Housing Urban and Rular Development Government Departments Closing in 14 days TDR #58518646

Tender For Re-Electrification Work Of The Old Building Of Government Girls Inter College Indira Nagar Lucknow

Issued by Government Departments · Lucknow, Uttar Pradesh
Tender Value
18.13 Lakhs
Estimated cost
Bid Submission
27 Nov 2026
14 days left
EMD
1.82 Lakhs
Bank guarantee accepted
Document Fee
854
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Re-Electrification Work Of The Old Building Of Government Girls Inter College Indira Nagar Lucknow

BOQ

Name of Work:- Rajkiya Balika Inter College Indira Nagar Lucknow ke purane bhawan ka punah vidhutikaran ka karya
Sl. No. Item Description
1Wiring for light point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required.
2Wiring for Twin Control light point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required.
3Wiring for Fan point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required.
4Wiring for Call bell Point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required.
5Wiring for Exhaust fan with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required.
6Wiring for Plug with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required.
7Wiring for circuit/ Submain wiring alongwith earth wire with the following sizes of KRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit as required.
82 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
92 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
102 X 4 sq. mm + 1 X 4 sq. mm earth wire
112 X 6 sq. mm + 1 X 6 sq. mm earth wire
122 X16 sq. mm + 1 X 6 sq. mm earth wire
13Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
14Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
15S/F of 12 way SPN DB with additional metallic Double door without MCB Cat-A
16S/F of 4 way TPN DB with additional metallic Double door without MCB Cat-A
17Supply and fixing of call bell of approved make on polished MDFEG/ Teak ply board Complete all respect.
18Installation of exhaust/fresh air fan in the existing opening including making good the damage connection testing commissioning etc as required.
19Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.
20S/F of 6 to 32 Amp SP MCB
21S/L & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB ''C'' curve including connections, etc. as required. For A.C
22Providing and laying G.I Strip 32mm x 6mm from earth electrode directly in ground as required.
23S/F of Brass Compression gland & Aluminum Lugs
2470sqmm 3-1/2 core
2525sqmm 3-1/2 core
2635sqmm 3-1/2 core
27S/F of 16 SWG MS drum with Luvers duly painted including marking hole in the wall for fresh air/exhaust fan and finishing properly complete in all respect.
28Supplying and fixing of following rating, DP MCB (10KA) C series MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2940 Amp DP MCB
3032 Amp DP MCB
31Supplying and fixing following rating, Four pole (Three phase and neutral) 415 V, residual current circuit breaker (RCCB) having a sensitivity current 30 A in the existing MCB DB complete with connections, testing and commissioning etc. as required.
3225 Amp 4P RCCB
3363 Amp 4P RCCB
34Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation. B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS: 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 °C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
35S/F LED Bulb 9 Watt
36Supply of Exhaust Fan/Fresh air fan 300mm Sweep 900/1400 RPM
37Supply and Laying of Aluminum conductor PVC insulated armored served sheathed cables 1100V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top On surface the cable run shall be fixed on M.S clamps etc of suitable sixe or as directed by Engineer in charge complete in all respect including exaction and refilling. The armoring of the cable shall be properly connected with the earth conductor by clamps etc.
3870sqmm 3-1/2 core
3935sqmm 3-1/2 core
4025sqmm 3-1/2 core
41Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI ≥80, Flicker free, (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 Im/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.
42(Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) 18 -22 Watt
43Supply Installation Testing and Commissing of LT Panel vermin proof floor mounting M.S channel base with botton and Fabricated out of 2.0/1.6mm thick CRCA sheet steel painted with powder coated paint of shade as per the direction of Engineer In-Charge after proper sheet treatment process of sheet steel/ The bus bar of panel shall be of Electrical grade High conductive Aluminum alloy of appropriate cross section as per rating. The main bus bar shall rum throughout to panel of rating as main incomer rating Thae bus bar shall be supproted by non hygroscopic SMC/DMC bus bar supports which shall be mounted on proper interval to ensure the bear the jerks of short circuit of 50ka for panels having ACB as incomer & 36KA for panels having MCCB Incommers. Panel shall be constructed in fully segregated Compartment Design for Each Feeder as per 3b construction Format. The Panel shall be completed in all respect as per IS:8623 Part-2&3. There shall be separate Metering Compartment for incemer metering and outgoing metering. Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel - Cat B,Incoming -125Amp MCCB-1 No, Outgoing-63Amp MCCB -1Nos Outgoing-32Amp MCCB -3 Nos
44Supply and fixing of LED Street light Fitting with mandatory driver set having dia cast aluminium body with toughend glass/ UV stabuirzed PC Cover and lenses sotable for 75 Watt to 90 Watt and Continning to IP 66, and Ik07 and above protection having Company LOGO Engraved complete in ali respect including Labour 2000-10800 System lumens, High Power LED with lenses 120 Lm/W, PF>0 95, THD <10% at full load, CRI >70., Potted driver Set in Metal housing (Not Circustory) Phase to phase Protection at 440V & >300V auto cut and re-start feature with 5 years warrantee
45GST @ 18% Extra Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58518646
AUTHORITY Government Departments
TENDER VALUE 18.13 Lakhs
LAST DATE 27-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Re-Electrification Work Of The Old Building Of Government Girls Inter College Indira Nagar Lucknow
Basic Detail
Tender No 2618/4CBW-17EM/2026 Date 30-10-2026
Bidding Type Tender
Location
City Lucknow
State Uttar Pradesh
Key Dates
Publish Date 13 Nov 2026
Submission Date 27 Nov 2026
Open Date 27 Nov 2026
Finance
Tender Value 18.13 Lakhs
Tender Fee 854
EMD 1.82 Lakhs
Exemption Not Available
Document List
86ce7e12-04f2-42ed-993a-276b7d497357.html
BOQ_2291820.xls
T1IndiraNagar2618.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 13, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Nov 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Nov 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

86ce7e12-04f2-42ed-993a-276b7d497357.html

xls

BOQ_2291820.xls

pdf

T1IndiraNagar2618.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender