Educational and Research Institute Boards / Undertakings / PSU Closing in 15 days TDR #58527818

Tender For Facility Maintenance Works In Tbi Room -2Nd Floor-Central Computer Centre (Ccc)

Issued by Boards / Undertakings / PSU · Kozhikode, Kerala
Tender Value
9.15 Lakhs
Estimated cost
Bid Submission
04 Dec 2026
15 days left
EMD
18300
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kozhikode → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Facility Maintenance Works In Tbi Room -2Nd Floor-Central Computer Centre (Ccc)

BOQ

Name of Work:- Facility maintenance works in TBI Room -2nd Floor-Central Computer Centre (CCC)
Sl. No. Item Description
1CLADDING WORK
2Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with:
3Decorative veneer facings of approved manufacture
4WOOD AND P. V. C. WORK
5Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete :
6125x64x1.90 mm
7Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete.
8Size 40 mm
9Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge.
10Providing and fixing self-adhesive or heat-applied decorative vinyl sheet of approved make, shade, and pattern on existing/new door surfaces (glass door/aluminium door), including surface preparation, cleaning, application of adhesive (if required), edge trimming, and finishing complete. The vinyl sheet shall be minimum 1.0 mm thick, scratch-resistant, waterproof, and suitable for vertical door surface application. The rate includes labour, tools, adhesives, and all materials required to complete the work under the supervision of the Engineer-in-Charge.
11Providing and fixing 18 mm thick marine plywood full gurjan or equivalent confirming to IS:710 for cupboards, shelves, partition, draweres, table top etc. including necessary scres etc. complete.
12STEEL WORK
13Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
14GI Tubular TATA or equvalent
15Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :
164.0 mm thick glass panes (weights not less than 10 kg/ sqm)
17FLOORING
18Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.
19Size of Tile 600x600 mm
20Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).
21Size of Tile 600x600 mm
22ROOFING
23Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
2412.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
25Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately).
26Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately).
27Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
28Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
29Ridges plain (500- 600mm)
30Providing square type UPVC gutter with necessary clamps, bolts, nuts, and specials such as nozzles, sockets, stoppers, etc., including cost and conveyance of all materials and labour charges etc. complete as per the instructions of the dept. officers
31200mm or equivalent Square type UPVC gutters
32FINISHING
33Finishing walls with textured exterior paint of required shade:
34New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
35Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
36On steel work
37Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
38Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
39Two coats
40Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content.
41With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
42Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
43Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
44One or more coats on old work
45Finishing walls with water proofing cement paint of required shade :
46Old work (one or more coats @ 2.20 kg/10 sqm) complete.
47REPAIRS TO BUILDING
48Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.
49Dismantling and Demolishing
50Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking anywhere in the campus :
51Thickness above 25 mm up to 40 mm
52Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground anywhere in the campus
53Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material anywhere in the campus directed by Engineer-in-charge.
54Dismantling tile work in floors of thickness 10 mm to 25 mm, covering the dismantled area with lightweight wooden panels laid in cement mortar, and stacking of serviceable materials anywhere within the campus as directed by the Engineer-in-Charge.
55Dismantling glass panes, with putty and nails or with fixed with beading including stacking of serviceable materials and disposal of unserviceable materials anywhere in campus.
56WATER SUPPLY
57Providing and fixing Polyvinyl Chloride (PVC) pipes, including all PVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
5850 mm nominal dia Pipes (10kg/cm2)
59110 mm nominal dia Pipes (4kg/cm2)
60ALUMINIUM WORK
61Providing and fxing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing I paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
62For fixed portion
63Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
64Powder coated aluminium (minimum thickness of powder coating 50 micron)
65For shutters of doors, windows & ventilators including providing and fxing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
66Powder coated aluminium (minimum thickness of powder coating 50 micron)
67Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
68With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
69Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer- in-ch a rge
70Powder coated minimum thickness 50 micron aluminium
71Providing and fixing 4mm thick Aluminium Partition Panels, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.
724 mm thick aluminium partion panels
73Providing and fixing sun control film on glass including cost and conveyance of all materials and labour charges etc. complete.
74White Sun Control film with 5% wastage
75WATER PROOFING
76Providing Fibre lamination works to the RCC structure using resin fibre glass and chemicals after washing the surface roughly cleaned and dry fill in the cracks with suitable putty, first apply the resin to the surface well spread and pressing, applying a second layer of resin to smooth finish for forming the whole to a solid mass including cost and conveyance of all materials and labour charges etc. complete as per the instructions of the dept. officers Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58527818
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 9.15 Lakhs
LAST DATE 04-12-2026
Authority
Authority Name National Institute Of Technology
Work Description Tender for Facility Maintenance Works In Tbi Room -2Nd Floor-Central Computer Centre (Ccc)
Basic Detail
Tender No Engg/D1/JE 9/543/2026-27
Bidding Type Tender
Location
City Kozhikode
State Kerala
Key Dates
Publish Date 13 Nov 2026
Submission Date 04 Dec 2026
Open Date 07 Dec 2026
Finance
Tender Value 9.15 Lakhs
Tender Fee Ref. Documents
EMD 18300
Exemption Available
Document List
5e196950-b92b-47ce-9aaa-6d112645d81c.html
BOQ_981852.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Dec 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

5e196950-b92b-47ce-9aaa-6d112645d81c.html

xls

BOQ_981852.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender