Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #58526476

Tender For Provision Of Soild Waste Management At Hebbal Garrison Under Ge(South) Bangalore

Issued by Statutory Bodies & Commissions/Committees · Bengaluru Urban, Karnataka
Tender Value
24.32 Lakhs
Estimated cost
Bid Submission
05 Dec 2026
17 days left
EMD
48640
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provision Of Soild Waste Management At Hebbal Garrison Under Ge(South) Bangalore

BOQ

Name of Work:- PROVISION OF SOILD WASTE MANAGEMENT AT HEBBAL GARRISON UNDER GE(SOUTH) BANGALORE
Sl. No. Item Description
1M & L Excavating in trenches not exc 1.5 mtr depth, n exc 1.5 m deep and getting out Hard/Dense Soil.
2M & L Excavating in trenches not exc 1.5mtr wide, exc 1.5 m but n. exc 3m deep and getting out Hard/Dense Soil.
3M&L Cement concrete in foundations, filling and mass concrete type D-2 1:4:8 (40mm graded aggregate)
4M&L Reinforced cement concrete (design mix M-25 grade using 20mm graded aggregate) in Foundations footings, plinth beams, bases for columns, etc and mass concrete
5M&L Reinforced cement concrete (design mix M-25 grade using 20mm graded aggregate) above top of footings including attached pilasters and buttresses
6M&L Reinforced cement concrete (design mix M-25 grade using 20mm graded aggregate) Columns, pillars, piers, posts and struts
7M&L Reinforced cement concrete (design mix M-25 grade using 20mm graded aggregate) Beams, cantilevers, bressummers, lintels over 1.5m span
8M&L Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm
9M&L Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed
10M&L Formwork flat or curved to sides of concrete foundations, footings, bases of columns, and plinth beams and similar work vertical or to batter
11M&L Formwork flat or curved to to sides of pillars, posts, struts, piers, columns and stanchions
12M&L Formwork flat or curved to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelvesincluding sup- ports, overhangs, etc. also splays between floors and beams, etc.
13M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
14All as per item No 13 above but 6mm to 8mm dia, in stirrups
15M&L pre-cast cement concrete masonary in PCC 1:3:6 type C1 using 20mm graded aggregate with solid block, exceeding 10cm in width setting in CM 1:6 complete.
16M&L for rendering 15mm thick cement plaster in CM 1 :4 on concrete surfaces of roof slab and parapets mixed with WPC @ 3% by weight of cement shall be carried out all as specified and directed by the Engineer-in-Charge ( WPC shall be measured and paid separetely)
17M&L Filling under floors or in foundations including watering and consolidation
18M&L Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 10cm thick, watered and rammed to a true surface
19M&L 75mm thick PCC 1:4:8 Type D-2 as in sub base of floor complete all as specified and as directed by EIC.
20M & L for Cement concrete 40mm thick type B-1, 1:2:4 (20mm graded aggregate) Finishing cement concrete surface even and smooth without using extra cement
21M&L Three coats of white wash on internal wall surfaces including preparations above skirting/Dado
22S & F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment
23S & F for steel work in Compound girders andstanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc
24S & F for steel work in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.
25Preparation of new or previously untreated steel surfaces & applying a two coats of synthetic enamel paint over a coat of red oxide primer over 10cm in width or girth,not otherwise described.
26S & F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
27S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
28Material and Labour for 75 mm thick plain cement concrete 1:3:6 type C1 (using 20 mm graded stone aggregate) as in paving/ plinth protection laid in panels including necessary form work, finished rough surfaces of concrete complete all as specified and directed
29S&F Steel windows/ Ventilitors with side hung shutter without glazing bar complete all as specified and as directed
30Supply and fix 4mm thick sheet glass ordinary quality and glazing with rubber packing around the glass, in squares n. exc 0.5 Sqm in each pane complete all as specified and as directed by Engineer-in-charge.
31Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work as in ornamental type gate con- forming to Fe.290.Gde-E-165
32S&F rotational moulded polythylene water storage tanks 1000 ltrs capacity (cylindrical or vertical with closed top) hoisted and fixed in position, complete all as specified and directed by Engineer-in-Charge
33Supplying and laying of 25mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in to walls, ceilings or in floors etc.,complete all as specified.
34Supplying and laying of 20mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in to walls concealed, complete all as specified.
35Supplying and fixing of 25mm bore Brass Elbow complete all as specified.
36Supplying and fixing of 25mm bore Brass Tee complete all as specified.
37Supplying and fixing of 20mm bore Brass Elbow complete all as specified.
38Supplying and fixing of 20mm bore Brass Tee complete all as specified.
39Supplying and fixing of 25mm bore BALL VALVE complete all as specified.
40S & F 15 mm bore fancy type chromium plated Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed
41S & F of Steel rolling shutters, ( thick ness of lath 1 mm) with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified and directed
42S & F Safety lever locks mild steel with 4 levers for rolling shutters
43S & F of ball bearing for rolling shutters
44Excavating over areas not exc 1.50m deep and getting out in Hard/Dense soil
45Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed
46Plain cement concrete 1:4:8, Type D2, (using 40mm graded stone aggregate), 100 mm thick in sub-base concrete to pavement
47Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.
48Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;
49Excavating in post hole or similar holes nexc 0.5cum each getting out returning filling in and ramming with water in layer nexc 30cm all as per specified and directed.
50S & F mild steel works conforming to Fe 290 Gde E-165 as in angle iron post and struts in fencing incl cutting tops to shape as directed drilling holes notching for wire etc. incl all necessary drilling, bolting of riveting etc. etc complete all as specified and as directed
51M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in fixing of post/ drain foundation filling and mass concrete complete all as specified and directed.
52S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured).
53S&F of Mild steel screw bolts(Machine made, dia of neck 10mm) with hexagonal or square heads at one end and screwed the other, or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut n exc 5cm long.
54M&L for Mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete.
55M&L for Preparation of new steel and iron surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed
56Supply only Chain link MS galvanisd fencing, any size or type
57Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire
58Wiring complete concealed with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concelaed type wiring incl GI/ MS branded sunken boxes suitable for normal/modular concealed on walls including plastic/heylam laminated sheet top cover 3 mm thick/modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular/normal type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following :- (a) One light point controlled by one 5 Amps switch one way
59(b) One fan point controlled by one 5 Amps switch one way
60(d) One 3 pin socket point 5 Amp on independent board
61(e) One 3 pin socket point 5 Amp on same board with other switches.
62All as per Srl item No 58 habove but for 16 Amps socket outlet by using 2.5 Sqmm PVC insulated unsheathed copper conductor multi stranded on independent board including provn of 2.5 Sqmm PVC insulated solid copper conductor continus as earth wire. Note for Item No 58 to 59 :- (i) The earth wire for the points in the same circuit can be looped from point to point (ii) Earth wire shall be taken inside the conduit (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring.
63S&F for modular switch ,single pole, one way 5/6 Amps, 230 Volts complete all as specified and directed by Engr-In-Charge.
64S&F for modular socket , single pole, one way 5/6 Amps, 230 Volts complete all as specified and directed by Engr-In-Charge.
65S&F for modular switch ,single pole, one way 16 Amps, 230 Volts complete all as specified and directed by Engr-In-Charge.
66S&F for modular socket , Single pole, one way 16 Amps, 230 Volts complete all as specified and directed by Engr-In-Charge.
67Supply and fix Ceiling rose surface bakelite 65x50mm three terminals including supply and fix PVC blocks.
68Supply and fix Sub main wiring with 3 runs of 10 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in existing non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 10sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion complete all as specified and directed.
69Supply and fix Sheet metal enclosure (ISI marked) distribution board TPN, 415 volts, 4 way horizontal type double door type, 200 Amps rated neutral copper bus bar for housing MCB and fixed and tested on completion complete all as specified.
70S&F Triple pole and earth enclosure with a three pin and earth plug with socket complete with TPN MCB 63A
71Supply and fix MCB SPN 40 to 63 Amps 240 volts, C series,10 kA rupturing capacity providing in DB complete all as specified.
72S&F MCCB 4 pole 415 volts 100 Amps 16 KA, fixed type complete all as specified and as directed
73Supply and fix Switch socket combination flush type 6/16 Amps 3/3 pin universal multipurpose
74S&F Exhaust fan 300mm sweep ,steel body AC single phase with blades,frame and louvers
75S&F LED tube light fitting of 20 watts 6000K , 230 volt, with Basic all purpose surface and wall mounted LED batten efficacy 135 lum/w with aluminium extruded channel powder coated with diffuse with electronic driver complete with all fixing accessories such as 2 nos of aluminium square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge.
76Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermaland corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
77S&F of Bracket made out of GI tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc and including before fixing applying two coats of aluminum paint over a E43:H55coat of red oxide primer /including removing the old existing GI bracket from bldg complete all as specified and directed.
78S&F ceiling fans with complete accessories, 230V, SP 1200 mm Sweep with BEE 5 Star rating complete with all accessories and fixing the fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm, etc all as specified and as directed. .
79S&F and testing commissioning of Organic Waste Composter of Capcity 200Kg constisting of motor 3HP, hot air blower 500CFM,gear box reduction mechanisim approx weight of machine 1400 kgs,made out of vessel and shaft material with SS304 and outer body SS202, fully automatic solution designed to process up to 200 kg of organic waste per day converting it into nutrient-rich compost all as directed by Engineer-in-charge.
80Fabricate,supply, install, connect, test and commission LT busbar box/panel board/out door type, made out of MS sheet 3.15 mm thick and angle iron 40x40x6 mm frame, 3 phase, 4 wire, 440 Volts, AC, 50 HZ with TPN bus bar of suitable 63 AMPS with MCCB 63Amps,415V,16KA and 08 briges capacity with PVC insulated heat shrink colour code sleeves, mounted horizontaly with porcelain insulators, sufficient air vent provision for all the three sides, stickers / plastic plates for switch gear details complete , indicating lamps with toggle switches duly wired including, ELR with CBET locking arrngement including suitable foundation and platform for mounting the panel with space all as specified as directed
81M&L XLPE insulated, sreened, PVC bedded, galvanised steel strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 votls grade, cross sectionl area 16 Sqmm, 4 core laid in trenches.
82M&L in repair for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed.
83Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying pipes or foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n.exc 10sqm on plan and n.exc 1.5m in depth and getting out in any type of soil.
84Removing excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
85M&L for sand cushioning with a layer of river sand 23 cm thick under and above the cable complete all as specified and as directed
86S&L sub class burnt bricks for cable protection complete as specified as directed
87S&F GI tubing light grade 32 mm bore with all fitting laid in trenches/walls/Roads for cable protection .
88Supply and lay in trenches / on roof / on wall / steel water 25 mm dia bore tubing galvanised medium grade with all fittings of sizes
89Cutting the existing pipe line and connected pipe line
90Supply and fix 25 mm dia bore gun metal gate valve with iron wheel head screwed both ends for iron pipe of size . Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58526476
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 24.32 Lakhs
LAST DATE 05-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provision Of Soild Waste Management At Hebbal Garrison Under Ge(South) Bangalore
Basic Detail
Tender No 8181/E8
Bidding Type Tender
Location
City Bengaluru Urban
State Karnataka
Key Dates
Publish Date 14 Nov 2026
Submission Date 05 Dec 2026
Open Date 07 Dec 2026
Finance
Tender Value 24.32 Lakhs
Tender Fee 500
EMD 48640
Exemption Available
Document List
992005a2-c0bf-437e-a027-9e5364639e81.html
BOQ_895959.xls
Tenderdocument8181.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Dec 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

992005a2-c0bf-437e-a027-9e5364639e81.html

xls

BOQ_895959.xls

pdf

Tenderdocument8181.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender