Water Resources and Irrigation Government Departments Closing in 6 days TDR #58526237

Tender For Upgradation And Renovation Of Various Infrastructure At Jkwrra Building Complex Satwari.

Issued by Government Departments · Jammu, Jammu and Kashmir
Tender Value
1.64 Crore
Estimated cost
Bid Submission
21 Nov 2026
6 days left
EMD
3.28 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Upgradation And Renovation Of Various Infrastructure At Jkwrra Building Complex Satwari.

BOQ

Name of Work:- Upgradation and renovation of various infrastructure at JKWRRA Building Complex Satwari.
Sl. No. Item Description
1Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
2Demolishing brick work manually/by mechanical means includingstacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge. In cement mortar
3Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m. (stacks of cleaned bricks shall be measured) : In cement mortar
4Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge:1:3:6 or richer mix (i/c equivalent design mix)
5Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge
6Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:All kinds of soil :50 meter beyond 1 m from cutting edge
7Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead. For thickness of tiles 10 mm to 25 mm
8Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
91:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
10Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level. 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
11Reinforced cement concrete work in walls (any thickness including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
12Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
13Centering and shuttering including strutting, propping etc. and removal of form for: Column
14Plinth Beam
15Suspended Slab
16Foundation: For plinth at bottom of chain link
17Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand)
18Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
1912mm Cement plaster of mix:1 : 4 ( 1 cement : 4 coarse sand)
20Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete
21Flooring with marble stone of specified thickness as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement:4 coarse sand) laid and jointed with grey cement slurry including rubbing, polishing and curing complete with:Black zebra
22Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorptionmless than 0.08% and conforming to IS: 15622, of approved brand and manufacturer, in all colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of tile 800x800 mm
23Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shades, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of tile 800x800 mm
24Size 600x600mm Corridor
25Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
26Providing and laying common burnt clay (non modular) brick tiles of class designation 10 over mumty roofs grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat.
27Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design. In 75x75 mm deep chase.
28Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound@ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg./sqm. and coarse sand @1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately).
29Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.
30Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead. With cement mortar 1:4 (1 cement : 4 coarse sand)
31Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2mm thick
32Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 meters lead :of area of 3 sqm. and below
33Dismantling wood work in frames, trusses, purlins and rafters upto 10 meters span and 5 meters height including stacking the material within 50 meters lead :Of sectional area below 40 sqcm.
34Providing and fixing factory made PVC door frames of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and jointed with two numbers of 150mm long brackets of 15x15mm MS square tube, the vertical door profiles to be reinforced with 19x19mm MS square tube of 19 gauge, EPDM rubber gasket weather seal to be provided throughout the frame. The door frame to be fixed to the wall using MS screws of 65/100mm size complete as per manufacturers’ specifications and directions of engineer-in-charge
35Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75 mm x 30 mm having wall thickness 5 mm. The styles, top & bottom rails shall have one side wall thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with M.S. tubes ofsize 33 mm x 17 mm x 1 mm, painted with primer , all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and the rails with a cavity, to receive single piece extruded 5 mm PVC sheet as panel. The styles and rails will be mitred cut and joint with the help of PVC solvent cement &self driven self tapping screws. Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement &self driven self tapping screws of size 100 mm x 8 mm complete as per manufacturer’s specifications and direction of Engineer-in-charge. Decorative finish (both side wood grained finish)
36Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto1.75 sqm).
37Providing, fixing and applying Plaster of Paris (POP) false ceilingconsisting of frame work made with 50mm sq M.S. tubes of 18 G thickness as main runner at 600 mm c/c both ways, suspended/ supported with M.S. flats 25x4 mm from existing R.C.C. slab, finished smooth to line and level including necessary supports, scaffolding etc. as required and also including applying a coat of red oxide zinc chromate primer over the M.S. frame work and suspenders complete.Including providing and fixing expanded metal of size 5.25 mm x 1.25 mm thickness welded to main runners and applying POP (calcium sulphate semi hydrate variety) to the expanded metal of thickness not less than 10 mm
38Providing and Fixing 15 mm thick densified tegular edged eco-friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanizing @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main ’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on Perimetre wall angle pre-coated steel size (24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws@ 230 mm interval and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture (Spin tone / Cosmos/hexa) in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanized steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’ , bottom exposed with 24 mm of all T-sections shall be prepainted with polyester baked paint, for all heights, as per specifications, drawings and as directed by engineer-in-charge. Note: - Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non - combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/m 0 KC.
39Providing and fixing thermal insulation with specified wool and density conforming to IS: 8183, 50 mm thick, wrapped in 200G Virgin Polythene bags placed over existing false ceiling and held in position by crisscrossing GI wire.With resin bonded fiber glass wool with density 16 kg/cum
40Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level and above. Thermo-Mechanically Treated bars of grade Fe-500D or more.
41Painting with silicon and acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces: Two coats
42Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.
43Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ liter of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two Coats
44Finishing walls with 100% Premium acrylic emulsion paint havingVOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/10 sqm. Over & including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
45Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.M.S. tube
46Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
47Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work.
48Dismantling C.I. or asbestos rain water pipes with fittings and clamps including stacking the material within 50 meters lead :75 to 80 mm dia pipe.
49100 mm dia pipe.
50Regrading terracing of mud phaska covered with tiles or bricks, in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud phaska to proper slope, relaying mud plaster gobri leaping and tiles or bricks, grouted in cement mortar 1:3 (1 cement: 3 fine sand), including replacing unserviceable tiles or bricks with new ones and disposal of unserviceable material to the dumping ground (the cost of the new tiles or brick excluded) within 50 meters lead.
51Providing and fixing decorative acoustic Wood Plastic Composite (WPC) Fluted Wall Panels of minimum 18–25 mm thickness over galvanized steel/aluminium framework using stainless steel screws and proprietary fixing clips. The panels shall be fixed over an independent framework of GI sections of minimum 0.55 mm thickness (or aluminium framework where specified), securely anchored to the wall with approved dash fasteners, maintaining a minimum 25 mm clear air cavity between the existing wall and panelling forfilling with rockwool . The framework shall be placed at a maximum spacing of 600 mm centre-to-centre or as recommended by the manufacturer. The panels shall be termite-proof, waterproof, weather resistant and dimensionally stable with decorative wood finish. Necessary aluminium edge trims, end caps, mouldings and all fixing accessories complete. Approved Makes: Alstone, Ecoste, CenturyPly (WPC Division), Durian, Greenpanel WPC, Kosha, Advance Decorative, equivalent approved make. (LMR)
52Providing and fixing specified wood frame work consisting of battens 50x25mm fixed with rawl plug and drilling necessary holes for rawl plug etc, including priming coat complete:Second Class Kail Wood
53Providing and fixing in wall lining of specified medium density board, pre-laminated one side decorative lamination other side balancing lamination Grade I, exterior grade, with necessary fixing arrangement and screws etc. complete. MDF board IS: 1998 marked- 18 mm thick
54Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) For fixed portion Powder coated aluminum (minimum thickness of powder coated 50 microns)
55For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.) Powder co ated aluminum (minimum thickness of powder coated 50 microns)
56Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-incharge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on both side.
57Providing and fixing Brass 100mm mortice latch and lock with 6levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete
58Providing and fixing steel roller for UPVC sliding door with necessary screws etc. complete.
59Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-incharge.Made of G.I. wire of dia 4 mm
60Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded framewoork for chain link fencing
61Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. The structural framework shall comprise RHS 80 × 40 × 3.2 mm for principal rafters and tie members, RHS 50 × 50 × 2.6 mm for intermediate members and bracings and RHS 40 × 40 × 2.6 mm purlins placed at spacing not exceeding 750 mm centre to centre or as required by design. All members shall be accurately cut, aligned and welded using approved welding electrodes with continuous 6 mm fillet welds, properly ground and finished smooth.The work shall also include providing and fixing bird-proof enclosure to all side openings between the roof and parapet wall using 25 mm × 25 mm galvanized welded wire mesh fabricated from minimum 1.60 mm dia GI wiree welded to the truss. The roof shall be provided with a minimum slope of 1 in 12 towards the drainage side to facilitate quick disposal of rainwater. Necessary rainwater drip arrangement, flashings and closures shall be provided to prevent leakage.
62Providing and fixing 6 mm thick UV protected solid transparent polycarbonate sheets (clear/light blue/opal as approved), fixed over MS purlins with aluminium glazing bars, aluminium end profiles, EPDM rubber gaskets, self-drilling stainless steel screws with neoprene washers, aluminium flashing, side flashing, end flashing, ridge capping wherever required, weatherproof silicone sealant and all accessories recommended by the Engineer in Charge to make the roof completely watertight. (LMR)
63Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work.
64Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 18mm Granite of any colour or shade (Area of slab upto 0.5 sqm)
65Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply, including allCPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc: 15mm nominal outer dia pipes
6620mm nominal outer dia pipes.
67Providing and fixing chrome-plated (CP) brass diverter of approved make and suitable size, comprising heavy-duty forged brass body, suitable for connection to the existing water supply line, with ceramic cartridge/diverter mechanism, CP finish, threaded inlet/outlet connections, complete with wall flange, nipples, adapters, washers, PTFE tape, sealant and all necessary fittings and accessories. The diverter shall be securely fixed to the wall and connected to the existing water supply/fixture line, including cutting, chasing and making good the wall surface wherever required, testing for leakage and proper functioning, complete in all respects as per the manufacturer's recommendations and directions of the Engineer-in-Charge. The rate shall include all materials, labour, transportation, fixing accessories, tools and plants, dismantling of existing fitting wherever required and all incidental works necessary for satisfactory completion.Approved Makes: Jaquar, Hindware, Cera, Kohler, Grohe, Parryware or equivalent approved make.
68Providing and fixing 15 mm nominal bore C.P. brass bib cock ofapproved quality conforming to IS : 8931
69Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
70Providing and fixing 15 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms
71Providing and fixing 15 mm nominal bore C.P. stop cock (concealed) of standard design and of approved make conforming to IS : 8931
72Providing and fixing 15 mm nominal bore C.P. brass angle valve forbasin mixer and geyser points of approved make conforming to IS : 8931
73Providing and fixing un plasticized P.V.C. connection pipe with PTMT nuts, collars and bush of approved quality and colour ;15 mm nominal bore with 30 cm length.
7415 mm nominal bore with 45 cm length.
75Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
76Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: flexible pipe 32mm dia
77Providing and fixing white vitreous china flat back half stall urinal of size580x380x350mm with White P.V.C automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS:2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required:single half stall urinal with 5 liter P.V.C automatic flushing cistern.
78Providing and fixing wall-mounted granite shelf of approved colour and shade, 18 mm thick polished machine-cut granite slab of size approximately 600 mm × 500 mm (or as directed by the Engineer-in-Charge), having polished top surface, machine-polished exposed edges with rounded moulding, fixed over heavy-duty stainless steel/MS powder-coated concealed brackets anchored to the wall with suitable fasteners, complete in all respects.The item shall include dismantling and carefully removing the existing vitreous china wash basin with pedestal, including disconnecting all connected water supply and waste fittings, stacking the serviceable materials as directed by the Engineer-in-Charge and disposing of unserviceable material within the departmental premises.The item shall further include providing and fixing one medium-sized white vitreous china counter top wash basin conforming to IS 2556 (Part-IV), approximately 400–450 mm in length, mounted over the granite shelf with approved sealant, complete with 32 mm CP brass waste coupling, 32 mm heavy-duty PVC waste pipe, bottle trap, all necessary connections and fittings.The item shall also include providing and fixing one chrome-plated brass single lever basin mixer tap with hot and cold water connections, complete with 450 mm long stainless steel braided flexible connection pipes, angle valves, CP flanges, a superior mirror and all accessories required for complete installation. (LMR)
79Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 liter/6 liter (adjustable to 4 liter/8 liters), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
80Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink without drain board. 610x510mm bowl depth 200mm
81Providing, laying, jointing, testing and commissioning of ISI marked PVC SWR (Soil, Waste and Rainwater) pipes and fittings of approved diameters conforming to IS 13592 (Type A & Type B), including all specials such as bends, elbows, tees, Y-junctions, door bends, reducers, couplers, offsets, access doors, cleanouts, inspection tees, vent cowls, sockets, unions, floor traps, Nahani traps, gratings, clamps, holder bats, rubber ring joints/solvent welded joints, solvent cement and all accessories complete.The work shall include laying of 110 mm dia PVC SWR pipes for soil and sewage disposal from water closets and 75 mm/50 mm dia PVC SWR pipes for waste water disposal from wash basins, urinals, floor traps and other sanitary fixtures, including fixing on walls with approved PVC/MS clamps at suitable spacing or laying in trenches with proper gradient wherever required, complete with all fittings and accessories. The item shall include cutting chases in walls and floors, making openings through walls, RCC slabs and masonry, embedding pipes, providing sleeves wherever necessary, excavation and refilling for underground pipe laying, connection of the complete piping system to the existing septic tank, constrcution of inspection chamber, manhole and drainage line, testing the entire system for leakage and proper flow, making good the damaged plaster, flooring and masonry after completion, cleaning the site and handing over the completed work in perfect working condition, complete in all respects as per PWD Specifications for Sanitary Installations and the directions of the Engineer-in-Charge. The rate shall include all labour, materials, transportation, loading, unloading, scaffolding, excavation, backfilling, clamps, supports, solvent cement, testing, commissioning, tools and plants and all incidental works necessary for satisfactory completion of the work. Approved Makes Supreme Industries, Finolex, Astral, Equivalent approved make. (LMR)
82Providing, shifting and raising of existing water supply GI/CPVC/PVC pipes laid over roof, including dismantling from existing supports, re-routing to suitable alignment to ensure free flow of rainwater, raising the pipes over suitably sized PCC/RCC concrete blocks/supports at required spacing, providing clamps, brackets, bends, sockets, tees, pipes and other necessary fittings, jointing materials, cutting, threading where required, connection to existing pipeline, testing for leakage and making good all disturbed portions, complete in all respects as directed by the Engineer-in-Charge
83Providing, supplying and fixing new premium quality roller blinds of approved colour, shade and texture, manufactured from 100% polyester blackout/sunscreen fabric of minimum 280 GSM, UV stabilized, dust resistant, anti-fungal, moisture resistant and fire-retardant, suitable for office use. The blinds shall provide smooth, noiseless operation and effective control of sunlight and glare. The blinds shall be mounted on heavy-duty powder-coated aluminium roller tube of suitable diameter complete with powder-coated aluminium top channel, bottom weighted aluminium rail, high-strength operating chain with child safety mechanism, side brackets, mounting clips, end caps, chain guide, stainless steel screws, rawl plugs and all accessories required for complete installation.The item shall include measurement at site, fabrication to the exact size of each window, transportation, fixing, alignment, adjustment, testing for smooth operation, cleaning and handing over complete in all respects. The work shall also include making good minor damages to the wall surface caused during dismantling and installation.The blinds shall have minimum 90–100% blackout (where required) or 5% openness sunscreen fabric as directed by the Engineer-in-Charge and shall be capable of easy cleaning with long service life.The rate shall include all labour, materials, hardware, transportation, loading, unloading, tools and plants, scaffolding wherever required and all incidental works necessary for satisfactory completion of the work.(LMR)
84Providing, fabricating and fixing modular base cabinet shutters for the Kitchen and pantry platform , comprising powder-coated aluminium frame fabricated from extruded aluminium sections of minimum 50 mm × 20 mm × 1.2 mm thick, conforming to IS 733 and IS 1285, mitre-cut and assembled with suitable corner cleats, connectors, stainless steel screws and accessories complete.The shutters shall be infilled with 4 mm thick Aluminium Composite Panels (ACP) consisting of 0.25 mm thick aluminium skin on both faces bonded to a non-toxic LDPE/mineral-filled core, having PVDF/polyester coating of approved colour, shade and texture, fixed to the aluminium frame with approved structural adhesive, mechanical fasteners and glazing beads wherever required. The ACP panels shall be waterproof, termite-proof, corrosion-resistant, UV-resistant and suitable for interior applications.The shutters shall be mounted on heavy-duty SS-304 soft-close concealed hinges (minimum three hinges per shutter or as required), complete with hydraulic soft-closing mechanism, adjustable hinge plates, magnetic catches, stainless steel screws and all necessary hardware. Each shutter shall be provided with SS-304 satin finish handles of approved design and size or concealed aluminium profile handles, complete with locking arrangement wherever required.The item shall include adjustable aluminium/WPC internal shelves, shelf supports, aluminium skirting, end panels, fillers, kick plate, corner units, cut-outs for plumbing and other services, alignment and adjustment of shutters, cleaning and all incidental works necessary for proper completion.The rate shall include all materials, fabrication, transportation, loading, unloading, labour, stainless steel hardware, adhesives, fasteners, tools and plants, wastage, testing, commissioning and handing over complete in all respects as per the approved drawings and the directions of the Engineer-in-Charge.(LMR)
85Providing, fabricating and fixing in position aluminium framed cupboard of approved design and dimensions, comprising powder-coated/anodized aluminium frame fabricated from extruded aluminium sections of minimum 50 mm × 25 mm × 1.5 mm thickness, conforming to relevant IS specifications, securely assembled with aluminium corner cleats, SS screws, brackets and necessary connectors. The cupboard shall be provided with sliding shutters framed in matching aluminium sections and infilled with 4 mm thick ACP sheet/12 mm thick pre-laminated HDHMR board, as approved by the Engineer-in-Charge, with smooth, scratch-resistant and moisture-resistant finish.The sliding shutters shall be mounted on heavy-duty aluminium/SS sliding tracks with suitable top and bottom channels, nylon/ball-bearing rollers, guide channels, stoppers and soft-closing arrangement wherever required, ensuring smooth, silent and effortless operation. The shutters shall be provided with suitable recessed/profile handles and central locking arrangement, complete with lock, keys, catches and all necessary hardware.The cupboard shall include internal adjustable shelves of minimum 18 mm thick pre-laminated HDHMR board/ACP panel, supported on heavy-duty shelf brackets at suitable spacing, including vertical partitions, top and bottom panels, back panel, side panels, end closures, skirting/kick plate and all necessary fittings. The shelves shall be designed to withstand normal office storage loads without sagging.All exposed aluminium surfaces shall have uniform anodized/powder-coated finish of approved colour and shade. The cupboard shall be termite-proof, moisture-resistant, corrosion-resistant and suitable for office/institutional use. Necessary cut-outs, fillers and adjustments shall be provided to suit the existing wall, floor, skirting and other services.The work shall include site measurement, fabrication, transportation, loading, unloading, fixing, levelling, alignment, adjustment of sliding shutters, drilling, anchoring to floor/wall/ceiling wherever required, making good minor damages, cleaning and handing over complete in all respects as directed by the Engineer-in-Charge. The rate shall include all aluminium sections, panels, tracks, rollers, handles, locks, shelves, fasteners, brackets, adhesives, hardware, labour, T&P, wastage and all incidental works necessary for satisfactory completion.(LMR)
86Providing, supplying, fabricating and fixing in position Roll of Honours Board made of minimum 8 mm thick rigid PVC foam sheet/PVC board, of approved size, colour, shade and design, suitable for indoor institutional/office use.The board shall be suitably designed for displaying the names, designations and period/tenure of service of officers/officials, with individual acrylic/PVC name plates of approved size and thickness, having the required particulars as supplied and approved by the Competent Authority. The names and particulars shall be laser engraved, UV digitally printed or vinyl-cut using durable and fade-resistant lettering, with uniform font, spacing and alignment. The complete artwork/layout shall be prepared by the agency and submitted to the Engineer-in-Charge for approval before fabrication.(LMR)
87Providing comprehensive servicing, preventive maintenance, testing and minor repair of the existing Diesel Generator (DG) Set, including inspection and servicing of diesel engine, alternator, control panel and associated accessories, complete in all respects. The work shall include checking and cleaning of the complete DG set, engine oil replacement, replacement of oil filter, diesel/fuel filter and air filter wherever required, checking and topping-up of coolant, checking of radiator and cooling system, cleaning of radiator fins, checking of fan belt, tensioner and hoses, checking of fuel lines, fuel pump and injectors, checking of battery, battery terminals and charging system, checking of starter motor, alternator output, AVR, control panel, meters, indications, protection devices, AMF/auto-start arrangement and all electrical connections. (LMR)
88Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with sludge or manure mixing the same with forked soil, watering and maintaining the lawn for 30 days or more till the grass forms a thick lawn free from weeds & fit for mowing & disposal of rubbish as directed, including supplying good earth if needed but excluding the cost of sludge or manure (the good earth shall be paid separately.)
89Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts
90Carriage of material by mechanical means including loading, unloading and staking at site:Sand and Aggregate for avg 20 kms distance
91Bricks for avg 20 Kms distance
92Providing, supplying, installing, testing and commissioning of a suitable professional grade Digital Video Recorder (DVR) for the existing CCTV surveillance system, compatible with the existing installed CCTV cameras, cabling and accessories, including all necessary hardware, software, storage, power supply, connectors and accessories required for complete integration and satisfactory operation of the existing CCTV system. The DVR shall be minimum 16-channel, H.265/H.265+ compression, capable of recording and displaying video from existing cameras at suitable resolution and frame rate, with HDMI/VGA video output for connection to the existing LED display/monitor, USB ports, RJ-45 Ethernet port, remote viewing facility through LAN/Internet, motion detection, event recording, playback, backup through USB/network, date/time stamping, multi-screen display and user password protection.The DVR shall be provided with minimum 4 TB surveillance-grade hard disk drive suitable for continuous 24×7 recording, having sufficient recording capacity for the connected cameras, complete with SATA interface and suitable cooling arrangement. The system shall support simultaneous live viewing, recording, playback and remote access, and shall be compatible with the existing camera system irrespective of whether the cameras are of suitable analogue HD/IP technology, subject to site compatibility. Necessary DVR power adaptor/SMPS, HDMI cable, SATA cable, network patch cord, BNC connectors/baluns or other interface accessories, USB mouse, remote control and all other accessories required for complete operation shall be included.The work shall include dismantling of the existing defective/obsolete recording unit, if any, installation and configuration of the new DVR, connection of all existing CCTV cameras, checking of existing camera cabling and connectors, programming of camera channels, date/time setting, recording configuration, motion/event settings, user permissions and connection to the existing LED display through HDMI/VGA output. The DVR shall be configured to display all available cameras on the existing LED screen in suitable multi-view format and shall provide full-screen viewing of individual cameras. The item shall further include connection of the DVR to the existing LAN/network/internet facility, wherever available, for remote monitoring through authorised computer/mobile application, including necessary software/application configuration. Necessary minor replacement of connectors, patch cords, BNC connectors, power connectors and other small accessories required for satisfactory integration shall be included in the rate. Existing cameras and major lengths of existing CCTV cable shall be retained and reused.The complete system shall be tested for live viewing, recording, playback, storage, camera switching, date/time stamping, USB backup, HDMI display and remote access, and shall be handed over in satisfactory working condition. The rate shall include all materials, labour, transportation, installation, configuration, testing, commissioning, programming, minor accessories, tools and plants and all incidental works necessary for complete execution as directed by the Engineer-in-Charge.The DVR and hard disk shall be suitable for continuous 24×7 surveillance operation and shall be supplied with a minimum 3-year manufacturer's warranty.Approved Makes: Hikvision, Dahua, CP PLUS, Bosch, Honeywell, Panasonic, Prama or equivalent approved make.
93Providing and fixing modular front plate/cover plate of including replacement of damaged mounting frame and all accessories complete. Legrand, Schneider Electric, Havells, Anchor by Panasonic, Crabtree, L&T, GM Modular or equivalent approved make:4 Module
948Module
9512Module
9616Module
97Providing and fixing modular switches of approved make complete. Legrand, Schneider Electric, Havells, Anchor by Panasonic, Crabtree, L&T, GM Modular or equivalent approved make.:10amp
9820amp
99Providing and fixing modular sockets of approved make complete.Legrand, Schneider Electric, Havells, Anchor by Panasonic, Crabtree, L&T, GM Modular or equivalent approved make:10amp
10020amp
101Providing and fixing LED Panel Light 2' × 2' (36–40 W) recessed type complete with driver and all accessories.Philips, Wipro, Crompton, Havells, Bajaj, Syska or equivalent approved make.
102Providing and fixing 20 W LED Tube Light complete. Philips, Wipro, Crompton, Havells, Bajaj, Syska or equivalent approved make.
103Providing and fixing 12W 4'' panel/cob fitting complete. Philips, Wipro, Crompton, Havells, Bajaj, Syska or equivalent approved make.
104Providing and fixing 250 A, 4 Pole MCCB, 36 kA breaking capacity, adjustable thermal-magnetic release, complete. Schneider Electric, Siemens, ABB, L&T, Legrand, Havells or equivalent approved make.
105Providing and fixing 100 A, 4 Pole MCCB, complete.Schneider Electric, Siemens, ABB, L&T, Legrand, Havells or equivalent approved make.
106Providing and fixing 63 A TPN DB, 4 Way, double door, with busbar, neutral link, earth bar etc. Schneider Electric, Siemens, ABB, L&T, Legrand, Havells or equivalent approved make.
107Replacement of capacitor in ceiling fans including testing.
108Repairing/overhauling ceiling fan including complete internal rewinding, replacement of bearings, capacitor, leads, insulation, testing etc.
109Supply, installation, testing & commissioning of Online/Line Interactive Inverter (5 kVA) with Tubular Batteries 200Ah, battery rack, interconnections and commissioning complete. (One set per floor) Luminous, Microtek, V-Guard, Exide, Livguard or equivalent approved make.
110Providing, supplying, installation, testing and commissioning (SITC) of heavy-duty exhaust fan of minimum 300 mm sweep (12 inch), suitable for continuous operation in office buildings, having high-efficiency copper wound motor, dynamically balanced aluminium/metallic blades, low noise operation, ball bearing construction, bird guard, safety grill on both sides, powder-coated metal body/frame, complete with all mounting accessories.The item shall include cutting or enlarging the existing wall opening wherever required, providing and fixing suitable MS/PVC frame, making good the disturbed masonry/plaster, fixing of exhaust fan with suitable anchor fasteners, connecting with the existing electrical wiring through 1.5 sq.mm FRLS copper conductor, modular switch, indicator, PVC conduit/casing-capping wherever required, testing, commissioning and handing over complete in all respects as directed by the Engineer-in-Charge.The rate shall include all labour, materials, transportation, lifting, scaffolding, T&P, wiring up to 3.0 metres, necessary fittings, fixing accessories, making good the damaged finishes after installation and all incidental works required for satisfactory completion of the work.The exhaust fan shall conform to relevant IS specifications, be suitable for operation on 230 V, 50 Hz AC supply, and shall be supplied with a minimum 2-year manufacturer's warranty. Approved Makes Crompton Greaves, Havells, Orient Electric, Bajaj Electricals, Usha, Anchor by Panasonic, Equivalent approved make.
111Providing, supplying, installation, testing and commissioning (SITC) of an Integrated Solar LED Street Lighting System on the existing pole and mounting bracket available at site 40 W Integrated Solar LED Street Light with 100 Wp Solar Panel, LiFePO₄ Battery and all accessories. The integrated solar street lighting system shall conform to the latest MNRE specifications and relevant IEC/BIS standards and shall be supplied with a minimum 5-year comprehensive onsite warranty covering the LED luminaire, solar PV module, charge controller and battery. The item shall also include minor modifications to the existing mounting arrangement, tightening/replacement of clamps, waterproof cable routing, making good all disturbed portions and all labour, transportation, lifting, tools and plants, consumables and incidental works required for successful completion of the work. Approved Makes: Philips/Signify, Bajaj, Havells, Crompton, Tata Power Solar, Waaree, Vikram Solar, Wipro or equivalent approved make, conforming to applicable BIS/MNRE/IEC requirements.
112Providing and fixing new digitally printed premium quality flex media on the existing rooftop display board of size 6.00 m × 1.00 m, after carefully dismantling and removing the existing damaged/faded flex, including cleaning of the existing MS frame, tightening of existing supports wherever required and disposal of unserviceable material as directed by the Engineer-in-Charge.The new display shall be printed on high-quality front-lit star flex of minimum 440 GSM thickness, UV and weather-resistant, digitally printed using solvent/eco-solvent inks with high-resolution printing (minimum 720 dpi), incorporating the name of the building, departmental logo/emblem, colour scheme, typography and other contents as approved by the Competent Authority. The flex shall be hemmed on all sides, reinforced with suitable webbing and provided with rust-proof aluminium/brass eyelets at suitable spacing.The flex shall be securely fixed over the existing MS frame using UV-stabilized nylon rope, PVC-coated GI wire, SS cable ties or suitable fastening arrangement, ensuring wrinkle-free, taut and uniform appearance. The item shall include all necessary cutting, stitching, eyelets, fixing accessories, ladders, scaffolding, transportation, loading, unloading, installation, testing of proper fixing, cleaning of the display surface and all labour, materials, tools and plants, consumables and incidental works required for complete execution of the work.The completed signage shall be weatherproof, fade-resistant, waterproof and capable of withstanding normal wind loads. The rate shall include preparation of artwork, layout design, modifications as directed by the department prior to final printing and handing over the completed work in all respects.
113Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group-A
114Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loopearthing as required.
115Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.:2 x 1.5 Sq.mm + 1 x 1.5 Sq.mm earth wire
1162 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1172 X 6 sq. mm + 1 X 6 sq. mm earth wire
1184 X 6 sq. mm + 2 X 6 sq. mm earth wire
1194 x 10 sq. mm + 2 x 6 sq. mm earth wire
120Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.1 x 1.5 sq. mm
121Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
122Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch
1233 pin 5/6 A socket outlet
12415/16 A switch
1256 pin 15/16 A socket outlet
126bell push
127Ding dong bell
128Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
129Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
130Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
131Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\"curve including connections, painting etc. as required.
132Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mm x 75mm)
1334 Module (125mm x 75mm)
1346 Module (200mm x 75mm)
1358 Module (125mm x125mm)
136Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:6 way (Double door) (SPN type)
137Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:6 way ( 4+18), (Double door) (TPN type)
138Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISImarked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947- 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. ,conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.:Single pole 6/10/16/32 Amp
139Single pole and neutral 32 Amp
140Single pole and neutral 40 Amp
141Triple pole and neutral 40 Amp
142Triple pole and neutral 63 Amp
143Supplying & fixing of LED Batten Tube fitting 600mm size 10/11 watt Aluminium housing with 1000 Lumens and min lumens efficiency 100 lumens/watt P.F >.90
144Water tight bulk head LED fitting with 10 watt LED lamp.
145Supplying, Installation, Testing & Commissioning of 18 WATT LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
146Supplying, Installation, Testing & Commissioning of 18- 22 Watt LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
147Supplying, Installation, Testing & Commissioning of 36 watt Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz,Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained tilllife ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(StandardDeviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)
148Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
149Supplying and fixing of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply. including connections etc. as required. BLDC Ceiling fan 1200 mm sweep alongwith rod upto 1'-6\\" long (3 Star)
150Exhaust fan 300 mm size (Metalic)
151Supplying, installation, Testing & Commissioning of 72 watt Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%,Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5,n Driver efficiency >85%,THD < 10% as per IEC61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As perANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
152Supply, installation, testing & commissioning of maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly The earthing pit should be covered with PVC cover.
153Providing and fixing of 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required.
154Providing and fixing 4.00 mm dia copper wire on surface or inrecess for loop earthing as required.
155Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 3 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water . The earthing pit should be covered with PVC cover.
156Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
157Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
158Supplying, Installation, Testing & Commissioning of inverter 2000 VA along-with 2 Nos. long tubular batteries 150 AH and trolly of suitable size.
159SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge.
160Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type) :160 Amp, 36 KA, FP MCCB ICU = 100% ICS
161100 Amp, 25 KA, FP MCCB ICU = 100% ICS
16263 Amp, 25 KA, FP MCCB ICU = 100% ICS
163ON Load Change Over Switch FP 100 amp. (Front operated)
164Aluminium Bus Bar 400 Amp set of 4 strips
165Aluminium Bus Bar 200 Amp set of 4 strips 18\\"
166Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc.
167Supplying & laying of PVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) :35 sq. mm 3.5 core
16895 sq. mm 3.5 core
169Supplying of LED TV (Smart TV) UHD 4K 43\\"
170Supplying, installation, testing and commissioning of 1.5 Ton Inverter type Split AC's (copper) Cold type of minimum capacity following Specification as detailed below. 1. Should be of inverter type2. Cooling capacity (in Tr): 1.53. BEE Star rating: 34. Maximum local temperature: 52 C5. Rated cooling capacity (BTU/hr.): 19000 or above6. Condensing coil: 100% Copper with grooved copper tubes7. Electrical input, 220 V ± 30/50Hz/Single Phase8. Noise level (indoor unit): = close to 35 dB9. Compressor type: rotary or any other suitable technology10. Refrigerant type: R-3211. Anti-Corrosive Coating for the outdoor unit: Bule Fin/Gold Fin or equivalent12. Compressor Warranty: 10 years13. PCB Warranty: 5 year14. Total System Warranty: 1 year15. Minimum noise level of the indoor unit should be around 28 dB (A)16. Should have air filtering mechanism for removing dust17. Supplier has to include brochure of the quoted modelEach unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. The job includes Repairs made to wall whereever as required.
171Supplying, Installation, Testing & Commissioning of following capacity automatic voltage stabilzer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary. Warrantee.:- 4KVA 2 Years from the date of installation.
172Supplying & fixing of M.S Wall/Floor Stand duly powder coated for outdoor unit of Split AC
173Supplying & fixing of drain pipe for indoor unit 1\\"
174Extra length of copper pipe for outdoor unit and suitable size copper cable of required size for 1.5 Ton AC
175Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge. Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 1meter
176Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.
177Supply Installation Testing and Commissioning of 6U Front Glass Door Single Section Wall Mount Cabinet Loaded with all Accessories like PDU , Cable Manager, Mounting Kit.Make- Duranet, Netrack, Dlink, APW, Rittal
178Supply, Installation, Testing and comissioning of 06 port Layer ‑2 unmanagable Switch with Power on Ethernet (PoE) enabled, with 04 nos. 10/100/1000base Tx PoE port with 2 SFP port, 1 no. dual personality Gbe Port for copper/fiber uplink, 20 Gbps switching capacity, 14.88 MPPS Forwarding performance , maximum power consumption 64 watt. Make: Cisco/D-link
179Supplying, drawing, Installation, Testing and commissioning of Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with OperatingTemperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force: 11.5Kg etc. complete as required. 1 Run of cable
180Supplying Installation Testing and Commissioning of 2 MP IP IR Dome/Bullet Camera having following specifications, type of lens and features etc :-1) Signal System: PAL/NTSC, Signal to Noise Ratio: >50 dB, Camera should display Camera title, Date & Time in live & recorded video2)Image Sensor: 1/2.8\\" or better progressive Scan CMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.3) Compression (Minimum):-Video:- H.265 or better, H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726,AAC, G.7234) Wide Dynamic Range:- WDR (120db or more)5) Digital Noise Reduction:- DNR (3D) On/Off6) Video Streaming & Frame Rates :- Triple streaming , configurable (Main stream: 2MP (1920 ×1080)@25/30 fps,Sub streams minimum: 720P@25/30 fps). 7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion,Motion Detection 8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, syslog, video encryption, IP/MAC filtering, HTTPS, trusted upgrade, trusted boot.9) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memoryn Card.10) Recording Management: Format SD, overwrite, storage management, video to NAS device11) Alarm Trigger : Motion/tampering detection; audio detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS,unicast 13) System Capability: ONVIF, Camera shall support open source VMS 14) Ethernet: 1 RJ 45 10/100 Ethernet port 15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement. 16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source. 17) Power Requirement: 12VDC/24 VAC/PoE (802.3af)/ePoE 18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body19) Operating Condition:- Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing) 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or better 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS
181Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below : 1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses for number of channels of NVR to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP, IR camera or more and must be ONVIF with minimum support of 256Mbps incoming Bandwidth. 2) NVR should support H.265 or better, H.264, MJPEG, MPEG4 support 3) Must support 1 channel Input, 1 channel Output, RCA for Two-way Talk 4) Intelligent auto power on when power resumes after power outage. 5) Storage: It should support minimum 2 SATA Slots with 20TB capacity/ Slot. 6) Connectivity Interface : 1 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232 7) Backup Interface : Its should have 2 Nosx USB port (1x USB3.0, 1xUSB2.0) 8) Video Output Ports: 1x HDMI and 1 VGA 9) Alarm Ports: It should have 4/1 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc. 10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring, network disconnection and panic 11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing. 12) Protocols: HTTP, HTTPS, TCP/IP, IPv4, UDP, NTP, DHCP, DNS, SMTP, UPnP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need. 13) Standards: CE, FCC, RoHS and BIS Certified 14) Power Supply : Should support 12VDC, 4Amp or AC100-240V, 50/60Hz Power supply. 15) Operating Condition : Ambient Temperature (-5°C to 50°C), humidity 90% (max) (non-condensing) 16) The VMS, NVR application shall support all the features & functionalities of the offered cameras. 17) VMS should consist of Base license and Channel Licenses. VMS should be provided with camera Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality. 18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage.19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet. 20) Must support Resolution: 7680x4320 (8K), 3840*2160, 1920×1080, 1280×1024,1280×720, 1024×768 21) Must support recording resolution upto 32MP 22) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode 23) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page24) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm 25) It should support Network Support: HTTP, TCP/IP, SMTP, DHCP, DNS, DDNS, FTP, NTP, UPnP, Multi IP Setting. Convert multiple recording files to one avi/MP4 file. 26) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection. 27) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan 28) Alarm Notification should be linked with Recording,snapshots, Camera external alarm output, buzzer, logs, presets and email. 29) Built-In Artificial Intelligence: NVR should have built-in AI :- - 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection 30) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detectionspeed of 12 face images/sec. 31) Face & Human Attributes Search: Search Pictures/Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella. 32) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes. 33) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception 34) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email. 35) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection,Violence Detection. 36) Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency37) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics 8 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16
182Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. 6TB (Terabytes)
183Supplying and Laying of 20 Mtr HDMI
184SITC of MCB tupe Single Phase Surge Protection Devices 40 KA
185Supplying and Fixing of S.D Card 256 G.B in the Existing Camera
186Supply, Installation, Testing and comissioning of 8 port Layer ‑2 managable Switch with Power on Ethernet (PoE) enabled, with 8 nos. 10/100/1000base Tx PoE port with 2 SFP port, 1 no. dual personality Gbe Port for copper/fiber uplink, 20 Gbps switching capacity, 14.88 MPPS Forwarding performance , maximum power consumption 64 watt.
187Supply, intastallation, testing & commissioning of 25 KVA Capacity radiator cooled DG Set with suitable capacity engine directly coupled with alternator for 230 volt, single phase, 50 Hz, 2 wire, generation system complete with accessories, fuel oil tank & control panel etc as required and sound proof acquastic enclosure for the DG SET, including supply, fixing of antivibration pads suitable for 25 KVA DG Set as per standards of Engine manufacture, provision of conrol cable from engine to control panel to engine. Provision of pipe fuel pipe line of suitable size fron fuel tank to engine and over flow pipe engine to fuel tank complete gate valve and fitting leader maker etc. Supply , Intallation of starting batteries of suitable AH as recommended by manufacterer Heavy duty complete as required at site complete with stand and battery charger residentials sylencer sutaible for diesel engine exhaust pipe line complete complete flange, bend, flexible pipe all as required and as directed by engineer incharge including AMF Panel. DIESEL ENGINE (CPCB-4 NORMS COMPLANT) 4 Stroke, Radiaotr Coolled, Diesel Engine Model Having Following Arrangement :-Flywheel with Starter Ring for Generating Set Air Filter , Lube Oil Cooler Assembly with accessories.Exhaust air manifold ALTERNATOR Rated at 25 KVA, 230 Volts, single Phase, 2 Wire, 0.8 P.F (lag), 50HZ, 1500 RPM, IN Accordance with IS 4722 as per following Specification Rating: Suitable for an over-load of 10% for 1 hour in every 12 hours operation. Voltage Regulation: Provided with fast response thyristor type electronic automatic voltage regulator, which holds output voltage within desired limits . (+/- 1%). Excitation: Self excited-self regulated. Alternator Loading: Suitable for taking rated load immediately after machine reaches rated voltage and speed. Vibration: Suitable for direct coupling with Engine and mounted on common M.S. Channel base frame. Enclosure: Screen protected drip proof enclosure with IP – 23 degree of protection. Cooling: Air Cooled type with radial fan mounted on Rotor.Winding and Insulation: Insulation class H as defined in IS – 4722.Exhaust Bellow ,Fuel Fiter,Lube Oil Filter,Exhaust Gas Turbocharger with after Coller,Day tank for fuel with markings,ECP Panel mounted on a separate frame.Radiator with Pusher Type Fan, With Fan Guard, Coolant Pump,12V Electrical Starting System with Starter Motor and Battery Charging AlternatorEngine Mounting Supports ACCESSORIES :- MS Base Frame Suitable for Mounting of the Offered Engine and Alternator. Day Fuel Tank of Standard Capacity Complete Fuel Gauge, Inlet/Outlet Connections, Drains Plug, Etc .2 Nos 12 Volts DC Battery of SUITABLE Capacity with Leads .1 Set of AVM Pads Fitted in Base Frame. PCC Platform of required size for D.G set
188Design, manufacture and supply of outdoor type of three phase 415 volt LT unbalanced 40 KVA servo controlled automatic voltage stabilizer copper wound oil cooled type designed for input voltage 160 V to 450 V phase to phase and output voltage 415 V ± 1% phase to phase and 230 volt ± 1% phase to neutral and frequency 50 HZ +/- 3%. The no load current shall not be more than 5% of the rated output current. The stabilizer shall be totally powder coated from outside to have aesthetic outlook and inside of tank should be zinc chromate painted. Panel should be screen-printed. The unit shall be housed in sheet steel of 14 gauge thickness having wheels with sturdy construction to withstand the rigorous shifting movement, repair works and handling. The unit shall be supplied with first filling of fresh filtered transformer oil having dielectric strength and shall be suitable for unbalanced input voltage and unbalanced output load . PROTECTIONS - Under voltage , over voltage , short circuit, overload and surge protection through suitable capacity MCCB BYPASS ARRANGEMENT - Bypass arrangement shall be provided through suitable capacity bypass switch and complete with cement concrete platform of required size as per instruction of Engineer in-charge and RiTES/CEIL (Tested) Certificate in this respect to be submitted. The job includes CAMC for 2 Years after DLP of 1 Year.
189Supplying, installation, testing and commissioning of 1 KVA offline UPS with minimum backup of 20 minutes and having over load, short circuit protection. Approved Makes: APC, Numeric, Vertiv, Eaton, Delta, Microtek, Luminous or equivalent approved make.
190Supplying, fixing & commissioning of vertical Storage Water Heater (Geyser) of following capacity along with PVC Pipes etc as required. (5 Star with 8 Bar Pressure) Approved Makes: Bajaj, Racold, Havells, AO Smith, Crompton, V-Guard, Venus, Orient Electric, Usha, Hindware or equivalent approved make conforming to applicable BIS standards: 5/6 Ltr
19125 Ltr
192Supply of following electrical Heater:Radiator type Oil Heater 9 Fins
193SITC of Water purifier for RO+UV+UF+TDS Control with capability to remove bacteria, viruses, chemicals, and even dissolved impurities such as Arsenic, Rust, Pesticides & Fluorides to make water 100% pure and healthy that meets drinking water standards of IS:10500. It should have atleast two RO membranes and a high-pressure pump for purification that facilitates a max flow rate of 50L/hr.It should be provided with a separate storage tank of 7L capacity which ensures a steady supply of purified water even in the absence of electricity or running tap water. KENT, Aquaguard/Eureka Forbes, Blue Star, AO Smith, Havells, Livpure, Faber, Pureit, Panasonic, Voltas Beko or equivalent approved make conforming to relevant BIS standards.
194Providing, supplying, installation and commissioning of 86-inch 4K UHD LED Smart Display with wall mounting bracket, HDMI cable, wireless screen sharing, inbuilt Android/Smart OS, complete with 4K USB/Web Camera (minimum 4K resolution with microphone array) suitable for video conferencing including 2 nos bluetooth microphones and 6 nos speekers. Approved Makes: Samsung, LG, Sony, BenQ, ViewSonic or equivalent approved make.
195Providing and fixing of ISI Marked CO2 gas type portable fire extinguisher of following capacity and fire rating, confirming to IS:15683 & PESO approved M.S. cylindrical body made from seamless pipe confirming to IS 7285 finished externally with red enamel paint, control discharge mechanism fitted with 1 meter long wire braided hose & Flat Horn with diffuser nozzle, suspension bracket conforming fixed to wall with brackets complete with internal charge complete with all accessories etc. complete as required. Capacity 4.5 Kg, 55B
196Providing and fixing of ISI Marked ABC portable Powder type fire extinguishers of following capacity and fire rating,confirming to IS:15683 & filled with Mono Ammonium Phosphate Powder 90% confirming to IS 4308, consisting of welded M.S. cylindrical body internal & external polyester powder coating, squeeze lever discharge valve fitted with pressure indicating guage, EPDM rubber hose 30 cms long with both ends aluminium crimped,complete with suspension hookes and accessories etc. complete as required. Capacity 4.0 Kg, 4A 144B
197Supply, installation, testing, and commissioning of Straight Line Kitchen Chimney with Push Button, Baffle filters 60cm 1000 m3/h capacity , suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete withaluminum duct pipe, cowl cover, 2 clamps, aluminum tape & other accessories, directly on the wall, including connections, earthing, making good any damages etc. as required. Faber, Elica, Hindware, and Glen. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58526237
AUTHORITY Government Departments
TENDER VALUE 1.64 Crore
LAST DATE 21-11-2026
Authority
Authority Name Irrigation And Flood Control Department
Work Description Tender for Upgradation And Renovation Of Various Infrastructure At Jkwrra Building Complex Satwari.
Basic Detail
Tender No e-NIT No. 08 of 2026-27
Bidding Type Tender
Location
City Jammu
State Jammu and Kashmir
Key Dates
Publish Date 14 Nov 2026
Submission Date 21 Nov 2026
Open Date 23 Nov 2026
Finance
Tender Value 1.64 Crore
Tender Fee 2000
EMD 3.28 Lakhs
Exemption Not Available
Document List
3917da22-6c3a-4cff-9820-28043c0b3917.html
BOQ_1123939.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

3917da22-6c3a-4cff-9820-28043c0b3917.html

xls

BOQ_1123939.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender