Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #58526481

Tender For Provision Of Equipment Store With Humidity And Air Control Parameters For 13 Para (Sf) At Hebbal Garrison Under Ge (South) Bangalore

Issued by Statutory Bodies & Commissions/Committees · Bengaluru Urban, Karnataka
Tender Value
44.35 Lakhs
Estimated cost
Bid Submission
05 Dec 2026
16 days left
EMD
88700
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provision Of Equipment Store With Humidity And Air Control Parameters For 13 Para (Sf) At Hebbal Garrison Under Ge (South) Bangalore

BOQ

Name of Work:- PROVISION OF EQUIPMENT STORE WITH HUMIDITY AND AIR CONTROL PARAMETERS FOR 13 PARA (SF) AT HEBBAL GARRISON UNDER GE (SOUTH) BANGALORE
Sl. No. Item Description
1Excavation in trenches not exc 1.5m wide and 1.5m deep and getting out in hard/dense soil for foundation and similar work.
2Excavation in trenches exc 1.5 m deep not exc 3.00 m deep and getting out in hard/dense soil for foundation and similar work.
3Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed
4Returning filling in including spreading levelling, watering and well ramming in layers not exc 25 cms thick.
5M&L for Earth Filling under floors or in foundations including watering and consolidation.
6M&L Cement concrete in foundations, filling and mass concrete type D-2 1:4:8 (40mm graded aggregate).
7M&L Reinforced cement concrete (design mix M-25 grade using 20mm graded aggregate) in Foundations footings, plinth beams, bases for columns, etc and mass concrete
8M&L Reinforced cement concrete (design mix M-25 grade using 20mm graded aggregate) Columns, pillars, piers, posts and struts
9M&L Reinforced cement concrete (design mix M-25 grade using 20mm graded aggregate) Beams, cantilevers, bressummers, lintels over 1.5m span
10M&L Reinforced cement concrete (design mix M-25 grade using 20mm graded aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like,
11M&L Reinforced cement concrete (design mix M-25 grade using 20mm graded aggregate) as in chajjas
12M&L Formwork flat or curved to sides of concrete foundations, footings, bases of columns, and plinth beams and similar work vertical or to batter
13M&L Formwork flat or curved to sides of pillars, posts, struts, piers, columns and stanchions
14M&L Formwork flat or curved to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
15M&L Formwork flat or curved to Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
16M&L Formwork to edges of concrete flats, treads, breaks in floors, window-cills, concrete railing, openings in concrete walls, floor and roofs not exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or
17M&L Formwork to chullah hoods, chajjas, troughs and similar items including edges
18M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
19M&L for Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally as Stirrups.
20M&L for providing 3 mm thick APP modified membrane over and including cement plaster 15 mm thick and providing screed bed/rendering 15mm thick in CM (1:3) mixed with and including supply of approved water proofing compound as per manufacturers instructions and applying a coat of solar reflective bituminous aluminium paint @ 0.10 litre/sqm on top of RCC roof with the following specifications:-(a) Cleaning existing surface properly.(b) Apply oil bound bitumen primer @ 0.40 lit/Sqm manufactured by the same agency as that of APP with a density o 0.87-0.89 Kg/Lit at 25° C on the prepared dry roof surface., providing and laying APP modified water proofing membrane reinforced with non woven polyester matt with physical prosperities as under:- (i) Membrane weight > 3.8 Kg/ sqm (ii) Non woven polyester weight > 160 gm/Sqm (iii) Softening point of membrane > 150° C (iv) Joint tensile strength longitudinal > 650 Sqm Cm at 230° C & Transverse > 450/Sq Cm (v) Tear strength - longitudinal > 300N & Transverse > 250 N Direction (vi) Elongation > 30 % (vii) Impermeability under water pressure > 3 Kg/Sq cm
21M&L pre-cast cement concrete masonry in PCC 1:3:6 type C1 using 20mm graded aggregate with solid block, exceeding 10cm in width setting in CM 1:6 complete.
22M&L for Pre-cast cement concrete masonry in PCC 1:3:6 type C1 using 20mm graded aggregate with solid block, not exceeding 10cm in width setting in CM 1:4 complete.
23M&L for 15mm thick rendering in two layers of 10mm thick backing coat in CM 1:6 and 5mm thick floating coat in CM 1:4 mixed with water proofing compound on all external wall surfaces all as specified and as directed by Engg-in-charge (WPC paid separately)
24Supply only liquid water proofing compound
25M&L for 10mm thick rendering in CM 1:6 on all internal wall surfaces all as specified and as directed by Engg-in-Charge
26M&L for rendering 5mm thick in CM 1:3 on soffits of RCC slabs, roof projections, soffits and sides of RCC beams, waist slab, Loft Slab, RCC shelves, Chajjas, and the like...
27M&L Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 10cm thick, watered and rammed to a true surface.
28M&L 100mm thick PCC 1:4:8 Type D-2 as in sub base for floors, ramp etc.
29Material and labor for P.C.C type B-1, 1:2:4 (20mm graded aggregate) 40 mm thick in ramp, finishing cement concrete surface even and fair without using extra cement etc
30Material and labor for P.C.C type B-1, 1:2:4 (20mm graded aggregate) 25 mm thick in flooring finishing cement concrete surface even and fair without using extra cement etc.
31M&L 75mm thick Cement concrete type C2, 1:3:6 (40mm graded aggregate) as in plinth protection
32M&L PCC Type B0 1:2:4 (12.5 mm graded aggregate), coping, as in hold fast and as in steel frame of window back filling and in roof kerbs of mud stops, rounded or chamfered on edges cills, steps etc; all as specified and directed by Engineer-in-Charge
33S & F Butt hinges medium weight, cold rolled mild steel 100mm long and fixed to door frame and shutter duly welded/screwed complete
34S & F Aluminium anodized barrel tower bolt of extruded section of size 125mm long complete
35S & F Extruded Aluminum handles 150mm size, fabricated type, anodised all as specified
36M&L PCC Type B0 1:2:4 (12.5 mm graded aggregate), coping, as in hold fast and as in steel frame of window back filling...
37M&L for 18/20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms...
38M & L for 20-25mm thick machinecut kota stone slab, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement
39M & L for 20-25mm thick machinecut kota stone slab, riser of step, skirting etc. set and jointed in neat cement slurry
40M & L for Screed bed or bedding layer of mortar 20 mm thick in Cm 01:4 for laying floor finishes
41M&L for preparation of newly plastered surfaces of walls and applying two coat of cement base paint, including one coat of white washing primer
42M & L for applying two coats of oil bound distemper over a coat of alkali resistant primer on newly plastered surfaces of wall
43M & L for applying two coats of of white wash on newly plastered surfaces of Ceilings, soffits of RCC slabs, roof projections...
44S&F Hard drawn steel wire fabric in available size weight not exc 4.00 Kg /sqm fixed in tank caging including welding, riveting, framing etc completed all as specified and as directed.
45S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for handing or sliding with and including either hooks and hinges or steel handing door fittings (exclusive or steel sheeting or other covering, running rails and guides) and handing; also fastening and fixing complete
46S&F Steel windowss with side hung shutter with glazing bar complete all as specified and as directed.
47S&F Steel windows/ Ventilitors with side hung shutter without glazing bar complete all as specified and as directed by
48Supply and fix 4mm thick sheet glass ordinary quality and glazing with rubber packing around the glass, in squares n. exc 0.5 Sqm in each pane complete all as specified and as directed by Engineer-in-charge.
49Supply only stainless steel wire cloth 0.36mm nominal dia and average width of aperture 1.40mm and fixed with tinned tack or galvanized wire staple all as directed fixed.
50Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work as in ornamental type gate con-forming to Fe 290. Gde-E-165
51M & L applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces over 10 cm width or girth including preparation of new steel surfaces
52M&L preparing new wooden surface of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and as directed by Engineer-in-charge.
53Pressed steel frames made of 1.25mm thick MS sheet of profile 105x60mm x for door and window frames with one rebate including lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for houeing of a drop bolt, treating of internal surfacing chowkhats with coil tar or black paint incl hinges/lugs etc complete all as specified and directed by Engineer-in-charge.
54All as per item No 53 above but size 125x60mm with double rebate.
55S&F Flush door shutters 35mm thick, factory made as per IS:2202 (Part-I 1999) solid core construction, with block board core with decorative face veneer both faces with lipping/frame to match as per drawing fixed to chowkhats all as speified and directed by Engineer-in-charge.
56S&F 2nd class hard wood 35 mm thick made glazed and skeleton shutters open rebated and prepared to receive glass, gauze,etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc, size of members of shutters as spfd in SSR Part-1, Section 8, clause 8.24 (a) kiln seasoned and chemically pressure treated complete all as specified and as directedNote: Supply & fixing of 4 mm thick sheet glass or wire mesh be measured and paid separately.
57S&F Aluminium anodised tower bolt 200 mm long of extruded section etc complete all as specified and as directed by Engineer-in-charge.
58S&F 150 mm long aluminium handle, cast type, anodised etc complete all as specified and as directed by Engineer-in-charge.
59S&F aluminium alloy, anodised sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy etc complete all as specified and as directed by Engineer-in-charge.
60S & F 140 mm floor door stopper of aluminium alloy powder coated, with hard down steel spring all as specified and as directed by Engineer-in-charge.
61S&F mild steel 300mm, ordinary rat tail rod pattern springs, including roller and roller plate complete all as specified and as directed by Engineer-in-charge.
62S&F 110 mm dia PVC (SWR) Pipe single socketed in any length with rubber ring joint ladi in trenches / fixed on floor/ walls incl jointing with solvent complete all as specified and as directed by Engineer-in-charge.
63S&F 110 mm dia PVC (SWR) bends with access door any radius complete all as specified and as directed by Engineer-in-charge.
64Excavating over areas not exc 1.50m deep and getting out in Soft/Loose soil complete all as specified and as directed by Engineer-in-charge.
65Plain cement concrete 1:2:4, Type B2, (using 40mm graded stone aggregate), 100 mm thick in sub-base concrete to pavement complete all as specified and as directed by Engineer-in-charge.
66Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.
67Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;
68Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out hard dense soil.
69Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed
70Wiring complete concealed with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concelaed type wiring incl GI/ MS branded sunken boxes suitable for normal/modular concealed on walls including plastic/heylam laminated sheet top cover 3 mm thick/modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular/normal type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following :-
71One light point controlled by one switch
72One 3 pin socket out let 5 A on same board
73One 3 pin socket out let 5 Amps on independent board
74All as per Srl item No 70 above but for 16 Amps socket outlet by using 2.5 Sqmm PVC insulated unsheathed copper conductor multi stranded on independent board including provn of 2.5 Sqmm PVC insulated solid copper conductor continus as earth wireNote for Item No 70.00 to 71.00 :-(i) The earth wire for the points in the same circuit can be looped from point to point(ii) Earth wire shall be taken inside the conduit(iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring(iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring.
75S&F LED batten suitable for indoor applications 18/20 Watts, 4 feet with extruded aluminium housing & integrated LED channel rectangular white arcylic cover complete with all accessories all as specified and directed.
76S&F for modular switch , single pole, one way 5/6 Amps, 230 Volts complete all as specified and directed by Engr-In-Charge.
77S&F for modular socket ,single pole, one way 5/6 Amps, 230 Volts complete all as specified and directed by Engr-In-Charge.
78S&F for modular switch ,single pole, one way 16 Amps, 230 Volts complete all as specified and directed by Engr-In-Charge.
79S&F for modular socket ,single pole, one way 16 Amps, 230 Volts complete all as specified and directed by Engr-In-Charge.
80S&F MCB SPN 240 volts 40 Amps complete all as specified and as directed
81S&F MCB single pole 240 volts 6 to 32 Amps complete all as specified and as directed
82S&F MCB DB SPN 8 way double door type 240 volts with 200 Amps rated busbar as specified and as directed.
83S&F MCB DB TPN 4 way with double door type 415 volts with 200 Amps rated busbar for housing MCBs as specified and as directed.
84S&F MCB TPN 415 volts, 10KA 'C' curve 63 Amps complete all as specified and as directed
85S&F MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and as directed
86provision of sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 6 Sqmm along with 6 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed
87S&F ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed
88M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed.
89Supply and fixing 30 W LED bldg security light fitting with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection complete all as specified and as directed.
90S&F Bracket made out of GI tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc and including before fixing applying two coats of aluminum paint over a coat of red oxide primer including removing the old existing GI bracket from bldg complete all as specified and directed.
91Removing excavated material n exc. 50m and depositing where n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point.
92M&L for sand cushioning with a layer of river sand 23 cm thick under and above the cable complete all as specified and as directed
93S&L sub class burnt bricks for cable protection complete as specified as directed
94S&L XLPE insulated, screened, PVC bedded, galvanised steen strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 50 Sqmm, 3.5 core laid in trenches/wall complete all as specified and as directed
95S&L XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm 4 core laid in trenches complete all as specified and as directed
96S&F GI tubing light grade 40 mm bore with all fitting laid in trenches/walls/Roads for cable protection complete all as specified and as directed.
97Supply, installtion,testing commisioning of LT panel, out door type, platform mounted, totally enclosed, dust and vermin proof, openable from both front and rear side, made out of 3.15 mm thick CRCA sheet complete including inner chambers/partitions to mount the following electrical accessories and built upon 50x50x6mm angle iron frame work, having front & rear hinged doors, lifting lugs (2 Nos), provision for earth strip connection, bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts and washers. The cabinet & all members should be chemically treated with anti-corrosive chemicals and apply spray paint with two coats of synethetic enamel paint over a coat of red oxide primer. The internal connection of MCCB should be provided with Al strip of suitable size and necessary grouting/ foundation all as required at site and comprising following:-BUS BAR - Aluminium bus bar system of capacity 200 amp four pole duly colour coded.INCOMER - MCCB, 4 pole of capacity 125 amps with breaking capacity of 35 KA . - 01 No.Outgoing-MCCB 63A, 4 pole, 25 KA, 415V - .2 Nos MCCB, 4 pole of capacity 32 amps with breaking capacity of 25 KA . - 02 No.Digital multimeter of size 96x96 sqmm - 01 NoTimer switch for switching ON/ OFF Street light daily astronomical calculation of sunrise/sunset timesbased on intered loc or loc coordinates. Nos-01 BUS BAR - Aluminium bus bar system of capacity 200 amp four pole duly colour coded. INCOMER - MCCB, 4 pole of capacity 125 amps with breaking capacity of 35 KA . - 01 No. Outgoing-MCCB 63A, 4 pole, 25 KA, 415V - .2 Nos MCCB, 4 pole of capacity 32 amps with breaking capacity of 25 KA . - 02 No. Digital multimeter of size 96x96 sqmm - 01 No Timer switch for switching ON/ OFF Street light daily astronomical calculation of sunrise/sunset timesbased on intered loc or loc coordinates. Nos-01
98M&L for Plain cement concrete 1:3:6, type C1, using 20 mm graded stone aggregate for coping incl necessary form work complete all as specified and as directed
99Supply and fixing 90 W LED street light light fitting with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection complete all as specified and as directed.
100Supply and errection Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long) all as specified and as directed.
101S&F Bracket made out of GI tubing medium grade 40 mm bore, approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm, nuts, bolts, washers etc and including before fixing applying two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed.
102S&L galvanised iron steel tube, light grade, with all fittings fixed complete on walls, poles, laid under floors or in trenches as cable protection works (including necessary clamps, bolts, nuts, etc.,) as specified for 40 mm bore pipe complete all as specified and as directed
103Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2 of capacity 2 TON incl suitable size of wall mounted voltage stabilizer complete all as specified and as directed.
104S&F of Single pole & neutral enclosure 20 Amps & 240 V with two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and as directed.
105Provision of sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 4 Sqmm along with 4 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58526481
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 44.35 Lakhs
LAST DATE 05-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provision Of Equipment Store With Humidity And Air Control Parameters For 13 Para (Sf) At Hebbal Garrison Under Ge (South) Bangalore
Basic Detail
Tender No 8183/E8
Bidding Type Tender
Location
City Bengaluru Urban
State Karnataka
Key Dates
Publish Date 14 Nov 2026
Submission Date 05 Dec 2026
Open Date 07 Dec 2026
Finance
Tender Value 44.35 Lakhs
Tender Fee 500
EMD 88700
Exemption Available
Document List
BOQ_895976.xls
e9031eff-1d95-4268-b7cd-0ace48613330.html
Tenderdocument8183.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Dec 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_895976.xls

html

e9031eff-1d95-4268-b7cd-0ace48613330.html

pdf

Tenderdocument8183.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender