Tender For repair maintenace Of Lwss Shantha Khad To Bodna In G.P.Chanju Tehsil Chopal Distt. Shimla (H.P). (Sh:-Replacement Of Existing Pumping Machinery Stage -1St And Repair Of Rising Main ,Rcc Fundation For Pumping Machiner And Other Allied Acces
Tender Overview
Project Description
Tender for repair maintenace Of Lwss Shantha Khad To Bodna In G.P.Chanju Tehsil Chopal Distt. Shimla (H.P). (Sh:-Replacement Of Existing Pumping Machinery Stage -1St And Repair Of Rising Main ,Rcc Fundation For Pumping Machiner And Other Allied Accessories Etc.)
BOQ
| Sl. No. | Item Description |
| 1 | Supply, erection, testing & commissioning of horizontal spindle,horizontal split casing,radial split Single, /Multistages centrifugal pumps or combination of pumps, in series/parallel of recommended make such as Mather and Platt/Kirloskar/ Model WKFI 40-16 stage conforming to BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edition to handel clear water having characteristics as mentioned in item No. 1 (A) as under, with impelleres, casting ring, priming funnel & shaft sleeves of bronze, shaft of steel with cast iron casting of suitable, capacity coupled directly throught a flexible coupling on a common base plate of cast iron casting of suitable ccapacity coupled directly through a flexible coupling on a common base plate of cast steel/ Mild steel to Kirlokar/ Crompton/ Marathon make slip ring/ squirrel cage screen protected drip proof induction electric motor of 60 HP suitable for operation on the data given below i/c the cost all accessoreis in all lead lift & carriage of material at site as per direction of Engineer-Incharge. complete with star delta starter, electric motor of 60 HP suitable for operation on the data given below i/c the cost all accessoreis in all lead lift and carriage of material at site as per direction of Engineer in charge complete with star delta starter, electrial control panel delivery side valves, suction side valves, electrical cables, common header complete H-450Meter Q4 LPS Dia of Rising main-65mm Length of Rising main:- 1400 Meter. (Pump WKFI 40/16 Moter 60 HP) |
| 2 | Laying ,jointing, with circumferential butt joints by electrical arc welding (Welding thickness shall be equal to pipe wall thickness) and testing of G.I Pipe of Jindal/Surya Roshani /Tata/AST or of approved rate contract of DGS and D / HP Govt make of following diameter confirming to IS:1239:1990 (Part-ii) (latest with up to date amendments having wall thickness as specified below capable of withstanding required test pressure , including manufacturing and fabrication of reducers taper all shorts pieces, bends etc as per site requirement made from parent tubes. The laying of pipe shall also include flanged joints duly welded in three layer (Two inner and one outer) Where ever required as per direction of Engineer in charge (Earth work in trenches and the cost of flanges I/C nut and bolts gasket will be measured and paid for separately) and all operation such as cutting welding and jointing fabrication of bends tees i.e lowering and laying in excavated trench to ensure required level including flushing cleaning and hydraulic testing complete in all respect to the entire satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The welding electrodes shall be as per IS 814 of Advani Overlikon/Over cord s/s make.The damaged portion of the pipe and all specials (if damaged during laying and jointing operation of pipe ) made from the parents tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paints over a priming coat as per AWWA specification C-203-1978. The rates also includes entire carriage of material ,flushing, Cleaning and Hydraulic testing,DP test of butt welded joints complete in all respect and to the entire satisfaction of Engineer in charge with in all leads and lifts 40mm dia. |
| 3 | Providing and fixing of Power coatedbcubical type electrical control panal 60 HP with main incomer MCCB 160 A complete in S/D Starter push botton type capacitor and internal wiring in all respect with automation compatibility etc. |
| 4 | Providing and fixing cast iron double flanged sluice valve of class II 65mm dia of leader/ Behl Kirlsker/GIED/ Kilburn/Fouress make n suction side as per the relevent IS code.C.I 65mm dia. |
| 5 | Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/of reputed make of suitable size cast iron /cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 52kg/cm^2. The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2) as per BS 1414 Class 300 ASA C.S 65 mm dia. |
| 6 | Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/of suitable size cast iron /cast steel double flanged swing check type reflux valve having bye pass arrangement & size equal to delivery of pump for withstanding nominal seat pressure of 52Kg/cm/^2 The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be cast steel conforming to class 150 ASA (Seat pressure 231Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2)) as per BSI 1414 Class 300 ASA C.S 50 mm dia. |
| 7 | Providing and fixing double flanged cast steel reflux valve of Leader/BHEL/Kilosker/Kilburn/ GLED/Fouress make and of 65mm dia for rising main having byepass arrangement for rising main andcapable withstanding the normal steel pressure as per IS 780-1984 with up to date ammendments class ASA to be mentioned by the firm.Class 300 ASA C.S 65 mm dia. |
| 8 | Supply of standard make 100mm dia circular dial pressure of suitable range Fiebeg/ Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments. |
| 9 | P/L suitable size copper PVC insulated armoured power 31/2 core P/L suitable size copper PVC insulated armoured power 31/2 core Havells/Finolex/ L&T make from meter of HPSEB to OCB & from OCB Supply side 31/2 core .3.5X35mm2 |
| 10 | P/L double loop earthing with crpper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendmentsfor above motors & other electrical equipment. |
| 11 | Excavation in foundations , trenches etc., in earth work , lift up to 1.50 metres. Stacking the eacavated soil not more than 3 metres clear from the edge of the excavation and then returning the stacked soil in 15 cm. (fifteen centimetres) layers , when required in to plinth and sides of foundations etc., conslolidating each of the disposited layer by ramming and watering and then disposing off all excavated soil as directed with in the load of 20 mtrs. Pick and Jumper work etc. complete as per the direction of the Engineer - in - Charge. |
| 12 | Providing and laying cement concrete 1:3:6 1cement:3sand: 6 graded stone aggregate 20 mm nominal size) and curing complete excluding the cost of form work in foundation and plinth. |
| 13 | Providing and laying cement concrete 1:11/2 :3 ( 1cement: 1 1/2 sand: 3graded stone aggregate 20 mm nominal size )and curing complete excluding the cost of form work and reinforcement in:- |
| 14 | foundation footing and bases of columns & like mass concrete. |
| 15 | Providing form work with steel plates 3.15mm thick so as to give fair finish I/c centering shuttering propping etc. height of propping below supporting floor to ceiling not exceeding 4mt. Height & removal of same in situ reinforce ment concrete and plain concrete work in :- |
| 16 | i) Vertical surface such as walls(any thickness) partitions and the like including attached pillasters, butteresses, plinth and string courses and the like. |
| 17 | Providing mild steel/tor steel reinforcement I/c bending binding and placing in position complete |
| 18 | Providing & Fixing of Finalax pipe( 40--100) mm dia. Under floor ( for connection cablews ) including all re. fitting i:e elows,sockets etc. |
| 19 | Steel work welded in built up sections, trusses and framed work,including cutting,hoisting ,fixing in position and applying a priming coat of red lead paint etc. |
| 20 | Providing & fixing 10mm thick antiskid water proof stain and impect resitent resistent heavy duty vetrified tiles Nitco plaster in 1:3 (1 cement : 3 sand ) & joined with white cement slurry. |
| 21 | Painting one coat (excluding priming coat) on previously painted steel and other metal surfaces with enamel paint brushing to give an even shade including cleaning the surface of all dirt, dust and other foreign matters.With white Enamel paint. |
| 22 | White washing with lime on undecorated wall surfaces (two coats) to give an even shade including thoroughly brooming the surface to remove all dirt dust mortor drops and other foreign matter. |
| 23 | 10 mm cement plaster in single coat on fair side of brick/concrete walls for internal plastering up to floor two level including arrises, internal rounded angles, chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth. In Cement mortar 1:3 (1cement :3sand). Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender