Tender For Construction Of Office Cum Residential Complex Of Deo Jabalpur
Tender Value
6.74 Crore
Estimated cost
Bid Submission
18 Dec 2026
26 days left
EMD
6.62 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jabalpur → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Office Cum Residential Complex Of Deo Jabalpur
BOQ
| Sl. No. | Item Description |
| 1 | SCHEDULE \\"A\\" Part-I (Building/Structures) (To be quoted by the tenderer) |
| 2 | Item No 01 : Design (Architectural and Structural drawings) and Construction of one block of Office Building (G+1) complete all as shown in line plan drawings and all as specified in soil bearing capacity report, design basis report, and all as specified in tender documents. |
| 3 | Item No 02 : Design (Architectural and Structural drawings) and Construction of one block of Parking (S/S) complete all as shown in line plan drawings and all as specified in soil bearing capacity report, design basis report and all as specified in tender documents. |
| 4 | Item No 03 : Design (Architectural and Structural drawings) and Construction of one block of Type V Qtr including servent Qtr and parking (S/S) complete all as shown in line plan drawings and all as specified in soil bearing capacity report, design basis report and all as specified in tender documents. |
| 5 | Item No 04 : Design (Architectural and Structural drawings) and Construction of one block of Type III Qtr including stilt parking (S+2) complete all as shown in line plan drawings and all as specified in soil bearing capacity report, design basis report and all as specified in tender documents. |
| 6 | Item No 05 : Design (Architectural and Structural drawings) and Construction of one block of Type II Qtr including stilt parking (S+2) complete all as shown in line plan drawings and all as specified in soil bearing capacity report, design basis report and all as specified in tender documents. |
| 7 | Item No 06 : M & L Solid PVC Wall Lining/panelling consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawings complete all as approved and directed by GE |
| 8 | Item No 07 : M& L 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawings complete all as approved and directed by GE |
| 9 | Sch 'A' Part-II (External Electric supply) Lump sum price worked out by the contractor for (External Electric supply) as listed in Schedule 'A' Part-II against the lump sum price inserted by the MES. |
| 10 | Sch 'A' Part-III (External Water supply) Lump sum price worked out by the contractor for (External Water supply) as listed in Schedule 'A' Part-III against the lump sum price inserted by the MES. |
| 11 | Sch 'A' Part-IV (Road Path Culvert) Lump sum price worked out by the contractor for (Road Path Culvert) as listed in Schedule 'A' Part-IV against the lump sum price inserted by the MES. |
| 12 | Sch 'A' Part-V (Sewage Disposal) Lump sum price worked out by the contractor for (Sewage Disposal) as listed in Schedule 'A' Part-V against the lump sum price inserted by the MES. |
| 13 | Sch 'A' Part-VI (Area Drainage) Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule 'A' Part-VI against the lump sum price inserted by the MES. |
| 14 | Sch 'A' Part-VII (Security Wall and Gate) Lump sum price worked out by the contractor for (Security Wall and Gate) as listed in Schedule 'A' Part-VII against the lump sum price inserted by the MES. |
| 15 | Sch 'A' Part-VIII (Rain Water Harvesting) Lump sum price worked out by the contractor for (Rain Water Harvesting) as listed in Schedule 'A' Part-VIII against the lump sum price inserted by the MES. |
| 16 | Sch 'A' Part-IX (LIGHTNING PROTECTION) Lump sum price worked out by the contractor for (LIGHTNING PROTECTION) as listed in Schedule 'A' Part-IX against the lump sum price inserted by the MES. |
| 17 | Sch 'A' Part-X (Fire hydrant and fire alarm system) Lump sum price worked out by the contractor for (Fire hydrant and fire alarm system) as listed in Schedule 'A' Part-X against the lump sum price inserted by the MES. |
| 18 | Sch 'A' Part-XI (PVC Conduit for LAN and Telephone) Lump sum price worked out by the contractor for (PVC Conduit for LAN and Telephone) as listed in Schedule 'A' Part-XI against the lump sum price inserted by the MES. |
| 19 | Sch 'A' Part-XII (Site Clearance) Lump sum price worked out by the contractor for (Site Clearance) as listed in Schedule 'A' Part-XII against the lump sum price inserted by the MES. |
| 20 | Note for Srl No 9 to 20The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 9 to 20 by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule |
| 21 | Schedule 'A' Part-XIII (Miscellaneous items of works) |
| 22 | Fire hydrant and fire alarm system |
| 23 | Item No 08 : S & F wiring with PVC insulated steel armoured stranded copper conductor 1.5 Sq mm x 2 core on wall / surface with MS saddles complete all as directed. |
| 24 | LIGHTNING PROTECTION |
| 25 | Item No 09 : Supply and fixing of Earthing using copper plate earth plate electrode 60cm x 60cm x 3.15 mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to GI earth lead strip of 25 X 4 mm by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-1 2009, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil, returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete (Note: Main earth lead beyond 7.5 meter shall measured and paid saperatly.) |
| 26 | Road Path Culvert |
| 27 | Item No 10 : M&L for applying thermoplastic reflective paint in 1.5 to 2mm thick single coat as in center line and edge line road marking of 150/100mm width using 'HOT MARK' thermo plastic modern propelled road marking machine as directed including all ingredients such as binder, glass beads Titanium dioxide calcium carbonate inter fillers thermo plastic requirement for glass beads shall be the table No 800.4 of MORTH specification incl spraying of glass beads etc all as per manufacture instructions and as directed. |
| 28 | Item No 11 : Road Sign boards frame made of stainless steel pipe 50 mm dia and 3 mm thick plain aluminium sheet of Size 1200x900mm including writing of letters and logo in retro reflective tape of appropriate size and PCC 1:2:4 Type B-1 as in foundation for embedding of boards complete ( height of sign board above GL should be 2.80 Mtr and width 1.20 mtr ) all as shown on drawings and as specified and directed by EIC. |
| 29 | Item No 12 : M&L for laying and jointing 150mm nominal bore HDPE double wall corrugated pipe, socketed and sewage pipes having 6.0 mtr length, conforming to IS-16098 (Part-2) of SN-4 stiffness with and including necessary jointing materials etc complete as in road crossing all as specified and directed |
| 30 | Item No 13 : Provn of hume pipe culvert with & using Hume pipe 450 dia class NP-3 and 10.0 mtr long laid over concrete bed and jointed with coping & rendering complete all as spd. |
| 31 | EXTERNAL WATER SUPPLY |
| 32 | Item No 14 : Supply and laying, jointing and testing ductile iron(DI) pressure pipes with spigot and socket ends, S/S for rubber joints including specials class \\"K-7\\" of size 100 mm dia. complete all as specified & directed. |
| 33 | Item No 15 : Trial Boring/Drilling pilot bore of 200mm to 300mm dia (suitable for 200mm casing upto 20m depth and 150 mm casing from 20m to bore level) IS: 2800 (part 1), upto 140m to 180m depth (if encountered hard rock which cannot be encountered at certain depth then pilot boring size can be reduced to an extent of 200 mm dia on direction of Engineer in Charge) below ground level & lowering of MS pipe by any suitable method (by DTH-cum-rotary or reverse rig method) to depth below ground level in any type of strata/soil/rock with sand or loose boulder including disposal of materials obtained (soil, rock, etc) from boring to distance not exceeding 40 meter with & including deploying required rig, machinery, T & P equipments, etc complete all as specified and directed. |
| 34 | Item No 16 : Supply, assembling, lowering and levelling 200 mm nominal bore MS ERW ISI marked casing blank pipe having wall thickness 6.0 mm as per IS 1239 (Part 1)/ IS-3589 and IS 4270:2001/ (as per relavant latest IS) and jointing with electric arc welding, screwed and socketed in random length of 3 to 6 mtr, including necessary fittings i.e sockets, coupling, jointing and painting with two coats of bituminous paint of external surfaces of pipe upto depth of 200 mtr below ground level complete all as specified and directed. |
| 35 | Item No 17 : Supply, assembling, lowering and levelling 150 mm nominal bore MS ERW ISI marked casing blank pipe having wall thickness 6.0 mm as per IS 1239 (Part 1)/ IS-3589 and IS 4270:2001/ (as per relavant latest IS) and jointing with electric arc welding, screwed and socketed in random length of 3 to 6 mtr, including necessary fittings i.e sockets, coupling, jointing and painting with two coats of bituminous paint of external surfaces of pipe upto depth of 200 mtr below ground level complete all as specified and directed. |
| 36 | Item No 18 : Supply, assembling, lowering and levelling 150 mm nominal bore MS ERW ISI marked casing slotted pipe having wall thickness 6.0 mm as per IS 1239 (Part 1)/ IS-3589 and IS 4270:2001/ (as per relavant latest IS) and jointing with electric arc welding, screwed and socketed in random length of 3 to 6 mtr, including necessary fittings i.e sockets, coupling, jointing and painting with two coats of bituminous paint of external surfaces of pipe upto depth of 200 mtr below ground level complete all as specified and directed. |
| 37 | Item No 19 : Development of tube well in accordance with IS: 2800 (part 1) and IS:11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, including hire & labour charges of air compressor, tools & accessories etc. all as per requirement and direction of Engineer-in charge |
| 38 | Item No 20 : Yield test for the bore well by continuously pumpingfor 8 hours as per requirement to determine safe pumping yield & Testing of water sample and submission of reports for chemical and bacteriological analysis from the Government college /NABL cerified lab /State Govt Lab complete all as specifed and directed. |
| 39 | Item No 21 : Supply & Fixing of Submersible pump set complete suitable for 415 Volts, 3 Phase supply, 5 HP (as suitable after carrying out yield test of bore well 150 LPM Capacity, 50 Hz, Head 70 m-90m complete all as specified and directed by Engr-In-Charge. |
| 40 | Item No 22 : Supply & Fixing of Submersible cable 3 core, 4 Sqmm, PVC sheathed 1100V grade with copper conductor. complete all as specifed and directed. |
| 41 | Item No 23 : Supply and fixing cost for MS reducer, bail plug and MS strip for centering and providing support for fixing stranded steel rope complete all as specified and directed. |
| 42 | Item No 24 : M&L for making foundation thrust blocks/support pillars for holding pipe line/clamp support etc by PCC 1:2:4 type B1 (using 20mm graded aggregate size) and using extra cement making good to surfaces complete. |
| 43 | Item No 25 : Supply and Install of motorized Chemical Dosing suitable to inject solution upto 04 LPH comprising dosing pump coupled with single phase electric motor of suitable capacity, assembly with agitator, dosing and agitator in single motor, agitator with SS sweep blade duly FRP coated, FRP tank 100 ltr Ltrs capacity with agitator of suitable capacity complete unit mounted on heavy duty MS fabricated frame duly anti corrosive paint with all accessories including UPVC pipe with valves and supportings complete all as specified and directed. |
| 44 | Item No 26 : Supply only Chlorine test kit with coloured ample complete with all testing fitments and OT solution in Rexene finished box complete all as specified and as directed. |
| 45 | Item No 27 : Material and labour for Electrologging test for borewell to be done after drilling/ boring of bore hole to decide lowering of slotted pipe location as per standard procedure complete and for finding out fluid content, porosity and permeability all as specifed and directed. (Testing Engineer alongwith tool kits should be avialable immediate when the boring is near completion for loweering of pipes as per standard practice. |
| 46 | Item No 28 : Supply and filling Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in enquired grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 47 | Item No 29 : M&L Sample strata box made out of 20mm thick veneered particle board and 12mm thick plywood with 25mm x 25mm aluminium angle 2mm thick base overall length min 1500 mm x 750 mm x 100mm or as per reqmt with front glass sheet sliding type cover with aluminium frame all around with 2 Nos Key holes plates of size 40mm x 25mm and 3mm thick complete showing name of tube well location and strata chart of ground data showing different types of strata and selection of casing pipe complete all as specified and directed by Engg in charge including painting of synthetic enameled paint over to a coat of wood primer. |
| 48 | Item No 30 : S & F Centrigugal monoblock booster pump for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz 30m head, 450 LPM (5 HP) discharge including suitable size automatic pressure maintained pump starter complete all as specified and as directed. |
| 49 | Item No 31 : M&L for fabrication of CRCA sheet 2 mm thick enclosure min size 2 feet X 2 feet suitable for installation of 3 phase star delta starter 7.5 hp including 4 nos of stands made of GI angle 25 X 25 mm min 1 m incl all reqd work and pcc work complete all as specified and directed. |
| 50 | Item No 32 : Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 25 X 4 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : -(a) Excavation and earth work for drilling hole for electrode in any type of Soil.(b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. |
| 51 | (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed(d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed.(e) Requisite quantity of common salt and charcoal.(f) Testing of earthing. |
| 52 | Item No 33 : Construction of brick masonry valve pit of size 900 mm x 900mm x 900 mm (internal dimensions) with one brick thick wall in cement mortar 1 : 4 on 100 mm thick PCC 1:4:8 type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in benching and coping and 10mm thick cement plaster in CM (1:4) internally and externally upto 15cm below ground level providing valve pit cover 40x40x6mm angle iron frame all-round fixed by means of 4 Nos holdfast 150mm long made out of flat iron 40x6mm embedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) of size 230x200x100mm incl provn of hinges welded with angle iron frame and MS cover 3mm thck sheet, MS handle of suitable length and size welded with MS cover and suitable locking arrangement and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in soft/loose soil complete all as shown on drawing and as specified. |
| 53 | Item No 34 : Construction of brick masonry valve pit of size 600 mm x 600mm x 600 mm (internal dimensions) with one brick thick wall in cement mortar 1 : 4 on 100 mm thick PCC 1:4:8 type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in benching and coping and 10mm thick cement plaster in CM (1:4) internally and externally upto 15cm below ground level providing valve pit cover 40x40x6mm angle iron frame all-round fixed by means of 4 Nos holdfast 150mm long made out of flat iron 40x6mm embedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) of size 230x200x100mm incl provn of hinges welded with angle iron frame and MS cover 3mm thck sheet, MS handle of suitable length and size welded with MS cover and suitable locking arrangement and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in soft/loose soil complete all as shown on drawing and as specified. |
| 54 | Pump House |
| 55 | Item No 35 : Design (Architectural and Structural drawings) and Construction of block of Pump House (S/S) complete all as shown in line plan drawings and all as specified in soil bearing capacity report, design basis report, and all as specified in tender documents. |
| 56 | Item No 36 : Design (Architectural and Structural drawings) and Construction of RCC underground water sump of Cap 20000 Liters having approximately 5.00 meter dia and all other dimensions matching with capacity all as specified and directed by GE.Note:- (a) Sufficient Nos of opening on semi circular top with cover.(b) SS ladder provided for internal approach up to bottom(c) Water proofing treatment as per relevant IS Code(d) Design as per relevant IS Code duly vetted from IIT and accepted by Rep of CE Jabalpur Zone |
| 57 | External Electric supply |
| 58 | Item No 37 : M& L for cable root indicator MS sheet embossed with LT 1100 Volts UG made with CI Plate 6 mm thick fixed with MS angle Iron of size 30x30x4mm of length 400 mm long including PCC work 1:2:4 type B1 of size 150x150x150 mm complete all as specified & directed |
| 59 | Item No 38 : M& L for cable root indicator MS sheet embossed with HT 11000 Volts UG made with CI Plate 6 mm thick fixed with MS angle Iron of size 30x30x4mm of length 400 mm long including PCC work 1:2:4 type B1 of size 150x150x150 mm complete all as specified & directed |
| 60 | Item No 39 : S & F Junction Box for Street Lights of size 200 x 250 x 150 mm or nearest size made out of CRCA sheet 2 mm thick totally enclosed, dust and vermin proof, rain protected slant roof top, door with rubber gasket, water gutter, lock arrange, 1 No. 24 pole/position single leaf shutter in front having proper locking arrangements, and painted with powder coating paint of approved color shade including Din Rail (with provision for socket bolting). 05 Nos arrangement for 415 volts, 50 Hz, 3 phase- 4 wire internal wiring system including MCB SP 06 amps - 01 No and mounted on security light pole with suitable bracket nuts, bolts complete all as specified and directed. |
| 61 | Item No 40 : S & F Integral decorative LED bollard with IP 65/66 protection suitable for 10 watts LED with necessary electrical connections with adequate size of Nuts and Bolts complete as all specified and as directed. |
| 62 | Item No 41 : Supply, installing, testing and commissioning out door type LT panel board of suitable size, padestal mounted, CPRI approved factory made, totally enclosed, dust and vermin proof, shutter in front and in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and external surfaces with following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick , 1 Mtr all round the panel board complete with the following items housed in (Main Panel) |
| 63 | BUSBAR :- (i) 400 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator, bus bar support (Square/round) insulators of suitable size and good insulation resistanceINCOMING :-(i) MCCB 4 Pole 250 Amps, with Microprocessor based with thermal memory, Fully rated neutral with in built protection, , Short circuit breaking capacity 25 KA @440 volts AC, - 02 No (1 stand by)(ii) Digital Voltmeter 0- 500 Volt with in built selector switch - 01 No. |
| 64 | (iii) Digital Ammeter 0- 1000 Amp No with in built selector switch - 01 No.(iv) Indicator Lamps (LED type) & bakelite fuseshowing R,Y, B phase - 01 set(v) Digital frequency meter 40-60 Hz - 01 No.(vi) Copper wound with rated CTR - 03 NosOUT GOING(i) MCCB 4 Pole 125 Amps,with Microprocessor based with thermal memory, Fully rated neutral with in built protection, breaking capacity 25 kA @440 volts AC, - 01 No (ADM BLOCK )(ii) MCCB 4 Pole 125 Amps, Rotary Handle, adjustable Thermal Magnetic relay with breaking capacity 25 kA at 415 volts- 01 Nos (Accrdtn )(iii) MCB 4 Pole 40Amps, Rotary Handle, adjustable Thermal Magnetic relay with breaking capacity 10 kA at 415 volts - 01 No(Borewell )(iv) MCB 4 Pole 32 Amps, Rotary Handle, adjustable Thermal Magnetic relay with breaking capacity 10 kA at 415 volts- 01 Nos (security light ) |
| 65 | Item No 42 : Supply, installing, testing and commissioning out door type LT feeder piler box of suitable size, padestal mounted, CPRI approved factory made, totally enclosed, dust and vermin proof, shutter in front and in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and external surfaces with following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick , 1 Mtr all round the panel board complete with the following items housed in : Panel for Accn) |
| 66 | BUSBAR :- (i) 200 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator, bus bar support (Square/round) insulators of suitable size and good insulation resistanceINCOMING :-(i) MCCB 4 Pole 125 Amps, 25 kA with Rotary Handle, microprocessor release a Inbuilt Thermal Memory- 01 No (In coming)OUT GOING(i) MCCB 4 Pole 40 Amps, Rotary Handle, adjustable Thermal Magnetic relay with breaking capacity 16 kA at 415 volts 03 No (for Qtrs )(ii) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase - 01 set of 3 |
| 67 | (iii) Digital Voltmeter 0 - 500 Volt with in built selector switch - 01 No.(iv) Digital Ammeter 0 - 250 Amp with in built selector switch - 01 No.(v) Indicator Lamps (LED type) & bakelite fuse fuseshowing R,Y, B phase - 01 set(vi) Digital frequency meter 40-60 Hz - 01 No.(vii) Copper wound with rated CTR - 03 Nos(viii) Auto control time switch, timer control for different 24 hours adjustable type including power contactor of rated capacity complete- 01 No |
| 68 | Item No 43 : Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground, (Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 32x 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following :- |
| 69 | (a) Excavation and earth work for drilling hole for electrode in any type of Soil.(b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter.(c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed(d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed.(e) Requisite quantity of common salt and charcoal.(f) Testing of earthing. |
| 70 | Item No 44 : Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground, (Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth CI Wire 4 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following :-(a) Excavation and earth work for drilling hole for electrode in any type of Soil.(b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter.(c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed(d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed.(e) Requisite quantity of common salt and charcoal.(f) Testing of earthing. |
| 71 | Sewage Disposal |
| 72 | Item No 45 : M & L for laying DWCP 150mm Minimum internal dia pipes in trenches class SN-8 conforming to IS-16098 (Part-2) in 6 mtr length with coulper complete all as specifed and directed. |
| 73 | Item No 46 : Construction of Conventional RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls, Base Slab, Baffle walls and Roof Slab including beams etc with Vent shaft, manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter complete for 100 users. |
| 74 | Item No 47 : Construction of Conventional RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls, Base Slab, Baffle walls and Roof Slab including beams etc with Vent shaft, manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter complete for 25 users. |
| 75 | Item No 48 : Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.0 m dia and 3.0 m effective depth. |
| 76 | Security Fencing and Gate |
| 77 | Item No 49 : Supply and fixing RCC M-35 grade precast pre-stressed boundary wall 2.10 m high above GL, and shall consist of RCC precast column and RCC pre-cast prestressed panels. The size of RCC precast column shall be of 150 mm x 150 mm fixed on ground (0.60 m deep below GL & 2.10 m above GL) @ 2.0m c/c with PCC. The RCC pre-cast prestressed panels shall be 305 mm wide x 50 mm thick inserted into RCC column from GL to top of RCC precast column i.e. upto 2.1 m high, complete all as specified and directed.Note : - (a) Excavation for post hole and PCC for embedding RCC precast column shall be measured and paid sepratly |
| 78 | Rain Water Harvesting |
| 79 | Item No 50 : M&L for loose filling with broken stone or boulder aggregate of gauge 20 as in filter bed complete all as specified. Please Enable Macros to View BoQ information Schedule 'A' Part II (External Electric supply) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 80 | Supply and erecting steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws complete all as specified, type 410 SP-55 of 11 mtr long including painting of pole with one coat red oxide primer & two coat of aluminum paint & embedded portion of pole shall be painted with two coat of black paint complete all as specified and as directed. |
| 81 | M&L for cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint complete all as specified and directed. |
| 82 | Supply and fixing Pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade confirming to IS-2486 complete all as specified and as directed. |
| 83 | Supply and fixing of switch air break gang operated triple pole mechanically operated horizontal type out door with all other fittings/accessories mounted on & including porcelain insulators and steel frame with operating mechanism worked from ground level with & including operating rod of 32mm dia GI pipe medium grade (ISI marked) with MS handle with locking arrangement, for current rating up to 200 Amp 11000 Volts including dropout fuse set 15 insulators to suit gang operated triple pole 11 KV switch, connecting, commissioning and testing on completion complete all as specified and directed. |
| 84 | S&F for lightning arrestor Expulsion type complete with all fittings, transmission/ distribution class, (RMS) discharge current 10 KA suitable for rated system voltage of 12 KV supply system with maximum continuous operating Voltage (MCOV) not less than 7.65 KV (RMS) with highly non linear ceramic resister made of Zinc Oxide in hermetically sealed container and mounting on poles including all necessary bolts, nuts and washers and making electric connection and testing on completion complete all as specified and directed. |
| 85 | Supply, installation, testing and commissioning of copper wound (double wound), step down transformer of capacity 160 KVA (Level 3), plinth/ floor mounted, OUT DOOR TYPE and conforming to IS 1180:2014, AC 3 phase 50 Hz, ONAN with external cooling tubes/ radiators, having no load voltage ratio 11/0.433 KV corresponding to protected primary side (11KV HV side) and star connected protected secondary side (433V LV side) in accordance with vector symbol Dyn-11 (Vector Group), manual type off load tap changing facility on HT side to vary secondary voltage from +5% to -7.5% in steps, ISI marked duly filtered & dehydrated etc. Transformer shall be mounted on and including suitable platform of approx size 2.0Mx 2.0M, 1.50M high (outer dimension) built with 150mm thick PCC 1:5:10 type E2 using 40mm graded stone aggregate as in foundation extending 150mm on both sides of wall, 350mm thick of brick masonry built in CM 1:6 using old size sub class 'B' bricks, brick masonry shall be 450mm below GL & 550mm above GL, exposed faces of brick work up to 150mm below exposed ground level shall be plastered in CM 1:4 & flush in same mortar as work proceeds on faces in contact with soil, floor shall be 100mm thick with PCC 1:2:4 type B-1 using 20mm graded stone aggregate, laid in bays over & including 100mm thick hardcore over approved earth filling, exposed plastered surfaces shall be given three coats of white wash over appropriate cement primer necessary excavation and earth work over complete all as specified and directed. The unit rate of transformer shall also includes the cost of following accessories/ fittings (a) Externally hand operated off-circuit Tap switch with position indicator and locking device.(b) Conservator with oil gauge, filling hole with plug & drain hole with plug.(c) Under vehicle with four plain rollers.(d) Oil filling hole with pipe & gas release plug - 01 No(e) Drain valve cum sampling valve - 01 No.(f) Filter valve with plug - 01 No.(g) Lifting plate & Diagram plate - 01 No(h) Lifting lugs for transformer - 02 Nos (i) Lifting lugs for lid - 02 Nos(j) Earthing terminals - 02 Nos(k) Thermometer pocket - 01 No(l) Silica gel breather - 01 No.(m) Terminal marking plate - 01 No.(n) Winding temperature indicator in oil 40 deg centigrade and windings 45 deg centigrade.(o) Fitting accessories conforms to IS 1180 (Part-1): 2014 Level-3 and as per clause No 16.14.1.2 of SSR Part I.(p) Maximum losses of transformer shall be strictly as per energy efficiency level 3 as per IS 1180 (Part-I): 2014.(q) Oil level gauge nd oil level min and max.(r) Explosion vent - 01 No.(s) 6\\" Dial thermometer with alarm and trip contact and maximum temp. - 01 No. (t) Mounting arrangement shall be provided with two 75x40 mm channels 460mm long,(u) Suitable plinth of height 1.5M above G.L. at suitable layout of transformer.(v) Cable termination box on both sides (HV Side & LV Side suitable connections )Plinth required for mounting Transformer as per above description.Note:-(i) The contractor shall submit preliminary drawing for approval to GE.(ii) Factory inspection before dispatch shall be done by an officer of AGE/EE/AEE/AE/Assistant Director.(iii) Pre-Commissioning of transformer shall be undertaken as per standard practice. |
| 86 | Supply, lay and testing cable 3 core x 95 Sq mm XLPE earthed insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 volt with stranded aluminium conductor complete all as specified. |
| 87 | Supply and fixing HT 11 KV (Earthed) grade cold shrinkable end termination jointing kit outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 65-95 sqmm complete all as specified and as directed. |
| 88 | Supply and laying & testing and commissioning LT underground cable 1100 volts grade, XLPE insulated and PVC sheathed heavy duty armoured with multi stranded aluminium conductor laid in pipes, trenches/ducts, on poles etc:(a) 3.5 core x 95 sqmm (Transformer to Main LT Panel) (b) 3.5 core 50 sqmm (main LT Panel to adm bldg) RM 337.52 120.0 40502.4 (c) 3.5 core 35 sqmm (Main LT Panel to Accn LT Panel) RM 269.75 140.0 37765.0 (d) 4 core 25 sqmm (type iii & ii Qtr) RM 249.04 130.0 32375.2 (e) 4 core x 16 sq mm (type v Qtr & LT Panel Pump House) RM 193.5 120.0 23220.0 (f) 4 core x 10 sqmm (Security lights) RM 174.68 960.0 167692.8 (g) 2 core x 10 sqmm (Garden lighting) RM 143.61 450.0 64624.5 |
| 89 | Excavation in trenches not exceeding 1.5m deep & not exceeding 1.5m wide or area not exceeding 10 Sqm on plan, in any type of soil and getting out for foundation, trenches or laying of electric cable or pipes complete all as specified and as directed. |
| 90 | Returning, filling in, excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed. |
| 91 | Removal of excavated materials (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
| 92 | M&L dry river washed/black and screened dry sand for filling in trenches below and around the cable for cushioning including punning down as specified in relevant clause of SSR Part I complete all as specified and directed. |
| 93 | Supplying and laying unreinforced precast concrete cable cover, class LV Type 2 flat, size 300mm x 180mm x 40mm complete all as specified and directed by Engr in charge. |
| 94 | Supplying and laying unreinforced precast concrete cable cover, class HV Type 2 flat, size 450mm x 180mm x 40mm complete all as specified and directed by Engr in charge. |
| 95 | Supply, fix for Energy saving new generation environmentally friendly long life versatile pressure die cast aluminium IP 66 security light fitting complete with driver and power LEDs as light source and electronic driver of capacity 70/72 watts with pre wired including GI bracket 40mm dia appx 1.5 m length and testing complete all as specified and directed provision of 1.5 sq mm twin core aluminium conductor cable multi stranded from fitting to over head line and testing complete all as specified. |
| 96 | Supply, fix for LED post top lantern 40 watt light fitting made of cast aluminium spigot housing with decorative opal acrylic diffuser with IP 65 protection complete with all accessories fixed on GI pipe 50 mm dia complete all as specified and directed. |
| 97 | Supply and fix All in One Solar LED Street Light fittings of 60 Watt, Solar PV Module of 12 V ,100 Wp- Monocrystalline 12.8V / 42 Ah Li Fepo4 battery inbuilt , with PIR Sensor with Color sensor 6000-6500K , 3 days with dimming backup, MPPT Solar Charger Controller with 12.8 V ,10 amp driver, extruded Al Body IP 65 suitable for -10 to 55 degree celcius with all mounting accessories including cross arms , tracing ,support, clamps and back plates ,fabricated from structural steel section including nuts, bolts, washers and other standard with brand toll free sticker for brand installation and services with min 2 year warranty of battery , 5 year for LED light 25 years for solar panel . |
| 98 | M&L for PCC (1:2:4) type B2 using 20 mm graded stone aggregate as in foundation, filling, mass concrete and pilasters, buttresses columns, posts etc complete all as specified & directed. |
| 99 | M&L for Precast Cement Concrete(RCC) 1:4:8 type D2 using 40 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and minimum reinforcement. |
| 100 | M&L for PCC (1:3:6) type B2 using 20 mm graded stone aggregate as in foundation, filling, mass concrete and pilasters, buttresses columns, posts etc complete all as specified & directed. |
| 101 | Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-22 (9.0 metres long) Complete all as Specified and Directed. Total carried over to BOQ Rs. 4143452.25 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part III (External Water supply) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 102 | Supply, fixing & laying GI tubing medium grade with one socket both end threaded in any length including cutting threading connection in new or old position and all type of GI new fittings for laid in trenches/wall/ceiling/floor/ all as specified and directed of following size :-(a) 80mm (b) 50 mm RM 505.0 100.0 50500.0 (c) 25 mm RM 196.0 100.0 19600.0 |
| 103 | S & F for Valve, sluice Valve of dia 100mm with SS spindle and Gun metal flanged of class 1.0 PN including nut bolts, gasket and as per relevant IS code complete all as specified. |
| 104 | S & F Stop / gate valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for following size(a) 50 mm (b) 25 mm Each 784.97 16.0 12559.52 |
| 105 | Supply and fixing 100mm bore CI Non Return Valve as per relavant IS, PN rating 1.0 ISI marked all as specified and directed. |
| 106 | Supply, fixing & laying GI tubing 80 mm Dia HEAVY grade with both end flanged including cutting threading connection in new or old position and all type of GI new fittings for laid in trenches/ wall/ ceiling/ floor complete all as specified and directed. |
| 107 | Excavation in trenches not exceeding 1.5m deep & not exceeding 1.5m wide or area not exceeding 10 Sqm on plan, in any type of soil and getting out for foundation, trenches or laying of electric cable or pipes complete all as specified and as directed. |
| 108 | Returning, filling in, excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed. |
| 109 | Removal of excavated materials (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. Total carried over to BOQ Rs. 263210.26 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part IV (Road Path Culvert) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 110 | M & L for Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10sqm on plan) all kind of soil including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-incharge |
| 111 | Rolling and consolidation of formation surfaces with 8 to 12 tonne power roller all as spd and directed. |
| 112 | M & L Laying and compacting 150 mm thick (compacted thickness) Granular Sub Base Course GSB Grade III as per Table 900-1 of MoRTH specifications for Road and Bridge works 2013., in a single layer over compacted subgrade with natural sand, crushed gravel, crushed stone, crushed slag or combination thereof as per the grading required The materials are mechanically mixed, spread and leveling on the subgrade by using motor grader of adequate capacity, and rolling with vibratory roller of capacity 80-1 00 KN static weight for achieving required compaction density of atleast 98% of the Maximum Dry Density. Consolidating to required gradient and camber complete all as specified and directed with finished surface tolerances as per Table 900-1 of MoRTH specifications for Road and Bridge works, 2013. |
| 113 | M & L for Laying and compacting 150 mm thick (compacted thickness ) WMM laid in two layers of 75 mm each Wet Mix Macadam (WMM) grading as per table 400-13 of MoRTH specifications for Road and Bridge works 2013 manufactured in WMM plant material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-1 OOKN static weight and consolidating to required gradient and camber complete all as specified and directed The finished surface tolerances to be as per Table 900-1 of MoRTH specifications for Road and Bridge works 2013 complete all as specified. |
| 114 | M&L for preparing unsurfaced WMM surfaces by brushing with wire brushes for removing caked mud etc, sweeping with brooms and finally fanning the cleaned surface to remove all loose dirt etc complete all as spd and directed. |
| 115 | M&L applying evenly a priming/tack coat with bituminous primer at 10 kg/10 Sqm using (VG-10) paving bitumen complete all as spd and as directed |
| 116 | M&L for Premix bituminous, macadam laid/rolled and compacted to required gradient and camber (consolidated thickness 75mm or less) using bitumen Vg 30 Grade @ 4% by weight of aggregate including cleaning of water bound macadam and rolled with 8 to 10 tonne power roller all as spd. |
| 117 | M & L for laying of Bituminous premix semi dense asphaltic concrete using mechanical paver 40mm consolidated thickness with 5.5% binder content by weight of total mix, rolled and compacted to required camber and gradient with 8 to 12 tonne power roller, on existing black top surface complete all as spd and directed. |
| 118 | Supply and fixing cat eye solar reflective type of metal body alloy of size 100mm x 100mm x 20mm with PAMA striplens reflector of model No. DA 972.0 fixed with and incl MS stud of suitable size as per manufactures instructions. Make: 3M 290 Series of Road Star or equivalent Model of make- Dark Eye or Green Lite or Sun Lite. |
| 119 | Supply and fixing metal tubular delineator made out of ABS round body fitted with 2 Nos 65 mm dia highly reflective reflectors made out of PMMA and mounted on 45/50 mm dia mild steel pipe of 600 mm height duly powder coated and thermo plastic elastomer 3 bands of green, red and yellow reflector radium tape of 25 mm wide strips with anti theft steel net for reflector protection including embedding in PCC 1:2:4 (150x150x300mm) type B1 complete all as specified and directed. |
| 120 | Supply and fix solar cat eye/ studs of size 125mmx 125mmx 25mm (shank 60mm) with aluminium alloy shell, high efficiency mono-crystalline solar panel 2.40V/0.30 watt having one Ni-Mh or NI-cd rechargeable battery (1.2V/ 1600MA), six super bright LEDs with 10,000 to 18,000 mcd (Millicandela) having flash rate 2 Hz and bearable weight 10 tons approx with view distance upto 1000 meters of any colour i.e yellow & red as required at site, working temp 10°-75°C, working time 3 to 4 days after fully charged battery, charging time 5 to 6 hours from direct sun light, maintenance free, un-breakable poly carbonate clear facing, automatically turns on at night and turns off at day incl all fixing arrangement as per manufactures instructions complete all as specified and directed. Make: 3M / DA 110 (DHRUV) of DARK EYE or equivalent Model of Make Road Star or Green Lite or Sun Lite |
| 121 | M &L for Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out soft of loose soil complete all as specified and directed by Engr-in-charge. |
| 122 | Removing excavated material exc 50 M but n.exc 250 m and depositing were directed at a level nexc 1.5m above the starting point all as spd and directed. |
| 123 | Moorum/laid bajri filling in floor or paving laid in layers not exceeding 15cm thick, spread, leveled and rammed incl watering complete all as specified |
| 124 | M & L for cement concrete type D-2, 1:4:8, using 40mm graded stone aggregate as in sub base complete all as specified. |
| 125 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc of required strength thickness & shape/size made by table vibratory method using PU mould, laid in required colour & pattern over and incl 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of interlocking paver blocks as per required size and pattern finishing and sweeping extra sand complete all as specified and directed |
| 126 | M & L PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in benching coping etc including necessary form work complete all as spd and directed. |
| 127 | M & L for Factory made precast cement concrete blocks made of 1:2:4 type B-1, using 20mm graded stone agg as in kerb stone chamfered fixed in CM 1:6 complete all as specified |
| 128 | M & L for 2 coat of synthetic enamel paint over a coat of primer on concrete Surfaces of any description, exceeding 10cm in width or girth Total carried over to BOQ Rs. 6609800.23 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part V (Sewage Disposal) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 129 | Excavation in trenches n exc 1.5 m wide and n exc 1.50 m in depth & getting out in hard / dense soil. |
| 130 | M & L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 150mm bore of pipe with cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate complete all as specifed and directed. |
| 131 | M & L PCC 1:4:8 type D-2 in foundation, filling and mass concrete (using 40 mm graded crushed stone aggregate). |
| 132 | M&L for Brick work with sub class 'B' bircks straight or curved on plan exc 6mtr mean radius in CM 1:4 complete all as spfd. |
| 133 | M & L for 15mm thick rendering on any faces of stone, concrete or brick work in CM 1:4 surface finished even and fair complete all as spfd. |
| 134 | M & L for 15mm thick rendering on any faces of stone, concrete or brick work in CM 1:6 surface(with out using extra cement) complete all as spfd. |
| 135 | M & L for Intergral water proofing compound complete all as spfd. |
| 136 | M & L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi-tred/stopped ends etc. complete all as spfd. |
| 137 | M&L for PCC 1:2:4 type B-1 using 20 mm graded aggregate as in bed blocks, bed blocks of hold fasts, coping and chamfered angles and throating etc. |
| 138 | M & L Precast (factory made frame and cover) cement concrete Type B-1, 1:2:4 (using 20mm graded stone aggregate) in landings, cover slabs (for manholes) shelves and similar articles with plain faces and set in CM 1:6 complete all as spfd. |
| 139 | S & F TMT steel bars 6 to 8mm in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) complete all as specifed and directed. |
| 140 | Returning, filling in, including spreading, levelling, watering & well ramming in layers n exc 25 cm with any type of soil |
| 141 | Removing excavated material n exc 50 m and depositing where directed at a level n. exc 1.50 m above the starting point all as directed Total carried over to BOQ Rs. 336111.66 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part VI (Area Drainage) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 142 | Excavation in trenches nexc 1.5m wide-cum and nexc 1.5m in depth for foundation and getting out in soft/loose soil all as specified and directed. |
| 143 | M&L for PCC 1:4:8 type D-2(using 40mm graded stone aggregates) as in bedding of drain etc all as specified and directed. |
| 144 | M&L for brick work with sub class 'B' bricks built in cement mortar 1:4 straight on plan using old size bricks all as specified and directed. |
| 145 | M&L for PCC 1:2:4 type B-2 (using 40 mm graded stone aggregates) as in surface channel and drain etc. surface finished even and fair all as specified and directed. |
| 146 | M&L for PCC 1:2:4 type B-1(using 20mm graded stone aggregates) as in coping of drains including necessary formwork etc all as specified and directed. |
| 147 | M&L for 15mm thick cement plaster on brick surfaces of drain in cement mortar 1:4 surface finished even and smooth without using extra cement all as specified and directed. |
| 148 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends, etc. all as specified and directed. |
| 149 | Returning, filling in including watering and well ramming in layers nexc 25cm thick all as specified and directed. |
| 150 | Removal of surplus soil to a distance exc 50m but nexc 250m and depositing where directed at a level nexc 1.5m above starting point all as specified and directed. |
| 151 | M&L for MS TMT bar 10 dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.90mm dia or securing with clips complete all as specified and directed. |
| 152 | M&L for pre-cast RCC slabs as in manhole covers in 1:2:4 type B1 using 20 mm graded stone aggregate set in cement mortar (1:4) incl use and waste of form work complete all as specified and directed. Total carried over to BOQ Rs. 1520815.25 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part VII (Security Fencing and Gate) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 153 | Excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation, n.exc 10 sqm on plan n.exc 1.5m in depth and getting out in soft/loose soil all as specified and directed. |
| 154 | M&L PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed |
| 155 | M&L PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. |
| 156 | Use & Waste of Form work to sides of concrete foundations, footings, Bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished surface of concrete complete all as specified and directed. |
| 157 | M&L RCC design mix M-25 using 20mm graded stone aggregate as in foundation including rafts, footings, foundation beams, plinth beams, bases for columns, etc., basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 158 | Use & Waste of Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surface of concrete complete all as specified and directed. |
| 159 | M&L RCC design mix M-25 using 20mm graded stone aggregate as in pillars, posts, struts, piers, columns and stanchions complete all as specified and directed. |
| 160 | Use & Waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves, including supports, overhangs, etc., for rough finished surface of concrete complete all as specified and directed. |
| 161 | M&L RCC design mix M-25 using 20mm graded stone aggregate as in beams, lintels, lintel beams, cantilevers, bressummers, Lintels over 1.5m span complete all as specified and directed. |
| 162 | PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping, benching, bed block, and similar work incl weathering slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed. |
| 163 | M&L Rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surface of wall finish even and smooth without using extra cement complete all as specified and directed. |
| 164 | M&L Mild Steel TMT bar 10mm dia and over as in reinforcement, cut to length, bent to shape required including cranking, bending spirally for hooping ends and binding with & incl Mild Steel wire not less than 0.90mm dia complete all as specified and directed. |
| 165 | M&L MS TMT bar 5mm dia and over upto & incl 10mm dia as in reinforcement, cut to length, bent to shape required including cranking, bending as in stirrups, spacers and binders and binding with & incl ms wire not less than 0.90mm dia complete all as specified and directed. |
| 166 | M&L for Framed work as in doors or gates of angle or other section ornamental type with gusset plates, rails, braces etc completed drilled for fixing of steel sheet or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheet) and also hold fasts, fastening and fixing complete all as specified and directed. |
| 167 | S&F Mild steel posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) incl all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 168 | S&F Galvanized 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard, rails, straining, securing or tying at crossings with and provision of galvanized mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) |
| 169 | Preparing new steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 170 | Preparing new or newly plastered surfaces, applying two coats of cement based paint over a coat of cement wash with portland cement slurry complete all as specified and directed. |
| 171 | Excavating in post holes (or similar holes) each n.exc 0.5 cu m, getting out, returning, filling in and ramming foundation earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, getting out any tybe of soil complete. |
| 172 | Returning, filling in, including watering and well ramming in layers not exc 25cm thick, all as complete all as specified and directed. |
| 173 | Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting point complete all as specified and directed. |
| 174 | M&L 20mm thick Granite slab machine cut, in vehicle surfaces over & incl 20mm thick cement screed in CM 1:4 and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone incl grinding and polishing complete all as specified. |
| 175 | Rounding to edges of stone slabs edge such, as in steps, cooking platform, and other similar situations complete all as specified and directed. |
| 176 | Supply only chain link fencing including any size of type of standards, rails, straining bolts, etc. including provision of binding wire |
| 177 | Fixing only chain link fencing including line wires, any mesh and type to any type of standards, rails, straining bolts, etc. including provision of binding wire Total carried over to BOQ Rs. 1983696.44 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part VIII (Rain Water Harvesting) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 178 | Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth for foundation, r. exc 1.5m and getting out in soft/loose soil complete all as specified and directed. |
| 179 | Earthwork in excavation by mechanical means over area in any kind of soil (exceeding 30 cm deep, 1.5 m in width as well as exceeding 10 Sqm in plan area) including getting out and disposal of excavated earth lead up to 50 m and lead upto 1.5 m complete all as specified an das directed. |
| 180 | All as per item No 2 above but exc 1.5 m but not exc 3.0 m deep |
| 181 | All as per item No 2 above but exc 3.00 m but not exc 4.5 m deep |
| 182 | All as per item No 2 above but exc 4.50 m but not exc 6.0 m deep |
| 183 | M&L for PCC 1:4:8 type D-2 using 40mm graded stone agg as in fdn filling, mass concrete etc complete all as specified. |
| 184 | M & L for Brick work with Sub class 'B' bricks, old size, straight or curved on plan exc. 6m radius built in cement mortar 1:4 complete all as specified. |
| 185 | M & L for PCC 1:2:4 mix type B1 using (20mm graded stone aggregate) as in coping complete all as specified. |
| 186 | 100 mm thick PCC 1:2:4 type B 2 (40mm graded aggregate) as in sub base complete all as specified. |
| 187 | M&L for 15 mm thick cement plaster in CM 1:4 on walls surface or concrete incl finished surfaces shall be even and smooth without using extra cement complete all as specified. |
| 188 | RCC Pipe 300mm bore dia in class NP-2 laid and jointed complete with collars all as specified and directed. |
| 189 | M&L for loose filling with broken stone or boulder aggregate of gauge 80-150 mm as in filter bed complete all as specified. |
| 190 | M&L for loose filling with broken stone or boulder aggregate of gauge 40 as in filter bed complete all as specified. |
| 191 | M&L for coarse sand filling under floors or in foundations including watering and consolidation. |
| 192 | Precast RCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in cover slab and similar work including necessary formwork set in cm 1:4 complete. |
| 193 | M & L for mild steel bars 10mm dia & over cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, quality confirming to TMT bars. |
| 194 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm complete all as specified. |
| 195 | Removing excavated material exc 250m but not exc 500 m and depositing where directed by Engr-in-charge at a level n.exc 1.5m above the starting point complete all as specified and directed. |
| 196 | S & F of UPVC Pipes (SCH-40), 150 mm dia pipe as in rain water harvesting including fully bend, Tee and 'Y' bend complete all as specified and directed. Total carried over to BOQ Rs. 522498.99 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part IX (LIGHTNING PROTECTION) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 197 | M & L for Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and as directed. |
| 198 | Supply and fixing aluminium strip 25mm x 3.00 mm complete with saddles and fixing screws as roof conductor complete all as specified. |
| 199 | Supply and fixing GI strip 32 mm x 6 mm complete and buried in ground as ground conductor complete all as specified. |
| 200 | Supply and fixing of test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos. 8 mm dia 25 mm long hexa head screw complete all as specified and as directed. |
| 201 | Supply and lay pipe galvanized, \\"light class\\", including fittings 40 mm dia for supporting of air termination rod and protection of GI strip complete all as specified and directed. Total carried over to BOQ Rs. 389084.4 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part X (Fire hydrant and fire alarm system) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 202 | S & F Detectors Complying with and type certified to EN - 45 Addressable multisensor detector with heat and smoke combination with self built intelligence as per IS: 11360 complete all as specified & directed. |
| 203 | S&F addressable type Manual call Point break glass type compatible with main fire alarm control board microprocessor based as per IS-2189 and including chain hammer facility & blinking facility complete all as specified & directed. |
| 204 | S & F Fire Alarm Sounders / Sirens Electronic type horizontal single stage continuous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of + 5 DB complete all as specified & directed. |
| 205 | S & F fire alarm main control panel microprocessor based addressable for 2 wire communication with detectors and addressable response indicators together with mimic diagram made on Auto CAD and pasted on Acrylic sheet with datalogging facility and 2 x 16 character LCD conforming to IS 2189 complete with PA based evacuation system and having its own mains / standby power supply with maintenance free batteries etc. complete all as specified & directed. |
| 206 | S & F Addressable Response indicators having flashing Green LED and Red LED for indication of fire outside each enclosure for pin point location of fire complete all as specified & directed. |
| 207 | S & F for 10 Watt wall mount CD Speaker complete all as specified and as directed |
| 208 | S & F for 500 Watt Amplifier complete all as specified and as directed |
| 209 | S & F for Microphone Set complete all as specified and as directed |
| 210 | S & F for Rigid steel ERW conduit ISI marked heavy duty of size 25 mm dia with necessary heavy duty saddles complete all as specified and as directed. Total carried over to BOQ Rs. 692331.0 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part XI (PVC Conduit for LAN and Telephone) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 211 | Supply and fix Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bellmouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc for CCTV, PA system and sound system: 20 mm dia |
| 212 | Supply and fix Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bellmouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc for CCTV, PA system and sound system: 25 mm dia Total carried over to BOQ Rs. 70865.0 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part XII Site Clearance Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 213 | Surface dressing n exc 15 cm deep and getting out in soft/loose soil all as spd. |
| 214 | Rough excavation not exceeding 1.5 m deep and getting out in soft/loose soil complete all as specified and directed by Engr-in-charge |
| 215 | M&L for Moorum filling in floors or pavings, laid in layers n exc 15cm thick in each layer, spread, levelled and rammed by 8 to 12 ton mechanical power roller including watering, ramming and refilling to complete all as specified and directed by Engr-in-Charge. Note:- Moorum collecting to the out of defence land |
| 216 | M&L for removing excavated material (soil) exc 500m but n.exc 1.5Km and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified. Total carried over to BOQ Rs. 2625882.6 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer |
AI Tender Summary
Tender Timeline
Nov 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 26 daysDec 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 33 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender