Tender For Providing Of Certain Or Married Accommodation At Garhi Cantt
BOQ
| Sl. No. | Item Description |
| 1 | PHASE - ISCHEDULE 'A' PART-I (BUILDING WORK) |
| 2 | Construction of 01 x Building Block for 24 x OR's Married Accommodation (Quarters) upto (S+6) multistorey building with permanent specifications, RCC framed construction, ATT, including stilt parking, Lift shaft, electric shaft, staircase, Fire escape stair case, Lobby, Horizontal Corridors, baggage room, Meter Room, 25000 Ltr capacity RCC water tank on top of roof for fire fighting, raised RCC platform for water tanks, pergola, mumty, ramp etc complete all as shown on drawings, specified and directed |
| 3 | Construction of 01 x 110000 Ltr capacity under ground circular RCC water sump complete all as shown on drawings and specified and directed |
| 4 | Total amount of SCHEDULE 'A' Part - II A(INTERNAL WATER SUPPLY)(For details see Sch 'A' in PDF folder) |
| 5 | SCHEDULE 'A' PART - II B (INTERNAL WATER SUPPLY) |
| 6 | S&F for Health faucet (ABS body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 m long flexible SS pipe tube and ABS wall hook including making connections and fixed in position complete in all as specified and directed. |
| 7 | S & F 15 mm bore two way bib cock with wall flange cast copper alloy , fancy type , chromium plated, screwed for for GI/ iron pipe or for brass ferrule including flange and fixed complete all as specified and directed. Make : Cera Cat Part No. F2002161, Hindware cat part No. F400003CP, Johnson Model No. T1408CAMZ, Somany SAP Code 272211250051 and equivalent in approved make list as approved by Engr-in-Charge. |
| 8 | S&F 15 mm dia bore Brass chromium plated wash hand basin mixer central hole for making (HOT & COLD) water fixed as per manufacturers manual along with accessories with long shunk and cup washers, screwed both ends for GI/ iron pipe or for brass ferrule including flange complete all as specified and directed. Make : Hindware cat part No F200014CP, Jaquar Continental CON-CHR-167KNB, Cera Cat No. F2002461 and equivalent in approved make list as approved by Engr-in-Charge. |
| 9 | S&F 15 mm dia bore Brass chromium plated wall mixture 2 in 1 system (HOT & COLD) with wall flange and two way suitable for GI/ iron pipe or for brass ferrule including flange and fittings including three joints to GI pipe or unions and plugging and screwing to walls , inluding L bend for mixing hot or cold for shower connection etc all as specified and directed. Make Hindware cat part No. F570020CP , Cera Cat part No. F2008401 , Asian Paints BathSense CODE : CLWM103 and equivalent in approved make list as approved by Engr-in-Charge. |
| 10 | S & F 15 mm bore Brass chromium plated sink mixer swinging spout (wall mounted model) (HOT & COLD) with connecting legs and wall flanges screw down for fixed to GI pipe or brass ferrule etc and fittings or for unions and fixed complete all as specified and directed. Make Hindware cat part No. F570027CP, CERA cat part No. F2002511, Johnson Model NoT1476CAMZ and equivalent in approved make list as approved by Engr-in-Charge. |
| 11 | S&F for brass chromium plated over head shower rose 150 mm size (round/square pattern) revolving type multi-flow including 300 mm long CP shower arm suitable for fixed to GI pipe and fittings or for unions and fixed complete all as specified and directed. |
| 12 | SCHEDULE 'A' PART - III(INTERNAL ELECTIFICATION WORK) |
| 13 | M & L point wiring for one light/Bulb/Security light point/Ex fan complete with and including single core PVC insulated unsheathed flexible bright annealed multi stranded copper conductor FRLS (H) cables 1.5 Sqmm (22/0.30 mm) 1100 volts grade drawn through and including heavy grade PVC rigid conduits 20 mm or higher dia as reqd at site, totally concealed in walls/floors/ceiling including all conduit accessories/ fittings/ junction boxes/ inspection covers etc; of heavy grade, ISI marked and sunken terminal boxes of factory made 16 SWG pressed steel housing, totally concealed in walls with 3 mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk/cup washers, for mounting of switches, sockets fan regulates etc; including 1.5 Sqmm (22/0.30 mm) 1100 V grade PVC insulated, unsheathed flexible multi stranded copper conductor FRLS (H) cable as continuous earth wire connected to metallic bodies of luminaries/fans etc; at one end and to common earth dolly at other end, all as specified & directed for the following up to Item No. 14 (a) to 20 (f) (Note: (i) Chase cutting for concealed work and making good shall deemed to be included in quoted lumpsum amount of respective Building under Schedule 'A' Part-I.(ii) Colour code shall be maintained as per IE rule) |
| 14 | (a) One tube light/Bulb point or one fan point controlled by one, one way switch 05 / 06 Amps. |
| 15 | (b) One Ceiling fan point controlled by one, one way switch 05 / 06 Amps. |
| 16 | (c) One light point controlled by two way switch 05 / 06 Amps. |
| 17 | (d) One light point controlled by two 2 way switch |
| 18 | (e) One bell/ buzzer point controlled by one push button on the same board with other or independent switch 05 / 06 Amps. |
| 19 | (f) One three pin 05 / 06 Amps socket outlet point on same board with other switches including earth wire as per description given above and connected earth and earth terminal. |
| 20 | (g) One three pin 05 / 06 Amps socket outlet point on independent board including earth wire as per description given above and connected earth and earth terminal. |
| 21 | M & L point wiring for one light/Bulb/Security light point/Ex fan complete with and including single core PVC insulated unsheathed flexible bright annealed multi stranded copper conductor FRLS (H) cables 1.5 Sqmm (22/0.30 mm) 1100 volts grade drawn through and including heavy grade PVC rigid conduits 20 mm or higher dia as reqd at site, totally concealed in walls/floors/ceiling including all conduit accessories/ fittings/ junction boxes/ inspection covers etc; of heavy grade, ISI marked and sunken terminal boxes of factory made 16 SWG pressed steel housing, totally concealed in walls with 3 mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk/cup washers, for mounting of switches, sockets fan regulates etc; including 1.5 Sqmm (22/0.30 mm) 1100 V grade PVC insulated, unsheathed flexible multi stranded copper conductor FRLS (H) cable as continuous earth wire connected to metallic bodies of luminaries/fans etc; at one end and to common earth dolly at other end, all as specified & directed for one 16A, 6-Pin socket outlet point on independent board with & including 2.5 Sqmm FRLS (H) cable as earth wire complete.(Note: (i) Chase cutting for concealed work and making good shall deemed to be included in quoted lumpsum amount of respective Building under Schedule 'A' Part-I.(ii) Colour code shall be maintained as per IE rule) |
| 22 | S&F switch modular type 6 Amps one way one module 230 volts white /ivory finish all as specified and as direcrted |
| 23 | S&F switch modular type15/16 Amps one way one module 230 volts white /ivory finish all as specified and as directed |
| 24 | S&F bell push modular type 6 Amps one module 230 volts white /ivory finish all as specified and as directed |
| 25 | S&F switch modular type 6 Amps two way one module 230 volts white /ivory finish all as specified and as directed |
| 26 | S&F socket outlet modular type 6 Amps, 2/3 pin combined two modules suitable for 3 pin/2 pin 5 Amp plug tops, complete all as specified and directed. |
| 27 | S&F modular socket 16 Amp -2/3 pin combined 2 module complete all as specified and as directed |
| 28 | S&F ceiling rose surface PVC 50 mm dia 3 terminals including PVC mounting block white/ ivory /urea finish complete all as specified and directed. |
| 29 | S&F bell multi music type, AC, 230 volts, single phase complete all as specified and as directed. |
| 30 | S&F LED Lamp 9/10 Watt, 230 volts 50 Hz AC complete all as specified and as directed. |
| 31 | S&F of LED Batten with aluminum extruded channel(housing) and polycarbonate diffuser for glare free light with input power 20 Watt , system efficiancy not less than 120 lm/watt with built in surge protection not less than 2.0 KV with acessories like both side end cap, driver, holder,screw including LED light with flexible sheathed copper conductor cable of suitable size to connect with ceiling rose complete all as directed. |
| 32 | S&F of LED light fitting mirror type with aluminum housing and polycarbonate diffuuser 10 watt 220V AC decorative type with acessories like both side end cap, driver, holder,screw including LED light with flexible sheathed copper conductor cable of suitable size to connect with ceiling rose complete all as directed. |
| 33 | S&F lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. |
| 34 | Supply & fixing and Testing TP & N Vertical load line (VTPN) 4 way 415 Volts 50 Hz indoor type double door sheet metal enclosure IP-43 DB's IK-09 flush mounted with 160 Amp Copper busbar for each phase with two neutral bar & two earthbar and cable ties for cable management suitable for MCCB 100 Amps,ICs=100%ICu, 16KA four pole as in comer including connecting terminal strip complete and SP MCBs as out going etc complete pre wired with suitable size copper conductor. The DB's shall hold type test certificate (CPRI) as per IEC 61439-3 complete all as specified and directed by Eng-in-charge (Note :- MCB/ MCCB shall be measured and paid separately) |
| 35 | S&F sheet metal enclosure (Factory made), double door shutter type for distribution board (when MCBs are to be used), single pole and neutral, 240 volts, 12 way, protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, suitable for flush mounting and surface mounting, with 100 Amps rated copper busbar, with Neutral bar, Earthbar and cable alley for cable managment, fully shrouded, Neutral bars, prefittes masking sheet complete all as specified and as directed |
| 36 | S&F sheet metal enclosure (Factory made), double door shutter type for distribution board (when MCBs are to be used), single pole and neutral, 240 volts, 4 way, protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, suitable for flush mounting and surface mounting, with 100 Amps rated copper busbar, with Neutral bar, Earthbar and cable alley for cable managment, fully shrouded, Neutral bars, prefittes masking sheet complete all as specified and as directed. |
| 37 | S&F MCB SP, C Curve, 6 to 32 Amps 10 KA single pole AC 230 volts complete all as specified and as directed. |
| 38 | S&F MCB SPN, C Curve, 40-63 Amps 10 KA single pole AC 230 volts complete all as specified and as directed. |
| 39 | S&F MCCB 63 Amp 16 KA, 415 V, 4 pole complete all as specified and as directed. |
| 40 | M &L for sub main wiring with 2 single core FRLS (H) PVC insulated unsheathed, multi stranded flexible copper conductor 1100 volts grade cables 4.0 Sqmm drawn through & including concealed PVC conduit heavy grade with and including 1 single core 4.0 Sqmm 1100 V grade FRLS (H) PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified & directed. (For AC & Geyser Point) Note 1: 3 runs ( 2+1) of single core FRLS (H) PVC insulated unsheathed multi stranded flexible copper conductor and one run of PVC conduit heavy duty shall be measured as one unit. Note 2: Rate quoted is deemed to be inclusive for cutting chases in wall for concealed wiring & making good disturbed surfaces to match existing. |
| 41 | M &L for sub main wiring with 2 single core FRLS (H) PVC insulated unsheathed, multi stranded flexible copper conductor 1100 volts grade cables 6.0 Sqmm drawn through & including concealed PVC conduit heavy grade with and including 1 single core 6.0 Sqmm 1100 V grade FRLS (H) PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified & directed. (VTPN to SDB)Note 1: 3 runs ( 2+1) of single core FRLS (H) PVC insulated unsheathed multi stranded flexible copper conductor and one run of PVC conduit heavy duty shall be measured as one unit. Note 2: Rate quoted is deemed to be inclusive for cutting chases in wall for concealed wiring & making good disturbed surfaces to match existing) |
| 42 | S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amp 240 Volts complete all as specified and as directed. |
| 43 | Supply and fix electric water heater,storage type steel body with Enamel coated steel inner tank, and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, 02 Nos of PVC Connections 18\\" long of suitable size not less than 15 mm bore with washers on both sides, including necessary pipe line connection complete with all acessories all as specified and directed . |
| 44 | Supply & fix Ceiling fan, 1200 mm sweep with BLDC motor, energy saving, after assembling the same with the fan/hook/box / fan regulator and connecting up complete with and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to porcelain connector block of fan complete all as specified and as directed. |
| 45 | Supply and fix Exhaust fan metal body exhaust fan 300mm sweep including louvers, 1400 RPM single phase light, one number of speed set, fixing by means of rugged bolts, nuts and washers etc on round hole cut in wall, including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to porcelain connector block of exhaust fan suitable on working AC,SP 230 v electric supply including making the opeaning as per reqd size complete all as specified and directed. |
| 46 | Supply and fix Exhaust fan made of sturdy engineering plastic complete with louvers shutter 230 volt 50 HZ RPM 1200 copper winding of sweep 250 mm and fixing the exaust fan in the space provided in window shutters of toilets & bathrooms including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to exaust fan all as specified and as directed. |
| 47 | S&F 35 Watt building mounted LED security light fitting complete made up of pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 & 10KV external SPD, including GI bracket made out of GI pipe 40/50 mm bore, medium grade pipe 1.2m long bend to shape required fixed to pole / wall with 02 Nos MS clamps made out of flat iron 40x5 mm including nuts, bolts and washer, painting with two coats aluminium paint over a coat of primer, suitable for LED fitting complete all as specified and as directed. |
| 48 | Supplying, laying and testing LT XLPE underground cable of size 25 sqmm 3.5 core heavy duty, 1100 Volts, PVC insulated and sheathed, armoured with multi-stranded aluminium conductor cable conforming to latest IS , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/ drains/culverts duly protected in galvanised steel pipe of suitable sizes all bare conductor of cable duly insulated 1.1 KV grade heat shrinkable sleeve including cable gland and lugging etc at both ends all complete all as specified and directed. |
| 49 | Total amount of SCHEDULE 'A' PART - IV(SITE CLEARANCE AND EARTHWORK) (For details see Sch 'A' in PDF folder) |
| 50 | SCHEDULE 'A' PART - V(LIFTS) |
| 51 | Supplying, Installation, Testing & Commissioning of 884 Kgs Machine room less (MRL) 13 Passanger LIFT with regenerative drive as per, NBC 2016 as amended upto date, serving different floors in the lift shaft as per detailed specification enclosed and as under including all other equipment and accessories complete all as required. (i) Speed - 1.00 MPS, (ii) Floors - 7 story (Stilt parking + 6 floors ) (multistory building)(iii) Stops & opening: 7 No stops and 7 No openings (iv) Controller: A.C. variable voltage & variable frequency (v) Automatic rescue device (ARD) complete with dry maintenance free batteries as required. (vi) Operation: Microprocessor based simplex selective collective control with/without attendant including micro processor based VVVF- Closed Loop.(vii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system and light power system 220 volts.(viii) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless steel decorative ceiling with fans (cross flow) and LED fitting. |
| 52 | And landing Door finish: 1-7 SS - Hairline, Landing Door Frame : 1-7 SS - Hairline finish, Main landing floor : G, other landing floors : 1,2,3,4,5,6 and Jamb type : Slim floor.(ix) The car flooring should be strong to take the rated load without any deformation or damage and antiskid as approved by Engineer-in-Charge. (x) Type of doors: - (a) Car: Power operated, center opening horizontal sliding stainless steel scratch cock/Honeycomb/ Hairline Finish). proof (Moon) with door sill : Aluminium.(b) Landing doors: 1-7 stainless steel - hair line. (xi) A hand rail not less than 600 mm long at 900 mm above floor level to be fixed adjacent to control panel in the lift car and type is SS round Handrail. (xii) Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator. |
| 53 | (xiii) Closed loop Control System, protection against power fluctuation, self diagnostic control, call register signal, stainless steel Braille button, Landing doors 2 hours Fire rated, Overload detection and protection, Overspeed Governor, Dot Matrix LED D & P Indicators In Car & Landings, BMS Compatibility, door protection infra red door screen, overload indicator, fireman switch, automatic rescue device, tamper proof infrared curtain covering almost the entire height of the lift car door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable NVR and HDD for 30 days storage backup, Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup for fan and light for 1 hour, pit ladder. (xiv) In case of failure of ARD or other electronic. Note : Makes for lifts : OTIS Elevator / Kone India/Schindler India Pvt Ltd/Hitachi Lifts |
| 54 | Supplying, Installation, Testing & Commissioning of 544 Kgs Machine room less (MRL) 08 Passanger LIFT with regenerative drive as per, NBC 2016 as amended upto date, serving different floors in the lift shaft as per detailed specification enclosed and as under including all other equipment and accessories complete as required. (i) Speed - 1.00 MPS (ii) Floors - 7 story (Stilt parking + 6 floors ) (multistory building)(iii) Stops & opening: 7 No stops and 7 No openings (iv) Controller: A.C. variable voltage & variable frequency (v) Automatic rescue device (ARD) complete with dry maintenance free batteries as required. (vi) Operation: Microprocessor based simplex selective collective control with/without attendant including micro processor based VVVF- Closed Loop.(vii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system and light power system 220 volts.(viii) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless steel decorative ceiling with fans (cross flow) and LED fitting. |
| 55 | And landing Door finish: 1-7 SS - Hairline, Landing Door Frame : 1-7 SS - Hairline finish,Main landing floor : G, other landing floors : 1,2,3,4,5,6 and Jamb type : Slim floor.(ix) The car flooring should be strong to take the rated load without any deformation or damage and antiskid as approved by Engineer-in-Charge.(x) Type of doors: - (a) Car: Power operated, center opening horizontal sliding stainless steel scratch cock/Honeycomb/ Hairline Finish). proof (Moon) with door sill : Aluminium.(b) Landing doors: 1-7 stainless steel - hair line. |
| 56 | (xi) A hand rail not less than 600 mm long at 900 mm above floor level to be fixed adjacent to control panel in the lift car and type is SS round Handrail.(xii) Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator. (xiii) Closed loop Control System, protection against power fluctuation, self diagnostic control, call register signal, stainless steel Braille button, Landing doors 2 hours Fire rated, Overload detection and protection, Overspeed Governor, Dot Matrix LED D & P Indicators In Car & Landings, BMS Compatibility, door protection infra red door screen, overload indicator, fireman switch, automatic rescue device, tamper proof infrared curtain covering almost the entire height of the lift car door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable NVR and HDD for 30 days storage backup, Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup for fan and light for 1 hour, pit ladder.(xiv) In case of failure of ARD or other electronic.Note : Makes/ Brand for lifts : OTIS Elevator / Kone India/Schindler India Pvt Ltd/Hitachi Lifts |
| 57 | Note for Item No-51 & 54 :- Lifts have comprising of following specifications : (a) Electrically operated with electric motor AC 415 volts , 3 phase 50 HZ of suitable capacity as per IS (efficiency class equivalent to IE 2)(b) Electric cabling and wiring in FRLS copper cable including all necessary PVC Conduits ISI marked of suitable size .( c) Micro processor based VVVF type main controller with closed loop system.(d) Car position indicator in car all fixture in SS face plate (both inside/outside) . All buttons should be with brail marking and luminous.(e) Provn of travelling cable with copper conductor FRLS of suitable size & core or required wiring to intercom speaking & other acessories.(f) Inbuilt ARD (Automatic Rescue Device) with maintenance free batteries operated to bring the car cage to the nearest floor level in case of power failure , which includes power failure of one or more phase. Emergency light and at least one fan inside the lift car shall be operation till the rescue operation and an audio and visual indicator shall be provided inside car to alert the person trapped inside that they are being rescued. |
| 58 | (g) Provision of governer and governer rope of suitable size, buffer springs as per manufacture's design , car cabin powered doors and inspection box at top of the car cabin , compacr high efficiency drive combined with suspension Traction media Technology , Grooved belt and alongwith belt monitoring device which can ensure to prevent from any breakages of belt and taking elevator nearest landing.(h) Provision of safety guarding equipments such as 02 nos pit switches controller , guarding pit pulley ,guarding pit ladders , facia plate to cover free space between car cabin and hoist way & switches.(j) Door sensor not less than 74 beam , 2D Infra red full length.(k) Provision of fire man switch complete at ground floor fitted in box including SS face plate.(l) Provision of \\"Press and speak \\" system to be coconnected with lift complaint cell compatible with wxchange , provision of Automatic call registration in case of break down(m) Do's & Don’ts chart on stainless steel sheet min 5 mmm thick of size not less than 18x12 inch to be installed inside the car cabin. |
| 59 | (n) A three pin plug socket with switch for hand lamp shall be fitted on top of the lift car for use by person working there on.(p) Provn of transparent space for highlights the imp instructions and mobile Nos.(q) Provn of RCCB/RCBO in SS enclosure.( r) Provn of over load indicator.(s) Fire rating of landing doors should be one hour minimum. |
| 60 | SCHEDULE 'A' PART - VI(HOT WATER SUPPLY) |
| 61 | Supply and fixing of electric water heater, storage type ABS body with glass lined inner tank, and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, including 02 Nos of stainless steel leak proof geyser Connections 24\\" long of suitable size not less than 15 mm bore with washers on both sides, fixed on wall complete with all acessories all as specified and directed.Make :- Havells/Crompton/ Bajaj/Orient |
| 62 | S&F sheet metal enclosure, SPN with 2 pin and earth plug and socket complete with and including single pole ,20 Amps MCB, 240V (for Geyser) all as specified and as directed . |
| 63 | M &L for sub main wiring with 2 single core FRLS PVC insulated unsheathed, multi stranded flexible copper conductor 1100 volts grade cables 4.0 Sqmm drawn through concealed conduit and including PVC conduit heavy grade with and including 1 single core 4.0 Sqmm 1100 V grade FRLS PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals including taking down old sub main wiring complete all as specified and as directed. Note: Three runs of 4.0 Sqmm cable and one run of PVC Conduit will be measured as one unit. |
| 64 | SCHEDULE 'A' PART - VII(CABLE NET WORKING) |
| 65 | M & L TV Wiring with Co axial RG-6 heavy duty PVC insulated, PVC sheathed cable having single strand of 0.7 mm dia taped in concealed PVC conduit suitable for television wiring including all necessary connections from terminal box to TV socket, drawn in separate concealed PVC conduit complete all as directed. Make : Standard/ Havells/ RR/ Glosters Cable. |
| 66 | S & F modular design TV socket for cable connection complete all as specified and as directed. ( Makes : Havells, Schneider, Legard and equivalent) |
| 67 | M & L rigid non metallic PVC conduit of 25 mm dia inclusive of all tees, bends elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc but exclusive junction/terminal boxes for computer/TV/ telephone /LAN networking and communication system and cutting chases for concealed concealed conduit wiring, etc complete all as specified & directed. |
| 68 | S & F modular Metal flush box 1/2 module complete all as specified and as directed. |
| 69 | S & F Modular white cover plate with frame 1 module complete all as specified and as directed. |
| 70 | SCHEDULE 'A' PART - VIII(LIGHTENING PROTECTION ) |
| 71 | M & L for earthing with copper plate 600 mm × 600 mm × 3.15 mm thick electrode burried directly in ground earth pit not less than 2.25metres deep below ground level )with top edge of the plate not less than 1.5 metres below ground level ,connected to 20×3mm copper strip as earthing lead by means of bolts, nuts ,check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point including earth test point including excavation, earthwork, PCC pit, RCC cover 50mm thick, funnel with 20mmmdia medium grade GI watering pipe, wire mesh and testing on completion all as specified and as directed. |
| 72 | Supply and fixing of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x3 mm aluminium strip with saddles / insulators at 50cm distance, complete all as specified and directed. |
| 73 | M & L Test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm, drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws, complete all as specified and as directed. |
| 74 | M & L Single pointed air termination Copper rod , 12 mm dia , 300 mm long, complete all as specified and as directed. |
| 75 | Material & labour for lightening conductor assembly made out of GI pipe light grade of size 50 mm bore along with welded flange at one end & GI reducer socket 50 x 40mm at another end connected with GI pipe light grade of size 40 mm bore with one end GI reducer socket to connect air termination & connector for earth strip duly fixed with necessary nuts bolts & washers in PCC 1:2:4 type B0 30cm x 30cm x30cm complete all as directed by Engr-in-chargeNote : GI pipe 40/50mm & air temination shall be measured & paid separately under relevant items |
| 76 | Supply only GI pipe light grade of size 40 mm bore for erection of lightening conductor complete as required and directed by Engineer-in-Charge. |
| 77 | Supply only GI pipe light grade of size 50 mm bore for erection of lightening conductor complete as required and directed by Engineer-in-Charge. |
| 78 | M&L for earthing with galvanised steel earth plate electrode 60cm x 60cm x 6.0 mm thick, burried directly in ground (earth pit not less than 2.25metres deep below ground level )with top edge of the plate not less than 1.5 metres below ground level ,connected to galvanised earth strip 32 x 6mm by means of bolts, nuts ,check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point including earth test point including excavation, earthwork, PCC pit, RCC cover 50mm thick, funnel with 20mmmdia medium grade GI watering pipe, wire mesh and testing on completion all as specified and as directed. |
| 79 | M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground( earth pit not less than 2.25 mtrs deep below normal ground level) with the top edges of plate not less than 1.5 mtrs below normal ground level connected to GI wire 4mm by means of GI nuts, bolts check nuts and washers earth lead protected by 15mm dia GI pipe light grade and connected to main distribution board/earthing test point all as shown in electrical plate No 5 of SSR part 1 and all as specified including testing on completion. Notes:-The unit rate also including for excavation, earth work in any type of strata, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix, type B1 cover reinforced with 8mm dia TMT bars @150mm C/C both ways ,GI funnel with watering pipe, wire mesh, protection pipe for earth lead upto 7.50m long complete in addition to item No. 14 (a) to 20 (g) under schedule 'A' part -III , preamble (notes) under sub heading earthing, specified in SSR Part ll. Earth strip beyond 7.5m shall be measured and paid separately. Please Enable Macros to View BoQ information |
| 80 | M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground( earth pit not less than 2.25 mtrs deep below normal ground level) with the top edges of plate not less than 1.5 mtrs below normal ground level connected to GI wire 4mm by means of GI nuts, bolts check nuts and washers earth lead protected by 15mm dia GI pipe light grade and connected to main distribution board/earthing test point all as shown in electrical plate No 5 of SSR part 1 and all as specified including testing on completion. Notes:-The unit rate also including for excavation, earth work in any type of strata, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix, type B1 cover reinforced with 8mm dia TMT bars @150mm C/C both ways ,GI funnel with watering pipe, wire mesh, protection pipe for earth lead upto 7.50m long complete in addition to item No. 14 (a) to 20 (g) under schedule 'A' part -III , preamble (notes) under sub heading earthing, specified in SSR Part ll. Earth strip beyond 7.5m shall be measured and paid separately. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 27 daysDec 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 34 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender