Tender For Addition / Alteration To Kote And Special Equipment Stores Of 13 Para (Sf), 604 And 626 Guard Flights And Jcos Mess At Hebbal Garrison Under Ge (South) Bangalore
Tender Value
31.42 Lakhs
Estimated cost
Bid Submission
05 Dec 2026
16 days left
EMD
62840
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Addition / Alteration To Kote And Special Equipment Stores Of 13 Para (Sf), 604 And 626 Guard Flights And Jcos Mess At Hebbal Garrison Under Ge (South) Bangalore
BOQ
| Sl. No. | Item Description |
| 1 | Taking down chowkat (without taking of shutter from the frame) not exc 1.5 sqm each including making good the disturbed surface in PCC 1:2:4 Type B0 or C1:3 all as specified and directed |
| 2 | All as per item No 1 above, but exc 1.50 sqm and not exc 4.00 sqm each |
| 3 | Dismantling of structural steel work including doors, gates but excluding framed truss etc all as specified and directed |
| 4 | Demolition of brick/stone/boulder/precast concrete articles and precast concrete block built in cement mortar etc complete all as specified and directed |
| 5 | Taking down cement plaster of any description including racking out joints, hacking for key and disposal of debris to out side MD land all as specified and as directed. |
| 6 | M&L pre-cast cement concrete masonry in PCC 1:3:6 type C1 using 20mm graded aggregate with solid block, exceeding 10cm in width setting in CM 1:6 complete. |
| 7 | M&L for 10mm thick rendering in CM 1:6 on all internal wall surfaces all as specified and as directed by Engg-in-Charge |
| 8 | M&L for 15mm thick rendering in two layers of 10mm thick backing coat in CM 1:6 and 5mm thick floating coat in CM 1:4 mixed with water proofing compound on all external wall surfaces all as specified and as directed. (WPC shall be paid separately) |
| 9 | Supply only liquid water proofing compound |
| 10 | M&L for rendering 5mm thick in CM 1:3 on soffits of RCC slabs, roof projections, soffits and sides of RCC beams, waist slab, Loft Slab, RCC shelves, Chajjas, and the like all as specified and as directed. |
| 11 | M&L PCC Type B0 1:2:4 (12.5 mm graded aggregate), coping as in hold fast and as in steel frame of window back filling and in roof kerbs of mud stops, rounded or chamfered on edges cills, steps etc; all as specified and directed. |
| 12 | S&F Butt hinges medium weight, cold rolled mild steel 100mm long (150mm amended to 100mm) and fixed to door frame and shutter duly welded/screwed complete all as specified and as directed |
| 13 | S&F 200 mm long Mild steel tee hinges heavy type, stove enamelled black, complete all as specified and directed |
| 14 | S&F MS pressed handles 150mm size, oval type, stove enamelled black all as specified and directed |
| 15 | S&F Mild Steel Sliding Door bolts 375 mm long, plate type stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed |
| 16 | M&L for newly plaster surfaces of Wall and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm incl all necessary safety norms to the workers all as specified and directed. |
| 17 | M&L for applying two coats of oil bound distemper over a coat of alkali resistant primer on newly plastered surfaces of wall including preparation of surfaces complete all as specified and as directed |
| 18 | M&L for applying two coats of white wash on newly plastered surfaces of Ceilings, soffits of RCC slabs, roof projections, soffits and sides of RCC beams, waist slab, Loft Slab, RCC shelves, Chajjas, and the like including preparation of surfaces complete all as specified and as directed |
| 19 | S&F Hard drawn steel wire fabric in available size weight not exc 4.00 Kg/sqm fixed in tank casing including welding, riveting, framing etc complete all as specified and as directed |
| 20 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. complete, drilled for fixing of steel sheeting or other covering. Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete |
| 21 | M&L applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces over 10 cm width or girth including preparation of new steel surfaces |
| 22 | M&L for Complete removal of existing treatment on walls of any description over 10cm girth or width and applying two coats of oil emulsion distemper over one coat of alkali resistant primer over one coat of chalk whiting putty on plastered surfaces of walls including in narrow widths/bands etc complete all as specified and as directed |
| 23 | Preparation of old decorated surfaces and applying one coat of white wash on walls including in narrow widths/bands etc complete all specified and as directed |
| 24 | Preparation of old surfaces including brooming down with steel wire brushing scraping down soot's, moulds, moss and efflorescence, salts treating oil and greasy spots etc and applying one coat of premium quality paint |
| 25 | S&F of 1.60 mm thick Mild steel plate, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched, including round headed screws, clout nails or rivels and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc as required |
| 26 | Preparation of old painted surface and applying one coat of synthetic enamel paint on steel and iron surfaces over 10cm width or girth all as specified and as directed |
| 27 | M&L Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators, Partitions etc including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary overlap in the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P. brass/stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Charge. Note: Supply & fixing of 4 mm thick sheet glass or wire mesh be measured and paid separately. |
| 28 | S&F in repairs 12 mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame, Aluminium frame work, alround 6mm th teak fillets fixed in kitchen Cabinet or cupboards all as specified |
| 29 | M&L for complete removal of existing treatment of old treated surfaces of walls including washing, rubbing etc. and aapplying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. |
| 30 | Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil. |
| 31 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft / loose soil. |
| 32 | Excavation in trenches n exc 1.5 m wide & n exc 1.5 m depth; for foundation etc and getting out in soft/loose soil complete all as specified & directed. |
| 33 | M&L cement concrete 1:4:8 type D-2 (40 mm graded stone agg) as in foundations, filling & mass concrete complete all as specified & directed. |
| 34 | M & L hardcore of broken stone or boulders of gauge n.exc 63mm deposited spread and leveled in layer n.exc 15 cm thick, watered and rammed to a true surface complète all as specified. |
| 35 | M&L 75 mm thick cement concrete type D-2, 1:4:8 (using 40 mm graded crushed stone aggregate), as in sub base of floors. |
| 36 | M&L Machine Pre cast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-40 grade with grey cement and pigment as in ramps/Hardstandings complete all as specified and directed. |
| 37 | M&L Sand filling under floors or in foundations including watering and consolidation as sand cushioning complete all as specified and directed. |
| 38 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified & directed. |
| 39 | Removing excavated material n exc 50 m and depositing where directed. |
| 40 | M&L precast cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in block masonry with solid blocks, exc 10 cm in width in CM 1:6. |
| 41 | M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 incl finished even and fair all as specified and directed. |
| 42 | M&L preparing new surfaces plastered or unplastered on walls etc & applying two coats of cement base paint over cement base primer complete all as specified & directed. |
| 43 | M&L for contilever type open parking shed using hollow pipe section including rounding, moulding, shaping, finishing etc with following items:- |
| 44 | S&F Steel work in tubular trusses including special shaped washer etc. compiete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240. |
| 45 | S&F Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes of Fe 410 W, Gde E-250 quality A. |
| 46 | S&F 6mm thick multi wall virgin polycarbonate sheet, weighing min 1.45 Kg per Sqm suitable for cantilver shed, in selected colour, shade etc... |
| 47 | M&L 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs,pillars, window cills, cooking platforms and like in cement mortar (1:4), 15mm thick including pointing in white cement (1:2) using marble dust with admixture of pigment to match with the granite complete all as specified and directed |
| 48 | Excavating over areas not exc 1.50m deep and getting out in Soft/Loose soil |
| 49 | Removing excavated material exc 250 m but n exc 500 m and depositing where directed |
| 50 | Plain cement concrete 1:4:8, Type D2, using 40mm graded stone aggregate, 100 mm thick in sub-base concrete to pavement |
| 51 | Providing and laying at or near ground level factory made kerb stone of M-Cum 25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not more than 5 mm), including making drainage opening wherever required complete |
| 52 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & patter, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. |
| 53 | M & L Reinforced Cement Concrete 1:1 1/2 :3 Type A-1 using 20 mm graded crushed stone aggregate in foundations including rafts, footings and mass concrete complete all as specified and as directed. |
| 54 | Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and as directed. |
| 55 | Form work to sides of fdn and PB for rough finished surfaces of concrete complete all as specified and as directed. |
| 56 | S&F MS plates (plain or chequered) channels, square cut or notched forming holes, without any attachment conforming to Fe 410-W Gde E-250 Quality A |
| 57 | S&F 0.5mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete. |
| 58 | Mild steel TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and as directed. |
| 59 | S&F of 1.00 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 including welded or soldered joints are provided. |
| 60 | S&F Mild steel bolts diameter of neck in exc. 12 mm purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. Exc 30cm long |
| 61 | M&L for 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and as directed. |
| 62 | S & F 110mm dia PVC (SWR) bends |
| 63 | M & L for rendering 15mm thick in CM 1:6 on concrete surfaces finished even and smooth without using extra cement. |
| 64 | S&f Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165. |
| 65 | Wiring complete with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories incl GI/ MS branded sunken boxes of suitable module surface type on on wall/tresh including modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for the following :- (a) One light point controlled by one switch Note for Item No 1 :-(i) The earth wire for the points in the same circuit can be looped from point to point(ii) Earth wire shall be taken inside the conduit(iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring(iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring. |
| 66 | S&F LED batten suitable for indoor applications 18/20 Watts, 4 feet with extruded aluminium housing & integrated LED channel rectangular white arcylic cover complete with hanging provision accessories all as specified and directed. Make: Bajaj, Cat No.BCLAB 18 WH LED P or equivalent Makes & model. |
| 67 | S&F for modular switch ,single pole, one way 5/6 Amps, 230 Volts complete all as specified and directed by Engr-In-Charge. |
| 68 | S&F MCB SPN 240 volts 40 Amps complete all as specified and as directed |
| 69 | S&F MCB single pole 240 volts 6 to 32 Amps complete all as specified and as directed |
| 70 | S&F MCB DB SPN 4 way double door type 240 volts with 200 Amps rated busbar as specified and as directed. |
| 71 | S&F ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed |
| 72 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed. |
| 73 | M&L excavation in trenches in hard/dense soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables/errection of pole etc complete all as specified and as directed. |
| 74 | S&L sub class burnt bricks for cable protection complete as specified as directed |
| 75 | S&L XLPE insulated, screened, PVC bedded, galvanised steen strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm, 2 core laid in trenches/wall.. |
| 76 | S&F GI tubing light grade 32 mm bore with all fitting laid in trenches/walls/Roads for cable protection . Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysDec 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender