Tender for Remodeling Of Lis Jangal Tehsil Jawali Distt Kangra (H.P.) (Sh:- Providing And Installation Of Centrifugal Pumping Machinery Along With Allied Accessories)
BOQ
| Sl. No. | Item Description |
| 1 | Supply installation, testing & commissioning of horizontal spindle, horizontal/ radial split casing/end suctions (back pull out arrangement)single/double/multistage centrifugal pump suitable for operation, in parallel of recommended make such as Mather and platt/KSB/ Kirloskar/Jyoti/Beaconweir BS&BE OR any other approved make by JSV HP confirming to BIS-1520-1980 with upto date ammendments, read with IS:9137-1978 suitable for lifting clear water for under mentioned characteristics with 2.5% Nickel impellers, dia of priming funnels, casing ring and shaft sleeves, shaft of SS:410/A IS 1431 chromium plated with cast iron casing coupled directly through a flexible coupling on a common MS base plate to squirrel cage induction motor TEFC type energy efficient motor minimum IE2 compliance confirming IS 12615-2018 with up to date ammendmends of standard make such as Kirloskar/BHEL/Crompton/NGEF/GEC/Siemens/ Jyoti/Area Brown Boven/ABB/CGL and suitable for operation on 415 (+) (-)15% Volt, 50 cycles/second 3 phase AC electric supply. The power of electric motor/motors should be at least (+) 10% in excess of the maximum power required by the pump /pumps in the operation range of (+) 10% and (-) 15% of the duty point head. The motor /motors should be as per IS: 325-1978 with upto date amendments read with IS:900-1972 as per direction and satisfaction of engineer in charge within all leads and lift.01 Set with 63.86 LPS discharge and 164.89 mtrs. Total head. |
| 2 | Location of site :- The site is located at a distance of 08 kilometers from Kotla National highway. |
| 3 | The Altitude of place in which :- The Altitude of place is 450 meters above mean sea level. The motor is intended to work. |
| 4 | Type of current. :- AC Three Phsae Supply with frenquency 50 cycle per second. |
| 5 | Rate Voltage :- 415 V volts (+-) 10% |
| 6 | L.W.L in T/-well /Tank :- 510.70 meters |
| 7 | Center line level of Pump :- 510.70 Meters |
| 8 | Discharge level of highest point :- 667.60 Meters |
| 9 | Nos. of pump requried :- 1 No. Pump |
| 10 | Capacity :-63.86 LPS |
| 11 | Total head in meters :- 164.89 Meters |
| 12 | Length of Rising Main :- 990 Mtr |
| 13 | Dia of Rising main :- 400 mm dia MSERW |
| 14 | Nos. of working hours per day :- 20.00 hours |
| 15 | Limit of pump operation. :- (-) 15 % (+) 10% of total head |
| 16 | HP of motor/Drive unit :- Required 240.00 HP of pump at (+) 10% and (-) 15% of total head BHP with following margins/multiplying factor at duty point, whichever is higher (a) upto 2 HP = 1.5 (b) 2 to 5 HP = 1.4 (c) 5 to 10 HP = 1.3 (d) 10 to 20 HP = 1.2 (e) 20 to 100 HP = 1.15 (f) Above 100 HP = 1.10 |
| 17 | Test run :- 8 Hours continueously for 7 days |
| 18 | Providing and fixing of automatic pannel borad of L&T make for mentioned pumping machinery (as per relavent IS/BIS standards) including auto start, auto stop and restart facility single phase preventer, 3 phase indicator timer, relay, selector switch, auto and manually start stop facilty, prevention of of phase reversal imbalance and overload and fixed with compatible starter in sheet enclosure with cabling complete in all respect to deliver results. |
| 19 | Providing and fixing of M-power module of ISI approved brand/make for automation of the pumping machinery including cost 01 No. mobile handset (02 No. Sim cards, 01 for module and 01 for moble phone) and recharge for one complete year and all accessories required for installation and comissioning of M-power module for complete in all respects within all leads and lifts as per direction and satisfaction of engineer in charge. |
| 20 | Providing M.S.Sheet 16-SWG steel fabricated floor mounted closed Almirah type switch board including angle iron post of suitable height and size ISA 65x65x6mm.duly painted comprising and capable of mounting the following accessories with all internal electric connections including following accessories . Note:- The drawing of panel baord shall be subject to be approval of Engineer-in-charge. |
| 21 | Ammeter for A.C.supply, 100mm.circular dial L&T Rishav/Auto Electric/AE/IMP/Havells make of suitable range for above Pumping Set with selector switches conforming to BIS-1248-1983(Latest edition) 1 No. |
| 22 | Voltmeter for A.C.supply. 100mm.circular dial L&T Rishav/Auto electric/AE/Havells make of suitable for above Pumping set with selector switches conforming to BIS-8044-1978 (Latest edition) 1 No. |
| 23 | ICT.Switchhes with HR fuses Kilburn/L&T/Standard/Siemens/Havell's make and having capacity 30% extra operational rating of Motor as per BIS-4064-1978 with uptodate ammendments immediately after the power of the Meter of the HPSEB 1 No. |
| 24 | Busbar chamber of approved make having 3 copper bars of suitable rating for full length equal to width of Board of 3-live phases and one copper bar of half rating of full length for neutral conforming to BIS-8084-1976 and 11353-1985 read with 5578-1985 all latest with uptodate ammendments 1 No. |
| 25 | MC3/MCCB/OCB of suitable capacity of Kilburn/L&T/MEI/Standard/GEC/Havell's make on incoming feeder for Pumping set conforming to BIS-2516-1985 (Latest edition) with neutral linked under voltage release 1 No. |
| 26 | Hour Run Meter of reputed/approved make of four digit capacity conforming to BIS-722(Latest edition) 1 No. |
| 27 | Power factor shunt capacitor conforming to BIS 2834-1986 latest with up to date ammendments (if any) L&T/ BHEL/GEC/Machneil Mager Bajaj make to raise the power factor at site 0.95 of required KVAR according to the HP of motor |
| 28 | Supply of Kirloskar/Kilburn/ Leader make Cast Iron double flanged check type reflux valve/NRV class -ASA -150 one dia more than the dia delivery of pump as per BIS 5312-1984 Part-1 latest with upto date ammendments (if any) complete in all respect within all leads and lifts as per direction and satisfaction of Engineer-in-charge. |
| 29 | Supply of Kirloskar/Kilburn/ Leader make Cast steel double flanged sluice valve class -ASA -150 one dia more than the dia delivery of pump as per BIS 5312-1984 Part-1 latest with upto date ammendments (if any) complete in all respect within all leads and lifts as per direction and satisfaction of Engineer-in-charge. |
| 30 | Supply of PVC insulated jointless, flat water proof copper cable of Finolex/Polycab conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles ,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. |
| 31 | On supply side of 3.5 core coper cable 300.00 Sq. mm ( From HPSEB Meter to Starter & Switch) |
| 32 | On motor side 3.5 core cable 185.00 sq. mm ( From Switch & Starter to Motor) pump installed in the bore. |
| 33 | Supply of standarad make 100mm dia circula pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments (if any) complete in all respects within all leads and lifts as per direction and satisfaction of engineer in charge. |
| 34 | Providing and laying double loop earthing with copper plate 600x600x3 mm thick electrode complete with material such as char coal, common salt, G.L. pipes, thimblesnuts, bolts, digging of pits, G.1. wiring and 25x 5 manus copper strips conforming to BIS 3043-1987 latest with up to date ammendments (if any) complete in all respects within all leads and lifts as per direction and satisfaction of engineer in charge |
| 35 | Providing and laying of G.I./MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set . The pipe shall conform to relevant BIS codes & capable of with standing the feild test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers/ reducers, flanges, rubber gaskets 3 mm thick, nuts & bolts and any other fitting required at site and complete in all respects within all leads and lifts as per direction and satisfaction of engineer in charge. |
| 36 | Common header required data (MG) (PE) (to be specified by the tenderer) |
| 37 | CCTV survellience of the scheme Providing and fixing of 8 channel NVR 5 MP to 12 MP CCTV camera 01 No, Providing and fixing of 5 MP ip Ballet camera 04 No., Providing and fixing of 4 channel POE Switch 01 No, Providing and fixing of Networking wire 100 mtrs., Providing and fixing of 1 TB Hard disk 01 No., Providing and fixing of 2 U rack 01 No., Providing and fixing of RJ Connector 5 No. & Providing and fixing of HDMI cable as per requirement within in all leads and lifts and to the entire satisfaction of Engineer in Charge |
| 38 | Erection of all equipments including cost of tees, bends, tapers and any other fhtings to make the pumping machinery fully functional as per conditions and as per directions of the Engineer-in-Charge Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysNov 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender