Tender For Repair/ Maintenance Of Central Ac Plant At Various Location Under Ge (Af) Jamnagar No 1
Tender Value
54.99 Lakhs
Estimated cost
Bid Submission
09 Dec 2026
21 days left
EMD
1.07 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jamnagar → Gujarat
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Repair/ Maintenance Of Central Ac Plant At Various Location Under Ge (Af) Jamnagar No 1
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CWE (AF) Jamnagar NAME OF WORK:- REPAIR/ MAINT OF CENTRAL AC PLANT AT VARIOUS LOCATION UNDER GE (AF) JAMNAGAR NO 1 Contract No: CWE (AF) JAM / GE-2/ of 2025-2026 SERIAL PAGE No. Bidder Name : SCHEDULE 'A' (PRICE SCHEDULE)(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Srl.No. Item Description Item Code / Make Approx Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT with all Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Comprehensive / Preventive maintenance including servicing of VRV based air conditioning system with connected indoor and outdoor units detail as under installed under GE(AF) Jamnagar all as specified and directed by Engr-in-charge. (a) Out door unit 12 TR capacity VRV unit of Make -Daikin, Model No - RXYQ12TRY69, Ser No E000352 (b) Indoor unit :- Make-Daikin 10 Nos Hiwall/cassette type |
| 3 | All as per Item No 1 but Out door unit VRV type of Make DAIKIN, Model No RXYQ12TRY69, Ser No E000345 Capacity 12 TR (b) Indoor Unit : - Make Daikin 05 Nos Hiwall/cassette type |
| 4 | All as per Item No 1 but Out door unit VRV type of Make DAIKIN, Model No RXYQ12TRY69, Ser No E000417 Capacity 12 TR (b) Indoor Unit : - Make Daikin 04 Nos Hiwall/cassette type |
| 5 | All as per Item No 1 but out door unit VRV type of Make DAIKIN, ModelNo RXYQ10TRY69 , Ser No E000223 and E000231 Capacity 10 TR(b) Indoor Unit : Make Daikin 04 Nos Hiwall/cassette type |
| 6 | All as per Item No 1 but out door unit VRV type of Make DAIKIN, ModelNo RXYQ10TRY69 , Ser No E000209 and E000198 Capacity 10 TR (b) Indoor Unit : Make Daikin 05 Nos Hiwall/cassette type with each outdoor unit |
| 7 | All as per Item No 1 here-in-before but following capacity (a) Outdoor unit 50 KW capacity VRF unit of Make Hitachi, Model no - RAS18FSXNK, Sr. No. 190G06595 and 190C49566 -02 Nos (b) Indoor unit Make Hitachi 04 Nos Cassette type (02 Nos with each outdoor unit) |
| 8 | All as per Item No 1 here-in-before but following capacity (a) Outdoor unit VRV type of Make Blue Star, Model no - DVRF 12 TC, Sr. No. 12TC16F00001 -01 No (b) Indoor unit :- Make Blue Star 03 Nos Cassette type |
| 9 | Note for Ser No 01 to 07 :- Comprehensive / Preventive maintenance of DVRF/VRF/VRV based air conditioning shall be carried out as per manufacturer standard and all as directed by Engineer-in-Charge and comprising of following Jobs :-(a) Testing / Checking of compressor for its proper functioning .(b) Testing / Checking of control switch such as pressure cut outs, temperature sensor for proper functiong.(c) Testing / Checking of PCBs of the Indoor unit & Outdoor unit for its proper functioning.(e) Testing / Checking of Cooling coil for leakage and Rectification of leakage by brazing including cleaning of Cooling coil. |
| 10 | (f) Testing / Checking & servicing of blower fan motor and rectification of minor defect if any.(g) Testing / Checking of all electrical connection and control wiring tighting of electrical connection and rectification of defect if any complete.(h) Testing / Checking & servicing of condenser fan motor and rectification of defect if any.(j) Cleaning of entire indoor & outdoor unit and removing all dirt dust, grease etc. |
| 11 | (k) Comprehensive / Preventive maintenance including servicing of VRF unit shall be carried out two times during contract period and shall be measured two times. Spare Parts shall be paid under respective items. Labour Cost of replacement of any spare parts pertains to VRF/VRV/DVRF based air conditioning unit are deemed to be included in the quoted rate through out the contract period. (l) Contractor shall also be responsibile to rectify any defect/complaint lodged by user and maintain plant in running condition within 24 Hours during break down without any extra cost during contract period. |
| 12 | Supply only spare parts for maintenance of , VRF/VRV/DVRF type air conditioning unit . Note : Make of VRF/VRV/DVRF unit is Blue star, Hitachi & Daikin therefore spare part provided in the work shall be of existing make , contractor may use spare part of other make suitable with configurtion to existing eqpt as approved by GE. |
| 13 | Supply only main control PCB of indoor Unit of VRF type AC unit complete all as specified and as directed. |
| 14 | Supply only power PCB for indoor unit of VRF AC complete all as specified and as directed. |
| 15 | Supply only hiwall controller to indoor unit of VRF AC complete all as specified and as directed. |
| 16 | Supply only HP/LP sensor to outdoor unit of VRF AC complete all as specified and as directed. |
| 17 | Supply only sensors(Liquid, gas temp, room temp,supply temp) to indoor unit of VRF AC complete all as specified and as directed. |
| 18 | Supply only SMPS Board to Outdoor unit of VRF AC complete all as specified and as directed. |
| 19 | Supply only Over Voltage PCB to outdoor unit of VRF AC complete all as specified and as directed. |
| 20 | Supply only HP Switch to outdoor unit of VRF AC complete all as specified and as directed. |
| 21 | Supply only motor to outdoor unit of VRF AC of any capacity complete all as specified and as directed. |
| 22 | Supply only main power PCB of outdoor unit of VRF AC of any capacity complete all as specified and as directed. |
| 23 | Supply only master controller PCB of outdoor unit VRF AC of any capacity complete all as specified and as directed. |
| 24 | Supply only capacitor board of outdoor unit VRF AC of any capacity complete all as specified and as directed. |
| 25 | Supply only noise filter board of outdoor unit VRF AC of any capacity complete all as specified and as directed. |
| 26 | Supply only sensors (Liquid temp HeX 1&2, Gas temp HeX1&2) of outdoor unit VRF AC of any capacity complete all as specified and as directed. |
| 27 | Supply only Solenoid valve of outdoor unit of VRF AC of any capacity complete all as specified and as directed. |
| 28 | Supply and fxing in repair/replacement of inverter compressor suitable for 12 TR capacity VRV type AC unit (Make Daikin, Model no - RXYQ12TRY69) with base frame & electrical Phase reversal protection comprising following JOB:-(i) Charging of nitrogen Gas in unit & complete system at 300 psi pressure and checking of any dropping of pressure / leakage up to 72 Hrs after replacement of compressor & rectification of leakage if any. (ii) Vaccumisation of complete system for minimum 2 days for dropping of vacuum pressure & rectification of leakage if any. (iii) Charging of complete system with R410 / R407 gas for maintaining the system pressure up to HP - 175 psi & LP - 65 psi....(iv) Measure the inlet and outdoor temperature of package unit. (v) Testing & commissioning of compressor after completion of Job. . |
| 29 | Supply and fxing in repair/replacement of inverter compressor suitable for 10 TR capacity VRF/VRV type AC unit (Make Daikin, Model no - RXYQ10TRY69) with base frame & electrical Phase reversal protection comprising following JOB:-(i) Charging of nitrogen Gas in unit & complete system at 300 psi pressure and checking of any dropping of pressure / leakage up to 72 Hrs after replacement of compressor & rectification of leakage if any. (ii) Vaccumisation of complete system for minimum 2 days for dropping of vacuum pressure & rectification of leakage if any. (iii) Charging of complete system with R410 / R407 gas for maintaining the system pressure up to HP - 175 psi & LP - 65 psi....(iv) Measure the inlet and outdoor temperature of package unit. (v) Testing & commissioning of compressor after completion of Job. |
| 30 | Supply and fixing in repair/replacement PCB card suitable for Cassette type AC for outdoor unit (Set complete) of any capacity(upto 6 TR) complete all as specified and as directed by Engr-in-charge. Make Daikin |
| 31 | Supply and fixing in repair/replacement PCB card suitable for Cassette type AC for indoor unit (set complete) of any capacity(upto 6 TR) complete all as specified and as directed by Engr-in-charge. Make Daikin |
| 32 | M&L for descaling/condenser cleaning of complete copper condenser pipe of central AC Plant Air cooled condenser unit, (34 TR x 4 Nos) Make : Bluestar. circulating suitable descaling compound / solution into the tube with pump and running the pump continuously till all the scale from tube are removed including removing side covers of condenser and cleaning the copper tubes by means of nylon brushes till the complete scaling is removed and refixing of covers including replacement of rubber gasket and refixing pipe connection etc. all as specified and directed to complete satisfaction of Engineer-in-charge. |
| 33 | M&L for descaling of complete copper condenser pipe of water cooled central type AC plants (30 TR x 3 Nos ) capacities by circulating suitable descaling compound / solution into the tube with pump, and running the pump continuously till all the scale from tube are removed including removing side covers of condenser and cleaning the copper tubes by means of nylon brushes till the complete scaling is removed and refixing of covers including replacement of rubber gasket and refixing pipe connection etc. all as specified and directed to complete satisfaction of Engineer-in-charge. |
| 34 | M&L for descaling/condenser cleaning of complete copper condenser pipe of central AC Plant Air cooled condenser unit, (22 TRx 3 Nos) Make : Bluestar. circulating suitable descaling compound / solution in--to the tube with pump, and running the pump continuously till all the scale from tube are removed including removing side covers of condenser and cleaning the copper tubes by means of nylon brushes till the complete scaling is removed and refixing of covers including replacement of rubber gasket and refixing pipe connection etc. all as specified and directed to complete satisfaction of Engineer-in-charge.Note :- contrator will carried out descaling work during contract period as directed by Engineer -in-charge as per requirement . |
| 35 | M&L for descaling of complete copper condenser pipe of central AC Plant Air condenser unit, (60TR x 3 Nos) Make : VOLTAS. circulating suitable descaling compound / solution in--to the tube with pump, and running the pump continuously till all the scale from tube are removed including removing side covers of condenser and cleaning the copper tubes by means of nylon brushes till the complete scaling is removed and refixing of covers including replacement of rubber gasket and refixing pipe connection etc. all as specified and directed to complete satisfaction of Engineer-in-charge. |
| 36 | M&L for descaling of complete copper condenser pipe of central AC Plant water cooled condenser unit, (150TR x 3 Nos) Make : VOLTAS. circulating suitable descaling compound / solution in--to the tube with pump, and running the pump continuously till all the scale from tube are removed including removing side covers of condenser and cleaning the copper tubes by means of nylon brushes till the complete scaling is removed and refixing of covers including replacement of rubber gasket and refixing pipe connection etc. all as specified and directed to complete satisfaction of Engineer-in-charge. |
| 37 | M&L for descaling/condenser coil cleaning of complete copper condenser pipe of central AC Plant Air cooled condenser unit, (45.5TR x 3 Nos) Make : Blue Star. circulating suitable descaling compound / solution in--to the tube with pump, and running the pump continuously till all the scale from tube are removed including removing side covers of condenser and cleaning the copper tubes by means of nylon brushes till the complete scaling is removed and refixing of covers including replacement of rubber gasket and refixing pipe connection etc. all as specified and directed to complete satisfaction of Engineer-in-charge. |
| 38 | M&L for descaling/condenser coil cleaning of complete copper condenser pipe of central AC Plant Air cooled condenser unit, (50TR x 3 Nos) Make : Blue Star. circulating suitable descaling compound / solution in--to the tube with pump, and running the pump continuously till all the scale from tube are removed including removing side covers of condenser and cleaning the copper tubes by means of nylon brushes till the complete scaling is removed and refixing of covers including replacement of rubber gasket and refixing pipe connection etc. all as specified and directed to complete satisfaction of Engineer-in-charge. |
| 39 | Note for Ser No 13 to 19. (i) Descaling / Preventive maintenance including servicing chiller unit shall be carried out two times during contract period and shall be measured two times. (ii) Contractor shall also be responsibile to rectify any defect/complaint lodged by user and maintain plant in running condition within 24 Hours during break down without any extra cost during contract period. |
| 40 | Comprehensive / Preventive maintenance of following capacity AHU as per manufacturer standard check list and detailed as under all as directed by Engineer-in-Charge and comprising of following Jobs:- .(a) Testing / Checking & servicing of blower fan motor and rectification of minor defect if any.(b) Testing / Checking of blower fan blade for proper functioning.(c) Cleaning of cooling coil of AHU unit with pressurised water and then testing/ checking of Cooling coil for leakage and rectification of leakage by brazing including.(d) Testing / Checking of all electrical connection and control wiring tighting of electrical connection and rectification of minor defect if any complete.(e) Testing / Checking and Cleaning the moisture drain pipe.(f) Cleaning of entire AHU unit for removing all dirt dust, grease etc (g) Contractor shall also be responsibile to rectify any defect/complaint lodged by user and maintain plant in running condition within 24 Hours during break down without any extra cost during contract period Note :- contrator will carried out comprehensive/preventive maintenance of AHU two time during contract period and shall be measured two times, as directed by Engineer -in-charge as per requirement . |
| 41 | AHU unit 14500 CFM capacity, Make -Zeco Aircon Ltd (Plant Capacity 102 TR) |
| 42 | AHU unit 4500 CFM capacity, Make -Zeco Aircon Ltd (Plant capacity 44 TR) |
| 43 | AHU unit 5500 CFM capacity, Make -Zeco Aircon Ltd (Plant Capacity 44 TR) |
| 44 | AHU unit 27700 CFM capacity, Make -Zeco Aircon Ltd (Plant capacity 60 TR) |
| 45 | AHU unit 60 TR 24300 CFM capacity , Make Zeco Aircon Ltd (Plant capacity 120TR) |
| 46 | AHU unit 60 TR 20200 CFM capacity , Make Zeco Aircon Ltd (Plant capacity 120TR) |
| 47 | AHU unit 60 TR 12600 CFM capacity , Make Zeco Aircon Ltd (Plant capacity 120TR) |
| 48 | AHU unit 150 TR 28000 CFM capacity , Make Zeco Aircon Ltd (Plant capacity 300TR) |
| 49 | AHU unit 45.5 TR 14000 CFM capacity , Make Edge Tech (Plant capacity 91TR) |
| 50 | AHU unit 45.5 TR 15700 CFM capacity , Make Edge Tech (Plant capacity 91TR) |
| 51 | Comprehensive / Preventive maintenance of following capacity industrial dehumidifier shall be carried out as per manufacturer standard check list and detailed as under all as directed by Engineer-in-Charge and comprising of following Jobs:-.(a) Testing / Checking of \\"Ecordy\\" desicant honeycomb rotor/bed mounted on a horizontal fixed shaft arrangement and rectification of minor defect if any.(b) Testing / Checking of all electrical connection and control wiring tighting of electrical connection and rectification of minor defect if any complete.(c) Cleaning of inlet pre filter EU-4 synthetic non woven media filter with pressurised water. (d) Testing / checking of serviceability of Thermostat and rectification of minor defect if any.(e) Testing / Checking of Electrical heater bank or steam coil with electric heater for steam reactivation and rectification of minor defect if any complete.(f) Testing / Checking of Regeneration fan motor and rectification of minor defect if any complete.(g) Cleaning of entire unit for removing all dirt dust, grease etc (h) Contractor shall also be responsibile to rectify any defect/complaint lodged by user and maintain plant in running condition within 24 Hours during break down without any extra cost during contract period Preventive maintenance including servicing of dehumidifier shall be carried out two times during contract period, and shall be measured two times, |
| 52 | Dehumifier unit 3000 CMH capacity, Make- Bry Air |
| 53 | Dehumifier unit 1500 CMH capacity, Make- Bry Air |
| 54 | Hot water Generator 63 KW capacity Make Rapid Cool |
| 55 | Supply and fixing in repair/replacement master controller card (PCB) suitable for outdoor unit Dehumidifier of capacity upto 3000 CMH. Model F113000 |
| 56 | supply and fixing only in repair/replacement 'V' belts of size A-24/27 of blower motor of AC plant any type all as directed by the Engineer-in-Charge.Make : Fenner / Dunlop / JK. |
| 57 | supply and fixing in repair/replacement 'V' belts of size A-34/38 of AHU motor of AC plant any type all as directed by the Engineer-in-Charge.Make : Fenner / Dunlop / JK. |
| 58 | supply and fixing in repair/replacement 'V' belts of size B-56/60/86/89 of AHU motor of AC plant any type all as directed by the Engineer-in-Charge.Make : Fenner / Dunlop / JK. |
| 59 | supply and fixing in repair/replacement 'V' belts of size B-100/112 of AHU motor of AC plant any type all as directed by the Engineer-in-Charge.Make : Fenner / Dunlop / JK. |
| 60 | supply and fixing in repair/replacement Oil/HP/LP pressure sensor Probe suitable for reciprocating Chiller unit of 30 TR central AC plant all as directed by the Engineer-in-Charge.Make:- Voltas Model : 09066 or equivalent make approved by The GE. |
| 61 | supply and fixing in repair/replacement water flow switch suitable for central type AC plant of any capacity all as directed by the Engineer-in-Charge.Make : INDFOSS / DANFOSS/ HONEYWELL. |
| 62 | supply and fixing in repair/replacement water differential pressure cut out switch MP-55 for compressor of central type AC plant of any capacity all as directed by the Engineer-in-Charge.Make : INDFOSS / DANFOSS/ HONEYWELL. |
| 63 | supply and fixing in repair/replacement Single phase preventer relay for precision Air condition unit Make :- Minilec , Model No :- S2 VMR 6 or equivalent of make L&T / BHARATIA CUTTLER HAMMER / C&S |
| 64 | supply and fixing in repair/replacement compressor over load protection type 3RP15761NP30 , starting time range 3-60 sec rated voltage :- 200-240V, 50HZ including connecting complete.Make:- SIEMENS / L&T / BHARATIA CUTTLER HAMMER / C&S |
| 65 | supply and fixing in repair/replacement Blower timer type Micron Electronic Timer , including connecting complete.Make:- SIEMENS - Cat No :- 20SDTO or L&T / BHARATIA CUTTLER HAMMER / C&S |
| 66 | supply and fixing in repair/replacement Blower over load protection type MN-2 SS01212 , rated voltage :- 200-500V, 50HZ, 2A ,AC-15, Maximum fuse 6A including connecting complete.Make:- SIEMENS / L&T / BHARATIA CUTTLER HAMMER / C&S |
| 67 | supply and fixing in repair/replacement 3 pole power contactor 25 A, 415 V, coil voltage 230 V including connecting complete all as specified & directed by Engg-in-charge.Make:- L&T type MNX 25 or equivalent of make SIEMENS / / BHARATIA CUTTLER HAMMER / C&S |
| 68 | supply and fixing in repair/replacement 4 pole power contactor 18 A, 415 V, coil voltage 230 V including connecting complete all as specified & directed by Engg-in-charge.Make:- L&T type MCX 01 or equivalent of make SIEMENS / / BHARATIA CUTTLER HAMMER / C&S |
| 69 | supply and fixing in repair/replacement 3 pole power contactor 12 A, 415 V, coil voltage 230 V including connecting complete all as specified & directed by Engg-in-charge.Make:- L&T type MNX 12 or equivalent of make SIEMENS / / BHARATIA CUTTLER HAMMER / C&S |
| 70 | Supply & fixing in repair/replacement 3 pole power contactor 32 A, 415 V, coil voltage 230 V including connecting complete.Make:- L&T type MNX 32 or equivalent of make SIEMENS / / BHARATIA CUTTLER HAMMER / C&S |
| 71 | Supply & fixing in repair/replacement 3 pole power contactor 45 A, 415 V, coil voltage 230 V with including connecting complete.Make SIEMENS type 3TF4602-0A or equivalent of make L&T / BHARATIA CUTTLER HAMMER / C&S |
| 72 | Supply & fixing in repair/replacement (PCB Card ) suitable for 01 x 26 TR Capacity AC Plant of Make Blue Star Model No XAC 25024 MAR 2 |
| 73 | Supply & fixing Battery 12 V 1.2 AH suitale for Package type AC Plant of capacity 3 TR |
| 74 | Supply & fixing in repair/replacement MCB 40 Amp, Three Pole, breaking capacity 25 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed by Engr in charge. |
| 75 | Supply & fixing in repair/replacement MCCB 125 Amp, Four Pole, breaking capacity 36 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed. |
| 76 | Supply & fixing in repair/replacement MCCB 160 Amp, Four Pole, breaking capacity 36 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed. |
| 77 | Supply & fixing in repair/replacement MCCB 250 Amp, Four Pole, breaking capacity 36 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed. |
| 78 | Supply and fixing in repair/replacement MCB 32 Amp 3 Pole , 415 Volt 10 KA C Curve complete all as specified and as directed. |
| 79 | M&L for taking out Pump along with motor of capacity 11 KW /15 HP from central type AC plant, opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding wire of suitable size including insulating materials, varnishing, drying, replacement of both driven end non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed |
| 80 | M&L for taking out Motor & pump of 7.5 KW/ 10 HP cap , Dismantling the motor with disconnecting the same from the compressor and remove rubber coupling and its connected accessories and transporting to reputed work shop for rewinding . opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of suitable size including insulating materials, varnishing, drying, replacement of both driven end non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed |
| 81 | M&L for taking out AHU blower Motor 13 KW to 15 KW/ 17.5 HP to 20 HP cap , Dismantling the motor with disconnecting the same from the compressor and remove rubber coupling and its connected accessories and transporting to reputed work shop for rewinding . opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of suitable size including insulating materials, varnishing, drying, replacement of both driven end non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed |
| 82 | M&L for taking out AHU blower Motor 18.5 KW to 22 KW/25 HP to 30 HP cap , Dismantling the motor with disconnecting the same from the compressor and remove rubber coupling and its connected accessories and transporting to reputed work shop for rewinding . opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of suitable size including insulating materials, varnishing, drying, replacement of both driven end non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed |
| 83 | M&L for taking out AHU blower Motor 3.5 KW/5 HP cap , dismantling the motor with disconnecting the same from the compressor and remove rubber coupling and its connected accessories and transporting to reputed work shop for rewinding . opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of suitable size including insulating materials, varnishing, drying, replacement of both driven end non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed |
| 84 | Comprehensive / Preventive maintenance of Pre Package Air conditioning of fallowing capacities, maintenece shall be carried out as per manufacturer standard check list and all as directed by Engineer-in-Charge and comprising of following Jobs :-.(a) Cleaning the evaporator coil of indoor unit with pressureized water then apply one coat of descaling solution and clean with nylon brush and then testing/ checking of evaporator coil for leakage and rectification of leakage by brazing including.. (b) Cleaning of condensing coil of outdoor unit with pressurised water and then testing/ checking of Cooling coil for leakage and rectification of leakage by brazing including. |
| 85 | (c) Testing / Checking and Cleaning of Air filter.(d) Testing / Checking of compressor for its proper functioning and rectification of minor defect if any.(e) Testing / Checking & servicing of blower fan motor and rectification of minor defect if any.(f) Testing / Checking & servicing of condenser fan motor and rectification of minor defect if any.(g) Testing / Checking of control switch such as pressure cut outs, refrigerent flow switch, temprature sensore for proper functioning.(h) Testing / Checking of refrigerant pipe for leakage and Rectification of leakage by brazing including cleaning of refrigerant pipe.(j) Testing / Checking of all electrical connection and control wiring tighting of electrical connection and rectification of minor defect if any complete. |
| 86 | NOTE :-(i) Charging of gas, if required, shall be measured and paid for separately under appropriate item. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item. (ii) After completion of Comprehensive / Preventive maintenance including servicing of Precision type Package AC unit shall be tested by the contractor all as directed by the Engineer-in-Charge.(iii) Comprehensive / Preventive maintenance including servicing of Package unit shall be carried out two times during contract period and shall be measured two times. Spare Parts shall be paid under respective items. Cost of replacement of any spare parts pertains to Package type air conditioning unit are deemed to be included in the quoted rate through out the contract period. (iv) Contractor shall also be responsibile to rectify any defect/complaint lodged by user and maintain plant in running condition within 24 Hours during break down without any extra cost during contract period. |
| 87 | Precision type Package Air conditioning unit (Make: Emerson, Model: PEX-135 EC I-COM) of Capacity 10 TR complete all as specified and as directed. |
| 88 | Precision type Package Air conditioning unit (Make: Emersion, Model: PEC113 RA/DA with I Com) of Capacity 3.0 TR complete all as specified and as directed. |
| 89 | Precision type Package Air conditioning unit (Make: Emersion, Model: PEX130 RA/DA with I Com) of Capacity 7.5 TR complete all as specified and as directed. |
| 90 | Precision type Package Air conditioning unit (Make: FLAKT GROUP, Model: DMOUCD075A with I Com) of Capacity 16 TR complete all as specified and as directed. |
| 91 | Package type Air conditioning unit (Make: Blue Star , Model: DPA 1321R3Q of Capacity 11 TR complete all as specified and as directed. |
| 92 | Spare parts for maintenance of Precision type Package Air conditioning as under including testing on load complete all as specified and as directed. |
| 93 | NOTE :-(i) Charging of gas, if required, shall be measured and paid for separately under appropriate item. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item. (ii) After completion of Comprehensive / Preventive maintenance including servicing of Precision type Package AC unit shall be tested by the contractor all as directed by the Engineer-in-Charge.(iii) Comprehensive / Preventive maintenance including servicing of Package unit shall be carried out two times during contract period and shall be measured two times. Spare Parts shall be paid under respective items. Cost of replacement of any spare parts pertains to Package type air conditioning unit are deemed to be included in the quoted rate through out the contract period. (iv) Contractor shall also be responsibile to rectify any defect/complaint lodged by user and maintain plant in running condition within 24 Hours during break down without any extra cost during contract period. |
| 94 | Supply only Evaporator centrifugal blower motor with rotor of same size and capacity of Precision type Package Air conditioning complete all as specified and as directed. |
| 95 | Supply only condenser fan motor with blade of same size and capacity of Precision type Package Air conditioning complete all as specified and as directed. |
| 96 | Supply only LP/HP cutout for compressor of Precision type Package Air conditioning complete all as specified and as directed. |
| 97 | Supply only filter liquid drier for compressor of Precision type Package Air conditioning of any size and capacity complete all as specified and as directed. |
| 98 | Supply only Micro-processor Controller (I Com) (PCB Card )of Precision type Package Air conditioning. Upto 10 TR Capacity all as specified and as directed by Engr-in-charge |
| 99 | Supply only Expansion Valve for compressor of precision Air conditioning unit complete all as specified and directed.Make Emersion |
| 100 | Supply only Air sensor for compressor of precision Air conditioning unit all as specified and directed. Make Emersion |
| 101 | Supply only Printed Circuit Board of Precision type Package Air conditioning of capacity 33000 kcal/Hr unit all as specified and directed. Make: BlueStar |
| 102 | Supply only Condenser fan motor (outdoor unit) with blade of Precision type Package Air conditioning of capacity 33000 kcal/Hr unit all as specified and directed. Make: BlueStar |
| 103 | Supply only of water Inlet and outlet temp sensor suitable for Central AC Plant upto 150 TR alongwith wire complate all as specified and as directed. |
| 104 | Supply and fixing pre filter cartaige suitable for RO Plant of capacity 1000 ltr /hr complete all as specified and as directed. |
| 105 | Supply & fix in repair/replacement hermetically sealed Scroll Compressor with base frame & electric phase reversal protection of capacity 7.5 TR of Precision type Package Air conditioning (Make: Emerson, Model: PEC130 RA/DA with I Com) comprising fallowing job:-(i) Charging of nitrogen gas in unit & complete system at 300 psi pressure and checking of any dropping of pressure/ leakage upto 72 Hrs after replacement of compressor & rectification of leakage if any.(ii) Vaccumisation of complete system for minimum 2 days for dropping of vacuum pressure & rectification of leakage if any.(iii) Charging of complete system with R-407 gas for maitaining the system pressure upto HP-175 psi & LP-65 psi(iv) Measure the inlet and outlet temperature of package unit.(v) Testing and commisioning of compressor after completion.Make: Teccumesh /Emerson Copeland |
| 106 | supply & fix in repair/replacement hermetically sealed Scroll Compressor with base frame & electric phase reversal protection of capacity 03 TR of Precision type Package Air conditioning (Make: Emersion, Model: PEC113 RA/DA with I Com) comprising fallowing job:-(i) Charging of nitrogen gas in unit & complete system at 300 psi pressure and checking of any dropping of pressure/ leakage upto 72 Hrs after replacement of compressor & rectification of leakage if any.(ii) Vaccumisation of complete system for minimum 2 days for dropping of vaccume pressure & rectification of leakage if any.(iii) Charging of complete system with suitable gas for maitaining the system pressure upto HP-175 psi & LP-65 psi(iv) Measure the inlet and outlet temperature of package unit.(v) Testing and commisioning of compressor after completion.Make: Godrej/Teccumesh /Emerson copland |
| 107 | Supply and toping up refrigerant gas R-22 to the central / package AC plant of any capacity system all as directed by the Engineer in charge. |
| 108 | Supply and toping up refrigerant gas R-410 A to the central / package AC plant of any capacity system all as directed by the Engineer in charge. |
| 109 | Supply and toping up refrigerant gas R-407 C to the central / package AC plant of any capacity system all as directed by the Engineer in charge. |
| 110 | Note for Item Ser No 55 to 58 : Cost of necessary tools and plant/technician for toping up of refrigerant are deemed to be included in the quoted rate. |
| 111 | Supply and fixing in repair/replacement main electronic circuit control board of Central type AC plant (MAKE : BLUE STAR Model No :XAC5S060MAR2) of capacity 50 TR including connecting completea all as directed by Engg-in-charge.NOTE :- Make as per manufacturer recommendation after written approval by The GE. |
| 112 | Supply and fixing in repair/replacement of scroll type compressor suitable for Precision type Package Air conditioning of capacity 33000 kcal/Hr unit , make Bluestar all as specified and directed by Engg -in-charge. |
| 113 | Supply and fixing in repair/replacement of display unit suitable for chiller unit upto 50 TR capacity make Blue star complete inlcuding connecting wire all as specified and as directed by Engr-in-charge |
| 114 | Supply and fixing in repair/replacement MVPD 30 - 220 Amp , Model - EC Aux Supply - 230VAC complete all as specified and as directed by Engr in Charge |
| 115 | Supply and fixing in repair/replacement controller box with display (Model No VLRP Single V4) , Type Delux , Range 6/5/4, Aux supply 13 VAC suitable for 60 TR water cooled central AC Plant complete all as specified and as directed by Engr-in-charge |
| 116 | Supply and fixing in repair/replacement of connector of capacity suitable for 10 sqmm cable complete all as specified and as directed by Engr -in- Charge |
| 117 | Supply and fixing in repair/replacement of connector of capacity suitable for 16 sqmm cable to 50 sqmm cable upto 100 Amp complete all as specified and as directed by Engr -in- Charge |
| 118 | M&L for Painting of complete water cooled central AC Plant (comprising 3 Nos chiller unit of capacity 193536 K Cal/Hr, pipe lines, valves, pump sets (04 Nos), steel surface, AHU pipe lines and chiller pipes etc) by preparation of old painted surface removing of dirt / dust / oil grease etc and applying two coat of synthetic enamel paint of shade as directed by Engr-in-charge . |
| 119 | M&L for Painting of complete Air cooled central AC Plant of capacity 102 TR (comprising 4 Nos chiller unit of capacity 34 TR, pipe lines, valves, pump sets (04 Nos), steel surface, AHU pipe lines and chiller pipes etc) by preparation of old painted surface removing of dirt / dust / oil grease etc and applying two coat of synthetic enamel paint of shade as directed by Engr-in-charge . |
| 120 | M&L for Painting of complete Air cooled central AC Plant of capacity 52 TR (comprising 3 Nos chiller unit of capacity 26 TR, pipe lines, valves, pump sets (03 Nos), steel surface, AHU pipe lines and chiller pipes etc) by preparation of old painted surface removing of dirt / dust / oil grease etc and applying two coat of synthetic enamel paint of shade as directed by Engr-in-charge . |
| 121 | M&L for Painting of complete water cooled central AC Plant of capacity 60 TR (comprising 3 Nos unit of capacity 30 TR, pipe lines, valves, pump sets, cooling tower steel surface, AHU pipe lines and chiller pipes etc) by preparation of old painted surface removing of dirt / dust / oil grease etc and applying two coat of synthetic enamel paint of shade as directed by Engr-in-charge . |
| 122 | M&L for Painting of complete Air Cooled central AC Plant of capacity 100 TR (comprising 3 Nos Chiller unit of capacity 50 TR each, pipe lines, valves, pump sets, AHU pipe lines and chiller pipes etc) by preparation of old painted surface removing of dirt / dust / oil grease etc and applying two coat of synthetic enamel paint of shade as directed by Engr-in-charge . |
| 123 | M&L for Painting of complete Air Cooled central AC Plant of capacity 91 TR (comprising 3 Nos Chiller unit of capacity 45.5 TR, pipe lines, valves, pump sets, AHU pipe lines and chiller pipes etc) by preparation of old painted surface removing of dirt / dust / oil grease etc and applying two coat of synthetic enamel paint of shade as directed by Engr-in-charge . |
| 124 | M&L for Painting of complete Water Cooled central AC Plant of capacity 300 TR (comprising 3 Nos chiller unit of capacity 150 TR, pipe lines, valves, pump sets- 06 Nos, AHU pipe lines and chiller pipes , cooling tower - 03 Nos etc) by preparation of old painted surface removing of dirt / dust / oil grease etc and applying two coat of synthetic enamel paint of shade as directed by Engr-in-charge . |
| 125 | S&F in repair 100mm dial type pressure guage with approximate range (0-11kgs) and SS valve and SS Tubing all as directed by Engr-in Charge |
| 126 | S&F in repair 100mm dial type Tempreture guage with approximate range and SS valve and SS Tubing all as directed by Engr-in Charge |
| 127 | S&F in repair/replacement of gate valve 20mm dia complete all as specified and as directed by Engr-in-charge |
| 128 | M&L for repair/replacement of Display PCB card suitable for chiller unit 150 TR (Make Voltas) complete all as specified and as directed by Engr-in-charge |
| 129 | M&L for repair/replacement of Master controller PCB card suitable for chiller unit 150 TR (Make Voltas) complete all as specified and as directed by Engr-in-charge |
| 130 | M&L for repair of leakage of cooling tower from bottom side by applying suitable solution/compound and arresting leakage of capacity 300 TR Central AC Plant complate all as specified and as directed by Engr-in-charge |
| 131 | Supply , installation, testing and commissioning of PN 16 Butterfly valves of 150mm dia (MS Pipe) duly insulated with companion flanges, nuts, bolts, gaskets etc as specified , Butterfly valves with cast iron body, seat of black nitrite rubber, nylon coated SG iron disc PTFE coated SS (AISI 410) shaft etc as required . These valve shall conforming to BS 5155, MSS SP 67 & API 609 and shall be desiged to fit without gasket between mating flanges. The valves shall be suitable for flow in either direction and seal in both direction . |
| 132 | Supply , installation, testing and commissioning of PN 16 Butterfly valves of 80mm dia (MS Pipe) duly insulated with companion flanges, nuts, bolts, gaskets etc as specified , Butterfly valves with cast iron body, seat of black nitrite rubber, nylon coated SG iron disc PTFE coated SS (AISI 410) shaft etc as required . These valve shall conforming to BS 5155, MSS SP 67 & API 609 and shall be desiged to fit without gasket between mating flanges. The valves shall be suitable for flow in either direction and seal in both direction . |
| 133 | Supply and fixing in repair/replacement of 25mm thick nitrile rubber insulation with aluminium foil complete including taking down of old u/s insulation all as specified and as directed by Engr -in-charge |
| 134 | Supply and fixing of aluminium cladding 26 gauge to cover AC Duct complete with fixing by machine, screw all as speicified and as directed by Engr-in-charge |
| 135 | Supply and fixing Power contractor AC 3 Rating 140Amp 415 V with 2 NO + NC, 50 Hz 3 Phase complete all as specified and as directed by Engr-in-charge. Make Seimen |
| 136 | Supply and fixing Control Panel suitable for AHU 8000 CFM, 25 TR complete including all items i.e contactor, relays, MCBs , connector etc as per existing techical specification all as specified and as directed by Engr-in-charge. Make:- Powersafe control System Pvt Ltd |
| 137 | Supply, fixing, testing and commissioing of mild steel chilled water pipe of class 'C' heavy duty conforming to IS : 1239 (part I) 1991 and IS : 3589 to 1991 grade 330 of size 200 mm dia thickness 5.40 mm, cut to reqd length, and installed with welded joints, including all necessary fittings such as elbows, tees, bends, reducers, flanged, supports, Air purge, valves, drain valve etc. duly insulated and as per specification 50mm thick TF quality EPS pipe section insulation of 18 Kg/ cum density and covered with 28 gauge aluminium sheet clading and as per specification including taking down existing pipes complete all as specified and as directed. Make : TATA/Jindal/Zenith / Surya Prakash |
| 138 | Supply, fixing, testing and commissioning of mild steel chilled water pipe of class 'C' heavy duty conforming to IS : 1239 (part I) 1991 and IS : 3589 to 1991 grade 330 of size 150 mm dia thickness 5.40mm, cut to reqd length, and installed with welded joints, including all necessary fittings such as elbows, tees, bends, reducers, flanged, supports, Air purge, valves, drain valve etc. duly insulated and as per specification 50mm thick TF quality EPS pipe section insulation of 18 Kg/ cum density and covered with 28 gauge aluminium sheet clading and as per specification & including taking down existing pipes complete all as specified and as directed. Make : TATA/Jindal/Zenith / Surya Prakash |
| 139 | Supply & fixing in repair/replacement of Pre filter type E4 4/5 suitable for AHU unit box type with aluminmium extruded section frame and body and efficiency 90% down to 10 micron particle of following size complete all as specified and directed :- |
| 140 | Size of filter 610 x 610 x 50mm |
| 141 | Size of filter 610 x 305 x 50mm |
| 142 | Size of filter 305 x 305 x 50mm |
| 143 | Size of filter 460 x 510 x 50mm Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysDec 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 28 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender