Tender For Repair/Replacement Of Existing electrical installation Wiring, Accessories And Upgradation Of Switchgear In The Office In Sco 36-46,Sector-17-E, Chandigarh.(Additional Works).
Tender Value
17.97 Lakhs
Estimated cost
Bid Submission
19 Nov 2026
2 days left
EMD
35960
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Replacement Of Existing electrical installation Wiring, Accessories And Upgradation Of Switchgear In The Office In Sco 36-46,Sector-17-E, Chandigarh.(Additional Works).
BOQ
| Sl. No. | Item Description |
| 1 | DSR Item No. 1.10Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 2 | Group-C |
| 3 | DSR Item No. 1.15Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required. |
| 4 | Group-C |
| 5 | DSR Item No. 1.17Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 6 | 3 x 1.5 sq. mm |
| 7 | 3 x 2.5 sq. mm |
| 8 | 3 x 6 sq. mm |
| 9 | DSR ITEM NO. 8.7LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, (As per Complete Item No. 4 of the DNIT). |
| 10 | 36 watt |
| 11 | Supply and erection of Change over switch with Enclosure of following ratings installed in existing switch board with nuts & bolts of requisite size after making holes etc. The job includes making all necessary connection with New Change Over switch testing, commissioning & labour required to complete the job. (As per Complete Item No. 5 of the DNIT). |
| 12 | Change Over switch 400 Amp 415 volt 4 pole |
| 13 | Supply and erection of sheet metal cubical pedestal of suitable dimensions made from 50 mm X 50 mm X 6 mm thick M.S angle iron frame, covered with 1.6 mm thick M.S. sheet duly welded on five sides and front side hinged complete with locking arrangement with 4 Nos. switchgear supporting members each of M.S. flat 50 mm X 6 mm thick of suitable length duly welded. (As per Complete Item No. 6 of the DNIT). |
| 14 | Cubical size 900 mm X 600 mm X 350 mm |
| 15 | Supply and laying of XLPE insulated PVC sheathed Aluminium conductor cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid on the existing cable tray/ open duct. The job include the cost of making connections with suitable size of Al. Lugs / thimbles, testing, commissioning etc. as required to the entire satisfaction of Engineer In Charge. The cable should be of KEI / Havells / Polycab / RR Kables / Finolex only. |
| 16 | 400 Sq.mm. 3.5 Core XLPE Armoured Aluminium conductor cable. |
| 17 | S/I/T/C of linear suspended luminaire 4’ long made up of extruded aluminium with PMMA diffuser for standalone and seamless end to end connectivity. The fitting is to be installed on existing surface with the help of two no. suitable length universal suspensions suitable for quick on site adjustment. (As per Complete Item No. 8 of the DNIT). |
| 18 | DSR Item No. 8.16.3LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy ≥120 and <135 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, (As per Complete Item No. 9 of the DNIT). |
| 19 | 250 Watt |
| 20 | 150 Watt |
| 21 | Supply and laying of PVC insulated PVC sheathed Aluminium conductor cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid in existing RCC/ HUME / DWC pipe. The job include the cost of making connections with suitable size of Al. Lugs / thimbles, testing, commissioning etc. as required to the entire satisfaction of Engineer In Charge. The cable should be of KEI / Havells / Polycab / RR Kables / Finolex only. |
| 22 | 10 Sq.mm. 4 Core PVC Armoured Aluminium conductor cable. |
| 23 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required |
| 24 | 63 mm dia (OD-63 mm & ID-51 mm nominal |
| 25 | Supply and Erection of LED Post Top Lantern fittings made of cast aluminium housing with power to be mounted on directly on inbuilt Heat sinks. A UV stabilized PC/PMMA diffuser is provided for Glare Free Lighting,(As per Complete Item No. 12 of the DNIT). |
| 26 | DSR Item no. 8.1LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, (As per Complete Item No. 13 of the DNIT). |
| 27 | 12 -15 watt |
| 28 | DSR item No.1.31Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 29 | DSR item No.1.32Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 30 | Supply, installation, testing and commissioning of 400 Amp, 415 V, 3-phase, 4-wire, 50 Hz Automatic Transfer Switch (ATS), suitable for automatic changeover between mains and DG supply, (As per Complete Item No. 16 of the DNIT). Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysNov 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender