Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #58526461

Tender For Repair/ Maintenance And Replacement Of Unserviceable Ht Vcbs, Rmus, Four/Two Pole Structure And Other Connected Works Under Ge (S) Patiala

Issued by Statutory Bodies & Commissions/Committees · Patiala, Punjab
Tender Value
45 Lakhs
Estimated cost
Bid Submission
04 Dec 2026
13 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Patiala → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/ Maintenance And Replacement Of Unserviceable Ht Vcbs, Rmus, Four/Two Pole Structure And Other Connected Works Under Ge (S) Patiala

BOQ

Name of Work:- REPAIR/ MAINTENANCE AND REPLACEMENT OF UNSERVICEABLE HT VCBS, RMUS, FOUR/TWO POLE STRUCTURE AND OTHER CONNECTED WORKS UNDER GE (S) PATIALA
Sl. No. Item Description
1Preventive maintenace/ servicing of HT RMU of any make by dismantling of breaker mechanism checking the various critical setting in mechanism, busbar chamber, Electric short circuit indicator, current and earthfult relay, gas pressure/ density, manually operated mechanisms, fuses , fuse conister, feeder busbar intenal/external busbar, SF6 tank, LV compartment, auxiliary switch, interlocking lever, current transformer relay etc. checking of spring charging mechanism, checking of pole contact , greasing/ lubricating of mechanism moving parts, checking of contact pressure, alignment and adjusting the same, triping coil test trial , clibration of all type relay (rate including in this item ) & testing of RMU for smooth and correct fuctioning by authorized rep/Engineer of OEM company complete all as specified and directed by Engineer-in-Charge. Notes: 1. Cablibration report to be submitted by the contractor to Engineer-in-charge.(ii). Replacement of Spare parts shall be measured and paid separately under respective item.(iii). If major issue found with RMU which can not repair at site then it will be removed from existing site and transportation to workshop and shifting/transportation charge shall be paid under respective item.
2Preventive maintenace/ servicing of HT VCB of any make by dismantling of breaker mechanism checking the various critical setting in mechanism, busbar chamber, Electric short circuit indicator, current and earthfault relay, gas pressure/ density, manually operated mechanisms, fuses , fuse conister, feeder busbar intenal/external busbar, SF6 tank, LV compartment, auxiliary switch, interlocking lever, current transformer relay etc. checking of spring charging mechanism, checking of pole contact , greasing/ lubricating of mechanism moving parts, checking of contact pressure, alignment and adjusting the same, triping coil test trial, calibration of all type of relay (rate including in this item) & testing of RMU for smooth and correct fuctioning by authorized rep/Engineer of OEM/ company complete all as specified and as directed by Engineer-in-Charge. Notes: 1. Cablibration report to be submitted by the contractor to Engineer-in-charge.(ii). Replacement of Spare parts shall be measured and paid separately under respective item.(iii). If major issue found with RMU which can not repair at site then it will be removed from existing site and transportation to workshop and shifting/transportation charge shall be paid under respective item.
3Material and labour for replacement of Trip coil 110 volt Dc , copper winding 5 watt, 48.4 Ohm for 11 KV, 630 Amp RMU complete all as specified and as directed by Engineer-in-Charge.
4Material and labour for replacement of tripping shaft with spring and trip strip for 11KV, 630/800 AMP VCB complete all as specified and as directed by Engineer-in-Charge.
5Supply and fixing 11 KV, 630Amp HT bushing of RMU complete all as specified and as directed by Engineer-in-Charge.
6Material and labour for Repair to mechanism switch system of 11 KV, 630 Amp, RMU as per diagram for earthing ,interlocking, spring charging IS/IEC code complete all as specified and as directed by Engineer-in-Charge.
7Supply and filling SF6 gas to be filled in HT RMU's 11000 volt grade, 630 Amp S/IEC code complete all as specified and as directed by Engineer-in-Charge.
8Material and labour for replacement of U/S existing Relay – Self Powered Relay for 11 KV , 630 Amp, with protection of over current , under current , earth fault detection with min setting 1 to 3 sec for short circuit (Type: ADR 241-S) complete all as specified and as directed by Engineer-in-Charge.
9Material and labour for replacement of U/S VPIS Unit 9-15kV, 0-0.3 sec -CO--3mm, 630Amp, 11 KV, 25 KA, RMS 3 SEC complete all as specified and as directed by Engineer-in-Charge.
10Supply only operating Handle for RMU 11 KV, 630 Amp Standard length steelness steel complete all as specified and as directed by Engineer-in-Charge.
11Material and labour for replacement of manometer, 110/220 DC/AC volt for 11 kV, 630 Amp VCB complete all as specified and as directed by Engineer-in-Charge.
12Material and labour for replacement of Circuit breaker on/off Indication lamp ( Red,Yellow,Blue), 110/220 volt the 11 KV , 630 Amp VCB with electric fitting complete all as specified and as directed by Engineer-in-Charge.
13Supply only anti rusting spray suitable for mechanical moving parts of 11 KV, 630 Amp VCB and RMUs.complete all as specified and as directed by Engineer-in-Charge.
14Material and labour for replacement of Circuit breaker open/close push butto110/220 AC/DC as per existing make and model complete all as specified and as directed by Engineer-in-Charge. .
15Material and labour for replacement of Closing Coil, 110/220 volt AC/DC10/20 Amp current rating, 50 Hz ro 60 Hz for 11KV, 630 Amp VCB with electric fitting complete all as specified and as directed by Engineer-in-Charge.
16Material and labour for replacement of cable boot 11kV 630 amp for RMU complete with connection complete all as specified and as directed by Engineer-in-Charge.
17Material and labour for replacement of spring charging moto 110/220 volt AC/DC for 11 KV, 630 amp RMU complete with elecrtic wiring complete all as specified and as directed by Engineer-in-Charge.
18Material and labour for replacement of unservicable with new 11 KV dual Ratio dual core CTs with following ratio : 200-100/5-5A, Core Ci1: 1.0, 15Va and Core CI2: 5P10,15VA. complete all as specified and as directed by Engineer-in-Charge.
19Material and labour for replacement of unservicable with new 11 KV dual Ratio dual core CTs with following ratio : 400-200/5-5A, Core Ci1: 1.0, 15Va and Core CI2: 5P10,15VA complete all as specified and as directed by Engineer-in-Charge.
20Material and labour for replacement of unservicable with new 11KV/110 volt Boots 3 Single phase Fixed type PT With Core CI1: 1.0, Core 100VA complete all as specified and as directed by Engineer-in-Charge.
21Material and labour for replacement of unservicable with new Multifunction numeric protection Relay,curreint input: 4 inputs(dual-rated for 5A or 1A CTS), 3 voltage input, power supply 24-250 VDC , 2 line, 16 Character backliet LCB , flush mounting in a fully withdrawable compact 4 U case supports various protocols like DNP3,IEC 60870-5-103, overcurrent, earth fault, directional overcurrent , thermal overload Recloser , cold load pickup, breaker fuailure , voltage-restrained overcurrent etccomplete all as specified and as directed by Engineer-in-Charge.
22Material and labour for replacement of unservicable with new Master trip Relay , Vx 110-125 AC/DC for 11 KV, 630 Amp VCB complete all as specified and as directed by Engineer-in-Charge.
23Material and labour inreplacement of unservicable with new Trip Circuit supervision Relay,110/220 VDC/VAC, 630 Amp , 11 KV VCB complete all as specified and as directed by Engineer-in-Charge.
24Material and labour for replacement of unservicable with new Anit pumping 110 VDC for HT 11 KV 630 amp VCB complete with fitting and necessary connection complete all as specified and as directed by Engineer-in-Charge.
25Supply, fixing & connections, testing and commissionig up UPS for 30 min back up single phase AC input 160 to 260 V and out put 230 + 1% of capacity 3 KVA including suitable PCC foundation, and battery 12V & battery wooden stand etc complete all as specified and as directed by Engineer-in-Charge.
26Material and labour for replacement of unservicable with new Breaker control switch,1-6 amp for 11 KV 630 Amp VCB complete with electric connection complete all as specified and as directed by Engineer-in-Charge.
27Material and labour for replacement of unservicable with new Emergency push button,as per existing make and mode complete all as specified and as directed by Engineer-in-Charge.l.
28Material and labour for replacement of unservicable with new LED 110/220 VDC, for VCB 11 KV, 630 Amp panel complete all as specified and as directed by Engineer-in-Charge.
29Material and labour for replacement of unservicable with new 3 Pin Plug - Socket,110/220 VDC, for VCB 11 KV, 630 Amp panel complete all as specified and as directed by Engineer-in-Charge.
30Material and labour for replacement of unservicable with new Toggle switch, 110/220 VDC, for VCB 11 KV, 630 Amp panel complete all as specified and as directed by Engineer-in-Charge.
31Material and labour for replacement of unservicable with new Hooter , 110/220 VDC, for VCB 11 KV, 630 Amp panel complete all as specified and as directed by Engineer-in-Charge.
32Material and labour for replacement of unservicable with new Door Switch, 110/220 VDC, for VCB 11 KV, 630 Amp panel complete all as specified and as directed by Engineer-in-Charge.
33Material and labour for replacement of unservicable with new Space heater with thermostat complete all electric wiring 110/220 VDC, for VCB 11 KV, 630 Amp panel complete all as specified and as directed by Engineer-in-Charge.
34Material and labour for replacement of unservicable with new Control MCB 110/220 VDC, for VCB 11 KV, 630 Amp panel complete all as specified and as directed by Engineer-in-Charge.
35Supply and fixing in replacement of unservicable with new copper Jaw contact for 11 kV 630/800 Amp VCB complete all as specified and as directed by Engineer-in-Charge.
36Supply and fixing in replacement of unservicable with new stainless steel cgl VCB mechanisum powder coating 11KV, 630/800Amp VCB powder coating complete all as specified and as directed by Engineer-in-Charge.
37Supply and fixing inreplacement of unservicable with new VCB epoxy pole assemble for 11 KV 630/800 Amp VCB complete all as specified and as directed by Engineer-in-Charge.
38Supply and fixing in replacement of unservicable with new CGL VCB rack in rack out gear 11KV 630 Amp complete all as specified and as directed by Engineer-in-Charge.
39Supply and fixing in replacement of unservicable with new circuit breaker PT 11 KV, 630/800Amp VCB copper Spout complete all as specified and as directed by Engineer-in-Charge.
40Supply and fixing in replacement of unservicable with new VCB tulip jaw contact 11KV, 630/800Amp , 63 KA complete all as specified and as directed by Engineer-in-Charge.
41Supply and fixing in replacement of unservicable with new circuit breaker system control 11 KV, 630 Amp complete all as specified and as directed by Engineer-in-Charge.
42Supply and fixing in replacement of unservicable with new copper cluster contact for HT 11KV 630/800 Amp VCB complete all as specified and as directed by Engineer-in-Charge.
43Supply and fixing in replacement of unservicable with new spring charging motor11 KV 630/800 Amp VCB complete all as specified and as directed by Engineer-in-Charge.
44Supply and fixing in replacement of unservicable with new HT breaker vaccum interrupter rated Voltage 12 KV, 630 Amp, Short circuit MVA 350 complete all as specified and as directed by Engineer-in-Charge.
45Supply and fixing in replacement of unservicable with new kycee TNC switch 25 Amp, manual as per existing make and model or equivalent to other make Ashida /CG/Schneider/ABB.
46Supply and fixing in replacement of unservicable with new EMR 151 master trip Relay for 11 KV, 630 amp VCB as per existing make and model or equivalent to other Make: Ashida /CG/Schneider/ABB.complete all as specified and as directed by Engineer-in-Charge.
47Shifting after disconneting carefully unserviceable existing RMUs any make and type with all connected items/ accessories and deposit to E&M Store yard including trasportation and loading unloading upto EM Yard complete all as specified and as directed by Engineer-in-Charge.
48Supply and fixing in replacement Digital protective relays comprising of 3 Phase over current plus earth fault relay with high set operational with 24 volt to 110 volts AC / DC, Dc dual rated CT model MC 61A as per Cat Part no-MC 61 Anx of L&T including complete wiring with suitable size wire as per existing and fixing arrangement complete all as specified and as directed by Engineer-in-Charge.
49Supply and fixing in replacement Digital protective relays comprising of over current plus earth fault relay with high set operational with 24 volt to 110 volts AC / DC, Dc dual rated CT model ADR 131A of Ashida /CG/Alstom/Schneidermake including complete wiring with suitable size wire as per existing and fixing arrangement complete all as specified and as directed by Engineer-in-Charge.
50Material and labour for cable jointing kit 11 KV (earthed) grade cable for indoor termination heat shrinkable type joint complete with jointing material and all accessories for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and as directed by Engineer-in-Charge.
51Material and labour for cable jointing kit 11 KV (earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and all accessories for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and as directed by Engineer-in-Charge.
52Material and labour for laying in trenches, along poles/over poles XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor,11000 volts Earthed grade, cross sectional area 240 Sqmm 3 core including testing and commissioning and taking out/down u/s cable from trenches/ along/over poles complete all as specified and as directed by Engineer-in-Charge.
53Material and labour for laying in trenches, along poles/over poles XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor,11000 volts Earthed grade, cross sectional area 120 Sqmm 3 core including testing and commissioning and taking out/down u/s cable from trenches/ along/over poles complete all as specified and as directed by Engineer-in-Charge.
54Material and labour for laying in trenches, along poles/over poles XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor,11000 volts Earthed grade, cross sectional area 95 Sqmm 3 core including testing and commissioning and taking out/down u/s cable from trenches/ along/over poles complete all as specified and as directed by Engineer-in-Charge.
55Material and labour for replacement old rusted galvanized iron pipe 100 mm bore light grade laid in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and as directed by Engineer-in-Charge.
56Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for laying of cable, pipes and for poles/stay and struts etc and getting outcomplete all as specified and as directed by Engineer-in-Charge.
57All as per serial item No. 56 here-in- before but depth exceeding 1.5m but not exc 3.0 m complete all as specified and as directed by Engineer-in-Charge.
58Returning, filling in soft/loose soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by Engineer-in-Charge.
59Removing excavated surplus soil to a distance not exceeding 50 meter and depositing where directed at a level not exc. 1.5 meter above the starting point complete all as specified and as directed by Engineer-in-Charge.
60Material and labour for laying,spreading dry fine river sand in trenches as cushioning for ptotection of cable, 8 cm before laying of cable and 15 cm after laying of cable complete all as specified and as directed by Engineer-in-Charge. Note:- For payment punned depth will be measured.
61Supply and laying unreinforced precast concrete cable cover, class HVP,type-1, 300mm x180mm x40mm laid flat adjacent and abutting to each other across the length of cable laid dry complete all as specified and as directed by Engineer-in-Charge.
62Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for rerouting and finding of the fault in HT underground cable and returning filling the same after rectification of the cable fault in any type of soil complete all as specified and as directed by Engineer-in-charge .Notes :1. Item dry fine sand shall be measured and paid separatelly in respective items.2. Retrieved reusable bricks will be used for protection of cable.
63Dismantling steel poles/ struts, any size after Excavation, demolition of PCC foundation and disconecting of cross arm and insulators, conductor any size of overhead line complete all as as directed by Engineer-in-charge
64Supply and Errecting steel tubular swaged welded pole complete with cast iron/MS base plate 6mm thick and of size 300x300mm, final taper, pole cap, bolts, nuts, washers & screws etc. pole made out of ERW M.S. tubing conforming to IS-2713 part-II type 410 SP-55 (11.0 metre long) including of holes of reqd Nos and size for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting three signal red colour bends at lower portion of exposed pole starting from plinth block , each band of 300mm height at 300mm spacing, painting pole No the black paint by stenciled letters/figures of 8cm height complete all as specified and as directed by Engineer-in-charge . Note: Excavation, earth work and PCC in foundation and coping will be measured and paid separatly in respected items.
65Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed by Engineer-in-charge
66Material and labour for cement concrete type D-2 (1:4:8) using 40 mm graded aggregate as in founations of poles/stays/struts, filling and mass concrete etc complete all as specified and as directed by Engineer-in-charge
67Material and labour for cement concrete type B-1 (1:2:4) using 20 mm graded aggregate for coping of poles / says/strutus etc complete all as specified and as directed by Engineer-in-charge
68Material and labour for cement concrete 1:3 :6 type C-2 using 40 mm graded stone aggregate for foundation of poles / stays /strutus, filling and mass concrete etc complete all as specified and as directed by Engineer-in-charge
69Material and labour for repalcement of aluminium conductor steel reinforced(rabit) conductor including binding wire and jumper and connected with PG clamp made out of aluminium alloy accodring to IS-617complete all as specified and as directed by Engineer-in-charge
70Material and labour for replacement of unserviceable stay assembly comprising of MS stay plate of size 30cmx30cmx6mm thick for HT pole, stay rod with nuts 215cm long ,20mm dia , MS/GI stay bow 40cm in length with 2 Nos GI thimbles, galvanized stay wire standard size 7/3.5mm of suitable length, loop insulator size 65x90mm clearance of hole 16mm & other accessories including excavation and earth work , cement concrete and loop insulators all as shown in SSR Part-1 plate No-1 complete all as specified and as directed by Engineer-in-charge Note :- MS clamps will be measured & paid separately in respected items of this schedule.
71Material and labour for replacement of switch air break, gang operated, triple pole mechanically operated mounted on mild steel galvanized frame with operating rod of 20 mm bore medium grade ISI marked galvanized iron pipe worked from ground level for HT 11KV outdoor for horizontal or vertical mounting insulators and current rating 400 Amps including nuts,bolts and washers etc of required size, locking arrangement with locks and applying two coats of synthetic enamel paint over a coat of red oxide primer over mild steel work and making necessary electric connections complete all as specified and as directed by Engineer-in-charge
72Supply and fixing in replacement of single disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type, white, brown or green, with tension clamps for conductor, working pressure 11000 volts complete all as specified and as directed by Engineer-in-charge
73Supply and fixing in replacement of pin type, porcelain, vitreous, white, brown or green insulator, including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150 mm height, 150 mm dia for 11000 Volt grade complete all as specified and as directed by Engineer-in-charge
74Supply and fixing in replacement of post insulator, porcelain, vitreous 150 mm high and 255 mm dia ball and socket type, white, brown or green, working pressure 11000 volts complete all as specified and as directed by Engineer-in-charge
75Material and labour for replacement of unserviceable cross arms bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed inclusive of one primer coat ,one under coat and one finishing coat complete all as specified and as directed by Engineer-in-charge
76Material and labour for cable jointing kit 11 KV (earthed) grade cable for straight through heat shrinkable type joint complete with jointing material and all accessories for 3 core XLPE armoured aluminium conductor cable of size 240 to 400 sqmm complete all as specified and as directed by Engineer-in-charge
77Material and labour for cable jointing kit 11 KV (earthed) grade cable for straight through heat shrinkable type joint complete with jointing material and all accessories for 3 core XLPE armoured aluminium conductor cable of size 120 to185 sqmm complete all as specified and as directed by Engineer-in-charge
78Supply and fixing in replacement of sercvice cable 1100volts grade heavy duty cable PVC insulated multistranded aluminium conductor, served with innersheathing of PVC tape and overall PVC sheathed inservice connections suspendedby one twin core cable of size 16 sqmm 2 core flat complete all as specified and as directed by Engineer-in-charge
79Supply and fixing in replacement of sercvice cable 1100volts grade heavy duty cable PVC insulated aluminiumconductor, served with innersheathing of PVC tape and overall PVC sheathed inservice connections suspendedby insulating hangers not more than 1 metre apart including 4mm suspensionwire, one twin core cable of size 10 sqmm 2 core flat complete all as specified and as directed by Engineer-in-charge.
80Supply and fixing in replacement of unservicebale wall mounted bus bar chamber current rating 100 Amp, 4 way, 440 volt, bus bar made of ETP grade copper outdoor type complete all as specified and as directed by Engineer-in-charge
81Earthing complete with Galvanized steel earth plate 600 x 600 x 6.0 mm buried directly in ground (earth pit not less then 2.25 Mtr deep below ground level) with top edge of the plate not less then 1.5 Mtr below normal ground level connected to GI strip of size 32x6 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel incl excavation and earth work, GI pipe light grade 40 mm bore for protection of GI strip from earth electrode to and incl the supplying and lying charcoal dust, common salt, PCC 1:3:6 type CI (using 20 mm graded crushed stone aggregate) as in chamber and MS angle iron frame 40 x 40 x 3mm and RCC cover 40 mm thick 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) reinforced with 8 mm dia. TMT bars @ 75mm c/c both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No. 3 of SSR Part I of 2009 and connected to earth test point incl testingcomplete all as specified and as directed by Engineer-in-chargeNote:- The unit rate includes earth strip and protection pipe upto maximum 7.5 metre from earth plate, earth point/test point.
82Material and labour earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron wire 4.0mm dia size by means of GI bolts, nuts, check nuts and washers, GI wire protected by galvanized steel pipe 20 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc.complete all as specified and as directed by Engineer-in-charge.Note: The unit rate includes earth wire and protection pipe upto (maximum 7.5 metre from earth plate/ earth point/test point. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58526461
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 04-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maintenance And Replacement Of Unserviceable Ht Vcbs, Rmus, Four/Two Pole Structure And Other Connected Works Under Ge (S) Patiala
Basic Detail
Tender No CWE/PAT/T-72/2026-27
Bidding Type Tender
Location
City Patiala
State Punjab
Key Dates
Publish Date 13 Nov 2026
Submission Date 04 Dec 2026
Open Date 07 Dec 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Not Available
Document List
BOQ_895447.xls
c87e834a-2336-4d6d-9c15-637e01f4d8e9.html
Tender722627.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Dec 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_895447.xls

html

c87e834a-2336-4d6d-9c15-637e01f4d8e9.html

pdf

Tender722627.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender