Tender For Repairs, Replacement To Roof Covering, Roof Treatment, Ceiling, Sunken Repair To Various Otm And Md Accn As Part Of Dry Restoration And Ecofriendly Asset Management (Dream) Incl Certain Misc Works At Mic&S Ahilyanagar Under Ge(S) Ahilyanag
Tender Overview
Project Description
Tender for Repairs, Replacement To Roof Covering, Roof Treatment, Ceiling, Sunken Repair To Various Otm And Md Accn As Part Of Dry Restoration And Ecofriendly Asset Management (Dream) Incl Certain Misc Works At Mic&S Ahilyanagar Under Ge(S) Ahilyanagar
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 2 | S&F prepainted galvalume aluminium zinc coated galvanised iron based corrugated steel sheets 0.5 mm thick of any colour, AZ150, having tensile strength 550 MPA as in roof covering or ridges with side lap and end laps, hips and straight flashing fixed with self tapping screws (length & girth as fixed) complete all as specified and as directed. Note:- Colour & Pattern to be approved by Engineer-in-Charge. |
| 3 | S&F prepainted galvalume aluminium zinc coated galvanised iron based corrugated Mangalore tile profile sheeting 0.5 mm thick of any colour, AZ150 having tensile strength 550 MPA as in roof covering or ridges with side lap and end laps, hips and straight flashing fixed with self tapping screws (length & girth as fixed) complete all as specified and as directed. Note:- Colour & Pattern to be approved by Engineer-in-Charge. |
| 4 | S&F Pre-painted galvalume aluminium zinc coated galvanised Iron based Plain steel sheets, 0.5mm thick of any colour, AZ150, with side lap and end lap having tensile strength 550 MPA as in ridges, hips, valley gutters, drip and straight flashing fixed with self tapping screws (length & girth as fixed) complete all as specified and as directed. |
| 5 | Dismantling asbestos cement sheet (corrugated or semi corrugated etc) including ridges in large patches as in roof covering complete all as specified and as directed.Note:- Dismantling existing wind tie for taking down of sheets and refixing the same where required shall deemed to be included in the unit rate quoted. |
| 6 | M&L for 6mm thick asbestos cement, corrugated or semi corrugated sheets in roof, wall cladding, fixed with 'L' type or 'J' type or cranked hook bolts, washer etc complete all as specified and as directed. |
| 7 | Re-Fixing of old Asbestos cement 6mm thick, corrugated or semi corrugated sheets in roofs, walls etc, fixed with L or J type or cranked hook bolts complete all as specified and as directed |
| 8 | S&F for 6mm thick Asbestos cement two piece serrated ridge for corrugated or semi corrugated sheets, fixed with L or J type or cranked hook bolts complete all as specified and as directed |
| 9 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 10 | S&F rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe-410W grade E-250 quality-B with and including one shop coat of zinc chrome primer including preparation of new surfaces complete all as specified and as directed. |
| 11 | M&L for preparation of new steel surface of any description over 10cm in width or girth and applying two coats of synthetic enamel paint of any shade over a coat of red oxide primer complete all as specified and directed. |
| 12 | Dismantling battens for tiles, shingles etc, of any size including tilting fillets spaced not exc 15 cm complete all as specified and directed. |
| 13 | M&L clean sawn batten at spacing 15cm centre of second class hardwood of exc 5 & n.exc 15 Sqcm section area complete all as specified and directed. |
| 14 | M&L for refixing old clean sawn batten at spacing 15cm centre of second class hardwood of exc 5 & n.exc 15 Sqcm section area complete all as specified and directed. |
| 15 | Dismantling of mangalore pattern or similar tiles in roofing complete all as specified and directed. |
| 16 | M&L for Roof tiles mangalore pattern, interlocking at side joint laid dry complete all as specified and directed. |
| 17 | Refixing of old Roof tiles mangalore pattern, interlocking at side joint laid dry complete all as specified and directed. |
| 18 | M&L for Ridge or hip tiles to suit Mangalore pattern or roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and directed. |
| 19 | M&L for refixing Ridge or hip tiles to suit Mangalore pattern or roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and directed. |
| 20 | M&L for Tiles or slate battens, any size and spacing, prepared and treated all over (measured overall on one side only), spaces not deducted) with creosote complete all as specified and directed. |
| 21 | Disconnecting existing tanks exc 250 ltrs and n.exc 500 ltrs capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc and writing date of cleaning on tank complete all as specified and directed. |
| 22 | Disconnecting existing tanks exc 500 ltrs and n.exc 1000 ltrs capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc and writing date of cleaning on tank complete all as specified and directed. |
| 23 | M&L for Cleaning existing surface properly with steel wire brushes by removal of all loose particle to ensure clean, smooth and dry surface and laying 25mm thick plain cemnet concrete type B-0,(1:2:4) using 12.5mm graded stone aggregate complete all a specified & directed. |
| 24 | M&L for Cleaning existing surface properly with steel wire brushes by removal of all loose particle to ensure clean, smooth and dry surface and laying 100mm thick plain cemnet concrete type B-1,(1:2:4) using 20mm graded stone aggregate complete all a specified & directed. |
| 25 | M&L in repairs, for water proofing treatment to RCC roof slab, including parapet, comprising with the following treatment/specification from bottom to top:-(i) Taking out old roof treatment and roughening the old concrete slab by picking, sweeping clean and washing down with water to remove dust etc and disposal of rubbish n exceeding 100 mtr distance from starting point.(ii) Screed bed or bedding layer of 10 mm thick cement mortar 1:4 with mixing of WPC as per manufacturers instructions and surface finished even and smooth without using extra cement after applying a coat of cement slurry @ 3kg/sqm. (iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.30 ltr /Sqm conforming to IS:3384-1986.(iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) shall be applied over bituminous primer as specified above by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. |
| 26 | M&L for Applying two coats of aluminium paint over the APP modified membrane @ 0.11Kg/sqm complete all as specified and as directed by Engineer-in-Charge. |
| 27 | Supply and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls complete all as specified & directed. |
| 28 | M & L for Water proofing treatment to floor & vertical surfaces of sunken portion complete comprising the following (floor area of WC/Bath not exceeding 1.5 sqm) :- (a) Demolition of floor and lime concrete etc. remove all loose particles along with existing water proofing treatment (any no. of layers) with wire brushes and cleaning the surfaces with water.(b) Brushing cement slurry with 1.2 kg of cement per square meter duly blended with & including water proofing compound.(c) 15mm thick (Average thickness) plaster in cement mortar (1:4) mixed with WP compound on sunken surface including walls. The corner of sunken portion shall be rounded in concave shape and adequate slope shall be made during plastering to accommodate sump pipe and curing the sunken portion with water minimum for 48 Hrs by ponding.(d) Applying self adhesive type APP based polymeric membrane minimum weighing not less than 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non-woven fabric (weight not less than 150 gm/sqm (e) M&L for PCC 1:7:12 for fillin of sunken portion after conceling all membrane and sealing all joints to the entire with broken bats and light weight, and provide hole in the wall and fix 600 mm long 20 mm dia GI spouts light grade, PCC 1:3:6, type C1 (using 20 mm graded stone aggregates) filling complete all as satisfaction of Engineer-in-Charge.Note- The rates include for drilling of the hole RCC @ 1.00 m centre to centre, to a depth to a length of 30 mm and fixing of PVC pipes of dia 15/20 mm laid dry and grouting with cement slurry mixed with can bax 100 chemical with pressure grouting with minimm 3 Kg/Sqm complete all as specified and directed. |
| 29 | M & L for Water proofing treatment to floor & vertical surfaces of sunken portion complete comprising the following (floor area of WC/Bath exceeding 1.5 but not exceeding 3 sqm) :- (a) Demolition of floor and lime concrete etc. remove all loose particles along with existing water proofing treatment (any no. of layers) with wire brushes and cleaning the surfaces with water.(b) Brushing cement slurry with 1.2 kg of cement per square meter duly blended with & including water proofing compound.(c) 15mm thick (Average thickness) plaster in cement mortar (1:4) mixed with WP compound on sunken surface including walls. The corner of sunken portion shall be rounded in concave shape and adequate slope shall be made during plastering to accommodate sump pipe and curing the sunken portion with water minimum for 48 Hrs by ponding.(d) Applying self adhesive type APP based polymeric membrane minimum weighing not less than 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non-woven fabric (weight not less than 150 gm/sqm (e) M&L for PCC 1:7:12 for fillin of sunken portion after conceling all membrane and sealing all joints to the entire with broken bats and light weight, and provide hole in the wall and fix 600 mm long 20 mm dia GI spouts light grade, PCC 1:3:6, type C1 (using 20 mm graded stone aggregates) filling complete all as satisfaction of Engineer-in-Charge.Note- The rates include for drilling of the hole RCC @ 1.00 m centre to centre, to a depth to a length of 30 mm and fixing of PVC pipes of dia 15/20 mm laid dry and grouting with cement slurry mixed with can bax 100 chemical with pressure grouting with minimm 3 Kg/Sqm complete all as specified and directed. |
| 30 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing rubbish off the premises complete all as specified and directed. |
| 31 | M&L for non skid coloured ceramic tiles 7-8mm thick (square or rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 etc complete all as specified & directed.Note: Color and shade shall be as approved by Engineer-in-charge. |
| 32 | M&L for glazed coloured ceramic tiles in vertical surfaces as dado of size 450x300x6-7mm/300mmx600mmx6-7mm, thick set and jointed in neat cement and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:3 on other than fair faces of brick work etc complete all as specified & directed.Note: Color, size and shade shall be as approved by Engineer-in-charge. |
| 33 | S&F in repairs, vitreous china wash down water closet (pedestal pattern) white, including connection to drain (or outgoing pipe) and flushing pipe, anti syphonage pipe, trap set and including white or black seat cover for pedestal pan with mild steel chromium plated aluminium hinging device, fixed to pan with suitable screws, etc. complete all as specified and as directed.Make: Cat No. S1053102 of CERA or equivalent model of makes specified. |
| 34 | S&F in repair Vitreous China, Squatting pan Orissa pattern size 580 x 440mm, white with integral foot rests (excluding flushing cistern and flush pipe) with Vitreous China ‘P’ or ‘S’ trap, front or back inlet including connection to trap and to flushing pipe, anti syphonage pipe, including PCC (1:2:4) type B-1 for fixing of WC and making good the floor to match the existing complete all as specified and as directed.Make: Cat No. S3010102 of CERA or equivalent model of makes specified. |
| 35 | S&F in repairs 10 ltr capacity PVC valve-less, syphonic action type flushing cistern, low level, white with inlet ball valve and handle including brackets complete all as specified and as directed.Make: Cat No. B1010110 of CERA or equivalent model of makes specified. |
| 36 | S & F in repairs, PVC connections, 15 mm size with PTMT nuts of length 600 mm complete all as specified and as directed. |
| 37 | S & F in repairs, stop/ angle valves, 15mm dia, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions complete all as specified and as directed.Make: Cat No. F1015201 of CERA or equivalent model of makes specified. |
| 38 | S&F in repairs, Health faucet (ABS Body) suitable for 15 mm dia pipe with 1 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.Make: Cat No. F8030111AB of CERA or equivalent model of makes specified. |
| 39 | S&F in repairs, bib tap 15mm dia, with wall flange and aerator screwed down for pipe or for brass ferrule iron complete all as specified and as directed.Make: Cat No. F1015151 of CERA or equivalent model of makes specified. |
| 40 | S&F in repairs, two way bib tap 15mm dia, with wall flange and aerator screwed down for iron pipe or for brass ferrule complete all as specified and as directed.Make : Cat No. F1015161 of CERA or equivalent model of makes specified. |
| 41 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n. exc 1.5 sqm each and making good the disturbed surface in CM 1:3 complete all as specified and directed. |
| 42 | M&L for factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ ceosetory windows & other frames/ chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension grade), Calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N (Edge), minimum compressive strength of 58 N/Sqmm, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardantand fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per specified and as directed. Note: (i) Minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable for WPC solid door/window frames. Variation in profile dimensions on plus side shall be acceptable without any extra cost to the department.(ii) M.S. hold fast/ lugs or SS dash fasteners shall be paid separately. |
| 43 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid decorative flush/panel door shutter of 30 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. |
| 44 | S&F aluminum anodized barrel tower bolt of extruded section size of bolt 150mm as specified and directed. |
| 45 | S & F 200 mm long aluminum alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy complete all as specified and as directed. |
| 46 | S&F 100 mm long SS butt hinges, medium weight, cold rolled and fixed with screws/welded complete all as specified and directed. |
| 47 | S&F 150mm size aluminium alloy handles, fabricated type extruded section, ISI marked complete all as specified and as directed. |
| 48 | M&L for Cutting out cracks to V-section in existing roofs or terracing, cleaing out, and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 ( by weight) complete all as specified & directed. |
| 49 | Demolition of cement concrete (unreinforced) of roofs, floors (other than ground floors), beam, staircases, lannding, chajjas and similar suspended work complete all as specified & directed. |
| 50 | S&F in position rotational moulded polyethylene triple layered water storage tanks of any color with 500 lts capacity (cylinderical vertical with closed top) hoisted and fixed in position with and including ball valve 20 mm bore high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight not less than 210 grams) and dismantling of exisitng tank complete all as specified and directed. |
| 51 | S&F in position rotational moulded polyethylene triple layered water storage tanks of any color with 1000 lts capacity (cylinderical vertical with closed top) hoisted and fixed in position with and including ball valve 20 mm bore high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight not less than 210 grams) and dismantling of exisitng tank complete all as specified and directed. |
| 52 | S&F in repairs, rotational moulded polyethylene water storage tanks colour white (cylindrical vertical with closed top), 2000 litres capacity, tripple layered, hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to iron pipe and connecting all as specified and as directed. |
| 53 | S&F in repair cover/lid for any type PVC water storage tank covers suitable for 500/1000 litre capacity all as specified and as directed |
| 54 | Taking up or down 15 mm bore dia GI steel tubing and connections complete all as specified and as directed. |
| 55 | Taking up or down 20 mm bore dia GI steel tubing and connections complete all as specified and as directed. |
| 56 | Taking up or down 25 mm bore dia GI steel tubing and connections complete all as specified and as directed. |
| 57 | M&L for Refixing old 15mm bore GI water tubes in short lengths with all fittings and fixed complete to walls (concealed) ceilings or laid in floors complete all as specified and directed |
| 58 | M&L for Refixing old 20mm bore GI water tubes in short lengths with all fittings and fixed complete to walls (concealed) ceilings or laid in floors complete all as specified and directed |
| 59 | M&L for Refixing old 25mm bore GI water tubes in short lengths with all fittings and fixed complete to walls (concealed) ceilings or laid in floors complete all as specified and directed |
| 60 | S&F 15mm bore UPVC pipes Sch 40 including fittings, any length with fittings such as socket, elbow, bends, tees, reducer, union, caps plug, nipple etc complete laid in walls/ ceiling or laying in floor trench or fixed to walls complete all as specified and directed. |
| 61 | S&F 20mm bore UPVC pipes Sch 40 including fittings, any length with fittings such as socket, elbow, bends, tees, reducer, union, caps plug, nipple etc complete laid in walls/ ceiling or laying in floor trench or fixed to walls complete all as specified and directed. |
| 62 | M&L for 25 mm bore GI tubing medium grade with all fitting and fixed complete on walls and ceilings or laid in floors etc complete all as specified and as directed. |
| 63 | Dismantling of wall and ceiling boards (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and directed. |
| 64 | S&F laminated Gypsum tile board 8mm thick with textured white colour PVC film on the face side and metalized polyster (MPL) film on rear side in ceiling as per manufacturers instructions of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanized @ 120grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, all as specified and as directed. |
| 65 | Demolition of brick/ block/ stone masonry built in cement mortar or cement lime mortar of any description. |
| 66 | M&L for brickwork with old size fly ash bricks straight or curved on plan with mean radius exc 6m built in CM 1:6 complete all as specified and directed. |
| 67 | Taking down cement or cement lime plaster of any description on brick, block or stone walls etc (at any height) including racking out joints, hacking for key scrubbing down with water etc complete & removing debris outside MD land as directed. |
| 68 | M&L for 15 mm thick rendering in cement mortar 1:4 (using water proofing liquid as per manufacturers instruction) on fair faces of brick masonry surfaces or concrete surfaces, finished even and fair without using extra cement complete all as specified and as directed. |
| 69 | M&L for 15 mm thick rendering in cement mortar 1:4 (using water proofing liquid as per manufacturers instruction) on other than fair faces of brick masonry surfaces or concrete surfaces, finished even and fair without using extra cement complete all as specified and as directed. |
| 70 | M&L for rendering 5 mm thick in cement mortar 1:3 on concrete surfaces as in ceiling finished the surface even & smooth without using extra cement complete all as specified & directed. |
| 71 | M&L for extra over rendering or plastering for work in isolated width or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirtings, drip moulds and similar work n exc 15 cm in width and girth, including cutting to edges, all mitres and stopped ends, etc. complete all as specified and directed |
| 72 | M&L for Preparation of newly plastered ceiling surfaces and applying three coats of white wash complete all as specified |
| 73 | M&L for preparation of new plastered surfaces or previously untreated surface of wall and applying two coats of cement base paint over one coat of alkali resistant primer all as specified and as directed. |
| 74 | M&L for Providing cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate in roof kerbs in lintels upto 1.5 m clear span, cills, steps ; seismic and other similar bands, plinth courses, string courses lacing courses, parapets and railings coping, kneelers, apex stones, bed plates, water throughs and the like including weathering, slightly rounded or chemfered angles and throating complete all as specified and as directed . |
| 75 | Taking down eaves gutters and rain water pipes ( any size or pattern ), including all fittings, heads, shoes, bends swan-necks, etc, including cleaning or refixing or removal from site complete all as specified and as directed. |
| 76 | S&F PVC (SWR) pipes 110mm bore, single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed. |
| 77 | S&F PVC (SWR) bends any radius, 110 mm bore complete all as specified and as directed. |
| 78 | S&F 110 mm dia stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and as directed. |
| 79 | S & F repair of Single pipe of dia 110 mm (4\\") PVC pipe fixing done with Pipe Support Clamping System consists of Rain Water Bracket Set with Pipe Support Channel + U Bolt Rubber Sleeve mounted system running vertically with wall distance 75 mm (3\\") : Pipe Support Clamping made of :1. Rain Water Bracket Set with pipe support channel for 110 mm (4\\") PVC pipe having Wall Distance 75 mm (3\\") made of Low Carbon Hot Roll Gauge Corrected Oil Pickled and Drawn (HROP D) Steel (IS 1079); material size 32 mm width x 3 mm thickness with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result 2000 hrs.2. U bolt Rubber Sleeve mounted are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated.Hotdip Galvanizing: As per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1.Material Quantity for one unit : 1. Rain Water Bracket Set for 110 mm (4\\") PVC dia. pipe with pipe support channel; Wall distance 75 mm (3\\") - 1 Nos. ; 2. U Bolt rubber sleeve mounted for 110 mm (4\\") PVC Pipe Dia. - 1 No.; and 3. Fixing Nail Zn coated of thickness 6.5 mm and length 63 mm (2 1/2\\") - 2 nos.Fixing Details: Pipe Support Clamping Unit to be fixed at every metre distance in the duct as specified in the CE Pune Zone Technical Drawing no. : CEPZ/2023/TD/03.Make: Shaivi or equivalent as approved by GE. |
| 80 | Demolition of existing RCC tanks and cutting steel to separate the tank from slab etc, and removing debris from MOD land, complete all as specified and as directed. |
| 81 | S&F in repairs of crumple joint with following procedure complete all as specified and as directed(i) Removing the existing plain GI sheet along with fixing accessories like screw bolts from crumple joint .(ii) Cleaning the crumple joint and removing existing bitumen filler board (width upto 50mm & depth upto 500mm ).(iii) Filling the gap with bitumen filler board and covering the joint from both sides with polysulphide sealant.(iv) Fixing only new GI sheet plain, 1mm thick, with screw (fixing accesssories).Note : Make of polysulphide sealent and bitumen filler board to be approved by GEGI plain sheet to be paid seperately on Supply only rates. |
| 82 | Supply only Plain galvanised mild steel sheeting 1.00 mm thick, as in ridges, hips, valley or in crumple fixed with fixing accessories complete all as specified and directed. |
| 83 | M&L for preparation of roof tile surafce at any height (up to 10m ) and applying one coat of tile guard of approved shade including required scaffolding etc complete all as specified and as directed |
| 84 | M&L for Welding in repairs n exc 2.5cm in length and thickness of metal to be welded not exc 6 mm all as specified and as directed. |
| 85 | M&L water proofing treatment of roof as per details given below complete all as specified and as directed.(a) Taking out old roof treatment and roughening the old concrete slab by picking, sweeping clean and washing down with water to remove dust etc and disposal of rubbish outside MOD Land.(b) Filling of cracks upto 3mm by using asian paints crack seal or equivalent as approved by Engineer-in-Charge/GE.(c) Screed bed or bedding layer of 10 mm thick cement mortar 1:4 with mixing of WPC as per manufacturers instructions and surface finished even and smooth without using extra cement after applying a coat of cement slurry @ 3kg/sqm. (d) Surface should be throughly cleaned by using water & vacuum cleaner to avoid 'Peeling off' Problems.(e) Apply a coat of self priming smart care dampproof ultra (code 5698) of M/S Asian paints or equivalent in M/S Dr fixit or M/S Pidilite or M/S Sika chemical with 30% dilution with water using brush/roller on newly plastered surface after curing as per IS-456 and allow to dry for 4 to 6 hours ( dilution and coverage requirement strictly as per manufacturers instructions).(f) After the primed surface has dried, apply first coat of water proofing smart care damp proof ultra (Code 5698) of M/S Asian paints or equivalent in M/S Dr Fixit or M/S Pidilite or M/S Sika chemical using brush/roller on the same primed surface and allow to dry for 4 to 6 hours.(g) Prepare and apply 2nd coat of water proofing smart damp proof ultra (Code 5698) of M/S Asian paints or equivalent in M/S Dr fixit or M/S Pidilite or M/S Sika chemical using brush/roller on the same surface, the temp to be maintained 25 to 35 C through out all above application work.Note : (i)The work shall be carried out through authorised and qualified applicators of the manufacturers only.Make : M/S Asian paints or equivalent in M/S Dr fixit or M/S Pidilite or M/S Sika chemical or equivalent as approved by GE. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender