Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #58526490

Tender For Provn Of Boundary Wall For 05 X Transformer With Hardstand Alongwith Soak Pit And special Repair To 03 X Storage Sheds At Tech Area Under Age B/R-I And Age E/M Of Ge Bengdubi

Issued by Statutory Bodies & Commissions/Committees · Darjeeling, West Bengal
Tender Value
44.74 Lakhs
Estimated cost
Bid Submission
04 Dec 2026
13 days left
EMD
88940
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Darjeeling → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Boundary Wall For 05 X Transformer With Hardstand Alongwith Soak Pit And special Repair To 03 X Storage Sheds At Tech Area Under Age B/R-I And Age E/M Of Ge Bengdubi

BOQ

Name of Work:- PROVN OF BOUNDARY WALL FOR 05 X TRANSFORMER WITH HARDSTAND ALONGWITH SOAK PIT AND SPL REPAIR TO 03 X STORAGE SHEDS AT TECH AREA UNDER AGE B/R-I AND AGE E/M OF GE BENGDUBI
Sl. No. Item Description
1Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
2Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
3Surface dressing n.exc 15 cm deep in soft/loose soil complete all as specified and directed.
4Removing excavated material (soil) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
5M&L for hardcore of gauge n.exc. 63 mm, with broken stone or boulder, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surfaces complete all as specified and directed.
6M&L for cement concrete 1:4:8 type D2,using 40mm graded crushed stone aggregate as in foundations filling and mass concrete complete all as specified and directed.
7M&L for Providing precast ce- ment concrete type B1, 1:2:4 using 20mm graded crushed stone aggregate in window or door cills, lintels,bressumers, steps,quoin blocks (foruse with ma sonry), string courses, copings.kneelers, apex stones, pier caps,columns, posts,boundary pillars,bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling).corbels, brackets, kerb stone edging etc. (of any section indicated), with plain fair faces,including cham fers, weatherings,throat- ing etc. and setting in cement mortar 1:6 complete with joints to match complete all as specified and directed.
8M&L for reinforced cement concrete design mix M 25 grade using 20 mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
9M&L for reinforced cement concrete design mix M 25 grade using 20 mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
10M&L for reinforced cement concrete design mix M 25 grade using 20 mm graded crushed stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and directed.
11Supply only polyester triangular fibres as secondary reinforcement in all types of concrete and mortars as approved by GE.
12Supply only integral water proofing compound liquid grade conforming to IS-2645 complete all as specified and directed.
13M&L for brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
14Making good for wall top for roof sheet or under cills or over arches, lintels and bressummers. including all pinning in cement mortar 1:4 when necessary complete all as specified and directed.
15M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical to rough finished surface complete all as specified and directed.
16M&L for formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide complete all as specified and directed.
17M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finished surfaces of concrete, square, rectangular or polygonal in shape complete all as specified and directed.
18Taking down chowkat or frame with shutter (without taking off shutter from the frame) area not exc. 1.5sqm each, including cutting holes for removing the hold fast,making good disturbed surfaces and removing materials from site of work complete all as specified and directed.
19M&L for Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
20S&F for window guard bars let in and fixed independently in wooden frames or steel frames confirming to Fe 290 Gde E-165.
21S&F Mild steel, plain, black sheet 01mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
22M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
23M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
24M&L for rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to comman rafters and running rails fixed with angle cleats or other connecting plates conforming to Fe 410 W (Gde E-250) quality-A including welded to rafter,purlin complete all as specified and directed.
25S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe -410-W(Gde-E-250) quality-A. complete all as specified and directed.
26S&F MS framed work confirming to Fe 410 -W quality A as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete.
27S&F steel window with side hunge shutters including projecting type hinges with steel handle and steel peg stey, tower bolts etc. complete with glazing bars dovetailed or welded complete all as specified and directed.
28S&F steel window with side hunge shutters including projecting type hinges with steel handle and steel peg stey, tower bolts etc. complete without glazing bars dovetailed or welded complete all as specified and directed.
29M&L for anodised aluminium snap grid (SIZE-605x605MM) frame work for false ceiling complete all as specified and directed.
30S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
31S&F Pre- painted camouflage pattern trapezoidal profiled Galvalume/ Zincalume sheet with min thickness 0.50mm TCT confirming to IS - 513(AZ-150 GSM, Al Zn allay metalic coating with 550 Mpa yield stress as per AS-1397) as in roof covering/cladding to wall, fixed with self tapping screws colour exterior coat of silicon modified polyster/BHP x RW paint system 20 micron top coat applied over 5 micron primer and 5 micron polyster back coat applied over 5 micron primer , all fixed with galvanized self drilling self tapping fastner (12-14 x 55 with EPDM seals) complete all as specified and directed.
32S&F Pre- painted camouflage pattern plain sheet Galvalume/ Zincalume sheet with min thickness 0.50mm TCT confirming to IS - 513(AZ-150 GSM, Al Zn allay metalic coating with 550 Mpa yield stress as per AS-1397) as in roof covering/cladding to wall, fixed with self tapping screws colour exterior coat of silicon modified polyster/BHP/ XRW paint system 20 micron top coat applied over 5 micron primer and 5 micron polyster back coat applied over 5 micron primer , all fixed with galvanized self drilling self tapping fastner (12-14 x 55 with EPDM seals) complete all as specified and directed.
33M&L for 75mm thick PCC type B2,1:2:4 using 40mm graded crushed stone aggregate as in floor/path and finished the surface even and smooth without using extra cement complete all as specified and directed.
34M&L for 75mm thick PCC type D2,1:4:8 using 40mm graded crushed stone aggregate as in sub base of PCC floor/path complete all as specified and directed.
35Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
36M&L for sheet glass, 3mm thick, plain ordinary quality and glazing with oil putty in squares n exc. 0.50 Sqm each pane complete all as specified and directed.
37M&L for one coats of synthetic enamel paint on old treated steel surfaces of any description over 10cm in width or girth including preparation of surfaces complete all as specified and directed.
38M&L for two coats of synthetic enamel paint over one coat of red oxide on new steel surfaces of any description over 10cm in width or girth including preparation of surfaces complete all as specified and directed.
39M&L for rewriting repainting existing writing letters or figures including preparation for painting (block roma, roman, italic, Indian n exc 30 cm height) complete all as specified and directed.
40S&F 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
41Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings,dressed stonework and precast concrete articles complete all as specified and directed.
42Demolition of cement concrete( un-reinforced) in ground floor and paving n.exc 15 cm thickness( below or above ground level) complete all as specified and directed.
43Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
44Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed.
45Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings incl ridges, hips and valley gutter complete all as specified and directed.
46Dismantling wall and ceiling board( fiber, pulp, insulation, etc.) or insulation board/slab/ blankets, any thickness, including cover fillets complete all as specified and directed.
47Preparation of new surfaces of walls and applying two coat of exterior emulsion (weather coat) over a coat of anti alkaline primer in different for camouflage and concealment of sigma II software design/ patterns approved by users complete all as specified and directed.
48Complete removal of existing treatment of walls and preparation of old plastered surface of walls including plasters and cornices etc and applying two coat of exterior emulsion (weather coat) over a coat of anti alkaline primer in different for camouflage and concealment of sigma II software design/ patterns approved by users complete all as specified and directed.
49M&L for preparing newly plastered surface of wall and applying 02mm thick wall care putty complete all as specified and as directed.
50M&L for newly plastered surface of wall appying two coat of white or tinted oil bound distemper over one coat of alkali resistant priming paint including 02mm thick wall care putty etc complete all as specified and as directed.
51S&F 6 mm thick designed pre painted Non asbestos fiber cement building boards, fixed or laid /inserted to timber /GI /Aluminium frame-work with screws as in ceiling complete all as specified and directed.
52M&L for 75mm thick PCC 1:3:6 type C2 (Using 40mm graded crushed stone aggregate) as in plinth protection finished even and smooth using extra cement.Joints to be given at every 3m interval and corners of buildings and fitted with bituminious mastic or equivalent filler complete all as specified and directed.
53M&L for 75 mm thick PCC 1:2:4 type B1 (using 20 mm graded crushed stone agg) and finish the concrete surface even and smooth without using extra cement as in flooring complete all as specified and directed.
54M&L for 40mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregates) as in flooring, finished the surface with using extra cement complete all as specified and directed.
55M&L for Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size nconfirming to IS 15658-2006 of 60 mm thickness, M-35 Grade over and including 25mm thick sand filling layer well rammed and compacted complete all as specified and directed,
56M&L for rendering 15 mm thick in cement mortar 1:4 on external surfaces of brick work or concrete surfaces with using WPC finishing the surfaces even and smooth without using extra cement complete all as specified and directed.Note:- WPC will be measured and paid separately under respective item of this schedule.
57M&L for 15mm thick rendering on other than fair faces in cement mortar 1:6 finished the surface even and smooth without using extra cement complete all as specified and directed.
58M&L for newly surface of ceiling board and appying two coat of white or tinted oil bound distemper over one coat of primer complete all as specified and directed.
59M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkai registant primer complete all as specified and directed.
60M&L for Air termination, single pointed aluminium rod 12mm dia and 300mm long incl taking down complete all as specified and directed.
61M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
62S & F DMC electrical insulator for laying aluminium strip complete all as specified and directed.
63M&L for Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground including good making for any surface and taking down existing complete all as specified and directed.
64S&F GI earth strip of size 32x6 mm fixed on wall with insulators and laid in trench including good making for any surface incl taking down existing complete all as specified and directed.
65M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth strip 25X4 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 40 mm dia. light grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion INCL TAKING DOWN EXISTING. Note :- GI earth strip 25x4 mm and 40 mm dia GI pipe light for protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.
66(Note : The Scope of Work contained in 'Sch of Credit' amounting to Rs. 1,89,926.10 (refer Sch of Credit). The Quoted sum shall be arrived at after deducting the amount of “Sch of Credit” from the total amount of the ‘BoQ’ Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58526490
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 44.74 Lakhs
LAST DATE 04-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Boundary Wall For 05 X Transformer With Hardstand Alongwith Soak Pit And special Repair To 03 X Storage Sheds At Tech Area Under Age B/R-I And Age E/M Of Ge Bengdubi
Basic Detail
Tender No 8921/E8
Bidding Type Tender
Location
City Darjeeling
State West Bengal
Key Dates
Publish Date 13 Nov 2026
Submission Date 04 Dec 2026
Open Date 07 Dec 2026
Finance
Tender Value 44.74 Lakhs
Tender Fee 500
EMD 88940
Exemption Available
Document List
BOQ_895728.xls
d070aa3f-9715-4d2c-b816-d596c2faf8f8.html
TENDER8921.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Dec 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_895728.xls

html

d070aa3f-9715-4d2c-b816-d596c2faf8f8.html

pdf

TENDER8921.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender