Tender For Addition, Alteration, Painting Of Fire Hydrant Pipes, Hose Reel Boxes, Fire Brigade Inlet Boxes, All Fire Pumps, And Carrying Out Repairing Works To Firefighting Systems In Various Buildings At Iit Delhi
Tender Value
34.86 Lakhs
Estimated cost
Bid Submission
23 Nov 2026
2 days left
EMD
69726
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Addition, Alteration, Painting Of Fire Hydrant Pipes, Hose Reel Boxes, Fire Brigade Inlet Boxes, All Fire Pumps, And Carrying Out Repairing Works To Firefighting Systems In Various Buildings At Iit Delhi
BOQ
| Sl. No. | Item Description |
| 1 | Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 Degree C with required accessories. |
| 2 | Pendent Sprinkler |
| 3 | Upright Sprinkler |
| 4 | Supplying, installation, testing & commissioning of intelligent analog addressable photo thermal detector complete with mounting base complete as required. |
| 5 | Supplying, installation, testing &commissioning of intelligent addressable thermal detector with rate of rise cum fixed temperature thermistor complete with base as required. |
| 6 | Supplying, installation, testing & commissioning of addressable strobe complete as required. |
| 7 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 8 | 25 mm dia |
| 9 | 32 mm dia |
| 10 | 40 mm dia |
| 11 | 50 mm dia |
| 12 | 65 mm dia |
| 13 | 80 mm dia |
| 14 | 100 mm dia |
| 15 | 150 mm dia |
| 16 | 200 mm dia (wall thickness 6.3 mm) |
| 17 | 250 mm dia (wall thickness 6.3 mm) |
| 18 | 300 mm dia (wall thickness 7 mm) |
| 19 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipments on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. a) 30 Mtr |
| 20 | Painting with synthetic animal paint of approved brand and manufacture to give an even shade on firefighting pipes, Hydrant boxes, Diesel tanks, Air Vessels, Fire Brigade inlet Boxes, Doors of FHCs, Hose reel Boxes at various locations of IIT Delhi. (One or more coats on old work) |
| 21 | Providing and fixing of damaged/broken addressable MCP glass including testing of MCP after glass replacement etc complete as required. |
| 22 | Supply and fixing of glass fronted cabinet made out of 16SWG M.S. Sheet having single panel glass front door of size (HXLXD) 40''X40''X12'' duly painted with approved shade after application of primer & two or more coats of post office RED paint as required having common lock and key arrangements for all boxes with Take load capacity of 60KG |
| 23 | Supply and fixing of glass fronted cabinet made out of 16SWG M.S. Sheet having single panel glass front door of size (HXLXD) 40''X20''X12'' duly painted with approved shade after application of primer & two or more coats of post office RED paint as required having common lock and key arrangements for all boxes with Take load capacity of 40KG |
| 24 | Providing and fixing of fire hose box glass rubber beading as per site requirement etc as required. |
| 25 | Repairing of leaking fire hydrant pipeline on surface of wall/shaft including cutting, welding of new pipe (length shall be measured as per actual vide sl.No.5) etc complete as required. |
| 26 | Servicing, Overhauling, i/c Replacement of mechanical seal etc. Testing & Commissioning of submersible type Dewatering pump, to & fro transportation etc complete in all respects as per manufacturer's recommendations and site requirements. |
| 27 | 1 HP sump Pump |
| 28 | 2 HP Sump Pump |
| 29 | 3HP Sump Pump |
| 30 | 5 HP Sump Pump |
| 31 | Servicing, Overhauling, shaft reconditioning lathe work i/c Replacement of mechanical seal etc. Testing & Commissioning of Fire pump complete in all respects as per manufacturer’s recommendations and site requirements. |
| 32 | Jockey pump 12.50 hp, |
| 33 | Jockey pump 7.50 hp, |
| 34 | Jockey pump 15 hp , |
| 35 | SITC of Hydrant Valve Hand Wheel (cast iron) complete with fixing arrangement and all necessary accessories, as required at site. |
| 36 | SITC of SS Male & Female Instantaneous Coupling, 63 mm, suitable for fire hydrant system, complete with rubber washer, locking arrangement and all necessary accessories, as required at site. |
| 37 | Servicing of down comer Fire Pump Control Panel and checking of Auto/Manual operation, including replacement of minor components in the control wiring, testing and commissioning of the panel, etc., complete as required. |
| 38 | Servicing of wet riser Fire Pump Control Panel and checking of Auto/Manual operation, including replacement of minor components in the control wiring, testing and commissioning of the panel, etc., complete as required. |
| 39 | Repairing of leaking 80 mm dia. fire hydrant outlet connecting the underground main ring line including cutting of concrete road, excavation of soil to the required length, width and depth, cutting and removal of the damaged portion of pipe, welding of new pipe/portion (upto 1 meter), providing rust-proof bituminous coating, refilling and consolidation of excavated soil, making good the damaged concrete road to match the original finish, and all other incidental works complete as required. |
| 40 | Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS1239/Class -II of IS: 3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (i) 150 mm Dia |
| 41 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. |
| 42 | Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : |
| 43 | Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysNov 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents