Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #58529370

Tender For Provn Of Certain Work Services For 6 Afh, Booster Pump At Bldg No. P-7, Cemented Earth Pit Chamber With Protective Cover (Qty-25, Painted Red) And With Identification Display Marker At Afac Under Age (I) (Af) Coimbatore.

Issued by Statutory Bodies & Commissions/Committees · Coimbatore, Tamil Nadu
Tender Value
8.20 Lakhs
Estimated cost
Bid Submission
07 Dec 2026
20 days left
EMD
16400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Coimbatore → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Certain Work Services For 6 Afh, Booster Pump At Bldg No. P-7, Cemented Earth Pit Chamber With Protective Cover (Qty-25, Painted Red) And With Identification Display Marker At Afac Under Age (I) (Af) Coimbatore.

BOQ

Name of Work:- PROVN OF CERTAIN WORK SERVICES FOR 6 AFH, BOOSTER PUMP AT BLDG No. P-7, CEMENTED EARTH PIT CHAMBER WITH PROTECTIVE COVER (QTY-25, PAINTED RED) AND WITH IDENTIFICATION DISPLAY MARKER AT AFAC UNDER AGE (I) (AF) COIMBATORE.
Sl. No. Item Description
1M&Lpreliminated particle board 12 mm thick interior grade , preliminated both side lamination fixed with screw or cleats or beadings to aluminium frames/ MS frames.
2S & F sheet glass, ordinary quality, in squares exc 0.5 sqm each pane of 4.8 mm thickness all as specified and directed
3S & F powder coated (min thicknesss of powder coating 50micron) aluminium frame for doors, window, ventilators/ partitions with one or more rebates including jointing cleats for fixing etc complete all as spefied and directed.
4S & F powder coating of any colour (Thickness or powder coating not less than 50 micron) aluminium door shutters, aluminium section weighing more than 2.4 Kg/m including, necessary jointing, cleats, glazing clips, ruber neoprene packing handles 2 Nos in each door, hinges as specified,stopper anodised aluminium snap beading screws etc complete all as specified
5S & F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed all as specified and directed
6Material and labour 15 mm thick cement plaster in CM 1:4 for wall finished even & smooth without using extra cement.
7Material and labour Two coats of Oil bound distemper over a coat of alkali resistant primer on walls, pillasters, cornices, etc., on newly plastered walls including preparation of surfaces with 1-3mm wall care putty all as specified and as directed.
8Supply and install hi wall split units of capacity 1.5 TR inverter type indoor/outdoor complete with cordless remote control unit and inbuilt air ioniser and plasma filter with better indoor air quality with star rating minimum 3 to 5 star rating EER 3.2 with outdoor unit mounting unit fitted in any height/location all as directed
9Supply and fix pre wired powerunit with 20 amps mimi MCB and plug top for AC including taking down unserviceable socket all as directed
10Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc and cutting chases for concealed wiring,etc and making good, cutting not exc 10 cm girth
11M&L for concealed/surface Sub main wiring by making recess in wall/surface complete with 2 runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including20 mm or higher dia non metallic rigid PVC conduit and conduit accessories suface/concealed in wall/Ceiling etc from Main DB to MCB DB/AC switch all as specified and as directed by engr - in- charge. Note :- 2 runs of 4 sqmm, + 1 run of 4 sqmm (Earth Cotinuity conductor) and 1 run of PVC conduit shall be measured as one unit length.
12Supply and fix copper tube 3/8\\" or 5/8\\" in repairs with nitrile rubber insulation .
13Supply and fix copper tube 1/4\\" or 1/2\\" in repairs with nitrile rubber insulation.
14Supply and fix outdoor unit mounting stand with self support anchor bolts suitable for mount the 1.5 Ton outdoor unit all as directed
15Supply and fix pressure booter pump 1 HP with standered accessaries such as presure limit switch, Pressure tank 20/25 ltrs, inlet/outlet connection brass adopter, including cutting of delivery line near service tank of bulding and coneect the delivery line to input of pump, out put of pump connect delivery line of building with CPVC pipe of 25 mm dia with required fittings at site, necessary electric connection of FRLS 1.5 Sq mm copper conductor three runs from DB to pump in casing caping/conuit of size 20 mm and provide control switch of 2 pole MCB with sheet metel enclosure, testing the pump after complte the plumbing/electrical work all as directed. Make - Crompton, Havells, Texmo, Kirloskar, KSB
16M & L for earth pit Chamber in PCC 1:3:6, type C1 using 20mm graded stone aggregate and 40mm thick cover in RCC 1:2:4, type B1 using 20mm graded stone aggregate and reinforced with 8mm dia TMT bars at 150mm c/c on both ways, with flush type handle with 16mm dia round bars all as shown in electrical plate No. 3 of SSR Part-I and including necessary excavation and earth work in any type of soil, removal and refilling of soil and two coat of syntahtic enamel panit red colour in chamber and cover over a coat of primer with preparation unpainted surfaces, marking on earth pit covers with two inch height letters in white colour paint all as specified or indicated. Note (i) PCC chamber shall be provided 50cm away from the plinth of building. (ii) Any damage in existing items during the time of excavation rectify/replace the same without any extracost. (iii) The cost of taking down the old pit covers deamed to be included in quated rate .
17Supply and fix earth continuity conductor or main earth lead fixed to wall on battern/recess/chases or buried in ground or drawn through conduit/pipe/porceline insulators or any other indicated situation for 25 Sq mm single core copper conductor XLPE insulated unarmoured cable all as directed
18M&L for dismantling / cutting of existing road / path / hard standing cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) suitable for laying earth lead any type any dia under the road / path / hard standing complete.
19Material and labour for PCC (1:2:4) type B-2 (using 40 mm graded crushed stone aggregate) for making good the disturbed surface of road/path/hard standing by using cement contrete mortar 1:2:4 type B1, using 40 mm graded stone aggregate 0.45 mtr wide and 0.15 mtr thick complete all as specified and directed. including demolition of old PCC and removing the debris from site complete all as specified and as directed at site by the Engr-in-Charge.
20Test point terminal block made of gun metel or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 Nos 8mm dia 25 mm long hex head screw all as directed
21Supply and laying PVC non metalic conduit including tees, bends, elbows, reducers, and fixing accessaries etc for earth continuity cable of size 20 mm dia all as directed
22M&L for framed brackets of angles or tees with web and flanges cut into shape, drilled/welded, screws, rivits and plates as per required size at site with handles etc in mild steel plate and angles for making earth pit indicator as directed by engr in charge including two coat of paint over a coat of red oxide all as directed
23Supply and fix PVC rectangular box with hinged door cover suitable for fixing the test point of size 155x100x95/100 mm all as directed Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58529370
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 8.20 Lakhs
LAST DATE 07-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Certain Work Services For 6 Afh, Booster Pump At Bldg No. P-7, Cemented Earth Pit Chamber With Protective Cover (Qty-25, Painted Red) And With Identification Display Marker At Afac Under Age (I) (Af) Coimbatore.
Basic Detail
Tender No 8228_E8
Bidding Type Tender
Location
City Coimbatore
State Tamil Nadu
Key Dates
Publish Date 14 Nov 2026
Submission Date 07 Dec 2026
Open Date 10 Dec 2026
Finance
Tender Value 8.20 Lakhs
Tender Fee 500
EMD 16400
Exemption Available
Document List
614d34d9-ae22-4e5d-b63b-7c62225f7629.html
BOQ_896039.xls
General_pages_.pdf
Particular_specifications_.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Dec 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

614d34d9-ae22-4e5d-b63b-7c62225f7629.html

xls

BOQ_896039.xls

pdf

General_pages_.pdf

pdf

Particular_specifications_.pdf

pdf

Tendernotice_1.pdf

Disclaimer