Housing Urban and Rular Development Government Departments Closing in 8 days TDR #58518267

Tender For Construction Of Public Bathroom In Darbar Ganj Rest House At Faridkot

Issued by Government Departments · Faridkot, Punjab
Tender Value
14.99 Lakhs
Estimated cost
Bid Submission
23 Nov 2026
8 days left
EMD
29993
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Faridkot → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Public Bathroom In Darbar Ganj Rest House At Faridkot

BOQ

Name of Work:- Construction of Public Bathroom in Darbar Ganj Rest House at Faridkot
Sl. No. Item Description
1Civil Works
2Earth work in excavation in foundations, trenches etc.in all kinds of soil where pick jumper work is notinvolved and not exceeding 2.0 metres depth udingdressing of bottom and sides of ches, stacking theexcavated soil clear from the edge of excavation
3Cement concrete 1:5:10 with stone aggregates 40mm gauge mixing by mechanical means using concrete mixer volumetric type.
4First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth
5Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
6Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge.(b) Door and window frame of size 113mmx60mmxwith 35mm wide single rebate
7Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge.(c) Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
8Reinforced cement concrete M-20 mechanically batch mixed using volumetric type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
9First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
10Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels.
11Reinforced cement concrete M-20 mechanically mixed using voluemetric type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. (5902-216+136 = 5822)
12Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
13Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete.
14Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge.
15Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
16Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
17Bottom Khurra on ground 1.2m x 0.6m Mtr. Consisting of brick on edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5mm thick cement plaster 1:3.
18Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
19Terracing consiting of tiles 22.86 x 11.43 x 3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
2012.5mm thick cement plaster 1:5.
2120 mm thick cement plaster 1:5 in two coats work.
22Plastering on underside of ceiling 10mm thick cement plaster 1:3
23Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers incluidng ramming, watering and consolidated all lead .
24Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
25Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material.
26Factory manufactured Solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : IS-2202-1 (1999) (a) Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- (iv) 35 mm thick
27Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position. (a) (ii) panelled, glazed or glazed and panelled. 35mm thick
28Wire gauge Hollock wood door shutter without springs housed in chowkhat. (a) 35mm thick
29Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect (b) Glazing area above 0.09 sqm 5.0mm thick Plate glass (INDIAN)
30Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
31Providing & Fixing decorative high pressure laminated sheet 1mm (1 Star) thick with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.
32Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. complete.
33Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
34Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
35Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : (a) 300mm x 16mm
36Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. III (size of door 851mm to 1000mm)
37Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mix cement based wall putty by applying 2 or more coats to get required finish
38Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade
39Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
40Providing and Laying Out Door Precast Designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3(1 ordinary cement :3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge.
41Marble work of thickness 18-20 mm for wall lining(veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately). Slab size above 0.50 sqm
42Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect
43Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. (iii) 3mm thick ACP Sheet
44Writing matter on front signage Using high intensity Microprismatic grade retro reflective Sheeting Type IV as per ASTM D 4956 09 and as per IRC 67 2012
45Public Health Works
46Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring or laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per Sqm of tile area in average 3mm thickness over existing floor, including pointing the oints with white cement and matching pigments etc.complete
47Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS :15622 (thickness to be specified by the manufacture of approved make in all olours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
48Providing opening of required size & shape for washbasin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite / stone work, including necessary holes for pillar taps etc. including moulding, rubbingand polishing of cut edges etc. complete.
49Coloured Granite stone tiles 15mm to 20mm thick inskirting, risersof steps ,dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointedwith neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps
50Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
51Providing and fixing in position Chinaware Indian Orisa water closet size 580x440 mm of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI makred including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of Engineer-in-charge.
52Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap icluding Rack Bolt Screw Pair 115mm long complete in all respect. Size 560mm x 410mm (above counter oval)
53Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
54Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.C.P. brass Bib cock without flange
55Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.(b) C.P.brass 15mm Concealed stop cock with flange.
56(c ) C.P.brass 15mm Angle valve without flange
57Providing and fixing jet spray with 2'-6\\" long PVC pipe.(a) With C.P. Brass nut
58Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect.
59Providing & Fixing in position C.P. Brass extension piece 25mm long to 100 mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect.
60Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect.
61Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.(b) C.P brass towel ring
62Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) (a) Size 600mmx450mm
63Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect.PVC tube connection of size 15 mm x 300 mm with C.P. Brass nut
64Providing and fixing P.V.C waste pipe collapsiable 32mm complete in all respect.
65Providing and fixing in position S.S. Grating with frame of approved make (to the approval of Engineer-in-charge) complete in all respect.
66Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect.
67Providing and fixing in position vitreous Chinaware white lIndian make large flat back orangular lipped front urinal 375 x 390 x 590mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P.brass Urinal waste Coupling dome type 32mm outer length 75mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete.
68Providing and fixing partition for different type of urinalsToughned Glass Partition 8mm thickness size 450 x 900 mm C/S
69Providing and fixing in position SS Grab Bar Grade 304 of approved make (to the approval of theEngineer-in-charge) fixed in to wall with brass screws complete in all respect. (e) 35mm dia 900mm (36”) long
70(g) Foldable U Type 762mm long
71Internal and Estate Water Supply
72Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank.
73Providing and fixing in position automatic brass Ball Cock in tanks. A Plastic Ball Cock with rod and Plastic Ball (iii) 25mm i/d
74Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. © G.I. tank nipple 25mm i/d
75CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge (b) SDR 11 CPVC pipes & fittings 20mm o/d
76© SDR 11 CPVC pipes & fittings 25mm o/d
77Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.(a) Through wall 11.43 cm thick
78(b) Through wall 22.86 cm thick
79Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. (c ) 25mm i/d Brass Ball valves
80Boring with 100 mm diametre casing pipe for hand pump/ tube well in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the hand pump/tube well is lowered and tested. (a) Upto 6 mtr depth.
81(b) Beyond 6 mtr and upto 12 mtr depth.
82(c ) Beyond 12 mtr and upto 18 mtr depth.
83Providing and placing in position filters of 40 mm diametre G.I. pipe with brass strainer of approved quality.
84Providing and fixing and lowering G.I Pipe (Medium) 40 mm i/d with filter excluding cost of filter for shallow tube well including cleaning and priming the tube well.
85Construction of platform for water storage tank
86Providing and fixing of 0.5BHP motor with fitting complete in all respect as per E in C
87Internal and Estate Sewerage System
88Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing-- B Single Socket Type B(b) 110mm o/d single socket SWR UPVC pipe lines laid complete
89(c ) 90mm o/d SWR UPVC pipe lines laid complete
90Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.For 110mm i/d pipes Single Tee
91Elbow 90 Degree (All side socketed)
92Floor trap 110mm x 110mm Deep
93C For 90mm o/d pipes (iii) Single Tee
94Elbow 90 degree (all side socket)
95Providing and fixing in position C.P. brass bottle trap 32 mm dia with 40 mm seal of approved make (to the approval of Engineer in-charge) complete in all respect.
96Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge) (b ) 110mm o/d
97(c ) 90mm o/d
98Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floatingcoat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming toI.S.I complete as per standard design.(a) Size450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty double seal
99Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. (a) 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm
100Excavation manually in trenches for pipe lines with straight or open cutting in streets and lanes in built up area where width of street / Lane from wall to wall is less than 3 meter including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, watering , including the cost of dewatering of rain water, diversion for traffic, night signals. Providing & fixing caution boards, watching, fencing, etc. and removal of surplus soil from the site upto 15 meter distance complete in all respects.(a) Earth work upto 1.5 m. Depth(i) All classes of soil except rocky for 160 mm Sewer Line IC to MH 18.00 m x 0.62 m x 1.20 m
101Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. A Type A (c ) 160mm o/d SWR UPVC pipe line laid complete
102Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. For covering Sewer Line Type II For Sewer Line 160 mm i/d (Type-I) as per Detail attached
103Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 63.464 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. Inside size 75x120 cm and 120 cm deep
104Making connection of newly laid sewer in walls of existing manhole of fully charge sewer including cost of pluging sewer, desilting, removal of sullage water and making good of khudda Sewer connections upto 300 mm id
105Electrical Works
106Internal Electrical Installations- Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100 volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mmdia. (ISI Marked) recessed in wall etc., complete with powder coated/ anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box(1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material,cutting and filling up of chases (with finishing the surface):-(i) b Wiring fan Point (with Fan Box)
107(ii) Wiring Light Point
108(iv) Wiring 6 Amp Wall Socket Point
109(vi) Wiring 16/20Amp. power plug control point
110PVC HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-(x) Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed)
111PVC INSULATED PR COPPER CONDUCTOR CABLES- Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge: (II) Overall size 1.5sq.mm (Un-sheathed)
112(IV) Overall size 4sq.mm (Un-sheathed)
113(vi) Overall size 10sq.mm (Un-sheathed)
114MINIATURE CIRCUIT BREAKERS- Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/ lugs:- (II) MCB Single Pole 6-32amp. (10kA, Curve-C)
115(vi) MCB Double Pole 6-32amp. (10kA, Curve- C)
116SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- (ii) SP&N Double Door Distribution Board 8 way each
117Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
118Supply and erection of BEE 3-Star rating AC Ceiling Fan 1200mm (48\\") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 210 CMM (approx.). The rated speed of the the product must be minimum of 300 revolutions per minute and 5Nos. of speeds. The product should have a manufcaturer's guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site.
119Supply and erection of Heavy duty Exhaust Fan 300mm, 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58518267
AUTHORITY Government Departments
TENDER VALUE 14.99 Lakhs
LAST DATE 23-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of Public Bathroom In Darbar Ganj Rest House At Faridkot
Basic Detail
Tender No Tender Notice No 25 Dated 13.11.2026
Bidding Type Tender
Location
City Faridkot
State Punjab
Key Dates
Publish Date 13 Nov 2026
Submission Date 23 Nov 2026
Open Date 23 Nov 2026
Finance
Tender Value 14.99 Lakhs
Tender Fee 5000
EMD 29993
Exemption Available
Document List
0730b54e-bc6b-4b9d-af84-b9d3188b1da7.html
Additional_Conditions_366432.pdf
BOQ_366432.xls
SBD.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Nov 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

0730b54e-bc6b-4b9d-af84-b9d3188b1da7.html

pdf

Additional_Conditions_366432.pdf

xls

BOQ_366432.xls

pdf

SBD.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender