade with minimum cement content of 330 kg /cum
627LINTEL BAND
628SILL BAND
629COLUMN
630Centering and shuttering including strutting, propping etc. and removal of form for
631LINTEL BAND
632SILL BAND
633Column
634Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
635Thermo-Mechanically Treated bars of grade Fe-500D or more.
636Above plinth Lvl.
637WOOD WORK
638Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
63935 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
64025 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS: 3818 marked with necessory screwsStainless Steel butt hinges with necessary screws
641Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wireof dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows andclerestory windows with necessary screws :
64235 mm thick shutters
643with ISI marked M.S. pressed butt hinges bright finished of required size
644Second class teak wood
645Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.
646Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of leadfree uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extrude dprofiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and designduly reinforced with galvanized mild steel section made of required shape & size as perCPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (whereever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fastenersof minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 gradesleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plasticcaps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required)shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, includingdrilling of holes for fixing hardware and drainage of water etc. After fixing frame the gapbetween frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conformingto CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcementand cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.
647Three track three panels sliding window with two glazed & one wire mesh panels withAluminium channel for roller track, wool pile, nylon rollers with SS 304 body.
648Using R4 series with frame (115mm & above) x (45mm & above) & both glazed and fly screen sash (44mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height above 1.8m)
649Providing and fixing fly proof Wiremesh , to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.
650With 12 mm mild steel U beading
651Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
652Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
653Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
654Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
655Using M.S. angels 40x40x6 mm for diagonal braces
656Providing and fixing glazing in aluminium door, window, ventilator shutters and partitionsetc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings andthe directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basicitem):
657With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
658Providing and fixing ISI marked S.S. sliding door bolts with nuts and screws etc. complete :
659300x16 mm
660Providing and fixing ISI marked S.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete
661250x10 mm
662Providing and fixing ISI marked .S.S. handles conforming to IS:4992 with necessary screws etc. complete :
663125 mm
664Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete :
66520 MM DIA
666Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
667PLASTER WORK
66815 mm cement plaster of mix :
6691 : 6 (1 cement : 6 coarse sand)
670Extra for plastering exterior walls of height more than 10 m fromground level for every additional height of 3 m or part thereof.
67112 mm cement plaster of mix :
6721 : 6 (1 cement : 6 coarse sand)
673Extra for plastering exterior walls of height more than 10 m fromground level for every additional height of 3 m or part thereof.
674Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
675FLOORING
676Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
67725 mm thick
678Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishingcomplete.
679Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.
680Granite stone slab of colour black, Cherry/Ruby red
681Area of slab over 0.50 sqm
682Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
683Size of Tile 600x600 mm
684Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).
685Size of Tile 600x600 mm
686Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
687Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand)and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
688FINISHING WORK
689Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
690Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
691Steel work
692Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coatapplied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approvedbrand and manufacture
693Finishing walls with Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
694Outer side
695Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour all complete, as per manufacturer's specification.
696New work ( two or more coats ) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre.
697Inner wall surface
698Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour all complete, as per manufacturer's specification.
699New work ( two or more coats ) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre.
700CEILING
701Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
702Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5
703(1cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm heightincluding rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm ofcement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-incharge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand)admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the
704With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
705Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of alljoints, corners, junctions of pipes and masonry with polymer mixed slurry.
706TYPE- III(G+3)- 8 UNIT
707INTERNAL SANITARY W/S INTALLATION WORKS
708SANITARY INSTALLATIONS & FITTINGS
709Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
710W.C. pan with ISI marked black solid plastic seat and lid
711Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
712Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
713a)White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
714Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
715Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
716Kitchen sink with drain board
717510x1040 mm bowl depth 250 mm
718Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
719Semi rigid pipe
72032 mm dia
721Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
722Providing and fixing PTMT Bottle Trap for Wash basin and sink
723Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms
724Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
725Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
726600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
727C.P. BRASS FITTINGS
728Providing and fixing unplasticised PVC connection pipe with brass unions
72945 cm length
73015 mm nominal bore
731Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
73215 mm nominal bore
733Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
73415 mm nominal bore
735INTERNAL SOIL /WASTE PIPE LINE
736Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
737110mm (Rainwater+soil+waste)
738Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.
739110 mm diameter
740Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
741Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
742Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
743Bend 87.5°
744110 mm bend
745Shoe (Plain)
746110 mm Shoe
747Providing and fixing of UPVC SWR pipe type -B confirming to IS -13592 including jointing the pipe with rubbing ring ,lubricant and UPVC SWR cupler confirming to IS -14735 ,ALSO Including excavation of trenches cutting of walls and holes and repairing the walls ,floors and refiling the trenches as before but excluding supply and cost of other fitting such as elbow bead ,tee and Y -tee including supply of all materials labour and t&p .Required for proper completion of the work .
748a) 110mm dia P.V.C. pipe
749b) 75mm dia P.V.C. pipe
750Providing and fixing of UPVC SWR door bend confirming to IS-14735.
751110MM
752Providing and fixing of UPVC Nahani trap size 100/75mm ,100/90 mm confirming to IS -14735 self cleaning design fixed in pcc 1:2:4 and supply and fixing of 125mm dia heavt duty cp brass jali.
753Providing and fixing of UPVC SWR cowl confirming to IS-14735.
754110MM
755Providing and fixing of UPVC Plain TEE confirming to IS-14735.
75675X75X75MM
757110X110X110MM
758Providing and fixing of UPVC SWR door y confirming to IS-14735.
759110MM
760INTERNAL WATER SUPPLY WORKS
761Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.
762Concealed work including cutting chases and making good the walls etc.
76315mm dia nominal outer dia pipes
76420mm dia nominal outer dia pipes
765Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.
766Internal work-Exposed on wall
76725mm dia nominal bore
76832mm dia nominal bore
769Providing and fixing gun metal gate valve with wheel of approved quality.
77025mm dia nominal bore
77132mm dia nominal bore
772Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license].
773Capcity in Per Liters
774Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete
77525 mm nominal bore
7762 nominal
777W I R I N G
778Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
779Group A
780Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
781Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
782Group C
783Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
7842 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
7852 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
7862 X 4 sq. mm + 1 X 4 sq. mm earth wire
7872 X 6 sq. mm + 1 X 6 sq. mm earth wire
7884 X 16 sq. mm + 2 X 16 sq. mm earth wire
789Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
790Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
791Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
792Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
793Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
794Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
795Upto 450 mm sweep
796Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copperconductor, unarmored telephone cable in the existingsurface/ recessed steel/ PVC conduit as required.
7971 Pair
798Supplying and drawing co-axial TV cable RG-6 grade,0.7 mm solid copper conductor PE insulated, shieldedwith fine tinned copper braid and protected with PVCsheath in the existing surface/ recessed steel/ PVCconduit as required.
799Supplying and fixing of following sizes of mediumclass PVC conduit along with accessories insurface/recess including cutting the wall and makinggood the same in case of recessed conduit asrequired.
80020 mm
801Supplying and fixing metal box of following sizes(nominal size) on surface or in recess with suitablesize of phenolic laminated sheet cover in frontincluding painting etc. as required.
802150 mm X 75 mm X 60 mm deep
803Supplying and fixing following piano type switch/socket on the existing switch box/ cover includingconnections etc. as required.
804Telephone socket outlet
805TV antenna socket outlet
806Bell push
807Supplying and fixing following modular switch/ socketon the existing modular plate & switch box includingconnections but excluding modular plate etc. asrequired.
808Telephone socket outlet
809TV antenna socket outlet
810Bell push
811Supplying and fixing following size/ modules, GI boxalong with modular base & cover plate for modularswitches in recess etc. as required.
8124 Module (125mmX75mm)
813Providing and fixing connecting and testing of telephone tag block in MS box with hinged and lockable cover duly painted over primer as required.
81410 /20 Pair
815MCCB, MCB & DB'S
816Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
8178 way (4 + 24), Double door
818Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
819Single pole
820Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
82125 amps
82240 amps
82363 amps
824Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required
825Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
826E A R T H I N G
827Earthing with G.I. earth plate 600 mm X 600 mm X 6mm thick including accessories, and providingmasonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 Meter long etc.with charcoal/ coke and salt as required.
828Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
829Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
830Supply, Installation, Testing and Commissioning ofceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. metal( Aluminiumalloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessoriesincluding safety pin, nut bolts, washers, temperaturerise=75 0C (max.), insulation resistance more than 2mega ohm, suitable for 230 V, 50 Hz, single phase ACsupply, Ceiling Fan compliant to IS 374:2019 fan i/cexternal connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cableand earthing etc. as required.
8311200mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 210 CM/Min (Minimum)
832Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shallbe made of 12 mm dia M.S. bar bent to shape as per standard drawing.
833Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cablerun shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
83470 sqmm 3.5 core
835Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire
83670 sqmm 3.5 core
837Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge.
83870 sqmm 3.5 core
839Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only
840Main L.T. Panel
841Incoming :
842200 Amp. MCCB-1 Nos.
843Outgoing :
84463 Amp. MCCB-3 Nos.
845Supply and fixing of danger board fabricated from 10 gauge M.S. sheet as per I.E.rules.
846Supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting of tested quality.
847Supply & fixing of Crimping, solder, less, copper ton electroplated lugs of Dowel/ismail make suitable for 1.5 sqmm to 6sqmm cables, including tapping with insulating tape, etc. complete in all respects.
848LED Batten light (System lumen efficacy >135lm/Watt)
849Powder coated die cast /Extruded aluminiumBody (Thickness > 1.20 mm)
85018- 22 Watt
851MAKE:-HAVELLS;
852Supply and fixing of bracket light including connections etc. complete as required
85310-15 watt
854MAKE:-HAVELLS;
855Supply and erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required
856Exhaust Fan
857MAKE:-HAVELLS;
858TYPE- V- 01 NOS
859BILL OF QUANTITY
860UP TOPLINTH LVL
861Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
862All kinds of soil
863Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
864Ground floor
865Supply and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
866Ground floor
867Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
8681:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
869Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment(excluding the cost of chemical emulsion) :
870Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart.
871Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in
872Cement Mortar 1:6 (1 Cement : 6 Coarse sand)
873Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
874Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
875RCC WORK UPTO PLINTH
876providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland Slag cement, admixtures in recommended proportions as per iS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
877All works upto plinth level
878concrete of m25 grade with minimum cement content of 330 kg /cum
879TIE BEAM
880PLINTH BAND
881COLUMN
882Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
883Thermo-Mechanically Treated bars of grade Fe-500D or more.
884UP TO plinth Lvl.
885Centering and shuttering including strutting, propping etc. and removal of form for
886Tie Beam
887PLINTH BAND
888Column
88915 mm cement plaster of mix :
8901:4 (1 cement: 4coarse sand)
891Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
89225 mm thick with 20 mm nominal size stone aggregate
89325/40*614.20
894APPRON DRAIN ALONG APPRON 150X150
895B SUPER STRUCTURE
896Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
897Providing and laying Autoclaved Aerated concrete blosks masonry 100 mm/ 125 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work
898Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor five level in :Cement mortar 1:6 (1 cement : 6 coarse sand)
899RCC WORK ABOVE PLINTH
900providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland Slag cement, admixtures in recommended proportions as per iS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
901All works above plinth level upto floor V level
902concrete of m25 grade with minimum cement content of 330 kg /cum
903LINTEL BAND
904SILL BAND
905COLUMN
906Centering and shuttering including strutting, propping etc. and removal of form for
907LINTEL BAND
908SILL BAND
909Column
910Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
911Thermo-Mechanically Treated bars of grade Fe-500D or more.
912Above plinth Lvl.
913WOOD WORK
914Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
91535 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
91625 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws
917Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wireof dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows andclerestory windows with necessary screws :
91835 mm thick shutters
919with ISI marked M.S. pressed butt hinges bright finished of required size
920Second class teak wood
921Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of leadfree uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extrude dprofiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and designduly reinforced with galvanized mild steel section made of required shape & size as perCPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (whereever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fastenersof minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 gradesleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plasticcaps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required)shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, includingdrilling of holes for fixing hardware and drainage of water etc. After fixing frame the gapbetween frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conformingto CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcementand cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.
922Three track three panels sliding window with two glazed & one wire mesh panels withAluminium channel for roller track, wool pile, nylon rollers with SS 304 body.
923Using R3 series with frame (98mm & above) x (40mm & above) & both glazed and fly screensash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle onevery glazed panel along with multi-point locking system. (Height upto 1.8m).Window Upvc Frame
924Providing and fixing fly proof Wiremesh , to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.
925With 12 mm mild steel U beading
926Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
927Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
928Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
929Providing and fixing glazing in aluminium door, window, ventilator shutters and partitionsetc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings andthe directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basicitem):
930With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
931Providing and fixing ISI marked S.S. sliding door bolts with nuts and screws etc. complete :
932300x16 mm
933Providing and fixing ISI marked S.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete
934250x10 mm
935Providing and fixing ISI marked .S.S. handles conforming to IS:4992 with necessary screws etc. complete :
936125 mm
937Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.
938PLASTER WORK
93915 mm cement plaster of mix :
9401 : 6 (1 cement : 6 coarse sand)
94112 mm cement plaster of mix :
9421 : 6 (1 cement : 6 coarse sand)
943Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
944FLOORING
945Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
94625 mm thick
947Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishingcomplete.
948GROUND FLOOR
949Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.
950Granite stone slab of colour black, Cherry/Ruby red
951Area of slab over 0.50 sqm
952Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
953Size of Tile 600x600 mm
954Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).
955Size of Tile 600x600 mm
956Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
957Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand)and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
958FINISHING WORK
959Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
960Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
961Steel work
962Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coatapplied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approvedbrand and manufacture
963Finishing walls with Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
964Outer side
965Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour all complete, as per manufacturer's specification.
966New work ( two or more coats ) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre.
967Inner wall surface
968Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour all complete, as per manufacturer's specification.
969New work ( two or more coats ) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre.
970CEILING
971Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
972Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5
973(1cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm heightincluding rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm ofcement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-incharge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand)admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the
974With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
975TYPE- V- 01 NOS
976INTERNAL SANITARY W/S INTALLATION WORKS
977SANITARY INSTALLATIONS & FITTINGS
978Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
979White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
980Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
981W.C. pan with ISI marked black solid plastic seat and lid
982Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
983Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
984a)White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
985Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
986Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
987Kitchen sink with drain board
988510x1040 mm bowl depth 250 mm
989Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
990Semi rigid pipe
99132 mm dia
992Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
993Providing and fixing PTMT Bottle Trap for Wash basin and sink
994Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms
995Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
996Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
997600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
998C.P. BRASS FITTINGS
999Providing and fixing unplasticised PVC connection pipe with brass unions
100045 cm length
100115 mm nominal bore
1002Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
100315 mm nominal bore
1004Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
100515 mm nominal bore
1006INTERNAL SOIL /WASTE PIPE LINE
1007Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
1008110mm
1009Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.
1010110 mm diameter
1011Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
1012Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
1013Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
1014Bend 87.5°
1015110 mm bend
1016Shoe (Plain)
1017110 mm Shoe
1018Providing and fixing of UPVC SWR pipe type -B confirming to IS -13592 including jointing the pipe with rubbing ring ,lubricant and UPVC SWR cupler confirming to IS -14735 ,ALSO Including excavation of trenches cutting of walls and holes and repairing the walls ,floors and refiling the trenches as before but excluding supply and cost of other fitting such as elbow bead ,tee and Y -tee including supply of all materials labour and t&p .Required for proper completion of the work .
1019a) 110mm dia P.V.C. pipe
1020b) 75mm dia P.V.C. pipe
1021Providing and fixing of UPVC SWR door bend confirming to IS-14735.
1022110MM
1023Providing and fixing of UPVC Nahani trap size 100/75mm ,100/90 mm confirming to IS -14735 self cleaning design fixed in pcc 1:2:4 and supply and fixing of 125mm dia heavt duty cp brass jali.
1024Providing and fixing of UPVC SWR cowl confirming to IS-14735.
1025110MM
1026Providing and fixing of UPVC Plain TEE confirming to IS-14735.
102775X75X75MM
1028110X110X110MM
1029Providing and fixing of UPVC SWR door y confirming to IS-14735.
1030110MM
1031INTERNAL WATER SUPPLY WORKS
1032Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.
1033Concealed work including cutting chases and making good the walls etc.
103415mm dia nominal outer dia pipes
103520mm dia nominal outer dia pipes
1036Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.
1037Internal work-Exposed on wall
103825mm dia nominal bore
103932mm dia nominal bore
1040Providing and fixing gun metal gate valve with wheel of approved quality.
104125mm dia nominal bore
104232mm dia nominal bore
1043Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license].
1044Capcity in Per Liters
1045Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete
104625 mm nominal bore
1047TYPE-V
1048DSR ELECTRICAL -2025
1049W I R I N G
1050Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
1051Group A
1052Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
1053Group C
1054Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
10552 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
10562 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
10572 X 4 sq. mm + 1 X 4 sq. mm earth wire
10582 X 6 sq. mm + 1 X 6 sq. mm earth wire
1059Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1060Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1061Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1062Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
1063Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
1064Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
1065Upto 450 mm sweep
1066Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copperconductor, unarmored telephone cable in the existingsurface/ recessed steel/ PVC conduit as required.
10671 Pair
1068Supplying and drawing co-axial TV cable RG-6 grade,0.7 mm solid copper conductor PE insulated, shieldedwith fine tinned copper braid and protected with PVCsheath in the existing surface/ recessed steel/ PVCconduit as required.
1069Supplying and fixing of following sizes of mediumclass PVC conduit along with accessories insurface/recess including cutting the wall and makinggood the same in case of recessed conduit asrequired.
107020 mm
1071Supplying and fixing metal box of following sizes(nominal size) on surface or in recess with suitablesize of phenolic laminated sheet cover in frontincluding painting etc. as required.
1072150 mm X 75 mm X 60 mm deep
1073Supplying and fixing following piano type switch/socket on the existing switch box/ cover includingconnections etc. as required.
1074Telephone socket outlet
1075TV antenna socket outlet
1076Bell push
1077Supplying and fixing following modular switch/ socketon the existing modular plate & switch box includingconnections but excluding modular plate etc. asrequired.
1078Telephone socket outlet
1079TV antenna socket outlet
1080Bell push
1081Supplying and fixing following size/ modules, GI boxalong with modular base & cover plate for modularswitches in recess etc. as required.
10824 Module (125mmX75mm)
1083Providing and fixing connecting and testing of telephone tag block in MS box with hinged and lockable cover duly painted over primer as required.
108410 /20 Pair
1085MCCB, MCB & DB'S
1086Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
10874 way (4 + 12), Double door
1088Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1089Single pole
1090Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
109125 amps
109240 amps
109363 amps
1094Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required
1095Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
1096E A R T H I N G
1097Earthing with G.I. earth plate 600 mm X 600 mm X 6mm thick including accessories, and providingmasonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 Meter long etc.with charcoal/ coke and salt as required.
1098Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
1099Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
1100Supply, Installation, Testing and Commissioning ofceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. metal( Aluminiumalloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessoriesincluding safety pin, nut bolts, washers, temperaturerise=75 0C (max.), insulation resistance more than 2mega ohm, suitable for 230 V, 50 Hz, single phase ACsupply, Ceiling Fan compliant to IS 374:2019 fan i/cexternal connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cableand earthing etc. as required.
11011200mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 210 CM/Min (Minimum)
1102Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of3.3 mm dia round headed screws, one lock at the corners. Clamp shallbe made of 12 mm dia M.S. bar bent to shape as per standard drawing.
1103Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cablerun shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
110416 sqmm 4 core
1105Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire
110616 sqmm 4 core
1107Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge.
110816 sqmm 4 core
1109Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only
1110Main L.T. Panel
1111Incoming :
1112100 Amp. MCCB-1 Nos.
1113Outgoing :
111463 Amp. MCCB-2 Nos.
1115Supply and fixing of danger board fabricated from 10 gauge M.S. sheet as per I.E.rules.
1116Supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting of tested quality.
1117Supply & fixing of Crimping, solder, less, copper ton electroplated lugs of Dowel/ismail make suitable for 1.5 sqmm to 6sqmm cables, including tapping with insulating tape, etc. complete in all respects.
1118LED Batten light (System lumen efficacy >135lm/Watt)
1119Powder coated die cast /Extruded aluminiumBody (Thickness > 1.20 mm)
112018- 22 Watt
1121MAKE:-HAVELLS;
1122Supply and fixing of LED light including connections etc. complete as required
112310-15 watt LED BULB
1124MAKE:-HAVELLS;
1125Supply and fixing of bracket light including connections etc. complete as required
112610-15 watt
1127MAKE:-HAVELLS;
1128Supply and erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required
1129Exhaust Fan
1130MAKE:-HAVELLS;
1131CANTEEN
1132BILL OF QUANTITY
1133UP TOPLINTH LVL
1134Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
1135All kinds of soil
1136Ground floor
1137Supply and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
1138Ground floor
1139Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
11401:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
1141Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment(excluding the cost of chemical emulsion) :
1142Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart.
1143Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in
1144Cement Mortar 1:6 (1 Cement : 6 Coarse sand)
1145Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
1146Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
1147RCC WORK UPTO PLINTH
1148providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland Slag cement, admixtures in recommended proportions as per iS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
1149All works upto plinth level
1150concrete of m25 grade with minimum cement content of 330 kg /cum
1151PLINTH BEAM
1152COLUMN
1153Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
1154Thermo-Mechanically Treated bars of grade Fe-500D or more.
1155UP TO plinth Lvl.
1156Centering and shuttering including strutting, propping etc. and removal of form for
1157Tie Beam
1158Column
115915 mm cement plaster of mix :
11601:4 (1 cement: 4coarse sand)
1161SUPER STRUCTURE
1162Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in
1163Cement Mortar 1:6 (1 Cement : 6 Coarse sand)
1164RCC WORK ABOVE PLINTH
1165providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland Slag cement, admixtures in recommended proportions as per iS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
1166All works Above plinth level
1167concrete of m25 grade with minimum cement content of 330 kg /cum
1168LINTEL BAND
1169COLUMN
1170Centering and shuttering including strutting, propping etc. and removal of form for
1171Column
1172Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
1173Thermo-Mechanically Treated bars of grade Fe-500D or more.
1174Above plinth Lvl.
1175WOOD WORK
1176Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
117735 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
1178Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of leadfree uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extrude dprofiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and designduly reinforced with galvanized mild steel section made of required shape & size as perCPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (whereever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fastenersof minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 gradesleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plasticcaps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required)shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, includingdrilling of holes for fixing hardware and drainage of water etc. After fixing frame the gapbetween frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conformingto CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcementand cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.
1179Three track three panels sliding window with two glazed & one wire mesh panels withAluminium channel for roller track, wool pile, nylon rollers with SS 304 body.
1180Using R3 series with frame (98mm & above) x (40mm & above) & both glazed and fly screensash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle onevery glazed panel along with multi-point locking system. (Height upto 1.8m).Window Upvc Frame
1181Providing and fixing fly proof Wiremesh , to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.
1182With 12 mm mild steel U beading
1183Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
1184Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
1185Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
1186Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :
11874.0 mm thick glass panes
1188Providing and fixing ISI marked S.S. sliding door bolts with nuts and screws etc. complete :
1189300x16 mm
1190Providing and fixing ISI marked S.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete
1191250x10 mm
1192Providing and fixing ISI marked .S.S. handles conforming to IS:4992 with necessary screws etc. complete :
1193125 mm
1194PLASTER WORK
119512 mm cement plaster of mix :
11961 : 6 (1 cement : 6 coarse sand)
119712 mm cement plaster of mix :
11981 : 6 (1 cement : 6 coarse sand)
1199FLOORING
1200Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
120125 mm thick
1202Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishingcomplete.
1203GROUND FLOOR
1204Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.
1205Granite stone slab of colour black, Cherry/Ruby red
1206Area of slab over 0.50 sqm
1207Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
1208Size of Tile 600x600 mm
1209FINISHING WORK
1210Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
1211Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
1212Steel work
1213Finishing walls with Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
1214Outer side
1215Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour all complete, as per manufacturer's specification.
1216New work ( two or more coats ) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre.
1217Inner wall surface
1218Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour all complete, as per manufacturer's specification.
1219New work ( two or more coats ) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre.
1220CEILING
1221Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
1222Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5
1223(1cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm heightincluding rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm ofcement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-incharge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand)admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the
1224With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
1225CANTEEN
1226INTERNAL SANITARY W/S INTALLATION WORKS
1227SANITARY INSTALLATIONS & FITTINGS
1228Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
1229a)White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
1230Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
1231Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
1232Kitchen sink with drain board
1233510x1040 mm bowl depth 250 mm
1234Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
1235Semi rigid pipe
123632 mm dia
1237Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
1238Providing and fixing PTMT Bottle Trap for Wash basin and sink
1239Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms
1240Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
1241Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
1242600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
1243C.P. BRASS FITTINGS
1244Providing and fixing unplasticised PVC connection pipe with brass unions
124545 cm length
124615 mm nominal bore
1247Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
124815 mm nominal bore
1249Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
125015 mm nominal bore
1251INTERNAL SOIL /WASTE PIPE LINE
1252Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
1253110mm
1254Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.
1255110 mm diameter
1256Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
1257Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
1258Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
1259Bend 87.5°
1260110 mm bend
1261Shoe (Plain)
1262110 mm Shoe
1263INTERNAL WATER SUPPLY WORKS
1264Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.
1265Concealed work including cutting chases and making good the walls etc.
126615mm dia nominal outer dia pipes
126720mm dia nominal outer dia pipes
1268Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.
1269Internal work-Exposed on wall
127025mm dia nominal bore
127132mm dia nominal bore
1272Providing and fixing gun metal gate valve with wheel of approved quality.
127325mm dia nominal bore
127432mm dia nominal bore
1275Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license].
1276Capcity in Per Liters
1277Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete
127825 mm nominal bore
1279GUARD ROOM -I
1280UP TO PLINTH LEVEL
1281Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
1282All kinds of soil
1283Excavating, supplying, stacking and filling of local earth (including royalty) by mechanicaltransport upto a lead of 5km also including ramming and watering of the earth in layers notexceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
1284Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
1285Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion)
1286Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:
1287With Chlorpyriphos/Lindane E.C. 20% with 1%concentration
1288Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
12891:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
1290Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
1291Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
1292providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland Slag cement, admixtures in recommended proportions as per iS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
1293All works upto plinth level
1294concrete of m25 grade with minimum cement content of 330 kg /cum
1295PLINTH BAND
1296COLUMN
1297Centering and shuttering including strutting, propping etc. and removal of form for
1298Lintels, beams, plinth beams, girders, bressumers and cantilevers
1299Foundations, footings, bases of columns, etc. for mass concrete
1300Columns, Pillars, Piers, Abutments, Posts and Struts
1301Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
1302Thermo-Mechanically Treated bars of grade Fe-500D or more.
1303Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in
1304Cement mortar 1:6 (1 cement : 6 coarse sand)
130515 mm cement plaster of mix :
13061:4 (1 cement: 4coarse sand)
1307Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
130840 mm thick with 20 mm nominal size stone aggregate RATE= 614.20/SQM
1309FOR 25 MM THICK
1310SUPER STRUCTURE
1311providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland Slag cement, admixtures in recommended proportions as per iS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
1312All works upto plinth level
1313concrete of m25 grade with minimum cement content of 330 kg /cum
1314LINTEL
1315COLUMN
1316Centering and shuttering including strutting, propping etc. and removal of form for
1317LINTEL
1318COLUMN
1319Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
1320Thermo-Mechanically Treated bars of grade Fe-500D or more.
1321Brick work with common burnt clay F.P.S. (non modular) bricks of class designation M-7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
1322Cement mortar 1:6 (1 cement : 6 coarse sand)
1323Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation7.5 in superstructure above plinth level up to floor V level.
1324Cement mortar 1:4 (1 cement :4 coarse sand)
1325Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
1326Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) Non-decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
132735 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
1328Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
132940x40x5
1330Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
1331Fixed to steel windows by welding
1332Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).
1333Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
1334Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :
13354.0 mm thick glass panes
133612 mm cement plaster of mix :
13371:6 (1 cement: 6 coarse sand)
133812 mm cement plaster of mix :
13391:6 (1 cement: 6 coarse sand)
1340Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
134140 mm thick with 20 mm nominal size stone aggregate
1342Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.
134318 mm thick
1344Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
1345Ground floor
1346Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shadecomplete.
1347Ground floor
1348Finishing walls with Acrylic Smooth exterior paint of required shade :
1349New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
1350Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :
1351New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
1352Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
1353Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
1354Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
1355Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
1356Providing and fixing Oxidized sliding door bolts, ISI marked to required colour or shade, with nuts and screws etc. complete
1357300x16 mm
1358Providing and fixing Oxidized handles, ISI marked, required colour or shade, with necessary screws etc. complete
1359125 mm
1360Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm heightincluding rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm ofcement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-incharge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand)admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the
1361(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. * All above operations to be done in order and as directed and specified by the Engineer-In-charge:
1362With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
1363Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
1364110mm (Rainwater+soil+waste)
1365Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
1366110 mm diameter
1367Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
1368Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
1369Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
1370Bend 87.5°
1371110 mm bend
1372Shoe (Plain)
1373110 mm Shoe
1374GUARD ROOM -I
1375INTERNAL SANITARY W/S INTALLATION WORKS
1376SANITARY INSTALLATIONS & FITTINGS
1377Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
1378White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
1379Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
1380a)White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
1381Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
1382Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
1383Semi rigid pipe
138432 mm dia
1385Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
1386Providing and fixing PTMT Bottle Trap for Wash basin and sink
1387Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms
1388Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
1389Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
1390600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
1391C.P. BRASS FITTINGS
1392Providing and fixing unplasticised PVC connection pipe with brass unions
139345 cm length
139415 mm nominal bore
1395Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
139615 mm nominal bore
1397Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
139815 mm nominal bore
1399INTERNAL SOIL /WASTE PIPE LINE
1400Providing and fixing of UPVC SWR pipe type -B confirming to IS -13592 including jointing the pipe with rubbing ring ,lubricant and UPVC SWR cupler confirming to IS -14735 ,ALSO Including excavation of trenches cutting of walls and holes and repairing the walls ,floors and refiling the trenches as before but excluding supply and cost of other fitting such as elbow bead ,tee and Y -tee including supply of all materials labour and t&p .Required for proper completion of the work .
1401a) 110mm dia P.V.C. pipe
1402b) 75mm dia P.V.C. pipe
1403Providing and fixing of UPVC SWR door bend confirming to IS-14735.
1404110MM
1405Providing and fixing of UPVC Nahani trap size 100/75mm ,100/90 mm confirming to IS -14735 self cleaning design fixed in pcc 1:2:4 and supply and fixing of 125mm dia heavt duty cp brass jali.
1406Providing and fixing of UPVC SWR cowl confirming to IS-14735.
1407110MM
1408Providing and fixing of UPVC Plain TEE confirming to IS-14735.
140975X75X75MM
1410110X110X110MM
1411INTERNAL WATER SUPPLY WORKS
1412Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.
1413Concealed work including cutting chases and making good the walls etc.
141415mm dia nominal outer dia pipes
141520mm dia nominal outer dia pipes
1416Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.
1417Internal work-Exposed on wall
141825mm dia nominal bore
141932mm dia nominal bore
1420Providing and fixing gun metal gate valve with wheel of approved quality.
142125mm dia nominal bore
142232mm dia nominal bore
1423Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license].
1424Capcity in Per Liters
1425Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete
142625 mm nominal bore
1427GUARD ROOM -I
1428W I R I N G
1429Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
1430Group C
1431Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
14322 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
14332 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1434Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1435Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1436Supply and fixing of LED light including connections etc. complete as required
143710 to 15 Watt LED Bulb
1438Cat. AAA
1439Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374 -2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
14401200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
1441ALUMINIUM CABLE
1442Laying of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade offollowing size direct in ground including excavation,sand cushioning, protective covering and refilling thetrench etc as required.
1443Above 35 sq. mm and upto 95 sq. mm
1444Supply a of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cablerun shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
144510sqmm 4.0 core
1446Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket,bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in theexisting trench, complete as required.
144763 mm dia (OD-63 mm & ID-51 mm nominal)
1448Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge.
144910sqmm 4.0 core
1450GUARD ROOM
1451Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches.
1452Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated orstacked materials.
1453All kinds of soil
1454Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
1455Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
14561:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
1457Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. (5 miles) from the site of work and including watering, ramming, dressing etc rate to include cost of all materials, labour and T & P etc required for proper completion of the work.
1458Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm
1459(4) Treatment junction of wall and the floor 7.5 liters /sqm (5)Treatment of soil along external perimeter of building 7.5 liters/sqm. (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution)
1460providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland Slag cement, admixtures in recommended proportions as per iS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
1461All works upto plinth level
1462concrete of m25 grade with minimum cement content of 330 kg /cum
1463PLINTH BAND
1464COLUMN
1465providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland Slag cement, admixtures in recommended proportions as per iS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
1466All works Above plinth level
1467concrete of m25 grade with minimum cement content of 330 kg /cum
1468LINTEL
1469COLUMN
1470M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work.
1471Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size).
1472Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
1473Brick work in super-structure above plinth level up to floor two level (up to two storeys) including necessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall 230mm thick to (1:6 cement & coarse sand).
1474Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
1475P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
147615 mm cement plaster on plinth of mix : 1:4 (1 cement: 4 coarse sand).
147715 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand.
147812mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1) 1 cement : 6coarse sand.
1479Forming groove of uniform size from 12x12 mm and upto 25x15 mm in the top layer of washed stone grit plastered surface as per approved pattern, including providing and fixing aluminum channels of appropriate size and thickness (not less than 2 mm), nailed to the under layer with rust proof screws and nails and finishing the groove complete as per specifications and direction of the Engineer-in-Charge.
148040mm thick 1:2:4 plain cement concrete floor (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement.
1481Providing & fixing ISI marked flush door shutters conforming IS: 2202 non- decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters (a) 35mm thick including ISI marked stainless steel butt hinges with necessary screws.
1482(a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
1483(a) Single leaf
1484Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
148540x40x5
1486Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).
1487Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
1488Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes
1489Fixing of Door, windows / ventilators chaukhats in position.
1490(a) Door chaukhats
1491(b) Window chaukhats
1492Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm
1493Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :
1494Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm
1495Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
1496Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre. (Ceiling & inner)
1497Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm)
1498Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
1499Providing & laying \\"brick bat Coba\\" 100 mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrylic cement concrete water proofing compound filled gaps of
1500coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono lythic plaster wall upto 30cm higher and junction and corner shall be rounded by brick
1501ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour T & P etc complete for proper completion of work.
1502Centering and shuttering including strutting, propping etc. and removal of form for all heights :
1503TIE BEAM/PLINTH BEAM
1504LINTEL BAND
1505Column
1506Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.
1507110 mm diameter
1508Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
1509GUARD ROOM
1510W I R I N G
1511Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
1512Group C
1513Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
15142 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
15152 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1516Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1517Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1518LED LUMINAIRES
1519Supply and fixing of LED light including connections etc. complete as required
152010 to 15 Watt LED Bulb
1521Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374 -2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
15221200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
1523PUMP ROOM
1524Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches.
1525Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
1526Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
15271:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
1528Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. (5 miles) from the site of work and including watering, ramming, dressing etc rate to include cost of all materials, labour and T & P etc required for proper completion of the work.
1529Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm
1530(4) Treatment junction of wall and the floor 7.5 liters /sqm (5)Treatment of soil along external perimeter of building 7.5 liters/sqm. (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution)
1531providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland Slag cement, admixtures in recommended proportions as per iS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
1532All works upto plinth level
1533concrete of m25 grade with minimum cement content of 330 kg /cum
1534PLINTH BAND
1535COLUMN
1536providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland Slag cement, admixtures in recommended proportions as per iS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
1537All works Above plinth level
1538concrete of m25 grade with minimum cement content of 330 kg /cum
1539LINTEL
1540COLUMN
1541M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work.
1542Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size).
1543Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
1544Brick work in super-structure above plinth level up to floor two level (up to two storeys) including necessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall 230mm thick to (1:6 cement & coarse sand).
1545Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
1546P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
154715 mm cement plaster on plinth of mix : 1:4 (1 cement: 4 coarse sand).
154815 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand.
154912mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1) 1 cement : 6coarse sand.
1550Forming groove of uniform size from 12x12 mm and upto 25x15 mm in the top layer of washed stone grit plastered surface as per approved pattern, including providing and fixing aluminum channels of appropriate size and thickness (not less than 2 mm), nailed to the under layer with rust proof screws and nails and finishing the groove complete as per specifications and direction of the Engineer-in-Charge.
155140mm thick 1:2:4 plain cement concrete floor (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement.
1552Providing & fixing ISI marked flush door shutters conforming IS: 2202 non- decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters (a) 35mm thick including ISI marked stainless steel butt hinges with necessary screws.
1553(a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
1554(a) Single leaf
1555Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
155640x40x5
1557Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).
1558Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
1559Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes
1560Fixing of Door, windows / ventilators chaukhats in position.
1561(a) Door chaukhats
1562(b) Window chaukhats
1563Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm
1564Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :
1565Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm
1566Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
1567Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre. (Ceiling & inner)
1568Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm)
1569Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
1570Providing & laying \\"brick bat Coba\\" 100 mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrylic cement concrete water proofing compound filled gaps of
1571coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono lythic plaster wall upto 30cm higher and junction and corner shall be rounded by brick
1572ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour T & P etc complete for proper completion of work.
1573Centering and shuttering including strutting, propping etc. and removal of form for all heights :
1574(a) Foundations, footings, bases of columns, etc. for mass concrete
1575(b) Suspended floors, roofs, landings, balconies and access platform
1576(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers
1577(d) Columns, Pillars, Piers, Abutments, Posts and Struts
1578Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.
1579110 mm diameter
1580Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
1581PUMP ROOM
1582W I R I N G
1583Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
1584Group C
1585Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
15862 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
15872 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1588Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1589Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1590MCCB, MCB & DB'S
1591Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
15924 way (4 + 12), Double door
1593Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1594Single pole
1595Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
159663 amps
1597E A R T H I N G
1598Earthing with G.I. earth plate 600 mm X 600 mm X 6mm thick including accessories, and providingmasonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 Meter long etc.with charcoal/ coke and salt as required.
1599Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
1600Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
1601LED LUMINAIRES
1602Supply and fixing of LED light including connections etc. complete as required
160310 to 15 Watt LED Bulb
1604ALUMINIUM CABLE
1605Laying of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade offollowing size direct in ground including excavation,sand cushioning, protective covering and refilling thetrench etc as required.
1606Above 35 sq. mm and upto 95 sq. mm
1607Supply a of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cablerun shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
160810sqmm 4.0 core
1609Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket,bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in theexisting trench, complete as required.
161063 mm dia (OD-63 mm & ID-51 mm nominal)
1611Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge.
161210sqmm 4.0 core
161310sqmm 4.0 core
1614ELECTRICAL ROOM
1615Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
1616All kinds of soil
1617Carted earth filling under floor By Mechanical Transport including loading, unloading and stacking earth lead up to 2.5 km.Including cost of earth and Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.including cost of earth
1618Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
1619Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion)
1620Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:
1621With Chlorpyriphos/Lindane E.C. 20% with 1%concentration
1622Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
16231:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
1624Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived fromnatural sources)
1625Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
1626providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland Slag cement, admixtures in recommended proportions as per iS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
1627All works upto plinth level
1628concrete of m25 grade with minimum cement content of 330 kg /cum
1629TIE BEAM / PLINTH BEAM
1630COLUMN
1631Centering and shuttering including strutting, propping etc. and removal of form for
1632TIE BEAM / PLINTH BEAM
1633Column
1634Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
1635Thermo-Mechanically Treated bars of grade Fe-500D or more.
1636Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in
1637Cement mortar 1:6 (1 cement : 6 coarse sand)
163815 mm cement plaster of mix :
16391:4 (1 cement: 4coarse sand)
1640Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
164140 mm thick with 20 mm nominal size stone aggregate
1642providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland Slag cement, admixtures in recommended proportions as per iS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
1643All works Above plinth level
1644concrete of m25 grade with minimum cement content of 330 kg /cum
1645LINTEL
1646COLUMN
1647Centering and shuttering including strutting, propping etc. and removal of form for
1648LINTEL
1649COLUMN
1650Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
1651Thermo-Mechanically Treated bars of grade Fe-500D or more.
1652Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
1653Cement mortar 1:4 (1 cement : 4 coarse sand)
1654Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
1655Cement mortar 1:4 (1 cement :4 coarse sand)
1656Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
1657Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) Non-decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
165835 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
1659Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
166040x40x5
1661Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
1662Fixed to steel windows by welding
1663Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).
1664Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
1665Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :
16664.0 mm thick glass panes
166712 mm cement plaster of mix :
16681:6 (1 cement: 6 coarse sand)
166912 mm cement plaster of mix :
16701:6 (1 cement: 6 coarse sand)
1671Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
167240 mm thick with 20 mm nominal size stone aggregate
1673Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.
167418 mm thick
1675Finishing walls with Acrylic Smooth exterior paint of required shade :
1676New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
1677Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :
1678New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
1679Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
1680Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
1681Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
1682Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
1683Providing and fixing Oxidized sliding door bolts, ISI marked to required colour or shade, with nuts and screws etc. complete
1684300x16 mm
1685Providing and fixing Oxidized handles, ISI marked, required colour or shade, with necessary screws etc. complete
1686125 mm
1687Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm heightincluding rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm ofcement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-incharge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand)admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the
1688(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. * All above operations to be done in order and as directed and specified by the Engineer-In-charge:
1689With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
1690Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
1691110mm (Rainwater+soil+waste)
1692Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
1693110 mm diameter
1694Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
1695Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
1696Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
1697Bend 87.5°
1698110 mm bend
1699Shoe (Plain)
1700110 mm Shoe
1701ELECTRICAL ROOM
1702Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
1703Group C
1704Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
17052 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
17062 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
17072 X 4 sq. mm + 1 X 4 sq. mm earth wire
17084 X 16 sq. mm + 2 X 16 sq. mm earth wire
1709Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1710Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1711E A R T H I N G
1712Earthing with G.I. earth plate 600 mm X 600 mm X 6mm thick including accessories, and providingmasonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 Meter long etc.with charcoal/ coke and salt as required.
1713Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
1714Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
1715Supply and fixing of LED light including connections etc. complete as required
171610 to 15 Watt LED Bulb
1717Cat. AAA
1718BIKE & CYCLE STAND
1719Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
1720All kinds of soil
1721Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
1722Ground floor
1723Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
17241:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
1725Supply and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
1726Ground floor
1727providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland Slag cement, admixtures in recommended proportions as per iS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
1728All works upto plinth level
1729concrete of m25 grade with minimum cement content of 330 kg /cum
1730Raft Foundation
1731Column
1732Grade Beam
1733Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
1734Thermo-Mechanically Treated bars of grade Fe-500D or more.
1735UP TO plinth Lvl.
1736FORM WORK
1737Centering and shuttering including strutting, propping etc. and removalof form for
1738Foundations, footings, bases of columns, etc. for mass concrete
1739Columns, Pillars, Piers, Abutments, Posts and Struts
1740Beams, plinth beams, girders, bressumers and cantilevers
1741Steel work in built up tublar trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer,elded and bolted including special shapped washers etc. complete:(a) Electric resistance or inductionbutt welded tubes.
1742Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shapewherever required.
1743Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal sizelaid in one layer neat cement, including cement slurry, but excluding the cost of nosing of step etc.
174440 mm thick with 20 mm nominal size stone aggregate
1745Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
1746Steel work
1747WET RISER /DOWN COMER SYSTEM
1748Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required
1749150 mm dia
1750100 mm dia
1751Supplying and fixingfirst aid HoseReel with MS construction spray painted n postofficered,conformingtoIS884completewiththefollowingasrequired.20mm nominal internal dia water hose thermoplastic(Textile reinforced) type -2 as per IS: 1258520mm nominal internal dia gunmetal globe valve&nozzle.Drum and brackets for fixing the equipmets on wall.Connections fromriser with 25mm dia stop gunmetal valve & M.S. Pipe and socket
1752Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required
1753Single headed Stainless steel
1754Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required
1755Gun Metal
1756Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required
1757Stainless Steel (Grade 304)
1758Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required
1759150 mm dia
1760Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required
1761100mm dia
1762150mm dia
1763Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required
1764150 mm dia
1765Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shadeas required.
1766Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)
1767Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520
1768Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.
1769M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered
1770900 lpm at 35 m Head
1771Providing & fixing of FHC(NewAge Fire Hose Cabinet (Double door) (FRP) Including cost of materials and labour etc complete .Excluding cost of pipe .
1772Providing&fixing of Terrace motor covering Including cost of M.S.angle and profile sheet materials and labour etc complete .
1773PVC TANK AND MOTOR FIXING FOUNDATION
1774ELECTRICAL WORK
1775Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cablerun shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
177610 sq. mm 4 core
1777INTELLIGENT FIRE ALARM SYSTEM
1778Supplying, installation, testing & commissioning ofaddressable manual call point complete as required.
1779Supplying, installation, testing & commissioning of intelligentaddressable programmable sounder complete as required.
1780Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit asrequired.
178120 mm
178225 mm
178332 mm
178450 mm
1785Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
1786Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.
1787speaker cable Single pair, 2-core, 1.5 sqmm
1788Supplying, installation, testing & commissioning of centralgraphical fire alarm management system to centrally monitorand operate the fire alarm system complete as required.
17894 Zone
1790Supplying, installation, testing and commissioning of microprocessor based intelligent addressable main fire alarmpanel, central processing unit with the following loopmodules and capable of supporting not less than 240devices (including detectors) and minimum 120 detectors perloop and loop length up to 2 km, network communicationcard, minimum 320 character graphics/ LCD display withtouch screen or other keypad and minimum 4000 eventshistory log in the non volatile memory (EPROM), powersupply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 voltsealed maintenance free batteries with automatic charger
1791The panel shall have facility to connect printer to printout logand facility to have seamless integration with analog/digitalvoice evacuation system (which is part of the schedule ofwork under SH: PA System) and shall be complete with allaccessories . The panel shall be compatible for IBMS systemwith open protocol BACnet/ Modbus over IP complete as perspecifications.
1792Ten Loop Panel.
1793Supplying, installation, testing & commissioning of repeaterpanel with 320 character/ Touch screen LCD display withinbuilt reset, acknowledge and silence switches complete asrequired.
1794Supplying, installation, testing & commissioning of faultisolator complete with base as required.
1795Supplying, installation, testing & commissioning of intelligentinterface unit BACnet/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required.
1796Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
17972 X 2.5 sq. mm
1798FIRE EXTINGUISHER
1799Supply and fixing of fire extinguiser ,ABC Type 4.0 kg capacity (ISI Marked IS : 15683 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work
1800Supply and fixing of fire extinguiser ,CO2 Type 4.5 kg capacity (ISI Marked IS : 2878 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work.
1801Supply and fixing of fire bucket 9-11 litres capacity with river sand fill supply of all materials and labour for proper completion of work.
1802FIRE SIGNAGE
1803Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
18042 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1805Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1806Supply and fixing of Acrylic Emergency EXIT Sign Board with LED Lights and Battery Backup complete in all respects
1807UGR (100 KL)
1808UP TO PLINTH LEVEL
1809Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
1810All kinds of soil
1811Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
1812All kinds of soil
1813Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
1814All kinds of soil
1815Supply and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
1816Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
18171:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size)
1818Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cementconcrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping ofconcrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing andreinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.In case the cement content in design mix is more than 110% of the specified minimum cement content, thecontractor shall have discretion to either re-design the mix or bear the cost of extra cement.
1819Concrete of M30 grade with minimum cement content of 350 kg /cum
1820UP TO PLINTH
1821Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
1822Thermo-Mechanically Treated bars of grade Fe-500D or more.
1823Centering and shuttering including strutting, propping etc. and removal of form for
1824RETAINING WALL
1825Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
1826Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
1827All kinds of soil
1828Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
1829Ground floor
1830Supply and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
1831Ground floor
1832Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
18331:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
1834Providing and laying in position machine battched and machine mixed design mix M- 25 grade cement concrete for RCC work using cement content as per approved design mix. Including pumping of concrete to site of laying but including the cost of centreing, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impaaining strenght and durability as per direction of Engineer - In - Charge
1835All works upto plinth level
1836Footing
1837column
1838Grade beam
1839Plinth Band
1840All works Above plinth level
1841column
1842Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
1843Thermo-Mechanically Treated bars of grade Fe-500D or more.
1844Centering and shuttering including strutting, propping etc. and removal of form for
1845UPTO PLINTH
1846Foundations, footings, bases of columns, etc. for mass concrete
1847Columns, Pillars, Piers, Abutments, Posts and Struts
1848Lintels, beams, plinth beams, girders, bressumers and cantilevers
1849Lintels, beams, plinth beams, girders, bressumers and cantilevers
1850ABOVE PLINTH
1851Columns, Pillars, Piers, Abutments, Posts and Struts
1852Lintels, beams, plinth beams, girders, bressumers and cantilevers
1853Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
1854Cement mortar 1:6 (1 cement : 6 coarse sand)
1855Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in Superstructure above plinth level up to floor V level in all shapes and sizes in :
1856Cement Mortar 1:4 (1 Cement : 4 Coarse sand 2.25FM
1857GROUND FLOOR
1858Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the costof nosing of steps etc. complete.
185940 mm thick with 20 mm nominal size stone aggregate
1860Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
186125 mm thick
186212 mm cement plaster of mix :
18631 : 6 (1 cement : 6 coarse sand)
1864Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.25 ltr/10 sqm over and including priming coat of exterior primer applied @.75 LTR/10 sqm)
1865Painting with synthetic enamel paint or approved band and manufacture of required colour to give an even shade.
1866Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
1867Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
1868Hot finished seamless type tubes
1869Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (basemetal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on bothside of the sheet and polyester top coat 15-18 microns. Sheet should have protective guardfilm of 25 microns minimum to avoid scratches during transportation and should be suppliedin single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixedusing self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete uptoany pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters andtrusses and including cutting to size and shape wherever required.
1870Thermal Insulation of roofing with Expanded polystyrene fixed with suitable adhesive to the false ceiling as per the directions of the Engineer-in-charge: With Type N - Normal 50 mm thick
1871Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete (Ridges plain (500 - 600mm)
1872Providing and laying 80 mm thick faciory made cement concrete interlocking paver block of M -35 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compactedbed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
1873Construction of granular sub-base by providing close graded Materialconforming to specifications, mixing in a mechanical mix plant at OMC,carriage of mixed material by tippers to work site. for all leads & lifts.spreading in uniform layers of specified thickness with motor grader onprepared surface and compacting with vibratory power roller to achieve thedesired density, complete as per specifications and directions of Engineer-in-charge
1874ASSEMBLY HALL
1875W I R I N G
1876Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
1877Group C
1878Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
18792 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1880Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1881Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1882Supply and fixing of Tubelight including connections etc. complete as required
18831x22 watt
1884Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374 -2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
18851200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
1886MCCB, MCB & DB'S
1887Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
18884 way (4 + 12), Double door
1889Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1890Single pole
1891Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. asrequired.
1892Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. asrequired
1893Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
1894ALUMINIUM CABLE
1895Laying of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade offollowing size direct in ground including excavation,sand cushioning, protective covering and refilling thetrench etc as required.
1896Above 35 sq. mm and upto 95 sq. mm
1897Supply a of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cablerun shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
189835 sq. mm 3-1/2 core
1899Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket,bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in theexisting trench, complete as required.
190063 mm dia (OD-63 mm & ID-51 mm nominal)
1901Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire
190235 sq. mm 3-1/2 core
1903Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge.
190435 sq. mm 3-1/2 core
1905ASSEMBLY HALL
1906P.A.SYSTEM
1907PUBLIC ADDRESS SYSTEM
1908Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete asrequired.
1909Supplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 volt AC supply complete as required.
1910Supplying, installation, testing & commissioning of exit point directional sound speaker with voice and integral audio amplifier with selectable sound pulse patterns complete as required.
1911Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assemblycomplete as required.
1912Supplying, installation, testing & commissioning of Podium assembly complete as required.
1913ELECTRICAL WORK
1914Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cablerun shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
191510 sq. mm 4 core
1916SOLAR
1917Supplying Installation, Testing and Commissioning ofon-grid Solar Photovoltaic Power Plant conforming tovarious applicable standards BIS, IEC, MNREguidelines, the Central Electricity AuthorityRegulations and CPWD Specifications as amended upto date, consisting of Mono/Poly Crystalline siliconsolar cells module, net metering facility, necessarycontrol, protections, earthing, cabling, mountingstructure, junction boxes, power conditioning units,Real time online web interfaced Data MonitoringSystem, Distribution panels, grid connectingarrangement, conduits, pipes, cable trays and otheraccessories etc. as required.a) High Energy Efficiency Solar Photovoltaic Module ofcapacity 330 Wp or above, manufactured in India,conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar PhotovoltaicModule conversion efficiency shall not be less than23% at STC with temperature coefficient of Pmaxbetter than -0.30% per 0C. PV modules used in solarpower plants/ systems must be warranted for theiroutput peak watt capacity, which should not be lessthan 90% at the end of 10 years and 80% at the end of25 years. Solar Modules shall be designed to operatein relative humidity upto 100% with temperaturebetween -10 0C and +85 0C. Further, each PV moduleused in any solar power project must have Radiofrequency identification tag with information such asname of manufacturer, month and year ofmanufacturing, country of origin (separately for Solarcell and module), I-V curve, Unique Serial No andModel No of the module, Wattage, Im, Vm and FF,name of test lab issuing IEC certificate.
1918b)Power Conditioning Unit (PCU) of 350-800 V DCInput voltage range and 415 V AC, three phase, 4wire, 50Hz +/- 2.5 Hz, output voltage suitable togenerate AC with a variation of 10% at nominalvoltage. Power with efficiency not less than 97%, totalharmonic distortion less than 3% and suitable forambient temperature from 0 to 50 0C, Minimum IP-65for outdoor and Minimum IP 21 for indoor, Built-in
1919meter and data logger, MPPT, switching devicesIGBT/MOSFETs and controller Microprocessor /DSP.PCU/inverter shall be capable of complete automaticoperation including wake-up, synchronization &shutdown. The PCU shall be able to withstandunbalanced load conforming to IEC standard withshutdown/standby mode. It must be provided with gridislanding along with manual disconnect pole isolationswitch besides automatic disconnection. Minimumprotections: Mains Under / Over Voltage, Over current,Over/Under grid frequency, Over temperature, Surgevoltage induced at output due to external source,Short-circuit, Lightening, Anti Islanding (for grid synch.Mode) and other protections as per applicablestandards. LCD/LED display of minimum parameters:DC input voltage, DC current, AC Voltage and current(all 3 phases, in case of 3 phase), Instantaneous &cumulative AC output power, Daily DC energyproduced and other parameters applicable standard.Communication interface RS 485 / RS 232.
1920c) Module mounting structure: The roof top solar plantgeneration units shall be installed by using supportingAluminium/Galvanized MS structure (mass of zinccoating shall be as per IS4759 ) having minimum headroom clearance of 2.4 meter above the terrace level /ground level. The mounting structure would bedesigned to sustain wind load and seismic parameterof the site of installation. All the structure shall bedesign as per applicable BIS code and the materialshall also confirm the applicable BIS Code. Structuralmaterial shall be corrosion resistant and electrolyticallycompatible with the materials used in the moduleframe, its fasteners, nuts and bolts. The suitablearrangements for maintenance and cleaning shall beprovided.d) Real time online web interfaced Data MonitoringSystem complete with accessories for variousparameters such as Solar Irradiance, temperature, ACOutput Voltage and current, Output Power, Powerfactor, DC Input Voltage and Current, Time Active,Time disabled, Time Idle, Power produced and otherparameters as per standard practices.e) Array junction box & Main junction box with IP 65protection and termination arrangement for incomingand outgoing cable along with glands, lugs and other
1921accessories etc. as required. Each junction box shallbe made of GRP/FRP/Powder Coated Aluminium /castaluminium alloy with full dust, water & vermin proofarrangement with High quality Suitable capacity MetalOxide Varistors(MOVs) (semiconductor diode withresistant applied voltage)/ surge arrestors and suitableReverse Blocking Diodes, isolation switches isolatethe DC input to Inverter, copper bus bar etc.
1922f) Lightning, surge voltage protection, earthingprotection and grid islanding.
1923g) Cables: Connections & Interconnections byrequired size IR/UV protected XLPE insulated copperconductor 1.1 kV grade armored power and controlcables(ISI Marked) along with supplying & fixing ofnecessary channel/conduit, GI cable trays, supports,lugs, thimble and other accessories etc. as required
1924h) DC Distribution Board And AC Distribution PanelBoard: IP65, free standing, metal cladded, havingcopper bus bar, having required protection and controlgears, connection-interconnection, etc. as required
1925CABLES
1926Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METALpipe as required.
1927Up to 35 sq. mm
1928Supply of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade .
192970sqmm 3.5 core
1930Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part IIcomplete with fitting and cutting, jointing etc. in the existing trench, complete as required.
193163 mm dia (OD-63 mm & ID-51 mm nominal)
1932Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge.
19333½ X 70 sq. mm (38mm)
1934INVERTER 3 PHASE (DC TO AC)
1935external sewage pipe line
1936Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required,
1937in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m.
1938a) Pipes 80mm to 300mm diameter.
1939Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
1940160 mm dia (OD-160 mm & ID-135 mm nominal)
1941200 mm dia (OD-200 mm & ID-175 mm nominal)
1942250 mm dia (OD-200 mm & ID-175 mm nominal)
1943Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design.
1944150mm diameter
1945200mm diameter
1946250mm diameter
1947Constructing brick masonry manhole with 75 class designation F.P.S. bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4graded stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix
1948(1 cement :4 coarse sand: 8 graded stone aggregate 40mm nominal size) inside plasstering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4
1949(1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design.
1950a) Inside size 90x80 cm & 45cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 Kg.
1951b) Extra for depth of man hole size 90x80 cm
1952Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design.
1953Providing and fixing square-mouth S.W. gully trap class SP-1 completewith C.I. grating brick masonry chamber with water tight C.I. coverwith frame of 300 x300 mm size (inside) the weight of cover to be notless than 4.50 kg and frame to be not less than 2.70 kg as perstandard design :
1954Constructing brick masonry chamber for underground C.I. inspection chamber and bendswith bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty)455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg(weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement: 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floatingcoat of neat cement on walls and bed concrete etc. complete as per standard design:
1955Inside dimensions 455x610 mm and 45 cm deep for single pipe line :
1956With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1957SEPTIC TANK
1958COST FOR SEPTIC TANK (MAIN BUILDING ) 100 USERS
1959COST FOR SEPTIC TANK (RESIDENTIAL BUILDING ) 100 USERS
1960COST FOR SEPTIC TANK (GUARD ROOM AND TYPE-V BUILDING ) 25 USERS
1961EXTERNAL WATER SUPPLY
1962Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required,
1963in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m.
1964a) Pipes 80mm to 300mm diameter.
1965Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stabilityfor hot & cold water supply including all CPVC plain & brass threaded fittings This includesjointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testingof joints complete as per direction of Engineer in Charge.
196680mm nominal bore.
196765 mm nominal dia Pipes
196850mm nominal bore.
196932 mm dia nominal bore
1970Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
19711:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
1972Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc.
197332mm nominal bore
1974Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4(1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:1.5:3mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size ) , includingnecessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stoneaggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as perstandard design :
1975With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
1976Supply and installation of Submirssible mono block pump in ugr for supply buildings.
197780mm dia outlet 5hp
197850mm dia outlet 3hp
197932mm dia outlet 1hp
1980PART A- TUBEBELL
1981Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.
1982All types of soil
1983400 mm dia
1984Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depthbelow ground level.
1985400 mm dia
1986Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge.
1987200 mm nominal size dia having minimum wall thickness 5.40 mm (Casing pipe )
1988150 mm nominal size dia having minimum wall thickness 5.00 mm (Lowring )
1989Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per directionof Engineer -in-charge..
1990150 mm nominal size dia (Slotted)
1991Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sandcontent (beyond permissible limit), with required capacity air compressor,running the compressor for required time till well is fully developed,measuring yield of well by “V” notch method or any other approved method,measuring static level & draw down etc. by step draw down method,collecting water samples & getting tested in approved laboratory, i/cdisinfection of tubewell, all complete, including hire & labour charges ofair compressor, tools & accessories etc., all as per requirement anddirection of Engineer-in-charge.
1992Providing and fixing suitable size threaded mild steel cap or spot weldedplate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:
1993200 mm nominal size dia
1994Providing and fixing M.S. clamp of required dia to the top of casing/housingpipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts f required size complete.
1995200 mm nominal size dia
1996Providing and fixing Bail plug/ Bottom plug of required dia to the bottomof pipe assembly of tubewell as per IS:2800 (part I).
1997200mm nominal size dia
1998Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work
199980 mm dia nominal bore
2000Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :
2001125 mm
2002100 mm
2003Supply and fixing of KSB Make 5 hp Submirssible pump.
2004Supply and fixing of nylon jali around the slotted pipes complete as required. Up to 30 meter
2005Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete asper direction of Engineer-in-charge.
20063.14*(.200*.200-.100*.100)*60
20073.14*(.200*.200-.075*.075)*90
2008Supplying,and fixing of AIR Compressor and clorinator system all complete as per direction of Engineer -in-charge.(For pump room clorinator)
2009Lab water Testing
2010Supply of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade . 10sqmm 4.0 core
2011CABLES
2012Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
2013Up to 35 sq. mm
2014Supply of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade .
201510sqmm 2.0 core
201610sqmm 4.0 core
201716sqmm 4.0 core
2018Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part IIcomplete with fitting and cutting, jointing etc. in the existing trench, complete as required.
201963 mm dia (OD-63 mm & ID-51 mm nominal)
2020Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge.
202110sqmm 2.0 core
202210sqmm 4.0 core
202316sqmm 4.0 core
2024Supplying, Installation, Testing and commissioning ofAstronomical time switch of following configuration tobe mounted in feeder pillars / Lighting DBs forautomatic switching On & OFF of street lights at sunset & sun rise or twilight(Auto ON, Auto OFF, Automodes) with manual override facility with 12/24 hourdisplay format with suitable battery and indication forrelay status i/c programming at site complete asrequired.Including foundation complete.
20253 output(1output per phase) and suitable for threephase supply
2026EXTERNAL FEEDER PANEL -100AMP
2027EXTERNAL STREET LIGHTING AND POLE WORK
2028Supply & fixing of 9 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect.
2029Supply & fixing of 9 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with Double arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect.
2030Supplying and drawing following sizes of FRLS/HFFRPVC insulated copper conductor, single core cable inthe existing surface/ recessed steel/ PVC conduit asrequired.
20312 x 1.5 sq. mm
2032LED Street light fixture, powder coated pressuredie cast aluminium body (System lumen efficacy≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioningof Street light LED fixture powder coatedpressure die cast aluminium body with driver asper the requirement with Driver efficiency >85%,Input voltage: 140-270 Volt AC, frequency 50/60 hz,Operating temp range -5 0C to 50 0C, internal surgeprotection of 5 KV L,N,E as per IEC 61000-4-5,Driver efficiency >85%,THD < 10% as per IEC
2033ENDURASUNDOWNNXTHOSL45WLEDCWPASBOPC (45W LED STREETLIGHT) (Make-havells)
2034Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
2035HIGHMAST LIGHTING FOR GROUND
2036Supply & fixing of 12.5 mtr High mast shaft of approvedmake with rising system hot dip glavanized inside & outside dip,heaving pole sheet thickness 3 mm. Top diaminium 150 mm, Bottom dia 310 mm base plate 25 mmthick suitable for wind velocity as per IS 875 part 3 &having no circumferential weld, with accessories forhigh mast such as head frame suitable for 6 luminaries &its control gear boxes 0.75 HP power tool moter, 3 pointsuspension system with steel wire rope 6 mm dia, doubledrum winch, including making suitable foundation asper manufature drawing/ site reuiment along withfoundation bolts nuts, washers, anchor plates etccompletee in all respect.
2037INCLUDING FOUNDATION
2038Housing & Finish Pure polyester powder coated die-cast aluminium housing in greyfinish with aesthetically designed heat sink for efficient thermal management,sturdiness & excellent corrosion resistant. M16 gland is used for cable entry, Lightsource High efficiency long life LED module with SMD LED package mounted onMCPCB. Lumen efficacy of LED >140 lm/W and viewing angle of 120°. Optics PCreflector for maximum light output. Tempered protective toughened glass, thermalshock and impact resistant (IK-07) fixed to the housing ,Electronic driver Poweredby Built-In Potted, isolated electronic LED driver (SMPS based constant currentsupply) with lower THD, Output Open / Short Circuit protection, Over Voltageprotection, Surge Voltage, Protection upto 6 kV & other safety test as per IS 15885Part-2/Sec 13. Mounting Wall or surface mounting using adjustable MS cradle ofthickness 4.00 mm is provided with the f fixture for 360° angular rotation ofluminaire, ∙ Operating temperature: -10 °C to +45 °C ∙ Operating voltage range: 140V - 270 V ∙ Average life L70 B50 : 50000 hours, Power Factor ≥0.95 , THD <10 (%)Colour Temp. 5700 (CCT) CRI ≥70(Ra) System Lumens 27500(Lm), IP66, IK07
2039250 watt (Make-havells)
2040E A R T H I N G
2041Earthing with G.I. earth plate 600 mm X 600 mm X 6mm thick including accessories, and providingmasonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 Meter long etc.with charcoal/ coke and salt as required.
2042Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
2043Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
2044BOUNDARY WALL
2045Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
2046All kinds of soil
2047Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
20481:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size)
2049Providing and laying in position specified grade of reinforced cement concrete, excluding thecost of centering, shuttering, finishing and reinforcement - All work up to plinth level :l
20501:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
2051COLUMN
2052Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
2053COLUMN
2054Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
2055Thermo-Mechanically Treated bars of grade Fe-500D or more.
2056Centering and shuttering including strutting, propping etc. and removal of form for
2057Lintels, beams, plinth beams, girders, bressumers andcantilevers
2058Column
2059Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
2060Cement mortar 1:4 (1 cement :4 coarse sand)
206112 mm cement plaster of mix :
20621:6 (1 cement: 6 coarse sand)
2063Finishing walls with Acrylic Smooth exterior paint of required shade :
2064New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
2065Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
2066Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
2067Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
2068Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retainhorizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq. mm with tape (0.52 mm thick) and weight 43.478 gm/ metre(cost of M.S. angle, C.C. blocks shall be paid separately)
20696.00 MAIN GATE
2070Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
2071All kinds of soil
2072Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
20731:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size)
2074Providing and laying in position specified grade of reinforced cement concrete, excluding thecost of centering, shuttering, finishing and reinforcement - All work up to plinth level :l
20751:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
2076COLUMN
2077Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
2078COLUMN
2079Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
2080Thermo-Mechanically Treated bars of grade Fe-500D or more.
2081Centering and shuttering including strutting, propping etc. and removal of form for
2082Lintels, beams, plinth beams, girders, bressumers andcantilevers
2083Column
2084Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in
2085Cement mortar 1:4 (1 cement : 4 coarse sand)
2086Finishing walls with Teracotta brick tiles of required shade :
2087Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
2088Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
2089Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
2090Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to bepainted with two or more coats of synthetic enamel paint of required shade and of approved brand &manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted inblack and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxypaint over and including appropriate priming coat including all leads and lifts etc. complete as perdrawing , specification and direction of Engineer-in-charge.
2091Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm
2092MAIN GATE INNER 4.50 M
2093Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
2094All kinds of soil
2095Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
20961:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size)
2097Providing and laying in position specified grade of reinforced cement concrete, excluding thecost of centering, shuttering, finishing and reinforcement - All work up to plinth level :l
20981:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
2099COLUMN
2100Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
2101COLUMN
2102Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
2103Thermo-Mechanically Treated bars of grade Fe-500D or more.
2104Centering and shuttering including strutting, propping etc. and removal of form for
2105Lintels, beams, plinth beams, girders, bressumers andcantilevers
2106Column
2107Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in
2108Cement mortar 1:4 (1 cement : 4 coarse sand)
2109Finishing walls with Teracotta brick tiles of required shade :
2110Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
2111Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
2112Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
2113CATTLE CATCHER
2114Excavation in foundation in ordinary soil (Loam clay or sand) including lift up to 1.5m and read up to 30m and including filling watering and ramming of excavated earth into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth and directed by Engineer in charge upto a distance of 30m from the foundation trenches including all T&P pbowereh and basket etc. complete.
2115Providing and laying in cement concrete1:4:8 (1 cement : 4coarse sand :8 graded Stone agregate 40 mm nominal size) including supply of all material, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation and floors.
2116RCC UP TO PLINTH LEVEL (1:1.5:3)FOR RAFT/ FOOTINGS
2117First Class brick work in 1:4 cement & coarse sand of 2.25 F.M. mortar in foundation and plinth including supply of all materials, labour and T&P etc. required for proper completion of work.
2118Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc..
2119trenching and refilling etc..
2120RCC ROAD
2121Construction of granular sub-base by providing close graded Material conforming tospecifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippersto work site, for all leads & lifts, spreading in uniform layers of specified thickness with motorgrader on prepared surface and compacting with vibratory power roller to achieve the desireddensity, complete as per specifications and directions of Engineer-in-Charge.
2122Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacityafter excavating earth to an average of 22.5 cm depth, dressing to camber and consolidatingwith road roller including making good the undulations etc. and re-rolling the sub grade anddisposal of surplus earthwith lead upto 50 metres.
2123Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
2124Providing and laying design mix cement concrete of M-30 grade, in roads/taxi tracks/ runways, using cement content as per design mix, using coarsesand and graded stone aggregate of 40 mm nominal size in appropriateproportions as per approved & specified design criteria, providing dowelbars with sleeve/ tie bars wherever required, laying at site, spreading andcompacting mechanically by using needle and surface vibrators, levellingto required slope/ camber, finishing with required texture, including steelform work with sturdy M.S. channel sections, curing, making provision forcontraction/ expansion, construction & longitudinal joints (10 mm wide x50 mm deep) by groove cutting machine, providing and filling joints withapproved joint filler and sealants, complete all as per direction of Engineerin-charge
2125Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
2126Thermo-Mechanically Treated bars of grade Fe-500D or more.
2127Providing & Laying trimix vaccum dewatering the concrete floors using Tremix .including curing ,providing and mixing of hardening compound @ 2 kg/sqm ,cutting of VDF floor 100-150mm thick with diamond saw system as per specification including filling of colpor of fosroc make etc .complete as per specification and drawing .
2128Providing & Laying trimix Plastic sheet 125 micron make etc .complete as per specification and drawing .
2129INTERLOCKING DETAIL
2130Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
2131With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
2132Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacityafter excavating earth to an average of 22.5 cm depth, dressing to camber and consolidatingwith road roller including making good the undulations etc. and re-rolling the sub grade anddisposal of surplus earthwith lead upto 50 metres.
2133DRAIN 450X750(791.87 M)
2134Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
2135Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
21361:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
2137Brick work in 1:4 cement motar (cement : coarse sand) in foundation.
2138Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.
213912 mm cement plaster
214025mm thick cement concrete 1:2:4 (1 cement :2 coarse sand :4 stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors.
2141DRAIN 350X450
2142Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
2143Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
21441:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
2145Brick work in 1:4 cement motar (cement : coarse sand) in foundation.
2146Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.
214712 mm cement plaster
214825mm thick cement concrete 1:2:4 (1 cement :2 coarse sand :4 stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors.
2149Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
215040X40X5
2151GARBAGS /DUSTBIN
2152BASKET BALL COURT
2153Excavation in foundations in ordinary soil (Loam clay or Sand) including lift upto 1.5 m. lead upto 30m and dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the engineer I/C within a lead of 30 m.
2154Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
2155Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
2156Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)
2157Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km from the site of work and including watering dressing etc.rate to including cost of all materials labour and T&P etc . Required for proper completion of the work.
2158Construction of granular sub-base by providing close graded Material conforming tospecifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desireddensity, complete as per specifications and directions of Engineer-in-Charge.
2159With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
2160Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacityafter excavating earth to an average of 22.5 cm depth, dressing to camber and consolidatingwith road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
2161Providing and laying of outdoor synthetic mat including cost of materials ,labour etc complete.
2162Basket bal pole and net 8ft height .
2163Basket bal ground border painting
2164BADMINTON COURT
2165Excavation in foundations in ordinary soil (Loam clay or Sand) including lift upto 1.5 m. lead upto 30m and dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the engineer I/C within a lead of 30 m.
2166Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
2167Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
2168Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)
2169Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km from the site of work and including watering dressing etc.rate to including cost of all materials labour and T&P etc . Required for proper completion of the work.
2170Construction of granular sub-base by providing close graded Material conforming tospecifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desireddensity, complete as per specifications and directions of Engineer-in-Charge.
2171With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
2172Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacityafter excavating earth to an average of 22.5 cm depth, dressing to camber and consolidatingwith road roller including making good the undulations etc. and re-rolling the sub grade anddisposal of surplus earthwith lead upto 50 metres.
2173Badminton pole and net .
2174Badmintoncourst border painting
2175SIGNASE WORK
2176Cautionary /warning sign boards of equilateral triangular shape having each side of 900 mmwith support length of 3650 mm
2177Class room Name Plate (12x10inch ) M.S.Sheet with retroreflective paint.
2178Deluxe Notice Board is a versatile solution designed for modern offices, classrooms, and training spaces. This dual-purpose board features a smooth writing whiteboard on one side and a high-quality fabric notice board on the other, making it ideal for both presentations and information display. The whiteboard offers a glare-free, easy-to-clean surface for writing and brainstorming, while the notice board
217972 x 48 x 5.5 inch
2180FLAGE POST 10 METER HEIGHT WITH FOUNDATION
2181sign board
2182Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
2183All kinds of soil
2184Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
21851:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size)
2186Providing and laying in position specified grade of reinforced cement concrete, excluding thecost of centering, shuttering, finishing and reinforcement - All work up to plinth level :l
21871:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
2188COLUMN
2189Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
2190Thermo-Mechanically Treated bars of grade Fe-500D or more.
2191Centering and shuttering including strutting, propping etc. and removal of form for
2192Column
2193Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thickaluminium sheet, face to be fully covered with high intensity encapsulated type heat activatedretro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver whiteor other colour combination including subject matter, message (bi-lingual), symbols andborders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall beactivated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixingthe same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S.angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and includingmaking holes in pipes, angles flats, providing & fixing M.S. message plate of required size,steel work to be painted with two or more coats of synthetic enamel paint of required shadeand of approved brand & manufacture over priming coat of zinc chromate yellow primer(vertical MS-Tee support to be painted in black and white colours).Backside of aluminiumsheet to be painted with two or more coats of epoxy paint over and including appropriatepriming coat including all leads and lifts etc. complete as per drawing , specification anddirection of Engineer-in-charge.
2194Cautionary /warning sign boards of equilateral triangular shape having each side of 900 mmwith support length of 3650 mm
2195KIOSK WATER
2196Payment MethodCoinMachine TypeRO UVDispenser TypeCard OperatedPlant Capacity500 LPHOperation ModeCard OperatedVehicle TypeFloor mountedStorage Capacity500 LDisplay TypeLEDUsage LocationOutdoorWater SourceBorewellVoltage2kvInbuilt Storage Tank200 ltrTemp Range10-20Water DispensingNormal and coldWarranty1 yearAutomation GradeAutomaticPurification Stage5 stageModel Name/NumberOASIS Ultra atm250lrInstallation TypeFloor standingMountingFloorWeight150 kgBuilt TypeStainless steelPressure Around4-6 kgInlet Flow Rate500 lphNumber Of Taps3Float SwitchYesProductivity250 lphWorking Pressure4 kgI Deal InNew OnlyMaterialStainless steelCountry of OriginMade in India
2197250 LTR Water ATM Machine
2198DG SET
2199Supplying, Installation, Testing & Commissioning of‘Silent Type Diesel Generating set as per CPCB IV +or better norms along with having Prime Power Ratingof KVA as below, 415 volts at 1500 RPM, 0.8 laggingpower factor at 415 V suitable for 50 Hz, 3 phasesystem & for 0.85 Load Factor, including testing atfactory and site with fuel, load for test and othernecessary arrangements Complete as per CPWDspecifications, should have QR code which shouldcontain drawing, test report OEM manual,Geo- Tag ofmanufacturing location, rating plate as per relevant ISCode etc. and consisting of the followings:
2200(A) Diesel Engine:Tourbocharged Diesel engine 4 stroke water cooled,multi cylinder, dynamically balanced fly wheel, electricstart of suitable BHP at 1500 RPM suitable for aboveoutput of alternator at 40 0C, 50% RH & at 1000 MeterMSL , capable of taking 10% over loading for one hourafter 12 hours of continuous operation. The engine willbe with Electronic governor, Dry type Air filter withservice indicator, first filling of engine fuel (aftercommissioning) lubricating Oil, Coolant and otherconsumables complete with all the requiredaccessories, the Electronic governor shall be as perISO 8528.The engine shall comply to the latest CPCBnorms (CPCB IV + or better) and Conforming to BS5514, BS 649, IS 10000, IS 10002, IS 13018 and asper CPWD specifications
2201(B) Engine mounted Instrument Panel fitted with andhaving digital dis Plate for following:(i) Start-stop switch with key(ii) Water temperature indication(iii) Lubrication oil pressure indication(iv) Lubrication oil temperature indication(v) Battery charging indication and Voltage indication(vi) RPM indication(vii) Over speed indication(viii) Low lubricantion Oil trip indication(ix) Engine Running Hours indication(x) Fuel Level
2202(C) Alternator:Synchronous alternator rated of appropriate KVA, 415volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8lagging power factor at 40 0C, 50% RH & at 1000Meter MSL. The alternator shall be having ScreenProtected Drip Proof (SPDP) enclosure IP23,brushless, continuous duty, dynamically balancedrotor, capable of taking 10% over loading for one hourafter 12 hours of continuous operation, selfcooled,self-excited and self-regulated through AVRconforming to IS13364(Part 2)/IS: 4722/BS 2613suitable for tropical conditions and with class- Hinsulation.
2203(D) Base Frame & Foundation:Both the engine and alternator shall be mounted onsuitable base frame made of MS channel withnecessary reinforcement which shall be installed onsuitable cement concrete foundation and vibrationisolation arrangement as per recommendations ofmanufacturer.
2204(E) FUEL TANK:Daily service fuel tank of suitable liters capacity as perCPWD Specifications, fabricated out of 3 mm thickM.S. sheet complete with all standard accessories andfuel piping between fuel tank and diesel engine withMS class ‘C’ pipes of suitable dia. Complete withvalves, level indications & accessories as required asper specifications.(F) Exhaust System:
2205Dry exhaust manifold with hospital type exhaustsilencer and catalytic convertor.(G) Starting System:12V/24V DC starting system comprising of startermotors: voltage regulator and arrangement for initialexcitation complete with suitable numbers of batteries(180 AH capacity lead acid SMF type) as required asper specifications. The battery shall be housed insidethe acoustic enclosure of DG Set.
2206(I) AMF Panel:Free standing floor mounted IP 42 automatic mainsfailure control panel including auto by-pass, suitablefor KVA as below for silent type DG set complete withrelays, timers, set of CTs for metering & protection andenergy analyser to indicate currents, phase and linevoltages, frequency, power factor, KWH, Kilo VoltAmpere Reative Hour (KVARH), KVA (Phase & Total),KW & provision for overload, short circuit, restrictedearth fault, under frequency, power (aluminium) andcontrol (copper ) cabling of suitable size upto 15 meterbetween AMF panel, LT Panel and DG Set includingconnection interconnection etc. as required, allcomplete and inter locking and communication/Ethernet /RS485/SNMP port open protocol for BMSintegration including suitable software, the panel shallbe of DG Set OEM make etc. as per approved by
2207Engineering in charge and including the following:1. Suitable numbers and appropriate capacity 4 polemotorised electrically operated draw out with cradletype 3 position ACB/ MCCB with electronic release forO/C & E/F and shunt trip.2. Auto/Manual/Test/Off selector switch3. Protection for under and over voltage phasereversal (2 nos Over voltage relay, 2 Nos. reversepower relay and 2 Nos. under voltage relay).4. 3 Sets of current transformers 15 P 10 accuracy forprotection and 15 VA class-I for metering5. Energy analyser unit to indicate current, Voltage( LN& L_L), kW, kVA (Phase & Total), Frequency, KWH,PF.6. LED Indicating lamps for load on mains and load onset7. Fuse/ MCB for instruments8. Battery charger, complete with transformer/ rectifier,
2208D.C. voltmeter and ammeter, selector switch fortrickle, off and boost and current adjustment.9. Main supply failure monitor10. Supply failure timer11. Restoration timer12. Control unit with three impulse automatic enginestart/stop and failure to start lockout.13. Impulse counter with locking and reset facility.14. ON/OFF/Control circuit switch with indicator15. Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning16. Protection for over/under Frequency, Loss of ACsensing, Over Current, Unbalancing load with suitablenumber of relays and accessoriesing.
220917. Maintenance notification based on Engine RunHour & due date.18. Load Management through PLC to achieve autoopening and closing of incomer breakers, bus couplerswitching of essential panel , interlocking providingsignal to AMF Panel for load status and AMF shallgive command to DG Set to auto start / auto stopdepending upon load status and requirement etc. andnecessary hardware and software required to performthe operation shall be provided by the contractorincluding all control wire.
221062.5KVA
2211Automatic Off- White Industrial AMF Panel, 50 KVA AMF Panel, for GeneratorBrandRoshanApplicationDuring Mains Failure and complete automation of your generartorPhaseThree PhaseUsage/ApplicationUsed for automation of generator during power failurePower SourceElectricalUsageGeneratorMaterialMild SteelColorOff- WhiteFrequency50 HzModel Number50KVA_AMF_PanelPanel TypeContactor TypeGenerators Range50 KVACapacity80 AmpsModel50 KVA AMF PanelWarranty12 MonthsTypecontactor base auto changeoverPlace Of OriginChennaiBody MaterialMild SteelConditionNewAutomatic GradeAutomatic
2212DG FOUNDATION
2213Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
2214All kinds of soil
2215Excavating, supplying, stacking and filling of local earth (including royalty) by mechanicaltransport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
2216Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
22171:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
2218Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in
2219Cement mortar 1:4 (1 cement : 4 coarse sand)
2220Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15°landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived fromnatural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).-M20
2221All works above plinth level upto floor V level
2222Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
2223Thermo-Mechanically Treated bars of grade Fe-500D or more.
2224Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
2225Cement mortar 1:4 (1 cement : 4 coarse sand)
222612 mm cement plaster of mix :
22271:6 (1 cement: 6 coarse sand)
2228Finishing walls with Acrylic Smooth exterior paint of required shade :
2229New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
2230Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
2231Capcity in Per Liters
2232Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
2233Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
2234Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (basemetal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on bothside of the sheet and polyester top coat 15-18 microns. Sheet should have protective guardfilm of 25 microns minimum to avoid scratches during transportation and should be suppliedin single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixedusing self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete uptoany pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters andtrusses and including cutting to size and shape wherever required.
2235COMPOST DETAIL
2236Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
2237All kinds of soil
2238Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
22391:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
2240Brick work with common burnt clay F.P.S. (non modular brick) bricks of class designation 7.5
2241Cement mortar 1:4 (1 cement : 4 coarse sand)
2242Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15°landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived fromnatural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).-M20
2243All works above plinth level upto floor V level
2244Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
2245Thermo-Mechanically Treated bars of grade Fe-500D or more.
2246SANITARY PAD WENDING
2247RMAX Fully Automatic Electronic Sanitary Napkins Pad Vending Machine (50 Napkins Storage Capacity | Compact Design | Coin Operated)
2248Supplying, Installation, Testing & Commissioning offollowing capacity passenger Machine room less(MRL) lift with regenerative drive as per CPWDGeneral Specification for Electrical Works (Part-III Lift& Escalator) 2003, BIS Codes, NBC 2016 asamended upto date having provision for barrier freeaccess as per Harmonised Guidelines & Standards forUniversal Accessibility in India - 2021 of MoHUA,serving different floors in the lift shaft as per detailedspecifications enclosed and as under including allother equipment and accessories complete asrequired:-
2249(i) Speed-1 MPS(ii) Floors-5 (G+4)(iii) Travel -17 Meters (approx.)(iv) Stops & opening- 5 stops and 5 openings(v) Controller: A.C. variable voltage & variablefrequency(vi) Automatic rescue device (ARD) complete with drymaintenance free batteries as required.vii) Operation: Microprocessor based single automaticpush button/simplex selective collective/duplexcollective selective with/without attendant(viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wiressystem(ix) Car Enclosure: Stainless steel scratch proof(Moon Rock/Honeycomb/ Hairline Finish) on all sidesand stainless steel decorative ceiling with fans (indirectthrow) and LED fitting.(x) The car flooring should be smooth and antiskid asapproved by engineer-in-charge.(xi) Type of doors(a) Car: Power operated, centre opening horizontalsliding stainless steel scratch proof (MoonRock/Honeycomb/ Hairline Finish).(b) Landing doors: stainless steel scratch proof .(xii) A hand rail not less that 600mm long at 900mmabove floor level to be fixed adjacent to control panelin the lift car.
2250announce the position of the elevator in the hoistway as the car passes or stops at floor served by theelevator.(xiv) Closed loop Control System, protection againstpower fluctuation, self diagnostic control, Landingdoors 2 hours Fire rated, Overload detection andprotection, Overspeed Governer, Dot Matrix LED D &P Indicators In Car & Landings, BMS Compatibility,tamper proof infrared curtain covering almost the entireheight of the lift car door, Alarm horn, Anti NuisanceOperation, CCTV camera system with 4 MP IPcamera, suitable NVR and HDD for 30 days storagebackup , Firemen switch, 2/3 way intercom,Emergency Stop Switch with battery backup for fanand light fitting for 1 hour, pit ladder.(xv) The lift doors shall have a vision panel to enablepersons with hearing impairment tosignal for help or assistance in the event of anemergency.(xvi) An appropriate technological support be provided(Throughemergency messaging |services or alarms etc.) torespond to the emergency requirements of person withhearing impairment or deafness.(xvii) In case of failure of ARD or other electronicdevices, a provision of manual rescue be provided
225113 passenger (884kg)
2252Cost of civil work as per lift company guidline work
2253Extra for levelling & neatly dressing of disposed soil completely as directed by Engineerin- charge.
2254Excavating, supplying, stacking and filling of local earth (including royalty) by mechanicaltransport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58531038
AUTHORITY Government Departments
TENDER VALUE 27.35 Crore
LAST DATE 21-11-2026
Authority
Authority Name Uttar Pradesh Projects Corporation Limited
Work Description Tender for Proposed Construction Of Kendriya Vidyalaya At Hazipur Distt.- Vaishali, State-Bihar. (Notice No. -11/Uppcl/Gm-5/E-Tender/2026-27 Dated: 30-10-2026)
Basic Detail
Tender No 11/UPPCL/GM-5/E-TENDER/2026-27 Dated-30.10.2026
Bidding Type Tender
Location
City Vaishali
State Bihar
Key Dates
Publish Date 14 Nov 2026
Submission Date 21 Nov 2026
Open Date 21 Nov 2026
Finance
Tender Value 27.35 Crore
Tender Fee 17700
EMD 54.71 Lakhs
Exemption Not Available
Document List
a19b0b97-4cc5-47a4-a567-d8befbd9077d.html
BIDDOC.pdf
BOQ_2293552.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Nov 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.