Tender For Provn Of Hall In Simulator Bldg P-150 For Installation Of Upcoming annual repair Vr Cuv Simulators In Mtti Including Provn Of Aluminium Doors, Wooden Doors And Floor Tiles For It Section Of Mtti Af Stn Avadi Under Ge Avadi
Tender Overview
Project Description
Tender for Provn Of Hall In Simulator Bldg P-150 For Installation Of Upcoming annual repair Vr Cuv Simulators In Mtti Including Provn Of Aluminium Doors, Wooden Doors And Floor Tiles For It Section Of Mtti Af Stn Avadi Under Ge Avadi
BOQ
| Sl. No. | Item Description |
| 1 | PART - I - PROVN OF HALL IN SIMULATOR BLDG P-150 FOR INSTALLATION OF UPCOMING AR VR CUV SIMULATORS IN MTTI (B/R Portion) |
| 2 | Earth work in surface excavation (in all kind of soil ) not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 4 | Providing and laying in position cement concrete of 1:4:8(1Cement: 4coarsesand(zone-III)derived from natural sources:8graded stone aggregate 40 mm nominal size derived from natural sources as per specifications and directions of Engineer- in-Charge. |
| 5 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 6 | All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for suspended floors, roofs, landings, balconies and access platform |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for Edges of slabs and breaks in floors and walls under 20 cm wide |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges |
| 13 | Steel reinforcement Thermo-Mechanically Treated bars of grade Fe-500D or more for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 14 | Steel reinforcement Thermo-Mechanically Treated bars of grade Fe-500D or more. for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 15 | Forming embakements/filling under floor including raising (or lowering) using moorum, spreading in layers nexc 30 cm thick watering, ramming/rolling and finishing with 95% procter density to required size, shape nexc 1.5 m high from base etc complete with power roller 8 to 10 ton capacity complete all as specified and as directed. |
| 16 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 17 | M & L for Supplying and stacking at site for 63 mm to 45 mm size stone aggregate |
| 18 | Providing and laying in position cement concrete of 1:2:4 (1Cement: 4coarsesand(zone-III)derived from natural sources:8graded stone aggregate 40 mm nominal size derived from natural sources as per specifications and directions of Engineer- in-Charge. |
| 19 | Brick work with non modular fly ash bricks cement mortar 1:4 (1 cement : 4 coarse sand) conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : |
| 20 | Providing and fixing 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with. |
| 21 | Providing and laying vitrified floor tiles in different sizes ( size of tiles 600 x 600 mm) ( thickness to be specified by manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours & shade ,laid over 20 mm thick of cement mortar 1:4( 1 cement :4 coarse sand), jointing with grey cement slurry @ 3.3 Kg / Sqm including grouting the joint with white cement & matching pigments etc complete. |
| 22 | Providing and laying Vitrified tiles size of tile 600x600 mm sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc.complete. |
| 23 | Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 24 | Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 25 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). |
| 26 | Providing and fixing Pre-laminated particle board with decorative lamination on both side12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 27 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.(A) With stainless steel cover plate minimum 1.25 mm thickness |
| 28 | Providing and fixing float glass panes of 4 mm thickness (weight not less than 10.00 kg/sqm) glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 29 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm With 12 mm mild steel U beading complete all as specified and directed. |
| 30 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources). |
| 31 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. |
| 32 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 33 | Rendering 12 mm thick in fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth in fine sand complete all as specified. |
| 34 | Rendering 15mm thick in fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth in fine sand complete all as specified. |
| 35 | Supply only integral water proofing compound |
| 36 | Rendering 6 mm thick cement plaster on ceiling surfaces in cement mortar 1:3 finished fair and even with a floating coat of neat cement of mix complete all as specified and directed. |
| 37 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour with two or more coats on new work complete, as per manufacturer's specificatio over including 2mm thick internal wall care putty finish . |
| 38 | Finishing wall New work ( Two or more coats applied @ 1.43 litre/ 10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10 Sqm with 100 % premium acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistance as per IS 15489 : 2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade ( Company Depot tinted ) with silicon additives |
| 39 | Preparation of new plastered ceiling surfaces and apply three coats of white wash etc complete all as specified and directed. |
| 40 | Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 20mm nominall size derived from natural sources) of 75 mm thick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand , including necessary excavation, levelling & dressing & finishing the top smooth. |
| 41 | M & L for Bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, at the junction of plinth protection surfaces complete all as specified. |
| 42 | Providing and laying 3 mm thick APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : |
| 43 | S&F roller blind with aluminium powder coated channel & PVC runners and fabric blinds fixed to window as per manufacture instruction complete as per sample kept in GE’s office . Make:ista or equivalent make approved by the GE |
| 44 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. |
| 45 | PART -II- PROVN OF HALL IN SIMULATOR BLDG P-150 FOR INSTALLATION OF UPCOMING AR VR CUV SIMULATORS IN MTTI (E/M Portion) |
| 46 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners 2 T capacity 5 Star rating inverter type complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). |
| 47 | Supply and fixing of GI powder coated brackets 16SWG for fixing of split Acs out door unit and including grouting with suitable size fastners complete. |
| 48 | Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input varition between 170V to 250V with out put voltage stablized at 230v with accuracy of +/- 2.5% and capacity 5KVA Make :- Servokon SK 410 C, V-guard or equivalent |
| 49 | Supply and fix copper tubing set 1/4\\" and 1/2\\" suitable for Split AC including PUF insulation and connected accessories, fixcing for outdoor unit for user requirement complete all as directed by eng-in-charge |
| 50 | Wiring for circuit/ submain wiring along with earth wire with the 2 X 6 sq. mm + 1 X 6 sq. mm earth wire of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 51 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 52 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 95 Sqmm 3.5 Core size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 53 | Supply only cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core |
| 54 | Providing and fixing rating 250 A, 16 KA,TPMCCB and breaking capacity and pole MCCB with themeteromagnetic release and temeterinal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 55 | M&L for out door type aluminuam bus bar chamber feeder box of cap 300 Amp , 3 phase, 4 wire, 415 Volts of size 90 x 60 x 45 cm including incommer MCCB 250 Amp 4 Pole, 36 KA of make Havells/ Siemens/ Schneider ,The panel made out of 3.15 mm CRCA Sheet duly painted with two coats of synthetic enameld paint over a red oxide primer and fixed and supported with anlge iron grouted in PCC 1:2:4 upto 0.60 mtr high from ground level and 0.40 M below the ground level all as directed by Engr-In-Charge. Note : Contractor is responsible to produce drawing and take approval before placing order. |
| 56 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 57 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 58 | All as per item No 57 above but for one 3 pin 5 Amp socket out let controlled by one switch same board. |
| 59 | All as per item No 57 above but for one 3 pin 5 Amp socket out let controlled by one switch Independent Board board. |
| 60 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required. |
| 61 | Supplying and fixing 5/6 A modular switch including connections but excluding modular plate etc. as required. |
| 62 | Supplying and fixing 15/16 A modular switch including connections but excluding modular plate etc. as required. |
| 63 | Supplying and fixing 3 pin 5/6 A modular socket including connections but excluding modular plate etc. as required. |
| 64 | Supplying and fixing 6 pin 15/16 A modular socket including connections but excluding modular plate etc. as required. |
| 65 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 66 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 67 | Supply & Fix LED 20 Watt Batten light (System lumen efficacy ≥120 85%, Operating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Themeteral management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 68 | Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is nometerally used where 3 phase outlets are required.) |
| 69 | Providing and fixing rating 100 A, 30 KA,FPMCCB and breaking capacity and pole MCCB with themeteromagnetic release and temeterinal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 70 | Supplying and fixing following way, single pole and neutral, 12 way, double door , sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 71 | Wiring for circuit/ submain wiring along with earth wire with the 2 X 6 sq. mm + 1 X 6 sq. mm earth wire of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 72 | Supplying and fixing 5 A to 32 A rating, Single Pole 240 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 73 | Supply and fixing 240V, 30 mA double pole RCBO, cap 63 Amp, in the MCB DB Complete with connection testing and commissioning complete all as specified. |
| 74 | Brush Less Direct Current (BLDC) Fan without RemoteSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 °C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required for 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 75 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 76 | PART -III- PROVN OF ALUMINIUM DOORS, WOODEN DOORS AND FLOOR TILES FOR IT SECTION OF MTTI AF STN AVADI UNDER GE AVADI |
| 77 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 sq.m but n exc 4 sq.m each all as specified and directed. |
| 78 | S&F for second class hard wood plain, solid, straight, chowkats and frames, wrought framed rebated on the solid, rounded or chamfered put together with glue pinned complete all as specified and as directed . |
| 79 | Taking down chowkhats or frames with shutters and (without taking off shutters from frames) n.exc 1.5 sq.m each all as specified and directed. |
| 80 | S&F 2nd class hard wood 35 mm thick plain, framed,panelled shutters(any number ofpanels), withpanels of timberflat on both sides (feather edged), orof veneered particleboard mediumdensity, woodparticle board withcommercial faceveneers: suppliedand fitted to chowkats complete all as specified and as directed. |
| 81 | S & F powder coated anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc complete all as specified. |
| 82 | S&F Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified. |
| 83 | S & F anodised aluminium window and ventilator shutters,side hung type without sash,aluminium section weighing 0.55 kg/m including necssary joining cleats,glazing clips,ruber packing,anodised aluminium snap beading, screws anodised aluminium fittings such as peg stays 150 mm long (1 Nos) hinges type B-21 100 mm long (2 Nos) suitable handle (1 Nos) complete all as specified |
| 84 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge. |
| 85 | S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc 0.5 sqm in each pane all as specified and directed. |
| 86 | S&F 4 mm thick figured glass, pin head type and glazing with oil putty in square not exc 0.50 sqm in each pane complete all as specified and directed. |
| 87 | S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 88 | S&F in repair Aluminium (Die cast) body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specifed and directed. |
| 89 | M&L Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed all as specifed and directed. |
| 90 | M & L in repair for 18/19mm thick prelaminated particle board interior grade prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with scruwes to timber frame work for cub board shutter.etc all as specified and as directed by Engr-in-charge. |
| 91 | S&F solid PVC door frame of size 50mmx47mm made out of 5mm thick plain colour PVC sheet reinforced with 19mm thick MS square tube of 19 gauge mitre cut at two corners and joined by inserting two Nos of 150mm long brackets of 15mmx15mm MS square tube inside the 19mm MS square tube and suitably screwed complete all as specified and as directed. |
| 92 | Supply & fixing factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for style and plain colour PVC sheets for top rail & bottom rail Paneling plain colour PVC sheet to be fitted in MS frame welded/sealed to the stile & rails with suitable PVC sheet beading as per specification & shown on drawing in SSR Pt II of 2010 incl pvc hinges 100 mm size – 3 Nos for each shutter complete all as specified. |
| 93 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. complete all as specified and directed. |
| 94 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick premium quality conforming to relevant IS (square/ rectangular) area of each tile exc 0.06 sqm but n exc 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 95 | M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surfaces of tile over and including 10 mm thick backing coat in cement mortar 1:4 complete all as specified and directed. |
| 96 | M&L for vitrified ceramic tiles (light shade)10 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors etc. set and jointed in neat cement slurry and including 15 mm thick screed bed or bedding layer in cement mortar 1:6 including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed. |
| 97 | M&L for vitrified ceramic tiles (light shade)10 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in skirting, dado etc. set and jointed in neat cement slurry and including 10 mm thick rendering in cement mortar (1:4) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed. |
| 98 | Taking up or down steel tubing and connections, including removal to store etc all as directed for 20/25mm bore all as specified and as directed. |
| 99 | Supplying and laying 16 mm dia of CPVC pipes SDR 13.5 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 100 | Supplying and laying 20 mm dia of CPVC pipes SDR 13.5 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 101 | M&L for Demolition Cement concrete concrete (unreinforced concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 102 | M & L for PCC(1:4:8) type D-2 (40 mm graded aggregate) as in foundation, filling & Mass concrete as directed by Engr-in Charge |
| 103 | S&F in repairs water closet (squatt pattern) of vitreous china squatting pan of pattern \\"ORRISA\\" pattern size 580 x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe anti syphonic pipe etc complete including trap set in and including necessary lean cement concrete complete all as specified and directed. |
| 104 | S&F of PVC low level flushing cistern 10 Ltr capacity, valveless syphonic action type complete with inlet, ball valve, float valve, bends brackets, rawl plug, brass screws handle etc complete having BIS description mark with IS-2731 with and including suitable size of MS brackets, plug, screw all as required incl taking down existing high level/low level flushing cistern any type disconnecting pipes and jointing with new one etc, and making good the floors/walls as per existing floor finish/wall finish including 32 mm bore PVC flush pipe and jointing with water closet of any type all as specified and directed. |
| 105 | S&F Vitreous China wash basin, flat back, size 600x480mm white, excluding taps, waste, chain and plug and rcelain stopper but including brackets complete all as specified and directed. |
| 106 | S&F fancy type, CP, pillar taps screwed down high pressure with or without hot or cold lettered with long screwerd shanks and fly nuts suitable for 15mm bore iron pipes complete all as specified. |
| 107 | S&F Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) complete all as specified. |
| 108 | S&F in repair 15 mm bore PVC connection 600 mm long with two brass chromium plated brass nuts and PVC washers complete all as specified and directed. |
| 109 | S&F 15 mm bore chromium plated bib tap fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 110 | S&F angle , stop valve 15 mm bore, chromium plated, fancy type, with wall flange, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 111 | S&F Soap dish, CP, fixed to plugs with chromium plated brass screws complete all as specified and directed |
| 112 | S&F 600 mm x 450 mm beveled edge mirror of selected quality glass 5.5mm thick mounted on 6 mm thick AC building board or commercial plywood & fixed with wooden plugs with chromium plated brass screws and washer and aluminum beading complete all as directed by Engr-in-Charge. Make:COMMANDER PATTERN / (MANGOLD)/ JASMINE/ GOLDEN FISH or equivalent as approved by GE. |
| 113 | S&F sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 114 | Taking down cement plaster on brick or stone masonry surfaces of walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 115 | M&L for 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 (finished even and fair) , complete complete all as specified and directed. |
| 116 | M&L for two coats of oil bound distemper over a coat of priming coat on newly prepared wall surfaces,including 1 mm thick layer of wall care putty (Birla white or equivalent) all as specified and directed.. |
| 117 | S & F in repairs Aluminium tower bolt 150 mm size complete all as specified and directed. |
| 118 | S & F in repairs Aluminium handles, cast type, anodised handle 150 mm cast type anodized all as specified |
| 119 | S&F SS Butt hinges, heavy weight, cold rolled mild steel, and fixedbright polished and fixed, 100mm size fixed with screws all as specified and as directed. |
| 120 | S&F in repairs 250 mm long Aluminium sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed with screws and as directed. |
| 121 | S&F in repairs 150 mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor all as specified and directed. |
| 122 | Demolition and breaking up old broken , PVC (SWR) , Cast Iron, AC, SWG soil waste and vent pipe of 75/110 mm bore including accessories set in cement mortar and removing rubbish from site as directed by Engineer-in-Charge complete all as specified and directed. |
| 123 | S & F PVC (SWR) pipe 110 mm bore drain pipe single socketed in any length with rubber ring joint fixed to wall (ISI Marked) all as specified and as directed. |
| 124 | S&F PVC ( SWR ) bends 110 mm bore all as specified and directed. |
| 125 | S & F PVC (SWR) pipe 75mm bore single socketed in any length with rubber ring joint fixed to wall (ISI Marked) all as specified and as directed. |
| 126 | S&F PVC ( SWR ) bends 75 mm bore all as specified and directed. |
| 127 | M&L preparation of new wood or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender