Housing Urban and Rular Development Government Departments Closing in 5 days TDR #58517921

Tender For General-State Plan Scheme 2025-26 - Scheme For Developing Circle Offices-Renovation Work For Circle Inspector Office At Balussery Police Station, Kozhikode Rural-General Civil Work

Issued by Government Departments · Kozhikode, Kerala
Tender Value
3.26 Lakhs
Estimated cost
Bid Submission
20 Nov 2026
5 days left
EMD
8200
Bank guarantee accepted
Document Fee
826
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kozhikode → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for General-State Plan Scheme 2025-26 - Scheme For Developing Circle Offices-Renovation Work For Circle Inspector Office At Balussery Police Station, Kozhikode Rural-General Civil Work

BOQ

Name of Work:- GENERAL-STATE PLAN SCHEME 2025-26 - SCHEME FOR DEVELOPING CIRCLE OFFICES-RENOVATION WORK FOR CIRCLE INSPECTOR OFFICE AT BALUSSERY POLICE STATION, KOZHIKODE RURAL-General Civil Work
Sl. No. Item Description
1CIVIL WORKS
215.23.2:Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles above 25 mm and up to 40 mm
315.3:Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
44.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
511.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
611.48.2:Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm
722.5:Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
813.80:Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
913.82.2:Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.Two coats
1013.99.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work
11OD105463/2026-2027: od92275/2021_2022 Providing and fixing good quality imported vertical blinds window curtains 100 mm width of fabric with% polyster acrylic acid coating with all connecting powder coated aluminium channels, clamps, hook and iron plate (weight) for operating etc. complete and as per the direction of the enginner in charge, including cost and conveyance of all materials and labour charges etc. complete.
1221.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
1321.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
1421.3.2:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
1550.9.12.1:Providing and fixing Thomson Multi wood board or equivalent make, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately) as per the direction of site Engineer-in-charge.
16PLUMBING AND SANITARY WORKS
1717.1.2:Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:Stainless Steel AISI-304 (18/8) orissa pattern W.C. pan of size 585x 480 with flush pipe and integrated type foot rests
1817.20.1:Providing and fixing solid plastic Seat with lid for pedestal type W.C. pan complete:White solid plastic seat with lid
1918.50.1:Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore
2018.53.1:Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore
2117.7.4:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
2250.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge.
2317.31:Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
24OD105580/2026-2027:providing and fixing CP grating 110 mm dia of good quality
25OD105581/2026-2027::Providing and fixing 110mm PVC Multi floor trap
2650.18.9.3.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge 25 mm dia 12Kfg/cm2
2750.18.9.4.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.32 mm dia 10.Kgf/cm2
2850.18.9.9.2:Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2
2950.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow
3050.18.9.22.2:Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow
3150.18.9.22.3:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow
3250.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend
33OD105586/2026-2027::Constructing inspection chambers of size 90 X 90cm inside the sewer lines upto a depth not exceeding 60cm with brick in cement mortar 1:6, 23cm (one brick) country burnt thick thick walls, forming channels inside with cement concrete 1:4:8 using 40mm broken stones, plastering the inside and channels with CM 1:3, 12mm thick with neat cement flushing coat including RCC cover slab 75 mm thick including all earthwork and foundation concrete 10cm thick
34OD105587/2026-2027:Labour Engaged (a) Coolie
35OD105588/2026-2027:Supplying and fixing PVC door (Syntex) for Toilets including cost and conveyance of all materials and labour charges etc complete.
36ELECTRICAL WORKS
371.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
381.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
391.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
401.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
411.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
421.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
431.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
441.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
451.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
461.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
471.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
481.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
491.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
501.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
511.28.6:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.12 Module
521.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
531.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
541.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
551.34:Supplying and fixing brass batten/ angle holder including connection etc. as required.
561.35:Installation, testing and commissioning of wall bracket / ceiling fittings of all sizes and shapes containing up to two GLS/CFL/LED lamps per fitting, complete with all accessories including connection etc. as required.
571.50.1:Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
581.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
591.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
6019.1:Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required:
6190.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
62OD105491/2026-2027:Supply of 20W LED batten/ tube light fittings : Supply of 20W Surface mounting type LED lenier batten/ tube light fittings with output of 2000 lumen, made out of CRCA body with white acrylic cover etc. as required.
63OD105492/2026-2027:S/F of 12 W LED Bulb : Supply and fixing of 12 W LED Bulb in the existing bulb holder as required
64OD105493/2026-2027:Supply, installation, testing and commissioning of CP Plus 8 port POE Giga switch as required
65OD105495/2026-2027:Supply and fixing UTP Cat 6 Patch chord of 2 M length of Govt. approved brand as required.
66OD105496/2026-2027:Supply and providing CAT 6 Patch Chord of 1 M length of Govt. approved make as required
67OD105497/2026-2027:Supply, marking and crimping of RJ45 connectors /sockets with boot to the CAT 6 Cable as required
68OD105498/2026-2027:S/F CAT 6 RJ 45 Modular Computer Jack : Supply and fixing of modular type CAT6 RJ 45 Computer Jack on modular GI box & cover plate and giving connections etc.as required.
692.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
70OD137320/2026-2027:SITC of Split Air-conditioner with stabilizer : Supplying, installation testing & commissioning of 5 star rated 1.5 TR split Air conditioner with supports, suitable for single phase, 50 Hz, 230 Volts , A/C supply with hermitically sealed compressor with air cooled condenser, motor capacitor start run, capacitor relay and overload protector interconnections including all accessories and remote with special purpose A/C stabilizers, filling of gas etc. as required Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58517921
AUTHORITY Government Departments
TENDER VALUE 3.26 Lakhs
LAST DATE 20-11-2026
Authority
Authority Name Kerala Police Housing And Construction Corporation Limited
Work Description Tender for General-State Plan Scheme 2025-26 - Scheme For Developing Circle Offices-Renovation Work For Circle Inspector Office At Balussery Police Station, Kozhikode Rural-General Civil Work
Basic Detail
Tender No NIT No.115/KPHCC/2026-27
Bidding Type Tender
Location
City Kozhikode
State Kerala
Key Dates
Publish Date 13 Nov 2026
Submission Date 20 Nov 2026
Open Date 23 Nov 2026
Finance
Tender Value 3.26 Lakhs
Tender Fee 826
EMD 8200
Exemption Not Available
Document List
8692bc7b-4323-4a3e-ac64-990e79782257.html
BOQ_1517821.xls
tenderdocument2023.pdf
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Nov 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

8692bc7b-4323-4a3e-ac64-990e79782257.html

xls

BOQ_1517821.xls

pdf

tenderdocument2023.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender