Project Description
Tender For Addition/Alteration To Certain Otm Accn In Domestic Area At Bhisiana Under Ge (Af) Bhisiana
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of brick work or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles in any description and removing/disposal off from the site to outside MOD land complete all as specified and as directed. |
| 2 | Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge. |
| 3 | Material and labour for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. (inner girth only measured) complete all as specified and as directed. |
| 4 | Taking down cement plaster/rough cast plaster from brick walls/soffits of roof projections & chajjas /ceilings etc. including racking out joints, hacking for key & scrubbing down with water etc including disposal of rubbish material to any distance out side MOD land complete all as specified and as directed. |
| 5 | Material and labour for 15mm thick cement plastering/ rendering in cement mortar (1:4) on any face of Brick walls or concrete surfaces, finished even and fair complete all as specified and as directed. |
| 6 | Material and labour for rendering/plastering 10-12 mm thick in CM (1:6) on any face of Brick walls or concrete surfaces, finished even and fair complete all as specified and as directed. |
| 7 | Material and labour for rendering/plastering 5 mm thick in CM (1:3) on concrete surfaces of ceiling, finished fair and even complete all as specified and as directed. |
| 8 | Material and labour for rough cast plaster on exterior walls in two layers, under layer not less than 10mm cement plaster (1:3) (1 cement: 3 coarse sand ) furrowing the under layer with scratching tool, and while it is still in plastic state the roughcast mixture consisting of crushed stone or fine gravel aggregate (which is generally of size between 6 to 12 mm depending on the texture required) mixed with coarse sand and cement in the ratio of (1: 1: 1) shall be applied and finished even. The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure that larger aggregates are thoroughly covered, complete in all respects and as specified and directed by the Engineer-in-Charge. |
| 9 | Material and labour for preparation of old treated surfaces (plastered / unplastered) of ceiling by remove / scraping down all loose treatment etc with using broom, wire brush or by any other mean and after preparing the surfaces applying one coat of white wash by using paint brush complete all as specified and as directed. |
| 10 | Material and labour for preparation of old treated surfaces (plastered / unplastered) of walls/pillars /cornices by remove / scraping down all loose treatment etc with using broom, wire brush or by any other mean and after preparing the surfaces applying one coat of white wash by using paint brush complete all as specified and as directed. |
| 11 | Material and labour for preparation of new plastered surfaces of ceiling by brooming down or by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash by using paint brush complete all as specified and as directed. |
| 12 | Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down or by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash by using paint brush complete all as specified and as directed. |
| 13 | Material and labour for preparing the surface and applying two coats of Oil Bound Distemper (OBD) of approved make and shade to walls/pillars /cornices surfaces (over any type of surface new or old prepared after complete removal etc.) over one coat of cement primer suitable for OBD, paint and primer applying by using paint brush or roller brush complete all as specified and as directed. |
| 14 | Material and labour for complete removal of existing treatment of any type/description (any layer) from external/internal wall/ceiling surfaces, soffits/chajja/roof projection surfaces etc., by scraping steel patti and Mechanical sander/grinder machine having suction vaccum Bag (Smart periodical methodology), complete all as specified and as directed. |
| 15 | Material and labour for preparation of exterior surfaces of walls/ceiling/soffits etc (new surface or old prepared surface after complete removal where directed through site order book), applying traditional cement-based putty (white-cement-based polymer-modified powder) (thickness from 1 to 1.5 mm as required for desired smoothness and levelling of surfaces in two layers), including gently sand the surface with fine emery paper after filling the putty in first coat/second coat to make surface smooth and ready for receiving further painting work complete all as specified and as directed.Notes : (i) The prepared surface after putty, the contractor will inform to the Engineer-in-Charge/GE for site inspection before applying further finishes. Further finishes work will start only after approval of the prepared surface from the Engineer-in-Charge through site order. |
| 16 | Material and labour for preparation of interior surfaces of walls/ceiling/soffits etc (over any type of surface new or old prepared after complete removal etc), applying acrylic putty is a water-based, Smooth, creamy paste (ready-to-use), white or off-white color (thickness from 1.0 to 1.5 mm as required for desired smoothness and levelling of surfaces in two layers), including sanding with wall sander after filling the putty in first coat/second coat to make surface smooth and ready for receiving further painting work complete all as specified and as directed.Notes : (i) The prepared surface after putty, the contractor will inform to the Engineer-in-Charge/GE for site inspection before applying further finishes. Further finishes work will start only after approval of the prepared surface from the Engineer-in-Charge through site order. |
| 17 | Material and labour for preparing the surface and applying 02 coats of exterior acrylic emulsion paint of approved tint/shade (Company Depot Tinted) to external surface of walls /pillar, Soffits of Chajjas / Roof Projections / Cantilevers / Balcony etc. (over any type of surface new or old prepared after complete removal etc) over and including a coat of exterior alkali resistant water-based primer (primer shall be same make as acrylic emulsion paint), paint and primer applying by using paint roller/brush or airless spray gun complete all as specified and as directed.Brand and Make of exterior acrylic emulsion paint: - Apex Ultima of Asian / Weather Coat antidust of Berger / Weather shield Protect of Dulux / Excel Mica Marble of NerolacBrand and Make of primer for external : - Seal O Primer of Berger / Smart Care Primero of Asian / Excel Alkali Prime of Nerolac / Weather Shield Alkali Bloc of Dulux |
| 18 | Material and labour for preparation of new steel and iron surfaces of any description, not otherwise described, exceeding 10 cm in width or girth, including cleaning the surface free from dust, dirt, grease, oil and other foreign matter and surface imperfections by rubbing down with emery paper/sand paper or by other approved means to obtain a clean, smooth and even surface and further applying one coat of red oxide zinc chromate primer and two coats of first-quality synthetic enamel paint of approved brand, shade and tint, each coat applied by brush only after proper preparation and complete drying of the preceding coat, to produce a smooth, uniform, durable and aesthetically acceptable finish, complete in all respects as specified and directed by the Engineer-in-Charge. |
| 19 | Material and labour for mild steel TMT bars, grade Fe 500D/550D, any dia upt 12mm, cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.(NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.) |
| 20 | Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level of any description and in any position and including disposal of rubbish material to any distance out side MOD land complete all as specified and as directed. |
| 21 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided including removing debries/rubbish material from site to outside MOD land complete all as specified and as directed. |
| 22 | Material and labour for hard core of broken bricks of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified & directed by Engineer-in- charge. |
| 23 | Material and labour for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement including 10mm wide, 25/30mm deep joints at the rate not exceeding 3.00 mtr centre to centre and at every turning point, filling the Joints with bituminous sealing compound of grade ‘A’ complete all as specified and as directed |
| 24 | Material and labour for PCC (1:2:4), type B-0 using 12.5 mm graded stone aggregate as in coping, mud stops, packing sides/around of interlocking tiles, kerbs & similar work etc at ground and normal height including weatherings, slightly rounded or chamfered angles and including necessary form work as required etc. complete all as specified and as directed. |
| 25 | Material and labour for PCC (1:2:4), type B-1 using 20 mm graded stone aggregate as in surface channels, benching/coping of manholes/drains, coping, mud stops, packing sides/around of interlocking tiles, kerbs, bed block, cills, thrust block, for embedded posts & similar work etc at ground and normal height including weatherings, slightly rounded or chamfered angles and including necessary form work as required etc. complete all as specified and as directed. |
| 26 | Material and labour for 100mm thick cement concrete ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed. |
| 27 | Material and labour for 75mm thick cement concrete ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed. |
| 28 | Material and labour for providing and laying chequered cement concrete tiles of size exceeding 0.04 sqm but not exceeding 0.11 sqm, 25mm thick, manufactured by the table vibratory method using PU/rubber moulds, made from cement, graded aggregates, with grey cement and pigments, having approved pattern and texture, laid as in floors, footpaths, walkways and similar locations. The tiles shall be laid true to line, level and required slope, set and jointed in neat grey cement slurry at the rate of 3.00 kg per square metre, over the prepared bed/sub base (sub base bed measured and paid separately), filling joints with grey cement with pigment, complete in all respects, as specified and directed by the Engineer-in-Charge. |
| 29 | Supply and laying/fixing 80mm thick factory-made chamfered edge cement concrete paver block/ interlocking tile of M-40 grade, conforming to IS 15658:2021, grey cement with pigment, with approved design/size/ shape made by table vibratory method using PU mould, laid as in footpath, parks, lawns, drive ways or light traffic parking etc., over and including 30mm thick compacted bed of fine sand and filling the joints with sand, compacting through vibratory compaction by using plate vibrator, finishing and sweeping extra sand complete all as specified and as directed. |
| 30 | Supply and laying/fixing 80mm thick factory-made chamfered edge cement concrete paver block/ interlocking tile of M-40 grade, conforming to IS 15658:2021, pre-polished & pre-glazed, with approved colour/design/size/ shape made by table vibratory method using PU mould, laid in required colour & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., over and including 30mm thick compacted bed of fine sand and filling the joints with sand, compacting through vibratory compaction by using plate vibrator, finishing and sweeping extra sand complete all as specified and as directed. |
| 31 | Dismantling of floor hearth or wall tilling including cement mortar bedding but not backing including removing rubbish material from building/from the site to outside MOD land complete all as specified and as directed. |
| 32 | Material and labour for 25mm thick PCC in cement mortar (1:2:4) type B0 using 12.5mm graded stone aggregate as in sub base, the surface finished fair/rough complete all as specified and directed |
| 33 | M&L for providing Non-skid tiles (approved shade), area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm (square/rectangular), as per IS 15622: 2017 and IS 13712: 2019, group B1b, having thickness not less than 7mm, premium quality having water absorption should be between 3% to 6%, straight edge/rectified, stain free, laid as in Flooring, set and jointed in Neat grey Cement Slurry and pointed in White/Coloured Cement, laid over and including 15mm thick Screed Bed in Cement Mortar (1:4), complete all as specified and as directed. |
| 34 | M&L for providing glazed ceramic coloured tiles (any shade in any pattern of light & dark, with or without highlighters etc as approved), as per IS 15622: 2017 and IS 13712: 2019, group B IIa, having thickness not less than 7mm, Premium quality having water absorption should be between 3% to 6%, straight edge/rectified, stain free, size of tile 350x250mm/ 450x300mm or any size between area of each tile exceeding 0.06 Sqm and not exceeding 0.18Sqm thick as direcetd as in Vertical Surface/Dado etc., set and jointed in Neat grey Cement Slurry and pointed in White or Colour Cement to match the Tiles, laid over and including 10mm thick Screed Bed in Cement Mortar (1:4), complete all as specified and as directed. |
| 35 | M&L for providing vitrified tiles (approved light shade), as per IS 15622: 2017 and IS 13712: 2019, group B Ia, having thickness not less than 8mm, premium quality having water absorption should be between 0% to 0.5%, straight edge/rectified, stain free, area of each tile exceeding 0.18 Sqm but not exceeding 0.42 Sqm (square/rectangular), as in Flooring and connected skirting, set and jointed in Neat grey Cement Slurry and pointed in White/Coloured Cement, laid over and including Screed Bed 15mm thick for floor and 10mm for skirting in Cement Mortar (1:4), complete all as specified and as directed. |
| 36 | Dismantling of stone slab/tiling including cement mortar bedding ( but not backing) and including removing rubbish material from building/from the site to outside MOD land complete all as specified and as directed. |
| 37 | Material and labour 16-18mm thick Granite stone slab (thappi) in approved shade (like dark black, mahroom etc), machine cut, duly factory grinding and polishing (table rubbed and polished), as in table tops, steps, treads, risers, jambs, pillars, window cills, cooking platforms, for counter sunk wash basin, Reception Counter and like or similar locations where directed, set & jointed in and including neat cement slurry, laid over and including 15mm thick cement mortar (1:4) screed bed, and pointing in white cement mixing with pigment to match with shade of slab, including cutting, dressing, edge finishing, rounding of exposed edges where required, including cleaning and extra polishing if required complete all as specified and as directed.Note : (i) Single piece should be used in steps/jambs/shelves, equal to width of slab (ii) The rate shall be deemed to include for accommodating holes/openings for gas pipes in kitchen cooking platforms and cutting for countertop/table top/under-counter wash basins, wherever required to suit the dimensions of the item being fixed. No extra payment shall be admissible on this account. |
| 38 | Material and labour for providing and fixing machine-cut Kota stone slabs, 16–18mm thick (minimum), of approved quality, colour and shade, Kota stone size of slab not less than 550x500mm, as in flooring, cut to the required size and shape, dressed true, set and jointed in position over and including a 15mm thick cement mortar (1:4) screed bed, laid to the required line, level and slope, with neat cement slurry. The work shall include cutting, dressing, trimming, machine finishing, forming mitred joints where required, pointing joints with white cement mixed with suitable matching pigment to match the colour and shade of the stone, rubbing, grinding and final polishing by machine/hand-held polishing machine to produce a smooth, even and lustrous finish, complete in all respects, as specified and directed by the Engineer-in-Charge. |
| 39 | Material and labour for providing and fixing machine-cut Kota stone slabs, 16–18mm thick (minimum), of approved quality, colour and shade, in stair treads, risers, landings, skirting, dado, pillar cladding and other similar locations, cut to the required size and shape, dressed true, set and jointed in position over and including a 10mm thick cement mortar (1:3) screed bed, laid to the required line, level and slope, with neat cement slurry. The work shall include cutting, dressing, trimming, machine finishing, forming mitred joints where required, rounding or chamfering exposed edges, pointing joints with white cement mixed with suitable matching pigment to match the colour and shade of the stone, rubbing, grinding and final polishing by machine/hand-held polishing machine to produce a smooth, even and lustrous finish, complete in all respects, as specified and directed by the Engineer-in-Charge. |
| 40 | Supply and fixing in replacement along wall or laying in trench 160mm nominal outside diameter PVC-U SWR (Soil, Waste and Rainwater) single socketed pipes, Type 'B', conforming to IS 13592, in any required length, laid truly to line and gradient with rubber ring joints using approved pipe joint lubricant as recommended by the manufacturer. The work shall include supplying and fixing all necessary fittings such as bends, tees, single and double Y-junctions, double tees, couplers/sockets, reducers, offsets, access fittings, end caps, plugs and other fittings of any angle or radius, with or without access doors, as required for completing the pipeline system. The item shall also include cutting the pipes to the required length, jointing, making necessary connections to the existing or new SWR system, providing proper alignment, testing the completed pipeline for leakage and satisfactory flow, and all labour, tools, plant and incidental works necessary to complete the work in all respects, as specified and directed by the Engineer-in-Charge.Notes:(i) Brackets, clamps, slotted channels, nuts, bolts, anchor fasteners, supporting arrangements and other fixing accessories shall be measured and paid for separately under the relevant BOQ items.(ii) Measurement for payment shall be made for the actual centre-line length of pipe laid, measured along the pipeline alignment between the centre lines of successive fittings, irrespective of the number of joints. No separate payment shall be made for the socket portion of the pipe, insertion length within sockets/joints, or for fittings such as bends, tees, reducers, junctions, couplers, vent cowls and similar fittings, the cost of which shall be deemed to be included in the quoted unit rate. |
| 41 | Supply and fixing in replacement along wall or laying in trench 110mm nominal outside diameter PVC-U SWR (Soil, Waste and Rainwater) single socketed pipes, Type 'B', conforming to IS 13592, in any required length, laid truly to line and gradient with rubber ring joints using approved pipe joint lubricant as recommended by the manufacturer. The work shall include supplying and fixing all necessary fittings such as bends, tees, single and double Y-junctions, double tees, couplers/sockets, reducers, offsets, access fittings, vent cowls, end caps, plugs and other fittings of any angle or radius, with or without access doors, as required for completing the pipeline system. The item shall also include cutting the pipes to the required length, jointing, making necessary connections to the existing or new SWR system, providing proper alignment, testing the completed pipeline for leakage and satisfactory flow, and all labour, tools, plant and incidental works necessary to complete the work in all respects, as specified and directed by the Engineer-in-Charge.Notes:(i) Brackets, clamps, slotted channels, nuts, bolts, anchor fasteners, supporting arrangements and other fixing accessories shall be measured and paid for separately under the relevant BOQ items.(ii) Measurement for payment shall be made for the actual centre-line length of pipe laid, measured along the pipeline alignment between the centre lines of successive fittings, irrespective of the number of joints. No separate payment shall be made for the socket portion of the pipe, insertion length within sockets/joints, or for fittings such as bends, tees, reducers, junctions, couplers, vent cowls and similar fittings, the cost of which shall be deemed to be included in the quoted unit rate. |
| 42 | Supply and fixing in replacement along wall or laying in trench 75mm nominal outside diameter PVC-U SWR (Soil, Waste and Rainwater) single socketed pipes, Type 'B', conforming to IS 13592, in any required length, laid truly to line and gradient with rubber ring joints using approved pipe joint lubricant as recommended by the manufacturer. The work shall include supplying and fixing all necessary fittings such as bends, tees, single and double Y-junctions, double tees, couplers/sockets, reducers, offsets, access fittings, vent cowls, end caps, plugs and other fittings of any angle or radius, with or without access doors, as required for completing the pipeline system. The item shall also include cutting the pipes to the required length, jointing, making necessary connections to the existing or new SWR system, providing proper alignment, testing the completed pipeline for leakage and satisfactory flow, and all labour, tools, plant and incidental works necessary to complete the work in all respects, as specified and directed by the Engineer-in-Charge.Notes:(i) Brackets, clamps, slotted channels, nuts, bolts, anchor fasteners, supporting arrangements and other fixing accessories shall be measured and paid for separately under the relevant BOQ items.(ii) Measurement for payment shall be made for the actual centre-line length of pipe laid, measured along the pipeline alignment between the centre lines of successive fittings, irrespective of the number of joints. No separate payment shall be made for the socket portion of the pipe, insertion length within sockets/joints, or for fittings such as bends, tees, reducers, junctions, couplers, vent cowls and similar fittings, the cost of which shall be deemed to be included in the quoted unit rate. |
| 43 | Supply & fixing in replacement PVC-U floor trap/gully trap of size 110x75mm, suitable for 75mm bore pipe, trap shall be long neck and of sufficient length to ensure that the outlet pipe joint remains completely outside the wall thickness, including stainless steel grating, joints jointing with pipe joint lubricant, including PCC work complete all as specified and as directed. |
| 44 | Supply & fixing Bracket, Stack clamp, nut bolt, fastner, etc suitable for pipe of any dia, all made out of mild steel, shape of bracket and clamp as directed including painting with synthetic enamel paint complete all as specified and as directed by Engineer-in- charge. |
| 45 | Taking up or down Steel Tubing 15mm bore (dia) with Fittings/ Connections, complete all as specified and as directed.Note :- (i) If a concealed pipe is fixed/laid at the same location from where the old pipe is being removed, the cost for cutting chases in the wall and making it suitable for fixing the new pipe, as required, shall be deemed to be included in the quoted unit rate. Nothing extra shall be paid on this account.(ii) Where concealed pipe laying is carried out at a new location (other than the location of the removed old pipe), cutting chases in the wall shall be measured and paid for separately under the relevant item of the BOQ. |
| 46 | Taking up or down Steel Tubing 20mm bore (dia) with Fittings/ Connections, complete all as specified and as directed.Note :- (i) If a concealed pipe is fixed/laid at the same location from where the old pipe is being removed, the cost for cutting chases in the wall and making it suitable for fixing the new pipe, as required, shall be deemed to be included in the quoted unit rate. Nothing extra shall be paid on this account.(ii) Where concealed pipe laying is carried out at a new location (other than the location of the removed old pipe), cutting chases in the wall shall be measured and paid for separately under the relevant item of the BOQ. |
| 47 | Supply and fixing galvanized steel tubing (GI pipe) medium grade 15mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling or laid in floor including cutting and threading of pipe complete all as specified and as directed. |
| 48 | Supply and fixing galvanized steel tubing (GI pipe) medium grade 20mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling or laid in floor including cutting and threading of pipe complete all as specified and as directed. |
| 49 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for welded wire mesh, cutting not exc 10 cm girth in brick wall and making good, complete all as specified and as directed by the Engineer-in-Charge. |
| 50 | Dismantling/taking down old water storage tanks of any description and capacity with float valve, inlet/outlet connection complete all as specified and as directed. |
| 51 | Material and labour for supplying, hoisting and fixing rotational moulded, double-layer, vertical cylindrical polyethylene (PE) water storage tank with closed top, conforming to IS 12701:1996 (with latest amendments), UV stabilised and suitable for potable water storage, having white inner layer and black outer layer (outer layer minimum of 50% of the total wall thickness), of 1000 litres capacity, complete with threaded inlet, outlet, overflow and drain connections with necessary adaptors, tank lid with locking arrangement or threaded type as per manufacturers, and all necessary fittings, supports, nuts, bolts, washers and jointing materials, testing for watertightness, complete, all as specified and directed by the Engineer-in-Charge. |
| 52 | Supply and fixing ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (polythene float) complete, screwed suitable for 20mm bore iron pipe complete all specified and as directed. |
| 53 | Supply and fixing Gun-metal, globe or gate valve nominal size 20 mm, screwed both ends for iron pipe or for unions, as per IS 778-1984, specifies the material grade as per IS 318 LTB2 complete all as specified and as directed. |
| 54 | Supply & fixing in replacement vitreous china wash down water closet pan (pedestal pattern, EWC) white clour (excluding flushing cistern and flush pipe) including connection to drain and to flushing pipe etc., including plastic water closet seat with cover (white clour) closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device complete all as specified and as directed by Engineer-in- charge. |
| 55 | Supply & fixing in replacement vitreous china urinal, half stall type, white, as approved, including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, 32 mm dia full threaded PTMT waste coupling, 32mm dia waste pipe and water spreader, pointing around urinal back in cement mortar, including taking down old urinal with fittings any type complete all as specified and as directed. |
| 56 | Supply and fixing in replacement 10 litres capacity PVC valveless syphonic action type low level flushing cistern as per IS 7231: 2021, white colour with inlet, ball valve, float, handle including brackets and 32mm dia PVC flush pipe complete all as specified and as directed. |
| 57 | Supplying and fixing in replacement premium quality health faucet (hand-held bidet spray) with ABS body, ergonomically designed trigger-operated spray head having chrome-plated finish, complete with 1.0–1.2 metre long, 8 mm dia flexible stainless steel braided hose with chrome finish, wall hook/bracket, all necessary fittings, screws, plugs and fixing accessories, include making connection to the angle valve complete all as specified and directed by the Engineer-in-Charge. |
| 58 | Supply and fixing in replacement toilet paper holder with flat recessed type stainless steel complete all as specified and as directed by Engineer-in-Charge. |
| 59 | Supply and fixing in replacement corner glass shelf of approx. size 300x300mmx150mm, fancy type, 5.5 to 6mm thick toughened glass, with CP bracket and gurad railing, fixed along wall with CP brass screws and PVC plug complete all as directed by Engineer-in-charge. |
| 60 | Supplying and fixing in replacement vitreous china wash basin, white, flat back, of size 550mm x 400mm or nearest standard size, including 32 mm chromium-plated brass waste coupling, and 32 mm PVC flexible corrugated (spring type) waste pipe of minimum 600 mm length, WHB shall be fixed on existing bracket or new bracket if required as per site requirement or erecting with long screwed shanks & fly-nuts, sealing gap between wall and basin with silicone sealant, complete all as specified and as directed. Note ;- Cost of bracket/ long screwed as per requirement including cutting and making good the walls with PCC and cement mortar shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account |
| 61 | Supply and fixing in replacement Regular Body of Concealed Stop Cock, CP, with exposed part with wall flange suitable for 15mm line with protection cap fixed in position complete all as specified and as directed. |
| 62 | Supply and fixing in replacement Angular Stop Cock with wall flange, CP, screwed down, screwed for 15mm bore brass ferrule or for union and fixed in position complete all as specified and as directed. |
| 63 | Supply and fixing in replacement Bib taps, CP, fancy type, long body with wall flange screwed for 15mm bore brass ferrule and fixed in position complete all as specified and as directed. |
| 64 | Supply and fixing in replacement pillar tap, CP, capstan head, screwed for 15mm bore brass ferrule/PVC connection and fixed in position complete all as specified and as directed. |
| 65 | Supply and fixing Chromium plated overhead shower 125mm dia with shower arm 195mm long for wall mounted shower with flange complete all as specified and as directed. |
| 66 | Supply and fixing in replacement PVC connection 15 mm size of length 450 mm with PTMT nuts of approved quality complete all as specified and as directed by Engineer-in-charge. |
| 67 | Supply and fixing in replacement soap dish, made of stainless steel, rectangular type, of size not less than 115 mm × 85 mm, suitable for accommodating a standard soap bar, fixed to the wall with CP brass screws and PVC plugs, complete all as specified and as directed by the Engineer-in-Charge. |
| 68 | Supply and fixing in replacement stainless steel towel rail, 20mm dia, 600mm long , including bracket and all fixing accessories complete all as specified and as directed. |
| 69 | Supply and fixing in replacement steel sink without drain board for kitchen use, Approx overall size 495mm x 420mm with bowl size 410mm x 355mm x 185mm, manufactured from AISI 304 grade stainless steel sheet of minimum 1.00 mm thickness with glossy/mirror finish. The item shall include 32 mm dia chromium-plated brass waste coupling, flexible corrugated/spring-type PVC waste pipe of minimum 600 mm length, all necessary unions, connectors, clamps and accessories required for proper functioning of the sink. The sink shall be fixed on the existing platform/slab or existing brackets, and where required, new brackets of suitable size and strength shall be provided and fixed without any extra cost. The work shall also include sealing the junction between the sink and wall/platform with approved silicone sealant, connecting the waste outlet to the existing waste pipe system, testing for leakage, making good all disturbed surfaces in cement mortar (1:3) or PCC (1:2:4) as required, and all cutting, fitting and fixing operations, complete in all respects as specified and directed by the Engineer-in-Charge.Note:(i) No extra payment shall be admissible for brackets, waste fittings, pipe connections, sealant, minor modifications to existing slabs/platforms, making good works or any other incidental item required for completion of the work. |
| 70 | Supply and fixing in replacement stainless steel peg set of six hooks, 45 cm long (as per sample) and fixed in position with steel screws complete all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
| 71 | Supply and fixing in replacement stainless steel peg set of six hooks, 45 cm long (as per sample) and fixed in position with steel screws complete all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysNov 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender