Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #58518444

Tender For Misc E/M Wks And Repair/Replacement/Maint Of Lt Electrical Distribution System And Other Connected Items At Afmc And Allied Area Under Ge (Cental) Pune

Issued by Statutory Bodies & Commissions/Committees · Pune, Maharashtra
Tender Value
33.48 Lakhs
Estimated cost
Bid Submission
04 Dec 2026
19 days left
EMD
66960
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Misc E/M Wks And Repair/Replacement/Maint Of Lt Electrical Distribution System And Other Connected Items At Afmc And Allied Area Under Ge (Cental) Pune

BOQ

Name of Work:- Misc E/M Wks and Repair/Replacement/Maint of LT Electrical distribution system and other connected items at AFMC and allied area under GE (Cental) Pune
Sl. No. Item Description
1Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of LT UG cable in soft/loose and getting out complete all as specified and directed.
2All as per srl item No 01 above but exc 1.5 mtr but not exc 3.00 mtr depth complete all as specified and directed.
3Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm as in soil complete all as specified and directed.
4Removing excavated material to a distance n.exc 50m and depositing where directed at level not exceeding 1.5m above the starting point complete all as specified and directed.
5M&L for reinforced concrete pipes of dia 150 mm 2 nos half round (each of 1 RM long for bottom and top) and before laying excavated area shall be levelled complete all as specified and directed.
6M&L for GI Tubes, 'light grade', galvanised, with all fittings laid in trenches of size 50 mm dia complete all as specified and directed.
7M&L for GI Tubes, 'light grade', galvanised, with all fittings laid in trenches of size 80 mm dia complete all as specified and directed.
8Cutting of road/hard standing and making good with PCC (1:2:4) type B 1 using 20mm graded stone aggregate complete all as specified and directed.
9M&L for fixing of Orange electrical conduit underground HDPE/DWC pipe of size 76 mm dia including all necessary clamping and fixing arrangement complete all as specified and directed.
10Taking out existing worn out/old cable any type and make (for item No 23 and 24 below) for cable size 185/240 sqmm size of 1100 Volt grade in pieces from trenches making loop for transportation and removal from site after taking proper shut down from MES competant staff complete all as specified and directed.Note: Any excavation required for the work will be measured and paid separately under relevant Items of CA.
11Taking out existing worn out/old cable any type and make (for item No 19 to 22 below) for cable size 70/95/120/150 sqmm of 1100 Volt grade in pieces from trenches making loop for transportation and removal from site after taking proper shut down from MES competant staff complete all as specified and directed.Note: Any excavation required for the work will be measured and paid separately under relevant Items of CA complete all as specified and directed.
12Taking out existing worn out/old cable any type and make (for item No 13 to 18 and 25 below) for cable size 4/10/16/25/35/50 sqmm any type of 1100 Volt grade in pieces from trenches making loop for transportation and removal from site after taking proper shut down from MES competant staff complete all as specified and directed.Note: Any excavation required for the work will be measured and paid separately under relevant Items of CA complete all as specified and directed.
13Maint and augmentation by supply, laying, testing and commissionnig of 10 sqmm 2 core LT cables 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised Steel strip or wire armoured with multi stranded aluminum conductor, ISI marked, heavy duty including cable glands, cable lugs in LT panel/MDB in building etc to suit the cable including material and labour for all jointing/connecting material as required size, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall complete all as specified and directed. Note: Excavation, Returing and filling and disposal will be paid seperately under relevant Items of CA.
14All as per srl item no 13 above but of size 16 sq mm 2 core
15All as per srl item no 13 above but of size 16 sq mm 4 core
16All as per srl item no 13 above but of size 25 sq mm 3.5 core
17All as per srl item no 13 above but of size 35 sq mm 3.5 core
18All as per srl item no 13 above but of size 50 sq mm 3.5 core
19All as per srl item no 13 above but of size 70 sq mm 3.5 core
20All as per srl item no 13 above but of size 95 sq mm 3.5 core
21All as per srl item no 13 above but of size 120 sq mm 3.5 core
22All as per srl item no 13 above but of size 150 sq mm 3.5 core
23All as per srl item no 13 above but of size 185 sq mm 3.5 core
24All as per srl item no 13 above but of size 240 sq mm 3.5 core
25Supply, laying, testing and commissionnig of 4 sqmm 3 core LT cables 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised Steel strip or wire armoured with multi stranded aluminum conductor, ISI marked, heavy duty including cable glands, cable lugs including material and labour for all jointing/connecting material as required size, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall complete all as specified and directed.
26M&L for MCCB 63 Amps, 16 KA, TP/3 pole 415 Volts with adjustable thermal and fixed magnetic setting with cable entry arrangements incl lugs, spreader, glands etc and fixing arrangements such as fastener, nuts, bolts complete including taking down the old U/S MCCB any type and size complete all as specified and directed.
27M&L for MCCB 125 Amps, 25KA, TP/3 pole 415 Volts with adjustable thermal and fixed magnetic setting with cable entry arrangements incl lugs, spreader, glands etc and fixing arrangements such as fastener, nuts, bolts complete including taking down the old U/S MCCB any type and size complete all as specified and directed.
28M&L for MCCB 200 Amps, 25KA, TP/3 pole 415 Volts with adjustable thermal and adjustable magnetic setting with cable entry arrangements incl lugs, spreader, glands etc and fixing arrangements such as fastener, nuts, bolts complete including taking down the old U/S MCCB any type and size complete all as specified and directed.
29M&L for MCCB 160 Amps, 25KA, 4 Pole 415 Volts with adjustable thermal and fixed magnetic setting with cable entry arrangements, lugs, glands etc and fixing arrangements such as fastener, nuts, bolts complete including taking down the old U/S MCCB complete all as specified and directed.
30M&L for MCCB 250 Amps, 25KA, 4 Pole 415 Volts with adjustable thermal and adjustable magnetic setting with cable entry arrangements incl lugs, spreader, glands etc and fixing arrangements such as fastener, nuts, bolts complete including taking down the old U/S MCCB any type and complete all as specified and directed.
31M&L for MCCB 400 Amps, 36KA, 4 Pole 415 Volts with adjustable overload and adjustable shortcircuit with cable entry arrangements incl lugs, spreader, glands etc and fixing arrangements such as fastener, nuts, bolts complete including taking down the old U/S MCCB any type and complete all as specified and directed.
32M&L for MCCB 630 Amps, 50KA, 4 Pole 415 Volts with adjustable overload and adjustable shortcircuit with cable entry arrangements incl lugs, spreader, glands etc and fixing arrangements such as fastener, nuts, bolts complete including taking down the old U/S MCCB any type and complete all as specified and directed.
33M&L for trimming of branches of trees touching LT/HT electric over head line and making clear about 3 mtr in radius by climbing up tree or by providing ladder, at a height 9 mtr and above and carrying the depositing where directed not exceeding 50 mtr complete all as specified and directed. Note :-The contractor shall be solely responsible for ensuring all safety measures during execution of the job.
34M&L for removal of vegetation in and around the MES substation, 4 pole structure, 2 pole structure like grass, shurbs, small plants complete all as specified and directed. The contractor shall be solely responsible for ensuring all safety meassures during the execution of the job. The contractor shall complete the work within one (01) hour to minimize the inconvenience to the users and sufficient man power and eqpt will be provided to complete the job within the specified time frame.
35Man and material for load distribution and balancing at LT Panel/Feeder Pillar any type complete all as specified and directed., the job focuses on checking and redistributing the load at an outdoor LT feeder pillar or large panel using XLPE cables. The work include measuring of the load on each phase using a digital clamp meter and load analyzer, identify unbalanced loads or overloaded phases, redistribute load from one phase to another, disconnect and reconnect equipment or circuits from feeder pillar terminals or busbars as needed, ensure balanced load on each phase. Any insulation tape, connectors, and cable ties for securing connections use of Clamp meter, multimeter, load analyzer, and phase sequence tester use by the contractor will be the part of this job, precaution like De-energize the distribution Panel while making connections other electrical safety measures will be the reasonability of contractor. Any T&P required for the complition of job will be provided by the contractor without any extra cost. The whole job will be completed in a time bound manner complete all as directed by Engr-in-charge.
36Man and material for load distribution and balancing at Indoor DB (any type and size), the job focuses on checking and redistributing the load at all the DBs including measuring of the load on each phase using a digital clamp meter and load analyzer, identify unbalanced loads or overloaded phases, redistribute load from one phase to another, disconnect and reconnect equipment or circuits from DBs or busbars as needed, ensure balanced load on each phase. Any insulation tape, connectors, and cable ties for securing connections use of Clamp meter, multimeter, load analyzer, and phase sequence tester use by the contractor will be the part of this job, precaution like De-energize the distribution Panel while making connections other electrical safety measures will be the reasonability of contractor, The whole job will be completed in a time bound manner all as directed by Engr-in-charge.
37Material and labour for servicing and repairing LT distribution panel installed at various substation, including dismantling incomming & outgoing cable connections from feeders/switch gears, S&F heat shrinkable cable sleeves and insulation taping properly on cable. Replacement of cable end terminals (lugs) of appropriate size, replacement of U/s Nut bolts washers etc., replacing unserviceable indicator lamp R Y B, repairing to panel wiring including Panel door repair, replacement of door hinges, locking system etc. repairing/replacement of ampt meter, voltmeter, indicator lamp will be included in the job. Reconnecting all elect connections, earthing connections checking throughly and made all feeders serviceable. All electrical safety measures will be the reasonability of contractor, The whole job will be completed in a time bound manner all as directed by Engr-in-charge.
38M&L for preparing old painted surfaces by scraping and removing old paints, rust etc. from LT Panel/feeder pillar, painting in one coat of Red oxide with two coats of synthetic enamel paint complete all as specified and directed.
39M&L in repairs for cable jointing kit straight through for 1.1 KV grade cable for outdoor, heat shrink type, joint complete with jointing material and accessories suitable for 4/3.5 core XLPE, armoured, Aluminium conductor cable of following sizes complete all as specified and directed. (a) 50 Sqmm to 95 sqmm
40(b) 120 Sqmm to 185 Sqmm
41(c) 240 Sqmm to 300 Sqmm
42Taking down old UNSV panel any type and shape/size and supply, installation, testing and commissioning as in replacement of indoor type LT panel board cubical with double door, (The panel outer enclosure shall be fabricated from minimum 2.0 mm thick sheet. Equivalent higher thickness may be provided without extra cost.) floor mounted CPRI approved with MS angle Iron base frame made out of 40x40x6mm angle, with angle Iron Stand made out of 50x50x6 mm thick having 4 Nos legs of 2.5 feet height of size as required at site, grouted in PCC 1:3:6 type C-1 using 20 mm graded mechanically crushed stone aggregates for fixing panel board with and including necessary fixing arrangements, totally enclosed dust and vermin proof, front opening with locking arrangement, suitable for AC 415V, 3 phase, 50 Hz system, Red, Yellow, Blue and Black coloured insulated Aluminium bus bar of suitable size to carry 400 amps four Nos of suitable length and internal wiring with aluminum strip of suitable size duly painted internally and externally with two coats of synthetic enamel paint over a coat of Red oxide primer of any tint and marking wiring circuits, complete all as specified and directed. and as directed duly comprising of the following accessories inclusive of MCCBs Spreder, Terminals Kit, nut, bolt and washers, handle and any other assessories required for its connection and operation etc complete all as specified and directed.(a) Voltmeter flush mounted 0-400 V square digital type-01 No.(b) Ammeter flush mounted 0-400 A, CTs operated, square digital type-01 Nos.(c) Phase indicating lamp set (RYB) industrial LED type-01 Set. (d) MCCB, AC, 415 Volt, 250 Amps breaking capacity 36 kA at 415 volt, 4 pole (Adjustable Thermal & Adjustable Magnetic-01 Nos (e) MCCB, AC, 415 Volt, 63 Amps breaking capacity 25 kA at 415 volt, 4 pole (Adjustable thermal & Fixed magnetic)-04 Nos
43Supply, Errecting and fixing of true Vertical position Steel tubular swaged pole complete with coat Iron base plate, finial taper plug, bolt, nuts and screw, weld and reduced section and logitudional weld Seam through out entire length of pole including 2 coats of black bituminious paint through out intrnely and externely up to planting depth and remaining exterior portion of pole with two caot of aluminium paint over a coat of Red oxide as specified type 410 SP 31 (9.00 Mtr long) incl taking down old unserviceable pole complete all as specified and directed. Note-Excavation and Earth work and PCC in foundation shall be measured and paid separately. Please Enable Macros to View BoQ information
44Supply, Errecting and fixing of true Vertical position Steel tubular swaged pole complete with coat Iron base plate, finial taper plug, bolt, nuts and screw, weld and reduced section and logitudional weld Seam through out entire length of pole including 2 coats of black bituminious paint through out intrnely and externely up to planting depth and remaining exterior portion of pole with two caot of aluminium paint over a coat of Red oxide as specified type 410 SP 31 (9.00 Mtr long) incl taking down old unserviceable pole complete all as specified and directed. Note-Excavation and Earth work and PCC in foundation shall be measured and paid separately. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58518444
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 33.48 Lakhs
LAST DATE 04-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Misc E/M Wks And Repair/Replacement/Maint Of Lt Electrical Distribution System And Other Connected Items At Afmc And Allied Area Under Ge (Cental) Pune
Basic Detail
Tender No 8775 MISC E/M WKS AND REPAIR/REPLACEMENT/MAINT OF LT ELECTRICAL DISTRIBUTION SYSTEM AND OTHER CONNEC
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 13 Nov 2026
Submission Date 04 Dec 2026
Open Date 11 Dec 2026
Finance
Tender Value 33.48 Lakhs
Tender Fee 500
EMD 66960
Exemption Available
Document List
a98d88ce-458d-4ba8-b0ac-d7282530ca28.html
BOQ_895554.xls
TENDER8775.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Dec 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 26 days

Tender Documents

Download All (ZIP) ↓
html

a98d88ce-458d-4ba8-b0ac-d7282530ca28.html

xls

BOQ_895554.xls

pdf

TENDER8775.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender