Tender for Repair To Roof Treatment, Chajjas, Beams, Balconies, Reinforced Cement Concrete Slabs, Mumty Roofs, Pvc Rain Water Pipes In Pcda Office Bldg Sector-09 Under Ge Chandigarh.
BOQ
| Sl. No. | Item Description |
| 1 | Taking down Cement plaster or cement lime plaster on brick or stone walls including raking out joints, hacking for key & scrubbing down with water etc complete including disposal of unservicable rubbish off the premises complete all as specified and directed by Engineer-in-Charge.Note:- Debris will be disposed as per UT norms and Contractor will laise with UT athority for the same and rates quoted shall be deemed to include this aspect. |
| 2 | Taking down steel tubing and connections of 15 mm bore in pipe with all fittings from walls,ceilings and floors and removal from site complete including disposal of unservicable rubbish off the premises complete all as specified and directed by Engineer-in-Charge.Note:- Debris will be disposed as per UT norms and Contractor will laise with UT athority for the same and rates quoted shall be deemed to include this aspect. |
| 3 | Taking down steel tubing and connections of 20 mm bore in pipe with all fittings from walls,ceilings and floors and removal from site complete including disposal of unservicable rubbish off the premises complete all as specified and directed by Engineer-in-Charge.Note:- Debris will be disposed as per UT norms and Contractor will laise with UT athority for the same and rates quoted shall be deemed to include this aspect. |
| 4 | Taking down chowkhats with shutters (without taking off shutter from frame) n exc 1.5 Sqm each with mongry including Cutting holes into through brick wall and making good to dismantled portion in CM (1:3) or PCC (1:2:4) complete including disposal of unservicable rubbish off the premises complete all as specified and directed by Engineer-in-Charge.Note:- Debris will be disposed as per UT norms and Contractor will laise with UT athority for the same and rates quoted shall be deemed to include this aspect. |
| 5 | Taking down chowkhats with shutters (without taking off shutter from frame)exc 1.5 Sqm but n exc 4 sqm each with mongry including Cutting holes into through brick wall and making good to dismantled portion in CM (1:3) or PCC (1:2:4) complete including disposal of unservicable rubbish off the premises complete all as specified and directed by Engineer-in-Charge.Note:- Debris will be disposed as per UT norms and Contractor will laise with UT athority for the same and rates quoted shall be deemed to include this aspect. |
| 6 | Raking out joints/ pointing to brick work or brick tiles, laid flat, in floors, paving and flush pointing in cement mortar 1:3 (upto 6th floor) complete including disposal of unservicable rubbish off the premises complete all as specified and directed by Engineer-in-Charge.Note:- Debris will be disposed as per UT norms and Contractor will laise with UT athority for the same and rates quoted shall be deemed to include this aspect |
| 7 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), complete including disposal of unservicable rubbish off the premises complete all as specified and directed by Engineer-in-Charge.Note:- Debris will be disposed as per UT norms and Contractor will laise with UT athority for the same and rates quoted shall be deemed to include this aspect |
| 8 | Demolition of entire Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings etc complete including disposal of unservicable rubbish off the premises complete all as specified and directed by Engineer-in-Charge.Note:- Debris will be disposed as per UT norms and Contractor will laise with UT athority for the same and rates quoted shall be deemed to include this aspect |
| 9 | Dismantling timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete including disposal of unservicable rubbish off the premises complete all as specified and directed by Engineer-in-Charge.Note:- Debris will be disposed as per UT norms and Contractor will laise with UT athority for the same and rates quoted shall be deemed to include this aspect |
| 10 | Demolition of Cement concrete unreinforced as in Ground Floor and paving n. exc. 15cm thick (above or below G.L.) complete including disposal of unservicable rubbish off the premises complete all as specified and directed by Engineer-in-Charge.Note:- Debris will be disposed as per UT norms and Contractor will laise with UT athority for the same and rates quoted shall be deemed to include this aspect |
| 11 | Demolition of cement concrete (reinforced) (reinforcement cut as required to facilitate demolition) as in roofs, floors (other than ground floors) beams, slabs, staircases, landing, chajjas and similar suspended work (upto 6th floor) complete including disposal of unservicable rubbish off the premises complete all as specified and directed by Engineer-in-Charge.Note:- Debris will be disposed as per UT norms and Contractor will laise with UT athority for the same and rates quoted shall be deemed to include this aspect |
| 12 | Cleaning the surface and making free of dirt, foreign particles, cutting or uprooting grass on old surface complete including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge.Note:- Debris will be disposed as per UT norms and Contractor will laise with UT athority for the same and rates quoted shall be deemed to include this aspect. |
| 13 | Demolition of brick work or stone/boulder masonary built in cement mortar incl all quions arches, pillar or any other descrption etc complete including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge.Note:- Debris will be disposed as per UT norms and Contractor will laise with UT athority for the same and rates quoted shall be deemed to include this aspect. |
| 14 | Dismantling of cast iron pipe/ Reinforced concrete/ PVC drain pipes/ PVC (SWR) pipe etc, 100/ 75 mm jointed in cement mortar and taking out of trenches and wall, if required complete including disposal of unservicable rubbish off the premises complete all as specified and directed by Engineer-in-Charge.Note:- Debris will be disposed as per UT norms and Contractor will laise with UT athority for the same and rates quoted shall be deemed to include this aspect |
| 15 | Dismantling wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge.Note:- Debris will be disposed as per UT norms and Contractor will laise with UT athority for the same and rates quoted shall be deemed to include this aspect. |
| 16 | Dismanting of wrought iron or mild steel of any description not otherwise provided for inany location and any position complete including disposal of unservicable rubbish off the premises complete all as specified and directed by Engineer-in-Charge.Note:- Debris will be disposed as per UT norms and Contractor will laise with UT athority for the same and rates quoted shall be deemed to include this aspect |
| 17 | Dismantling Stone slabs and tiles of paver block any description or thickness in floors, aprons etc, laid bedded and pointed in any mortar. complete including disposal of unservicable rubbish off the premises complete all as specified and directed by Engineer-in-Charge.Note:- Debris will be disposed as per UT norms and Contractor will laise with UT athority for the same and rates quoted shall be deemed to include this aspect |
| 18 | Dismantling existing Brick tiles or terracing tiles, single layer on roofs complete including disposal of unservicable rubbish off the premises complete all as specified and directed by Engineer-in-Charge.Note:- Debris will be disposed as per UT norms and Contractor will laise with UT athority for the same and rates quoted shall be deemed to include this aspect |
| 19 | Demolition of Mud phuska in roofs, any thickness,including plastering and leeping (whether full thickness removed or only a part thereof) in any position complete including disposal of unservicable rubbish off the premises complete all as specified and directed by Engineer-in-Charge.Note:- Debris will be disposed as per UT norms and Contractor will laise with UT athority for the same and rates quoted shall be deemed to include this aspect |
| 20 | Cutting grooves or rebates in parapet walls 75 mm wide and 65 mm deep and making good in cement mortar 1:3 after inserting APP membrane and shaping horizontal face of groove complete all as specified and directed by Engineer-in-Charge. |
| 21 | Cutting out cracks to 'V' section in existing roofs or terraces,cleaning out and filling solidly with a hot mixture of bitumen 85/25 and clean dry sand in the ratio of 1:1 by weight complete all as specified and directed by Engineer-in-Charge. |
| 22 | Cutting out grooves 'C' section in existing beam,lintet for construction joint to new chajja,beam complete all as specified and directed by Engineer-in-Charge. |
| 23 | Repairing the edges of concrete chajjas,facias,columns not exc 200 mm wide by providing PCC (1:2:4) type B-0 thickness 10 to 20 mm as required including all necessary formwork and provosion of rendering 10 mm thick (average thickness) in cement mortar 1:3 with chicken wire mesh after applying a coat of cement slurry @ 3 Kg/sqm of surface finished even and fair in patches including two coats of weather coat Apex paint over a coat of primer including taking down swollen/damaged plaster or concrete (upto 6th floor ) complete all as specified and directed by Engineer-in-Charge. |
| 24 | Repairing of concrete chajjas,facias,columns and the like by providing PCC (1:2:4) type B-0 thickness 15 to 20 mm as required including all necessary formwork and provosion of rendering 10 mm thick (average thickness) in cement mortar 1:3 with chicken wire mesh after applying a coat of cement slurry @ 3 Kg/sqm of surface finished even and fair in patches including two coats of weather coat Apex paint over a coat of primer including taking down swollen/damaged plaster or concrete (upto 6th floor ) complete all as specified and directed by Engineer-in-Charge. |
| 25 | Installation of rebar by using Hilti hammer drill with carbide drill bit,chemical dispensing gun for inserting RE-500V3 chemical upto minimum depth of (10 x dia of bar ) as in chajja,beam,lintel,column slab and parapet at any height before inserting an anchor bar.Hole must be free from dust debris,water,oil grease complete all as per manufacturers instructions.Note :- (i) Reinforcement shall be measured and paid separately.(ii) Rates are inclusive of form work and safety measures.(iii) Rates are inslusive of RE-500V3 Chemical (upto 6th floor) complete all as specified and directed. |
| 26 | Installation of rebar by using Hilti hammer drill with carbide drill bit,chemical dispensing gun for inserting RE-500V3 chemical upto but drilling rebarring of 12 mm dia X 160 mm deep as in chajja,beam,lintel,column slab and parapet at any height before inserting an anchor bar.Hole must be free from dust debris,water,oil grease complete all as per manufacturers instructions.Note :- (i) Reinforcement shall be measured and paid separately.(ii) Rates are inclusive of form work and safety measures.(iii) Rates are inslusive of RE-500V3 Chemical (upto 6th floor) complete all as specified and directed. |
| 27 | Providing, mixing and applying two component Epoxy resin concrete bonding coat on prepared RCC surfaces as per manufacturer specification including preparation of surface by chipping and thoroughly cleaning of surface complete wherever required and as per directions of Engineer-in-Charge in consumption of 0.4Kgs/sqm. The product should comply with ASTM C 881 Type-II Grade 2 Class B=C and bond strength should by 10MPa complete all as specified and directed. Product: Sikadur ®-32 LP or equivalent in foscroc, Asian paints as approved by GE. complete (upto 6th floor) all as specified and directed by Engineer-in-Charge. |
| 28 | Providing, mixing and applying 15-30mm thick layer of single component, fibre reinforced, sulphaste resistant, low shrinkage, high performance cementitiour structural repair mortar confirming to EN 1504-3 Class R4 on exposed concrete surface as per technical specification. Material should have compressive Strength > 55 MPa as per EN:12190, chloride iron content <0.05% as per EN:1015-17, Adhesive bond>2,0 MPa as per EN:1542, Carbonation resistenance dk < control concrete (MC (0.45) as per EN: 13295 & Elastic moduls >20.0 GPa as per EN:13412 (Complete finished item with all leads and lifts) complete all as specified and directed. Product: Sika Mono Top (R)-412 (IN) or equivalent in foscroc, Asian paints as approved by GE. complete (upto 6th floor) all as specified and directed by Engineer-in-Charge. |
| 29 | Providing, cement concrete PCC 1:2:4 type B-1 (using 20mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs stone, water troughs and the like including weathering, slightly rounded or chamfered angles and throating ( upto 6th floor), complete all as specified and directed by Engineer-in-Charge. |
| 30 | Plain cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in roof padding, roof kerbs or mud stops, back filling of chowkats, holdfasts, coping, bed plates, cills, benching rounded or chamfered on edges with and including using necessary use and waste of formwork for fair finished surface complete all as specified and directed by Engineer-in-Charge. |
| 31 | 25 mm thick Cement concrete (1:2:4) type B-0,using 12.5 mm graded mechanically crushed stone aggregate as in flooring etc. complete all as specified and directed by Engineer-in-Charge. |
| 32 | Plain Cement concrete (1:4:8) type D-2,using 40 mm graded mechanically crushed stone aggregate as in foundation,sub base,path,floor,hardstanding complete all as specified and directed by Engineer-in-Charge. |
| 33 | Reinforced cement concrete (design mix) M-25 using 20 mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts and the like (upto 6th floor) complete all as specified and directed by Engineer-in-Charge. |
| 34 | Reinforced cement concrete (nominal mix) 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like (upto 6th floor ) complete all as specified and directed by Engineer-in-Charge. |
| 35 | Reinforced cement concrete (nominal mix) 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in Chajjas,fins,facia at different floor level of PCDA Bldg with utmost care of manpower and robust formwork (upto 6th floor ) complete all as specified and directed by Engineer-in-Charge. |
| 36 | Rendering 15 mm thick in cement mortar 1:4 on fair faces of brickwork or concrete surfaces finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 37 | Rendering 10 mm thick in cement mortar 1:3, on concrete, brick surfaces/ chajja/ beams/ column mixed with water proofing compound finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.NOTE: Water proofing compound shall be measured and paid separately. |
| 38 | Supply only liquid water proofing compound ISI Marked complete all as specified and directed. |
| 39 | Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m over cleaned and dry roof surface including parapet etc complete, all as specified and as directed by Engineer-in-Charge. |
| 40 | Water proofing roof treatment/Sunken treatment using APP polymeric water proofing membrane minimum 3 mm thick and weighting not less than 3.6 Kg/Sqm black finish reinforced with non-woven polyster matt wt not less than 150 gms/Sqm with thermo fusable finish laid over compatible bitumen primer at the rate of 0.40 Ltr/Sqm over cleaned surface including parapet,applying a coat of blown bitumen 85/25 grade @ 1.2 kg per square metre over priming coat torching over laps with a propane or butane gas torch with a over lap of 100 mm at the side and 150 mm at the ends and sealing all as per manufacturers instructions incl wire brushing and cleaning the top surfaces of concrete, roof surfaces etc. with water including flashings and junction of parapets etc complete (upto 6th floor ) all as specified and directed.The rates shall be inclusive of finishing rain water gutter portion with cement mortar 1:3 to provide requisite slope towars rain water pipe outlet. |
| 41 | Use & waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc. (rough finished flat surfaces of concrete) (upto 6th floor) complete all as specified and directed by Engineer-in-Charge. |
| 42 | Use & waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions etc. (rough finished flat surfaces of concrete) (upto 6th floor) complete all as specified and directed by Engineer-in-Charge. |
| 43 | Use & waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide. (rough finished flat surfaces of concrete) (upto 6th floor) complete all as specified and directed by Engineer-in-Charge. |
| 44 | TMT steel bars 10mm dia and over, of grade Fe-500D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge. |
| 45 | TMT steel bars 6-8 mm dia and over, of grade Fe-500D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge. |
| 46 | First quality Non - skid coloured Ceramic tiles 7-8 mm thick (square/ rectangular) area of each tile of size 300 mm x 300 mm thick in floors etc. set and jointed with 4 mm spacer and grouting the joint of flooring with epoxy grout mix of organic coated filler of desired shade,hardener ,resin in the ratio of 8:1:2 laid over and inculding 15 mm thick screed in cement mortar (1:6) complete (upto 6th floor ) all as specified and directed by Engineer-in-Charge. |
| 47 | First quality Non - skid coloured Ceramic tiles 8-9 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm as in floors etc. set and jointed with 4 mm spacer and grouting the joint of flooring with epoxy grout mix of organic coated filler of desired shade,hardener ,resin in the ratio of 8:1:2 laid over and inculding 15 mm thick screed in cement mortar (1:6) complete (upto 6th floor ) all as specified and directed by Engineer-in-Charge. |
| 48 | First quality Non - skid coloured Ceramic tiles 8-9 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm as in floors etc. set and jointed with 4 mm spacer and grouting the joint of flooring with epoxy grout mix of organic coated filler of desired shade,hardener ,resin in the ratio of 8:1:2 laid over and inculding 10 mm thick screed in cement mortar (1:6) complete (upto 6th floor ) all as specified and directed by Engineer-in-Charge. |
| 49 | Glazed ceramic coloured/ printed tiles 600 x 300 x 7mm thick on vertical surface such as skirting, dado etc. over and including 10 mm thick rendering in CM 1:4 thick set and jointed with 4 mm spacer and grouting the joint of wall with epoxy grout mix of organic coated filler of desired shade,hardener ,resin in the ratio of 8:1:2 complete (upto 6th floor) all as specified and directed by Engineer-in-Charge. |
| 50 | Vitrified ceramic tiles coloured Light shade (scratch and stain resistant tiles) 8-9 mm thick (Square/ rectangular) polished, area of each tiles exceeding 0.42 Sqm but not exceeding 1.0 Sqm, in floor etc set and jointed with 4 mm spacer and grouting the joint of flooring with epoxy grout mix of organic coated filler of desired shade, hardener, resin in the ratio of 8:1:2 laid over and including 15mm thick screed bedding layer in CM (1:6) complete (upto 6th floor) all as specified and directed by Engineer-in-Charge. |
| 51 | Vitrified ceramic tiles coloured Light shade (scratch and stain resistant tiles) 8-9 mm thick (Square/rectangular) polished, area of each tiles exceeding 0.36 Sqm but not exceeding 0.72 Sqm,as in skirting etc set and jointed with 4 mm spacer and grouting the joint of flooring with epoxy grout mix of organic coated filler of desired shade,hardener ,resin in the ratio of 8:1:2 laid over and including 10mm thick rendring in CM (1:4) complete (upto 6th floor ) all as specified and directed by Engineer-in-Charge. |
| 52 | 300 x 300x 7-8 mm thick white in colour cool roof temperature shield tiles on terraces, roofs, pavements, and sloped/ vertical surfaces, set in neat cement slurry set and jointed with 4 mm spacer and grouting the joint of flooring with epoxy grout mix of organic coated filler of desired shade, hardener, resin in the ratio of 8:1:2 over and including 15 mm thick screed bed in cement mortar (1:6) complete (upto 6th floor ) as specified and directed by the Engineer-in-Charge |
| 53 | Cement concrete tiles 25cm x 25cm x 22mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors/ roof and cut and polished with grey cement and no pigment over and including 15 mm thick screed bed in cement mortar (1:6) complete (upto 6th floor ) as specified and directed by the Engineer-in-Charge |
| 54 | Machine cut Kota stone slab flooring 16-18 mm thick,SIZE 55 CM x 55 cm laid over & including 15 mm thick screed bed in cement mortar 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (mirror finish) complete (upto 6th floor ) all as specified and directed by Engineer-in-Charge. |
| 55 | Machine cut Kota stone slab 8-20 mm thick as in skirting, steps, dado and pillars etc, laid over & including 10 mm thick rendering in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (mirror finish) complete (upto 6th floor) all as specified and directed by Engineer-in-Charge. |
| 56 | Green Marble work 16 to 18 mm thick (table rubbed and Pre polished) in steps (Treads/ Riser/ Skirting), jambs, pillars, window cills, cooking platforms and like over 15mm thick screed bed/ back coat in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade including Bull nose Rounding to edges of stone slabs, such as in steps, cooking platform, and other similar works complete all as specified |
| 57 | Granite jet black shade, 18-20 mm thick, (table rubbed and polished) in single piece (in one direction) machine cut, machine polished, bedded and jointed with adhesive suitable for granite/ stone & pointed with grout of matching shade including necessary cutting over & including 15 mm thick (average thickness) cement mortar (1:4) screed and jointed with grey cement mixed with matching shade pigment including rounding of/moulding to edge (half round ) as in cooking platform, shelves, RCC counters, window cills & similar situations (upto 6th floor), complete all as specified and directed by Engineer-in-Charge. |
| 58 | 60mm thick factory made chamfered edge cement concrete coloured paver block of M-35 grade with approved colour,design & pattern as in footpath, parks,lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern with grey cement and pigment over and including 20 mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extrasand; complete all as specified and as directed. |
| 59 | Brick work with sub class 'B' bricks, class designation 100, old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge. |
| 60 | Brick work with sub class 'B' bricks, class designation 100, old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:6 but except bricks complete all as specified and directed by Engineer-in-Charge. |
| 61 | Preparation of existing surfaces like chipping of unsound weak/loose concrete/cover of reinforcement (upto 6th floor ) complete all as specified and directed by Engineer-in-Charge. |
| 62 | Cleaning the existing reinforcement with wire brush/ rotary brush to make surface clean, free from rust scales, loose materials, dust etc complete and applying two coats of alkaline rust converting primer with a coverage of 350 gms/ sqm on the existing rebar and allowing it to react with rust for 6 hours and forming corrosion resistant, insoluble and adherent protective layer including cleaning the reinforcement with wire brushing to remove rust spalls with time interval of 1 hour between the coats. (Measurement per square metre surface area of concrete). Product Sika Rustoff-100 or equivalent in Fosroc, Asian paints etc as approved by GE (upto 6th floor) complete all as specified and directed by Engineer-in-Charge. |
| 63 | (a) Scrapping and sanding with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of diameter of 7\\"/9\\" using a 80 grit sanding paper to make the surface free from dust, loose paint etc. by skilled labour complete all as directed.(b) Material and labour for two coats of cement base wall care putty over the prepared wall surface @ 1kg per sqm by mixing the putty powder by adding water as per manufacturer instructions and mixing it in putty mixer with a capacity of mixing 40 kg putty in single go. The putty mixer should have variable speed functioning for preparation of smooth and lump free putty(c) Appliying one coat of waterproofing primer/ damp-proof primer @ 1 Itr per 50 sqft. diluted with 30 % by water to be applied using roller.(d) Allow 4-6 hrs to dry the surface for painting of subsequent coats.(e) Material and labour for applying two coats of weather guard exterior acrylic emulsion paint (Ist quality) on new wall plastered surface using roller and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying acrylic emulsion should be able to hard-to-reach areas and penetration of acrylic emulsion on the surface at any height complete all as specified and directed. |
| 64 | (a) Scrapping and sanding with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of diameter of 7\\"/9\\" using a 80 grit sanding paper to make the surface free from dust, loose paint etc. by skilled labour complete all as directed.(b) Material and labour for two coats of cement base wall care putty over the prepared wall surface @ 1kg per sqm by mixing the putty powder by adding water as per manufacturer instructions and mixing it in putty mixer with a capacity of mixing 40 kg putty in single go. The putty mixer should have variable speed functioning for preparation of smooth and lump free putty(c) Appliying one coat of waterproofing primer/ damp-proof primer @ 1 Itr per 50 sqft. diluted with 30 % by water to be applied using roller.(d) Allow 4-6 hrs to dry the surface for painting of subsequent coats.(e) Material and labour for applying two coats of weather guard exterior acrylic emulsion paint (Ist quality) on old wall plastered surface using roller and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying acrylic emulsion should be able to hard-to-reach areas and penetration of acrylic emulsion on the surface at any height complete all as specified and directed. |
| 65 | (a) Scrapping and sanding with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of diameter of 7\\"/9\\" using a 80 grit sanding paper to make the surface free from dust, loose paint etc. by skilled labour complete all as directed.(b) Material and labour for two coats of wall care putty over the prepared wall surface @ 1kg per sqm by mixing the putty powder by adding water as per manufacturer instructions and mixing it in putty mixer with a capacity of mixing 40 kg putty in single go. The putty mixer should have variable speed functioning for preparation of smooth and lump free putty(c) Appliying one coat of waterproofing primer/ damp-proof primer @ 1 Itr per 50 sqft. diluted with 30 % by water to be applied using roller.(d) Allow 4-6 hrs to dry the surface for painting of subsequent coats.(e) Material and labour for applying two coats of interior premium acrylic emulsion paint on wall plastered surface using roller and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying acrylic emulsion should be able to hard-to-reach areas and penetration of acrylic emulsion on the surface at any height complete all as specified and directed. |
| 66 | (a) Scrapping and sanding with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of diameter of 7\\"/9\\" using a 80 grit sanding paper to make the surface free from dust, loose paint etc. by skilled labour complete all as directed.(b) Material and labour for two coats of wall care putty over the prepared wall surface @ 1kg per sqm by mixing the putty powder by adding water as per manufacturer instructions and mixing it in putty mixer with a capacity of mixing 40 kg putty in single go. The putty mixer should have variable speed functioning for preparation of smooth and lump free putty(c) Appliying one coat of waterproofing primer/ damp-proof primer @ 1 Itr per 50 sqft. diluted with 30 % by water to be applied using roller.(d) Allow 4-6 hrs to dry the surface for painting of subsequent coats.(e) Material and labour for applying two coats of interior premium acrylic emulsion paint on ceiling plastered surface using roller and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying acrylic emulsion should be able to hard-to-reach areas and penetration of acrylic emulsion on the surface at any height complete all as specified and directed. |
| 67 | Note for item no 63 to 66 : The work for periodical services shall include the following and the rates quoted by the bidders shall include the same :-(a) The work pertaining to periodical services shall be executed by the contractor as per MoU from authorised applicator through manufacturer of the materials like Exterior Emulsion paint, putty etc after approval by the GE. (b) The Contractor shall upload with the documents under cover I \\"Memoradum of Understanding\\" (MOU) with at least one of the manufacturers mentioned in the contract, failing which the bid shall be laible to be rejected.(c) Use of Scaffolding, trestles, ladders, cradles etc necessary for execution of work and protective measures.(d) Work in patches and in narrow / widths, bands, cornices, pilasters etc and cutting in edge of line where necessary.(f) Spreading and removing covering to doors, windows, floors, fittings etc to protect them from splashes.(g) Washing floors, cleaning glass, joinery , electric fittings , wirings etc. Drops and splashes of paint to be cleaned to the entire satisfaction of Engineer-in-Charge.(h) Sample patch of 10 Sqm be prepared considering all the items of periodical and shall be got approved from GE prior to carrying out further work. (j) Guarantee :- The contractor shall furnish a guarantee certificate from approved make in favour of Garrison Engineer for the efficieny of the exterior emulsion paint for 5 years and interior emulsion paint for 3 years during the guarantee period. |
| 68 | Supplying and fixing Aluminium Composite Panel (ACP) cladding for external surfaces, conforming to the following technical parameters as per the manufacturer's (ALEX) specifications:1. Material Composition • Panel Thickness: Total panel thickness of 6.0 mm.• Aluminium Skin: High-grade aluminium skin with a thickness of 0.50 mm on both the top and bottom coils (conforming to Type J/Exterior Grade). • Core Material: Pure Polyethylene (PE) Core sandwiched between two aluminium skins with high-performance adhesive films. Coating & Surface Finish: • Exterior Finish: Top surface coated with PVDF (70% Kynar-500) three-layer paint finish and lacquering for superior weather resistance and UV protection. • Coating Thickness: Top coil coating thickness between 25μ - 28μ; bottom coil provided with a 7μ service coat.• Protection: Visible surface protected by a branded protective film to be removed only after final installation. Fabrication: • Panels shall be cut, drilled, punched, or stamped as per the architectural drawings. • Bending, routing and 90° bending to be executed precisely without loss of surface integrity or cracking of the PVDF coating. Framework & Sub-structure: • Aluminium grid: The sub-structure shall consist of extruded aluminium square/rectangular tubes. • Brackets: Heavy-duty G.I. or aluminium “L” cleats/brackets fixed to the masonry/RCC backup wall using metallic expansion fasteners. Alignment: • The framework must be perfectly plumbed and leveled using laser levels or water tubes. Fabrication & Installation:• Panels shall be fabricated using the “Tray” or “Box” method. • Edges shall be routed and folded to form a 25–30 mm flange. Fixing: Folded edges are to be secured to the aluminium grid using stainless steel (SS) screws or rivets at intervals not exceeding 300 mm. Joints & Sealing: • Maintain a uniform groove/joint (typically 8–12 mm) between panels. • Joints must be cleaned and filled with Non-Staining Weather Silicone Sealant (e.g., Dow Corning or equivalent) over a closed-cell polyethylene backing rod. Measurement & Payment: • The measurement shall be taken on the finished visible surface area in Square Meters (Sqm). • The rate shall include the cost of ACP sheets, aluminium framework, joint sealing, wastage, fabrication, scaffolding, specialized labor, removal of the protective film, and all necessary fittings and fixtures. |
| 69 | Steel work in tubular section including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed by Engineer-in-Charge. |
| 70 | Mild steel Framed work as in doors or gates and other required of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (including) of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete with Fe 290 (Gde-E-165) complete all as specified. |
| 71 | Erection and Fixing only Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete all as as specified and directed by Engineer-in-Charge. |
| 72 | Welding in repairs exc 2.5 cm but not exc 5 cm in length,thickness of metal to be welded exc 9 mm but not exc 20 mm thick for connecting new and old reinforcement in any position any dia as required complete all as as specified and directed by Engineer-in-Charge. |
| 73 | Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. |
| 74 | Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws,hooks etc complete all as specified and as directed by Engr-in-charge.Colour to be decided by GE |
| 75 | 2 mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc fixed complete all as specified and as directed by Engr-in-charge.Colour to be decided by GE |
| 76 | 2 mm thick Fibre glass reinforced translucent plain sheeting with two 100 mm side lap fixed with coach screw and washer in roof, wall etc fixed complete all as specified and as directed by Engr-in-charge.Colour to be decided by GE |
| 77 | 6mm thick high-preformance UV-protected multiwall polycarbonate roofing sheets on steel framework, complete with two 100mm side lap fixed with coach screw and washer in roof wall etc complete all as specified and directed. |
| 78 | Powder coated aluminium (minimum thickness of powder coating 50 micron) frame work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top,bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle,Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge complete all as specified and directed by Engineer-in-Charge. |
| 79 | Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators, casements/ sliding shutters and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with rawl plugs and screws or with fixing clips or with expansion hold fastener of required dia and size, including necessary filling up the gaps at junctions, i.e. at top,bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall not be less than 2 mm thick,smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle,Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws,hinges/pivot and making provision for fixing of fittings wherever complete all as specified and directed by Engineer-in-Charge.Note : Panel fillings other tha aluminium and necessary fittings shall be measured and paid for separately |
| 80 | Stainless steel work as in Frames, grills, gratings, etc. with ends of bars shouldered and/ or riveted,or forged into spikes; framed guard bars; barred doors; ladders; framed balusters; walk ways; railingswork on forming to grade 304 complete all as as specified and directed by Engineer-in-Charge. |
| 81 | Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staples complete all as specified and directed by Engineer-in-Charge. |
| 82 | Sheet glass 5 mm thick tinted/ plain/ Figured glass type, ordinary quality and glazing with silicon sealant & spring glazing clips using Silicon for fixing of glass in addition to glazing putty, in squares not exceeding 0.5 Sq. mtr in each pane complete all as specified and directed by Engineer-in-Charge. |
| 83 | Toughned glass 12mm thick as in hinged door, partitions, automatic doors and similar work including cutting to shape, drilling holes, grinding, polishing and rounding off edges of glass, glazing with beads fixed with stainless steel panel, pins any type spigot, frameless railing, L patch connector, top and bottom patch any type of pivot side panel connecting wall mounted over panel patch with pivot, bracket and all connected fitting for door and partition any required complete all as specified and directed. |
| 84 | Material and labour handle for toughned glass door H, C-type (ladder) pull handles: design. It feaures a straight cylindrical vertical bar extending past two distinct horizontal mounting posts, fitting for door and partition including required fitting complete all as specified and directed. |
| 85 | 100 mm long extruded aluminium alloy handles, D type fabricated,anodised complete all as specified and directed by Engineer-in-Charge. |
| 86 | Aluminium anodised,barrel tower bolts of extruded section with length of bolt 150 mm and dia of bolt not less than 10 mm,ISI marked complete all as specified and directed by Engineer-in-Charge. |
| 87 | Butt hinges, cold rolled mild steel, and fixed 100 mm long medium weight complete, all as specified and as directed by Engr-in-charge. |
| 88 | Providing & fixing false ceiling at all heights with semi perforated 12 mm thick micro tegular edged GRG (Glass Fibre With Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33 mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 4mm dia fully threaded hanger rod upto 1000 mm length and L shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing . all as specified and as directed by the Engineer-in-Charge. |
| 89 | PVC solid wall panelling 5mm thick any colour/ design approved by engr-in-charge, inclusive of fixing on to wall incl moulding end caps fixed with PVC sleeves and screws as required at site and including 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed. |
| 90 | PVC hollow wall paneling 7 to 8 mm thick any colour/design approved by Engr-in-Charge, includive of fixing arrangement, PVC fillet 35 mm wide etc on to wall including moulding end caps fixing with PVC sleeves and screws as required at site complete all as specified and directed. |
| 91 | Supply and fixing in repairs 18 to 20 mm thick block board core and plywood face panels, commercial type with 0.80 mm mica on both sides any colours and fixed with screws in cup board shutters/ shelves and kitchen cabinets including 0.80 mm thick PVC edge binding tape around beading each shutter incl taking down cup board shutter, cabinat with frame and shelves complete all as specified and directed. |
| 92 | Supplying and fixing in existing position Vitreous China Wash down water closet (Pedestal pattern), white including plastic seat cover white, P or S trap, and 10 ltr capacity PVC valveless syphonic action type flushing cistern low level white with inlet ball valve float and handle with brackets, connection to outgoing pipe and flushing pipe etc complete all as specified and directed by Engineer-in-Charge. |
| 93 | Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white fixed in repairs, with integral foot rests with 'P' or 's' trap, front or back inlet (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor complete all as specified and directed. |
| 94 | 10 ltr capacity PVC valveless, syphonic action dual flush type flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, 32 mm dia flush pipe IN REPAIR complete all as specified and directed by Engineer-in-Charge. |
| 95 | Supplying and fixing in repairs fancy type Angle valve/ stop valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, all as specified, of 15mm bore, fancy type, chromium plated with long shank and cup complete all as specified and directed by Engineer-in-Charge. |
| 96 | Supplying and fixing in repairs 15 mm fancy type chromium plated fancy type bib tap brass long body with flange screwed down high pressure CP cast copper alloy with crutch or butterfly handles screwed down suitable for 15mm bore pipe or union complete all as specified and directed by Engineer-in-Charge. |
| 97 | 15 mm fancy type chromium plated fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge. |
| 98 | Supply and fixing in repair brass chromum plated single lever centre hole basin mixer without popup waste system wround spout with 375 mm long braided hoses complete all as specified and as directed. |
| 99 | Vitreous china white wash basin with pedestal (flat back or angle back type) of size 550mmx400mm coloured including MS brackets, waste coupling PTMT, and waste pipe PVC 32 mm dia including cutting for and pinning in ends of brackets or erecting stand etc, complete all as specified and as directed. |
| 100 | Supply and fixed in repair brass chromium plated, tubular towel rail, D type,20mm dia, 60cm long between flanges complete all as specified and directed by Engineer-in-Charge. |
| 101 | PVC connections 15mm size with PTMT nuts of length 450 mm fixed in repair complete all as specified and directed by Engineer-in-Charge. |
| 102 | Health faucet (ABS Body) hand shower mild steel chromium plated suitable for 8 mm dia pipe with 1 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect all as specified and directed by Engineer-in-Charge'. |
| 103 | Supply and fixed in repair spray jet brass chromium plated including suitable length of PVC connection pipe complete all as specified and directed by Engineer-in-Charge. |
| 104 | Steel water tubes, 15 mm bore, medium grade, galvanized, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floorscomplete all as specified and directed by Engineer-in-Charge. |
| 105 | Steel water tubes, 20 mm bore, medium grade, galvanized, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floorscomplete all as specified and directed by Engineer-in-Charge. |
| 106 | 50mm long magnatic catchers brass alloy body superior quality and fixed with screws complete all as specified and directed. |
| 107 | Stainless steel auto close (dadu) hinges suitable for PVC moulded shutter fixed in position with stainless steel screws, complete all as specified and directed.Make:-Godrej, Helttich india, EBCO. |
| 108 | Supply and fixing in repair telescopic channel/slider to fiacilitate drawer slide on steel ball bearing 400-500 mm long and fixed in position with stainless steel screws , ISI marked , suitable for cupboard drawers , complete as per the sample kept in the office of Engr-in-charge. |
| 109 | Continuous (piano) hinges,stainless steel, bright finish or electrogalvanised 30 mm width of flap when open complete all as specified and directed by Engineer-in-Charge. |
| 110 | Supply and fixing in repair 100 mm Brass handles, cast type, polished bright finish handle for cabinet shutter complete all as specified and directed. |
| 111 | 75mm bore, PVC (SWR) pipes with pressure rating not less than 4 Kg/sqcm,single socketed, in any length with rubber ring joints, fixed to walls with and including MS clamps made out of flat iron of size 25 mm x 3 mm including nuts,bolts or laid in trenches complete all as specified and directed by Engineer-in-Charge. |
| 112 | 110 mm bore, PVC (SWR) pipes with pressure rating not less than 4 Kg/sqcm single socketed, in any length with rubber ring joints, fixed to walls with and including MS clamps made out of flat iron of size 25 mm x 3 mm including nuts,bolts or laid in trenches complete all as specified and directed by Engineer-in-Charge. |
| 113 | PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm bore including jointing to waste pipe in cement concrete type B-1 (1:2:4) of size 200 mm x 200 mm x 250 mm fixed in repair complete all as specified and directed by Engineer in Charge. |
| 114 | PVC(SWR) bends (any radius), for 75 mm bore pipes, with access doors, complete all as specified and directed by Engineer-in-Charge. |
| 115 | PVC(SWR) bends (any radius), for 110mm bore pipes, with access doors, complete all as specified and directed by Engineer-in-Charge. |
| 116 | Note: For the purpose of arriving at Net contract sum amount, the amount of credit schedule i.e Sch 'A' section II (i.e Rs 50395.00 shall be deducted from the total amount arrived. |
| 117 | Total of Schedule 'A' Rs. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysNov 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender