Tender for Repair To Roof Treatment & Chajja Of Otm & Md Accn At Various Location Under Age B/R-Ii At Mil Stn Yol

BOQ

Name of Work:- REPAIR TO ROOF TREATMENT & CHAJJA OF OTM & MD ACCN AT VARIOUS LOCATION UNDER AGE B/R-II AT MIL STN YOL
Sl. No. Item Description
1M&L for cement concrete type B-0 1:2:4 (12.50mm graded crushed stone aggregates) as in padding over roofs, lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, copings, kneelers, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, use of form work including demolition of concrete of any description and in any position complete all as specified and directed by Engineer in Charge.
2M&L for water-proofing treatment on horizontal and vertical surfaces by applying oil bound bitumen primer and 0.40kg/ Sqm and providing 4mm thick APP modified water proofing membrane weighing not less than 4 kg/ Sqm reinforced with non woven polyester matt weighing not less than 160 gms/Sqm incl minimum 10cm side lap and 15cm end/ longitudinal lap torch sealed and bonded and applying two coats of blown grade hot bitumen 90/15 over and below the membrane @ 1.20 kg/ Sqm in drying over the membrane finished with solar reflective bituminous paint/ primer @ 0.10 kg/ Sqm over RCC roof slabs/ projections/ parapets after cleaning the surfaces by removing dust, dirt etc, as manufacturer's instructions including reremoval of existing APP membrane sheets of any thickness and position complete all as specified and directed by Engineer in Charge
3M&L for 10mm avg thick rendering cement mortar 1:3 mixed with liquid water proofing admixture complete all as specified and directed by Engr-in Charge (Note liquid WPC shall be measured and paid sepeately)
4Supply only liquid Waterproofing compound
5M&L brick work with fly ash bricks, straight or curved on plan exc 6m redius in CM 1:6 including demolition of brick/stone masonry all as specified and as directed.
6Taking down cement plaster of any description on brick/stone walls, concrete surfaces including racking out joints, hacking for key, scrubbing down with water, remove dust, debries/rubbish etc complete all as specified and as directed.
7M & L rendering 15mm thick in cement mortar 1:4 on external fair faces of brick walls or on concrete surfaces plastered surfaces finished even and smooth without using extra cement with water proofing compound as per manufactare instruction complete all as specified.(Note liquid WPC shall be measured and paid sepeately)
8M & L for rendering 15mm thick in cement mortar 1:6 on internal fair faces of brick walls or on concrete surfaces, finished even and smooth without using using extra cement complete all as specified and as directed.
9M&L for rendering 5mm thick in cement mortar 1:4 on fair faces of RCC surfaces and including applying cement slurry in bottom of slab or ceiling, chajjas, fins & facias etc finished even and smooth without using extra cement complete all as specified and directed..
10M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance , dirt resistance exterior paint of required shade (Company Depot tinted) with silicon additives @ 1.43/10Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm over new surfaces complete, all as specified and as directed by Engr-in-Charge.
11Two coats of cement base paint over priming coat with mechanical roller on newly plastered surfaces including preparation of surface complete, all as specified and as directed.
12M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance , dirt resistance exterior paint of required shade (Company Depot tinted) with silicon additives @ 1.43/10Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm over old painted surfaces including preparation of old surfaces after complete removal of existing treatment all as specified
13Preparation of old decorated plastered or unplastered surfaces including cleaning by brooming down or with steel wire brushing scraping down smoke soot, moulded moss and efflorescent salts and cleaning oil and greasy spots and applying one coat of white wash on Ceiling with mechanical roller all as specified and as directed.
14Three coats of white wash with mechanical roller on newly plastered ceiling surfaces including preparation of surface complete, all as specified and as directed.
15Preparation of old decorated plastered or unplastered surfaces including cleaning by brooming down or with steel wire brushing scraping down smoke soot, moulded moss and efflorescent salts and cleaning oil and greasy spots and applying one coat of white wash on walls with mechanical roller all as specified and as directed.
16Three coats of white wash with mechanical roller on newly plastered wall surfaces including preparation of surface complete, all as specified and as directed.
17Taking down cement plaster/decayed concrete from RCC roof projections/upward parapet walls/ down ward facia/soffits and fins of RCC chajjas /beams/columns/balconies etc. Supply and fixing by means of nailing wire netting of galvanised wire 1.40 mm dia and mesh size 20 mm and brushing neat cement slurry with 3.00 kg of cement/sqm and M & L for 20 mm thick cement rendering in two layers of 10 mm each (top/final layer shall be rendered after final setting of under layer) in CM 1:3 on concrete surfaces including scaffolding at a height upto 7.00 mtrs. etc complete all as specified and directed.
18M & L 15mm dia bore steel tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floors including taking down or up 15mm water tubing.complete all as specified & directed
19M & L 20mm dia bore steel tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floors including taking down or up 20mm water tubing.complete all as specified and as directed
20M & L 25 mm dia bore steel tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floors including taking down or up 25mm water tubing. complete all as specified and as directed
21M & L for PVC (SWR) 110mm bore (dia) soil, waste and ventilating pipe, type B,singe socketed, in any length with Rubber Ring Joints fixed to walls, including taking down unserviceable pipe, fittings, etc, complete all as specified and directed..
22M & L for PVC (SWR) 110mm bore (dia) soil, waste and ventilating pipe,type B, singe socketed, in any length with Rubber Ring Joints fixed to floor including taking down unserviceable pipe, fittings, etc, complete all as specified and directed..
23M & L for PVC (SWR) 110mm bore (dia), Bends any type, with Access Door, etc. and Jointing with Solvent Cement, complete all as specified and as directed.
24M & L for PVC (SWR) 110mm bore (dia), Single T Junction equal or unequal with Access Door, etc. and Jointing with Solvent Cement, complete all as specified and as directed.
25S&F in repair for PVC (SWR) 75mm bore (dia) soil, waste and ventilating pipe, type B, singe socketed, in any length with Rubber Ring Joints fixed to in floor , including taking down unserviceable pipe, fittings, etc, complete all as directed and all as specified.
26S&F in repair for PVC (SWR) 75mm bore (dia) soil, waste and ventilating pipe, type B, singe socketed, in any length with Rubber Ring Joints fixed to walls, including taking down unserviceable pipe, fittings, etc, complete all as directed and all as specified.
27S&F cast PVC (SWR) bends any radius for 75mm bore pipe complete all as specified.
28S&F for PVC (SWR) junction single, (Single T) equal or unequal for 75mm bore pipe complete all as specified.
29Dismantling water tanks n. exc. 500 ltr capacity and removing from site complete all as specified and directed..
30M & L for rotational moulded polyethene water storage tanks 500 litrs capacity (cylindrical vertical with threaded closed top) hoisted and fixed in position incl PVC float ball valve 20mm dia with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line all as specified in SSR part-I complete all as specified & directed
31Dismantling water tanks exc. 500 ltr & n exc 1000 ltrs capacity and removing from site complete all as specified and directed..
32M & L for rotational moulded polyethene water storage tanks 1000 litrs capacity (cylindrical vertical with threaded closed top) hoisted and fixed in position incl PVC float ball valve 20mm dia with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line all as specified in SSR part-I complete all as specified & directed
33Disconnecting of existing PVC /Ferro cement/MS Tank of capacity exc 500 ltr but n exe 1000 ltrs for cleaning and removing all scale and dirt etc from tanks and from mouth circulating pipes etc and hoisting if required , reconnecting and refixing in position all as directed by Engr-in-Charge
34Disconnecting of existing PVC /Ferro cement/MS Tank of capacity exc 250 ltr but n exe 500 ltrs for cleaning and removing all scale and dirt etc from tanks and from mouth circulating pipes etc and hoisting if required , reconnecting and refixing in position all as directed by Engr-in-Charge
35S & F for 0.63 mm thick galvanised corrugated mild steel sheeting with two corrugation side lap , fixed with 'J' or 'L' type or cranked hook bolts and washers in roof covering etc with grade of zinc coating 120 including dismantling of existing sheet complete all as specified and as directed.
36S & F for 0.63 mm thick plain galvanised mild steel sheeting in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 120 including dismantling of existing sheet complete all as specified and as directed.
37S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws incl dismantling of existing sheet complete complete all as specified and as directed.
38Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of existing sheet complete all as specified and as directed.
39M & L for second class hard wood in scantling clean sawn fixd in framed complete all as specified and directed including dismantling timber scantling over 40 Sqcm in sectioncomplete all as specified and as directed.
40Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
41S & F for mild steel roof trusses (framed), trussed, purlins and similar works(beam,Tee,, angle, channel or flat section) including distances pieces, cleats etc conforming to FE-290, Grade E-165 complete all as specified and as directed.
42Preparation of new steel and iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
43Dismantling of ceiling board (fibre, pulp, Insulation etc.) or insulation of boards/slab /blankets, any thickness with frame work including cover fillets cornices etc. complete all as specified and as directed.
44GI frame work anodised snap grid frame work of size of size 605 mm X 605 mm as in false ceiling, flat or sloping (pattern as per manufacturer's catalogue/ instructions), cutting holes for electrical fittings fixed on and including aluminium tee of size 25mmX25mmX1.50 mm as main runner, aluminium tee of size 25mmX25mmX1.25 mm as cross runner and aluminium angle of size 25mmX25mmX1.25mm at the perimeter suspended from soffit at approx 900 mm centre to centre with hangers 6 mm dia galvanised (length as per site requirement) adjusting level fixed to roof by means of ceiling cleats made out of galvanised iron flat 40 mm X 3 mm size, 60 mm long and expansion hold fasteners 12.5 mm dia, 40 mm long including necessary scaffolding all as specified and directed.
45M&L for 4 mm thick non asbestos fibre cement building boards of size 600x600mm (ED board)as in ceiling fixed or laid/ inserted to timber/ GI/ aluminium frame work fixed with nails, all as specified.
46GI frame work for seamless ceilling comprising of GI permeter channel 0.55mm thick with two unequal flanges of 20mm and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.90mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section of 0.55mm thickness having kurled web of 50mm and flange of 26mm each lips of 10.50mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre including Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish and applying two coats of distemper over 1mm thick wall care putty, complete all as specified and directed by Engr-In-Charge.
47M&L for sunken slab treatment comprising of following: (a) Taking out/down old existing sunken slab treatment including tiling, PC and cleaning the old RCC surfaces of sunken slab including removal of the rubbish out of campus complete all as specified. (b) M&L for 25mm thick PCC type B-1 using 20mm graded stone aggregate over cleaned sunken slab surfaces. (c) M&L for applying bitumen priming coat/tack coat over PCC @ 0.30 kg/Sqm. (d) M&L for 4mm thick APP modified water proofing membrane weighing not less than 4 Kg/Sqm reinforced with non-woven polyester matt weighing not less than 160gm/sqm including minimum 10cm side lap and 15cm end lap torch sealed and bound. (e) M&L for applying bitumen grade 85/25 over primer coat @ 1.20 Kg/Sqm. (f) M&L for 25mm thick plastering (in two layers 15mm 1st layer, 10mm second layer) in Cm 1:4 mixed with liquid water proofing admixture as per manufacturer instruction over 225mm thick PCC 1:4:8 using 40mm graded stone aggragate complete all as specified and directed by Engr-In-Charge.
48Material and Labour for waterproofing of exterior walls, include complete removal of existing plaster including raking out joints and applying two coats of acrylic polymer modified high performance coating (Smartcare Ultra Block 2K). The treatment shall be done from ground level and providing 15mm thick cement plaster in CM1:4 finished even and smooth complete all as specified and directed by Engr-In-Charge.
49Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-In-Charge.
50M & L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match as in Skirting, Dados, etc., laid over and including 10mm thick rendering in CM 1:4 complete all as specified and as directed.
51Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15 cm thick bellow or above ground level complete all as specified and directed by Engineer by Charge.
52M&L Cement concrete 25mm thick type B-1, 1:2:4 (20mm graded aggregate) Finishing cement concrete surface even and smooth Without using extra cement.
53Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match,laid overand including 15mm thick cement screed /rendering in CM 1:6 complete all as specified and as directed.
54S& F in repair PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm dia of outlet complete all as specified and directed by Engr-In-Charge.
55S&F in repair Vitreous China wash down water closet pan with 'P' trap (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) Pedestal pan and trap, including connection to drain (or outgoing pipe) and to flushing pipe, anti syphonage pipe, etc.complete all as specified and directed.
56S & F in repairs for 10 ltr capacity PVC valveless syphonic action type flushing cistern, low level white with inlet ball valve float and handle incl brackets complete all as specified and directed
57S & F in repairs for vitreous china wash basin white flat back, size 450x300mm incl brackets, cutting for and pinning in ends or brackets withwaste coupling of PTMT bore of 32 mm dia discharge pipe (half or full threaded) minimum wt 32 mm (45 gms/40-60 gms) complete all as specified and directed.
58S&F in repair Pillar taps cast copper alloy with capstan heads, chromium plated screwed down high pressure with or without lettered Hot or cold with long screwed shanks and flynuts, scewed for union pipe and fixed to 15mm dia pipe complete all as specified and directed
59S&F in repair health faucet (ABS body with 1 metre long easy flex in chrome finish tube and wall hook complete with accessories, fixed in repairs . Make Jaquar, Cera or Equivalent
60S& F in repair one piece floor mounted toilet water closet of size (WxPxH) 360 x 675x750 mm white or tinted S trap 300 mm trendy square design slim UF ezee close seat cover wash down system dual flush (6/32 ltrs) mechaniism with necesary fixing bolts /screws etc compklete all as specified, Make Jaquar Cat No OPS-WHT 15853S300UF , Somany , Cera or Equalent.
61S&F in repair counter type (oval shaped) vitreous china wash basin premiun quality of size 610x 385x 130mm including brackets waste coupling & Pipe of 32 mm dia and fixed with including all connected items complete all as specified and directed by Engr-In-Charge.
62M&L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over and including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes CM 1:6. complete all as specified and directed by Engr-In-Charge.
63M&L for 20mm thick Granite (of any type) tiles machine cut, in skirting/dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over and including rendering 10mm thick on fair faces of brick work or concrete surfaces CM 1:4 complete all as specified and directed by Engr-In-Charge.
64M&L for Reinforced cement concrete (Nominal mix) Type B1 1:2:4 (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as directed.
65Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-In-Charge.
66S&F in repair Brass CP mixer (i.e, wall mixer/center hole mixer/ sink mixer) for mixing hot & cold water screwed down for iron pipe 15mm bore and fixed in repairs complete all as specifeid and directed by Engineer in Charge.
67S&F in repair stop valves/angle valve 15mm bore, cast copper alloy, fancy type cromium plated screwed down, high pressure, with carutch or butterfly handle, screwed both ends for iron pipe or for unions.
68All as per srl item No 67 above, but with long shank and cup (concealed type)
69S&F in repair Brass cromium plated shower rose 125 mm size with swivel joints including fixing to steel pipe or union all as specified.
70S&F in repair Bibtaps 15mm bore, fancy type cromium plated with butterfly handle, screwed down, high pressure, with carutch or butterfly handle, screwed both ends for iron pipe or for unions.including wall flange complete.
71S&F in repair Sheet glass shelf assembly consisting of 50mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long all as specified and as directed.
72Supply & fixing in repair CP soap dish 150mm size complete all as specified and directed by Engineer-in-Charge
73S & F in repair brass cromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed by Engr-In-Charge.
74S&F PVC connections 15mm, 450mm long with PTMT nuts washers etc complete all as specified and directed.
75S&F in repair 25 mm dia gun metal ,globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed by Engr-In-Charge.
76S&F in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed by Engr-In-Charge.
77S&F in repair toilet paper holder Make jaquar or equivalent.
78S&F for Urinal with sensor with complete delivery, installation, and commissioning of an automated, touch-free urinal system, specification as follows:-1. The Urinal Bowl (Vitreous China / Ceramic or Stainless Steel)• Material: Typically made from high-grade, glossy white or colored vitreous china (or heavy-duty stainless steel for high-vandalism public spaces).• Type: Available in half-stall, full-stall, wall-hung, or back-inlet/top-inlet configurations.• Dimensions: Common standard commercial sizes range roughly around 310 × 305 × 620 mm up to larger stall designs (485 × 310 × 710 mm), depending on the maker (such as Hindware, Jaquar, or Cera). 2.Accessories Included in S&F:• Wall mounting brackets, heavy-duty brass/expansion screws (typically 60mm long), and anchor plugs.• Water spreader/inlet connection and a 32mm/50mm waste trap, LDPE/PVC discharge pipe, and floor/wall union joints.• Joint pointing sealed cleanly with white cement or silicone around the back-wall fixture.3. The Automatic Sensor & Flushing Mechanism• Sensor Technology: Infrared (IR) or motion-detection sensor that senses the user's presence.• Operation Cycle:• Pre-flush (optional on some models): Short wet flush as the user approaches or stands in range.• Main/Post-flush: Automatically triggers a measured volume of water (usually around 0.4 to 1.0 liters per flush) a few seconds after the user steps away.• Solenoid Valve & Control Box: Connected via a brass or plastic solenoid valve that opens and closes on demand.• Power Source: Can be battery-operated (using AA or AAA alkaline/sealed packs lasting 1–3 years) or AC/DC hardwired (mains power with battery backup).• Face Plate / Housing: Concealed or outwall (surface-mounted) stainless steel or chrome-plated brass/ABS face plate
79Water proofing treatment over terrace using SHALIURETHANE- BTD OF STP MAKE OR EQUIVALENT as approved by GE in two coats @ 1 kg/sqm in each coat, high solid content single component water based liquid applied elastomeric water proofing membrane as ASTMC 836 and ASTMD 6083, thickness of the membrane shall be 1.5mm, having solid content of more than 80% elongation of 500+(-) 50%, laid over reinforcing layer on non woven geo-textile mesh of 40/50, 50 gms, including applying self primer coat by diluting with 1:1 ratio @ 0.2 kg per sqm incl 10 mm thick plaster in CM 1:4 and surface preparation including cleaning of existing treatment with plaster complete all as specified and directed.
80Preparation of CGI/PGI sheet roof surfaces by removing all loose gravel, dust, dirt, corrosion, oil grease and other foreign materials by jet of dry air and clean the CGI/PGI sheet surfaces mechanically or by grinding to make the surfaces smooth and M&L for applying ShaliSeal PS PG conforming to SI-12118 Part-I; 1987 to seal holes of J/L hooks and applying one coat of cold applied adhesive ShaliBond APP @ 3.00 Sqm per Kg (Approx) on CGI/PGI Sheet surfaces as bonding adhesive to affix bituminous membrane with brush. S&F for unroll the APP membrane 1.50mm thick (TarFelt APP conforming to ASTM D-5147) over the tacky surface and bond it to the CGI/PGI sheet surfaces by applying unifrom pressure and finally membrane shall be coated with Super Silver sheild @ 7 to 9 Sqm/ltr to protect the membrane from UV rays and prevent degradation arising of exposure to sun light. Note: Roof treatment shall be carried out by expert applicator of the firm.
81Deduction to be made from BOQ for Sch 'A' Part-II (Schedule of credit) Note: Tenderers shall not quote for this schedule. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58530050
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 36 Lakhs
LAST DATE 09-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair To Roof Treatment & Chajja Of Otm & Md Accn At Various Location Under Age B/R-Ii At Mil Stn Yol
Basic Detail
Tender No GE/Y-102/2026-27
Bidding Type Tender
Location
City Kangra
State Himachal Pradesh
Key Dates
Publish Date 14 Nov 2026
Submission Date 09 Dec 2026
Open Date 11 Dec 2026
Finance
Tender Value 36 Lakhs
Tender Fee 500
EMD 72000
Exemption Available
Document List
b47b1fd5-5f32-4bfc-a2e8-80a01ad29028.html
BOQ_895543.xls
Tender102.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Dec 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

b47b1fd5-5f32-4bfc-a2e8-80a01ad29028.html

xls

BOQ_895543.xls

pdf

Tender102.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender