Tender For Renovation And Provision Of Additional Facilities At Namakkal Uzhavar Sandhai In Namakkal District For The Year 2026-27
Tender Value
13.86 Lakhs
Estimated cost
Bid Submission
23 Nov 2026
6 days left
EMD
17000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Namakkal → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation And Provision Of Additional Facilities At Namakkal Uzhavar Sandhai In Namakkal District For The Year 2026-27
BOQ
| Sl. No. | Item Description |
| 1 | Earth work excavation for foundation by Mechanical means for Isolated & Combined Footing etc in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers.- Upto 2.40m Footing Depth. Data worked out for 48 m3 per day/8 hrs. |
| 2 | Supplying and filling in foundation, basement, etc with filling Crushed Stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 3 | Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers - Mixing by mechanical means |
| 4 | Brick work in following Cement Mortar using best quality Fly ash Brick of size 230x110x70mm with class designation of 10 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge. In Cement Mortar 1:5 |
| 5 | Foundation and Basement |
| 6 | Cement Concrete 1:2:4 (One Cement, Two crushed stone sand and Four hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges, centering and shuttering but including Super Plasticiser, mixing charges for machine mix, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three Sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers - machine mix |
| 7 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) |
| 8 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 9 | Providing Groove cutting in flooring concrete for 10mm width and 20mm depth and filling the groove with combination of Anabond Tuffseald 2G and bitumen tar including cost of all materials and labours etc complete. |
| 10 | Vacuum dewatering on freshly laid and thoroughly vibrated concrete surface to produce a homogeneous and smooth concrete surface .Suction matshall be spread over the leveled fresh concrete surface and shall be connected by the suction hose to the vaccum pump for dewatering of surplus water in the concrete . After dewatering is complete , the concrete surface is trawled with minimum two passes to achieve a wear resistance concrete surface |
| 11 | Supplying and fixing 5HP 3 phase Submersible Monoblock Motor with ISI mark including cost of conveyance and labour fixing charges etc., complete and as directed by the departmental officers . |
| 12 | Supplyng and Fixing Of 4 core 4Sqmm 1.1KV Grade aluminium conducter cross linked poly Ethylene PVC Sheathed cables etc.,complete |
| 13 | Supplying and fixing UPVC Column pipe of best quality using submersible pump in borewell class 5 1MPa or 10 Kg/cm2 Pressure 40 mm dia |
| 14 | Supplying, laying and jointing G.I. Pipes of approved quality and best variety of \\"B\\" class pipe of the following dia including labour fixing G.I. Specials, (excluding charges for cutting and threading of pipes, cost of such specials) to wall with necessary teak wood plugs, clamps, screws, thread balls, shellac, etc., making holes on the walls (or) drilling holes in roof and making good the dismantled portions to original condition with necessray brick work / concrete and plastering wherever necessry with necessary scaffolding charges. The pipes are to be painted with the 2 coats of good variety and approved best quality of synthetic enamel paint over a priming coat of red oxide etc., complete in all floors complying with standard specification. G.I. pipes shall be got approved by the Executive Engineer before use on works - Internal water supply - above Ground Level / External water supply - above Ground Level |
| 15 | Supplying and fixing of 3 Phase Panel Board including labour charges etc., complete as directed by the departmental officers. |
| 16 | Supplying and fixing Mild Steel grills for windows, ventilators etc.,complete complying with standard specifications and as directed by the departmental officers. |
| 17 | Manufacturig, supplying and installation of 70mm x 70mm MS square tube post with base plate including cost of erection and welding, finishing with two coats of synthetic enamel paint over a primer coat including cost of transportation, loading and unloading erection and dismantling if any needed and redoing the same to original condition etc., complete. |
| 18 | Supplying, fixing and roofing with colour galvalume sheet of 0.47mm thick with all necessary accessories such as J/V bolt and nuts of suitable length with suitable bitumen washers complete complying with standard specification and as directed by the departmental officers. |
| 19 | Brick partition walls of 11.50cm thickness using best quality Burnt Clay Brick of size 9\\" x 4 1/2\\" x 3\\" with class designation of 7.5 conforming to IS 1077-1992 in Cement Mortar 1:3 (One Cement and Three CS Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer, curing etc. complete complying with standard specification and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) |
| 20 | Solid PVC door shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter. |
| 21 | Manufacturing supplying and fixing of Fully Panelled steel door with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames, stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter. 3nos. of Steel Parliament Hinges of Size 125mm x 150mm in case of single leaf and 6nos. of Steel Parliament Hinges of Size 125mm x 150mm in double leaves shutter to be provided. 6nos. of holdfasts 200 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. |
| 22 | Supplying, fixing of cylindrical vertical notational polythene water storage tank of 1000 litres capacity confirming to I S. 12701 / 96. the tank is meant for outer (or) indoor, use complete with removable hinged top locking arrangements and to make provision to fix with simply pipe lines necessary manhole with cover and including all PVC specials, plugs, screws, nails to fix the tank etc., and the tank should be fixed firmly as directed. The rate shall inclusive of all materials labour, conveyance, hoistings and fixing charges etc., (The water tank should be got approved by the Executive Engineer before use on works by the dept., Officers. |
| 23 | Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.. |
| 24 | Finishing the top of roof with one course of machine pressed tiles of following size of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers.( Pressed Tiles of 230mm x 230mm x 16 mm to 18mm) |
| 25 | Supplying, fabricating, erecting and fixing Hilux (or) Equivalent Board False Ceiling upto a ceiling height of 4.5m from floor level. Using perforated sheets (10mm thick) |
| 26 | Painting two coats of newly plastered wall surface with ready mixed plastic Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the departmental officers. |
| 27 | Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with “P” or “S” trap conforming to BIS with crushed stone sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works). |
| 28 | Flooring with ceramic tiles of following size and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 29 | Dadooing walls with following best approved quality, white / colour glazed tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) printed design colour glazed tiles of size 300 x 450 x 8mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysNov 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents