Rural Development Local Bodies Closing in 5 days TDR #58524044

Tender For Annual Plan-Project 374/26 Motor Installation For Different Water Scheme Under Kodiyathur Panchayath-Motor Installation-General Electrical Work

Issued by Local Bodies · Kozhikode, Kerala
Tender Value
3.72 Lakhs
Estimated cost
Bid Submission
21 Nov 2026
5 days left
EMD
9324
Bank guarantee accepted
Document Fee
825
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kozhikode → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Annual Plan-Project 374/26 Motor Installation For Different Water Scheme Under Kodiyathur Panchayath-Motor Installation-General Electrical Work

BOQ

Name of Work:- Annual Plan-Project 374/26 Motor Installation for Different Water Scheme under Kodiyathur Panchayath-Motor Installation-General Electrical Work
Sl. No. Item Description
1Electrical
2OD523963/2025-2026:Supply and fixing 50mm NRV(GM)-Zoloto
3OD523964/2025-2026:Supply and fixing 50mm Ball valve(GM)-Zoloto
4OD523966/2025-2026:Supply, treading, laying and joining of 75/80mm size 80sedulous ASTM pipe approved make with required specials as delivery pipe using required leak proofing materials etc as required
5OD523967/2025-2026:Supply and fixing suitable pressure gauge in the delivery side of the pump
6OD523968/2025-2026:Preparing and submitting the relevant documents in KSEB office including sketches and necessary drawings, filling the required proforma for service connection application, collecting the various documents and after obtaining the signature from the applicant. Remitting the application fee and the required amount . The required amount may be collected from Panchayath/Municipal office and hand over the receipt received from KSEB to the authorities.
7OD523969/2025-2026:Supply and fixing of suitable MS Hook on outer wall of the building for tying the Gi wire used for supporting the wp wire from KSEB pole
8OD523970/2025-2026:Supply installation testing and fixing of 100 Amps TP&N SFU on wall using bolt &nuts and PVC/Rubber bushes
9OD523972/2025-2026:Supply installation testing and fixing of 63 Amps TP&N SFU on wall using bolt &nuts and PVC/Rubber bushes
10OD523973/2025-2026:Supplying and fixing 50 mm dia medium class GI pipe for supporting the delivery pipe on the top of the well
11OD523975/2025-2026:Supply and laying of 75mm High pressure PVC pipe
12OD523976/2025-2026:Supply and laying of 50mm High pressure PVC pipe
13OD523977/2025-2026:Dismantling and removing the existing old damaged pump up to 20 HP including foundation bolts . Handing over the same to Municipal/ Panchayath authorities. Make good the surface including plastering and painting as required
14OD523978/2025-2026:Dismantling and removing the existing old and rusted Panel Board. Handing over the same to Municipal/ Panchayath authorities. Make good the wall including plastering and painting
15OD523979/2025-2026:Supply and fixing Red, Yellow, blue LED indicator, AC/DC as required.
16OD523980/2025-2026:Supplying and fixing flat iron clamps made of 40x6mm flat iron clamp of 40cm with suitable size bolt and nut for fixing delivery pipe on the top of the well as required
17OD523981/2025-2026:Supply and fixing 63A,HRC fuse with 63A fuse link with connections, in the existing meter board
18OD523982/2025-2026:Supplying and fixing 100A , 2 way neutral links mounted on DMC/SmMC base with connections, in the existing meter board
19OD523983/2025-2026:Supplying and fixing 63A , 2 way neutral links mounted on DMC/SmMC base with connections, in the existing meter board
20OD523984/2025-2026:Supply and fixing 100A,HRC fuse with 100A fuse link with connections, in the existing meter board
21OD523985/2025-2026:Supply and installation of dust and vermin proof , 3 phase Syntax Meter Board(GS-MB-6535) 650x350x250 size and to fix KSEB meters, fuse units CTs etc as required invludig fixing on wall,making good the damages Color painting etr... as required
22OD523986/2025-2026:Supply and fixing 10mm size stainless steel rope
23OD523987/2025-2026:Supply and fixing 12mm size nylon rope
24OD523988/2025-2026:Supply and providing 50mm ASTM flange set
25OD523989/2025-2026:Supply, treading,laying and joining of 50mm size 80sedulous ASTM pipe approved make with required specials as delivery pipe using required leak proofing materials etc as required
26OD523990/2025-2026:Providing and fixing 2 x 25 x 3mm GI strip test joint for earthing system
27OD523991/2025-2026:Supply and fixing single phase and dry run preventer
28OD523992/2025-2026:Supply and fixing Digital multi functional meter
29OD523993/2025-2026:Supplying and fixing 12W LED bub GM or equivalent make, Lumens greater than 1200Lm
301.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A
311.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
321.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
331.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
3490.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
3590.14.24.18:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.3 KVAr, 3 phase, 440 V, delta connected, standard duty Metalised Poly Propylene Capacitor, Box Type, suitable for direct connection to motors.
3690.14.24.21:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.6 KVAr, 3 phase, 440 V, delta connected, standard duty Metalised Poly Propylene Capacitor, Box Type, suitable for direct connection to motors.
3790.14.28.3:S & F Motor starters of the following ratingsThree phase DOL starters for 10HP motor
3890.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
3990.6.4.1:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 1 Run
4090.6.6.4:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.6 sq mm
4190.6.6.5:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.10 sq mm
4290.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
4390.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
441.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
452.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
462.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps
472.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
482.1.3:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 Amp TP&N
491.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
501.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
515.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
525.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
531.14.10:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire
541.14.9:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
55OD526166/2025-2026:Supply and fixing of 90mm to 50mm PVC reducer
56OD526170/2025-2026:Supply and fixing of 75mm to 50mm PVC reducer
57OD532959/2025-2026:Supply installation testing and commissioning of 20 HP vertical open well submersible pump set at rated voltage 3 phase 415V 50 Hz AC supply with a maximum head of 317m , discharge 300LPM at 208m head in the existing open well using suitable tools and plants. Kirloskar make 100HHF2020 model Kirliskar or equivalent make.
58OD532992/2025-2026:Supply installation testing and commissioning of 10 HP vertical open well submersible pump set at rated voltage 3 phase 415V 50 Hz AC supply with a maximum head of 182m , discharge 210LPM at 157m head in the existing open well using suitable tools and plants. Kirloskar make KU6iHHN210-1016 model Kirliskar or equivalent make.
59OD533025/2025-2026:Supply and installation of L&T make L&T ML1.5 FASD motor stsrter suitable for 20HP motor having relay range 13-21A Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58524044
AUTHORITY Local Bodies
TENDER VALUE 3.72 Lakhs
LAST DATE 21-11-2026
Authority
Authority Name Grama Panchayat
Work Description Tender for Annual Plan-Project 374/26 Motor Installation For Different Water Scheme Under Kodiyathur Panchayath-Motor Installation-General Electrical Work
Basic Detail
Tender No LSGD/CELSGD/56102/2026-2027
Bidding Type Tender
Location
City Kozhikode
State Kerala
Key Dates
Publish Date 13 Nov 2026
Submission Date 21 Nov 2026
Open Date 24 Nov 2026
Finance
Tender Value 3.72 Lakhs
Tender Fee 825
EMD 9324
Exemption Available
Document List
473fb6d8-c2d9-4cf4-af02-c89be5e656f2.html
BOQ_1518642.xls
SBDDWSS.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Nov 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

473fb6d8-c2d9-4cf4-af02-c89be5e656f2.html

xls

BOQ_1518642.xls

pdf

SBDDWSS.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender