Defence Statutory Bodies & Commissions/Committees Closing in 14 days TDR #58526417

Tender For Repair / Replacement Of Lightining Arrestors, Earthings, God, Pole Painting, Cable Incl Kits, Lt Panels Of Various Electrical Installations Under Ge Golconda.

Issued by Statutory Bodies & Commissions/Committees · Hyderabad, Telangana
Tender Value
40 Lakhs
Estimated cost
Bid Submission
05 Dec 2026
14 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Replacement Of Lightining Arrestors, Earthings, God, Pole Painting, Cable Incl Kits, Lt Panels Of Various Electrical Installations Under Ge Golconda.

BOQ

Name of Work:- REPAIR / REPLACEMENT OF LIGHTINING ARRESTORS, EARTHINGS, GOD, POLE PAINTING, CABLE INCL KITS, LT PANELS OF VARIOUS ELECTRICAL INSTALLATIONS UNDER GE GOLCONDA.
Sl. No. Item Description
1BOQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) File No 8163/E8 Tender Inviting Authority: GARRISON ENGINEER GOLCONDA Name of Work: REPAIR / REPLACEMENT OF LIGHTINING ARRESTORS, EARTHINGS, GOD, POLE PAINTING, CABLE INCL KITS, LT PANELS OF VARIOUS ELECTRICAL INSTALLATIONS UNDER GE GOLCONDA. Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of work Item Code / Make No or Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder including all TaxesRs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc. Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES
2Supply, fabricate and fix cross arms any size fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed.
3S&F danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts, nuts of approved size for HT 25x20 cm size including dismantling old one complete all as specified and as directed.
4S&F danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts, nuts of approved size for LT 20x15 cm size including dismantling old one complete all as specified and as directed.
5Dismantling air break gang operated switches triple pole vertical/ horizontal mounted including isolators and operating mechanism for replacement complete all as specified and as directed.
6S&F GOD switches air break gang operated, triple pole mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level, for current rating up to 400 Amps complete all as specified and as directed.
7Taking down old DO fuse unit S &F expulsion fuse single phase above 50 & up to 100 AMPS capacity, 11000 Volts complete all as specified and as directed.
8Taking down existing unserviceable Lightning arrestor and S&F lightning arresters expulsion type complete with all fittings transmission class, discharge capacity 10 KA suitable for 11000 Volts line complete all as specified and as directed.
9M&L for replacement of galvanized iron strip 32x6 mm buried in ground or fixed on pole with all accessories including dismantling old one complete all as specified and as directed.
10M & L for Earthing complete with Galvanized Steel earth plate of size 60x60cmx6mm thick electrode and 32x6mm GI strip as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to 32x6mm earth strip by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.5 of SSR Part-I, connected to earth test terminal point all as specified or as indicated including testing on completion (Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc. all as required at site for complete earthing) and testing after completion complete all as specified and as directed.
11M&L for cable jointing kit for 11 KV (Earthed) grade XLPE cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for size 3 core 120 to 185 Sqmm including testing after jointing complete all as specified and as directed.
12M&L for cable jointing kit for 11 KV (Earthed) grade XLPE cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for size 3 core 50 to 95 Sqmm including testing after jointing complete all as specified and as directed.
13Excavation in trenches n.exc 1.5mtr wide and not exc 1.5mtr depth and getting out in soft/loose soil complete all as specified and as directed.
14Excavation in trenches exc 1.5 mtr depth and not exc 3mtr depth for pole / cable / foundation etc including getting out in soft /loose soil complete all as specified and directed.
15Returning and filling in of excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and as directed.
16Removal of surplus soil not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed.
17M&L for Sand cushioning/sand covering for underground cable protection complete all as specified and as directed. Note: Punned thickness only will be measured and paid.
18Supply and laying sub class 'B' bricks of old size (standard size as per local availability) laid along alignment of cable as protection to cable in trenches complete all as specified and directed.
19Supply, erecting and fixing in repair true vertical position, steel tubular swaged pole 410 SP-55 (11.0 metres long), complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally up to planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint and including making alternate white and black strips 30 cms height (05 Nos strips) numbering the poles by 2\\" height 06 Nos letters complete all the metallic surfaces all as specified and directed including dismantling of old one.
20Supply & Laying in trenches or fixing on wall or passing through pipe or in cable ducts, 1100 volts grade XLPE insulated , armoured, electric power cables (heavy duty) with aluminium conductor of the following size including dismantling old one. Note: The rate quoted inclusive of termination at ends with suitable aluminium lugs ,Cramping ,Glanding wherever required including taking out old unserviceable cable complete all as specified and as directed for cable of 16 Sqmm 4 core
21All as per item No. 19 above but for 25 Sqmm 4 core
22All as per item No. 19 above but for3.5 core 35 Sqmm
23All as per item No. 19 above but for 3.5 core 50 Sqmm
24All as per item No. 19 above but for 3.5 core 70 Sqmm
25All as per item No. 19 above but for 3.5 core 95 Sqmm
26All as per item No. 19 above but for 3.5 core 120 Sqmm
27All as per item No. 19 above but for 3.5 core 150 Sqmm
28All as per item No. 19 above but for3.5 core 185 Sqmm
29Material & labour for old painted rusted steel/iron surface of 9mtr/11 mtr steel tubular electric pole including cross arms other accessories/fittings by scraping properly and applying two coats of aluminium paint over a coat of primer including rewriting pole number using suitable tint paint making circular shape background and height using synthetic enamel paint up to 80cm height from the top of coping with multicolour strip as per code complete all as specified and directed.
30Providing, supplying, fixing, testing and commissioning of fire safety equipment for distribution substation, including 6 kg ABC type Dry Chemical Powder (DCP) fire extinguishers, 9 litre Foam (AFFF) type fire extinguishers, 2 kg CO₂ fire extinguishers, fire buckets with stand (ISI marked) including sand filling, fire safety signage boards (reflective/glow type as per IS/NBC standards), and MS powder coated fire extinguisher stands/cabinets, complete in all respects including mounting, installation, initial charge, accessories, labour, transportation, testing and commissioning as per approved drawings and statutory requirements complete all as specified and as directed.
31S&F of MS steel angle iron work as in struts and posts in fencing including cutting tops to shape as directed ,drilling holes notching for wire any flat iron fillets (for securing wire mesh and any wire type) including drilling, bolting or riveting and embedding in angle iron and screwing etc similar work confirming to Fe 410-0 or Fe 310-0 complete all as specified and as directed.
32Dismantling of existing damaged fencing and supply & fixing MS galvanized PVC-coated chain link fencing with PVC coating , fabricated from 4 mm diameter wire with 50 mm × 50 mm mesh spacing, weighing not less than 3 kg/m², complete with all necessary accessories including line wires, hard rails, straining bolts, tension bands, binding wire, clamps, cleats, nuts, bolts, washers, tie wires, and other fixing accessories required for proper installation. The fencing shall be diagonally pinned wherever specified and securely fixed to MS posts/rails by bolting or tying as required. All drilling, cutting, fitting, tightening, and erection work shall be carried out complete in all respects, and as directed by the Engineer-in-Charge.
33Dismantling of existing damaged Post, and Supply and fixing Hot-Dip Galvanized Steel Square Hollow Section (SHS) fence posts of size 60 × 60 × 3 mm, having an overall length of 2700 mm (including the embedded portion), suitable for supporting 2100 mm high welded wire mesh fencing. The post shall be fabricated from structural steel SHS complete with welded top cap, galvanized fixing clamps/brackets for mesh panels, galvanized bolts, nuts and washers, and all accessories required for complete installation. The post shall be hot-dip galvanized after fabrication in accordance with relevant standards complete all as per directed by Engineer-in-Charge.
34Dismantling of existing damaged Double-Leaf Mild Steel (MS) Entrance Gate and supply and fix 2000 mm clear opening × 2100 mm height, fabricated from 100 × 100 × 4 mm SHS gate posts and 60 × 60 × 3 mm SHS outer frame with 40 × 40 × 3 mm SHS intermediate members. The gate shall be in filled with welded wire mesh of 50 × 100 mm aperture made from 5 mm diameter GI wire, securely fixed to the gate frame. The complete gate assembly, including posts, frame, brackets and fittings, shall be hot-dip galvanized after fabrication. The gate shall be provided with heavy-duty adjustable hinges, central locking arrangement, sliding tower bolts/drop bolts, stopper, locking plate, hold-fast arrangements, galvanized bolts, nuts, washers and all accessories required for complete all as specified and as directed.
35Supply and spread stone metal graded aggregate of size 40 mm at transformer yard complete all as specified and as directed.
36M&L for Plain Cement Concrete (PCC) of nominal mix 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone aggregate) of D2 with 40 mm nominal size) as levelling course below fence/gate post foundations, including mixing, placing, compacting, curing and finishing including dismantling the foundation & coping of poles complete all as specified and as directed.
37M & L for Providing and laying Cement Concrete of nominal mix 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone aggregate of 20 mm nominal size) for embedding and fixing fence/gate posts, including mixing, placing, vibrating, compacting, finishing, curing and all incidental works complete all as specified and as directed.
38Material and Labour Pre-cast cement concrete block masonry type C1 1:3:6 using 20mm stone aggregate with solid blocks, exc 10 cm in width and setting mortar 1:6 complete all as specified and as directed.
39Material and Labour for rendering 15 mm thick on exposed brick masonry/block masonry/RCC surfaces of transformer foundation and plinth, including preparation of surface, raking out joints where required, cleaning, wetting, applying plaster to true line, level and plumb, finishing smooth and even without extra cement complete all as specified and as directed.
40M&L for PCC 1:3:6 type C2 using 40 mm graded aggregate for coping of poles and stay including form work and dismantling the foundation & coping of poles complete all as specified and as directed.
41Clearing of bushes/small plants up to root level around and surroundings areas E/M installations (i.e. Two Pole/ Four structures, outdoor-substation yards, pump house & STP installations etc) including surface dressing n.exc 15 cm deep and removing debris to a distance n.exc 50m complete all as specified and as directed
42Supply, installation, testing and commissioning of 6 m high Steel pole solar LED street light complete with 45 W LED luminaire, 150 Wp solar PV module, 12.8 V 42 Ah LiFePO₄ battery, MPPT charge controller, cabling, earthing, clamps, hardware and all other accessories required for proper operation, complete in all respects as per approved specifications complete all as specified and as directed.
43M & L for Providing and constructing RCC foundation for transformer of size varying from 2.5 m × 2.5 m to 3.0 m × 3.0 m with a minimum foundation depth of 1200 mm below finished ground level, including site clearance, excavation in all types of soil, dressing, trimming, dewatering wherever required, disposal of surplus excavated earth, providing and laying 100 mm thick PCC (1:4:8) bed, constructing RCC foundation/plinth of required grade (minimum M20) including reinforcement steel, cantering, shuttering, vibration, finishing and curing, providing and fixing anchor bolts, embedded inserts and base fixing arrangements, backfilling and compaction, and providing 1200 mm wide plinth protection around the transformer plinth consisting of 75 mm thick compacted brick aggregate/stone ballast and 50 mm thick PCC (1:3:6) finished with an outward slope of 1 in 50 and brick edging complete. The work shall also include disconnecting the existing HT and LT connections, dismantling the transformer from the existing foundation, shifting, positioning and mounting the transformer on the newly constructed plinth, reconnecting all existing HT and LT connections including jumpers/cable terminations, tightening of all electrical and mechanical connections, replacement of minor consumables such as lugs, nuts, bolts, washers and insulation tape wherever required, testing, checking, commissioning and making the transformer ready for service. The rate shall include all labour, materials, cement, sand, aggregates, reinforcement steel, water, formwork, anchor bolts, tools and plants, lifting equipment, transportation, loading, unloading, curing, wastage, , safety measures and all incidental works complete as per approved drawings, relevant IS Codes and as per approved specifications complete all as specified and as directed.
44M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5/ 4 core 25 to 50 sq.mm complete all as specified and as directed.
45All as per Item No.43 herein before but for cable of size 3.5 core 70 to 150 sq.mm.
46All as per Item No. 43 herein before but for cable of size 3.5 core 185 to 400 sq.mm.
47M&L for heat shrinkable end termination joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5/ 4 core 16 to 50 sq.mm complete all as specified and as directed.
48Design, Fabrication, supply, installation, commissioning and testing Double Door Panel board manufactured from CPRI approved firm with canopy head, out door, cubical type panel board of over all min dimension 1800 mm (H) × 1200 mm (W) × 450 mm (D) fabricated with 3.0mm thick CRCA sheet on mild steel angle iron 50X50X6 mm thick frame, totally enclosed type dust & vermin proof back side open-able fixed with hinged shutter and front side open-able with hinged shutter and locking arrangement for individual MCCBs/MCBs , powder coated finished both internally and externally suitable for 415Volt AC 50 Hz 3 Phase 4 wire system by means of Aluminium bus bar of 800 Amps Capacity (Main bus bar ) and 600 Amps Loop Bus bar with coloured insulating tape/sleeves mounted on porcelain or synthetic insulators with provision for fixing MCCBs/MCBs necessary inter connections with Aluminium bar/strip duly coloured code insulation and providing under mentioned equipments & accessories including connections of all out going/in coming existing/New cables of required size and including PCC foundation in 1:3:6, type C1 of 0.5 mtrs height above GL and 0.30mtrs below GL including necessary earth work and dismantling of old unserviceable one complete all as specified and as directed with including the following :- (a) INCOMING: MCCB 4 pole 400Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals - 01No OUTGOING: (a) MCCB 4 pole 250Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals -01 Nos (b) MCCB 4 pole 160 Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals -02 Nos (c) MCCB 4 pole 100 Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals -02 Nos(d) O/G MCB TPN 63Amp, 10KA,C curve - 02 Nos (d) Indicating lamp LED type 240V 50 Hz AC -one set of 3 .
49Supply & fixing in repairs of MCCBs of following current carrying capacity including necessary connecting terminals to bus bar, nut bolts etc complete all as specified and as directed.(a) 125 Amps, 3P,Adjustable type, 415 V MCCB, 16KA rating
50All as per item No. 48 above but for 100 Amps, 3P, 415 V MCCB, 16KA rating
51All as per item No. 48 above 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 36 KA, 400 A rated
52All as per item No. 48 above 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 36 KA, 250 A rated
53All as per item No. 48 above 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 26 KA, 200 A rated
54All as per item No. 48 above 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 26 KA, 160 A rated Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58526417
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 05-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Replacement Of Lightining Arrestors, Earthings, God, Pole Painting, Cable Incl Kits, Lt Panels Of Various Electrical Installations Under Ge Golconda.
Basic Detail
Tender No 8163/E8
Bidding Type Tender
Location
City Hyderabad
State Telangana
Key Dates
Publish Date 13 Nov 2026
Submission Date 05 Dec 2026
Open Date 07 Dec 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
8163NIT.pdf
8163Tender.pdf
819affee-bec5-4999-8d80-7eafec3f086e.html
BOQ_895898.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Dec 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
pdf

8163NIT.pdf

pdf

8163Tender.pdf

html

819affee-bec5-4999-8d80-7eafec3f086e.html

xls

BOQ_895898.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender