Power Government Departments Closing in 10 days TDR #58517239

Tender For Renovation/ Up-Gradation Of Saminar Hall At Amd Office Complex,Begumpet, Hyderabad.

Issued by Government Departments · Hyderabad, Telangana
Tender Value
18.10 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
10 days left
EMD
36210
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Renovation/ Up-Gradation Of Saminar Hall At Amd Office Complex,Begumpet, Hyderabad.

BOQ

Name of Work:- Renovation/ Up-gradation of Saminar Hall at AMD Office Complex,Begumpet, Hyderabad.
Sl. No. Item Description
1General Notes: 1. Contractor shall inspect the site to acquaint with the site conditions as well as security conditions at AMD.2. The rates quoted shall include cost of all tools and tackles, manpower including wages, liveries, all wastages and taxes GST, Labour cess, IT, etc., as applicable but exclusive of EPF and ESI . EPF and ESI are reimbursable as per relevant clause. 3. Tenderers shall visit the site the site on working days and upload site inspection report issued by the Departmental officer with seal and signature which is mandatory document without which the tender will not be considered for evaluation .
2Civil Items
3Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer -in - charge.Nominal concrete 1:4:8 or leaner mix (including equivalent design mix)
4Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
5Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
6Dismantling Skirting/Wall panel/aluminium partition /Floor mats/ Carpets/Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as required, all complete as per the direction of the Engineer-in-charge.
7Brick work with common burnt clay FPS (Non- Modular) bricks of class designation 7.5 in superstructure above plinth level up to floor five level in all shape & size in cement mortar 1:6 (1 cement : 6 coarse sand)
8Providing and laying in position 1:5:10 (1 cement : 5 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 10 graded stone aggregate 40 mm nominal size Recycled Aggregate RA))excluding the cost of centering and shuttering - All work up to up to floor five level as per specification and direction of E-I-C.
9Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) all as per specifications and directions of Engineer-in-Charge
10Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes
11Providing and applying 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand): and providing chicken mesh as the junctions of RCC and brick work wherever requiredas directed by the Engineer-in-charge.
12Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge.
13Providing and laying double charge Vitrified tiles in floor and skirting with 600mm x 600mm size (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints complete as directed by the Engineer-in-charge.(With spacer of 3 mm & epoxy grouting).
14Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) contentWith water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
15Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
16Wall painting with premium acrylic emulsion paint two or more coat, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. The rates also includes preparation of sufaces, filling with putty if required, scaffolding complete as per specifications and as directed by the Engineer-in-charge.
17Providing and Painting two coats of synthetic enamel paint on Steel Surfaces of approved brand and manufacture to give an even shade without primer coat.including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge.
18Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 8 mm GI adjustable rods of min. length 5 with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
19GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation and backed with a black Glass fiber acoustical fleece.
20Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
21Supplying, fabricating and fixing in position 12 mm thick water proof ply of approved make for panelling, storage racks, with the cost of Fevicol, Nails/screws etc and cost of materials, labour, tools & plants, scaffolding etc., all complete as per specifications and directions of Engineer-in-charge. (Area of 12 mm thick water proof ply shall be measured for payment.)
22Providing and fixing premium interior-grade, flexible Polyvinyl Chloride (PVC) fluted decorative sheets of approved brand, shade, and design pattern. The sheets must have min. uniform thickness of 3mm. The surface must feature factory-pressed, anti-reflective 3D grooves/flutes finished with scratch-resistant hot-stamping foil or PUR-bonded film simulating timber wood-grains, solid matte, or metallic textures.The 0.8mm PVC fluted sheets are to be pasted over a pre-installed backing of aluminium frame filled high density rock wool(40-150kg/m3).. The installation must utilize high-strength, premium-grade synthetic rubber/solvent-based adhesives, ensuring uniform bonding without any air bubbles, warping, or edge peeling. The joint lines between adjacent sheets must be perfectly flush, seamless and pattern-matched.(Area of plywood/Aluminium wt. shall be paid in relevent item).
23Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion: Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
24Electrical Items
25Supplying and fixing 6 way (4 + 18), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB /RCCB/Isolator). including cost of materials, labour, tool & plants, taxes etc as per the instructions and directions of E-I-C.
26Supplying and fixing 63A rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.including cost of materials, labour, tool & plants, taxes etc as per the instructions and directions of E-I-C.
27Supplying and fixing 5 A to 32 A rating,Single pole, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. including cost of materials, labour, tool & plants, taxes etc as per the instructions and directions of E-I-C.
28Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. including cost of materials, labour, tool & plants, taxes etc as per the instructions and directions of E-I-C.
29Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS / HFFR PVC insulated copper conductor, single core cable in recessed medium class PVC conduit as required. including cost ofmaterials, labour, tool & plants, taxes etc as per the instructions and directions of E-I-C.
302 X 6 sq. mm + 1 X 6 sq. mm earth wire
312 X 4 sq. mm + 1 X 4 sq. mm earth wire
322 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
332 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
34Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. including cost of materials, labour, tool & plants, taxes etc as per the instructions and directions of E-I-C.
355/6 A switch
3615/16 A switch
373 pin 5/6 A socket outlet
386 pin 15/16 A socket outlet
39Telephone socket outlet
40Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. asrequired. including cost of materials, labour, tool &plants, taxes etc as per the instructions and directions of E-I-C.
416 Module (200mmX75mm)
428 Module (125mmX125mm)
4312 Module (200mmX150mm)
44Supplying, Installation,Testing& Commissioning of 36 Watt LED Panel light 2x2 ft. (System lumen efficacy Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) ≥120 <135 lm/Watt) of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Voltage AC 140-270 Volt, 50/60 hz, Operating temp range -50C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing / Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVCinsulated copper conductor single core cable and earthing etc. as required with Minimum 2 year OEM warranty. Shape size shall be as approved by Engineer-in-Charge as per requirement.
45Supplying, Installation, Testing & Commissioning 30 Watt LED Down lighter (SMD Type) (System lumen efficacy >135lm/Watt) of LED Recessed/surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range - 5 0C to 40 0C,internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initialLumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/ 4000°K /5700°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable andearthing etc. as required with Minimum 2 year OEM warranty. System lumen efficacy >135 lm/Wattoutput. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be asapproved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminiumBody including trim . Shape size shall be as approved by Engineer-in-Charge as per requirement.
46Supplying, installation, Testing & Commissioning of 12-15 Watt LED Recessed/ surface Down lighter (Round/ square/ Rectangular) LED Down lighter (COB Type) (System lumen efficacy ≥105 < 120 lm/Watt ) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt,frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K/ 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximumpower consumption should not more than thespecified rating and Fixture shall be confirming torelevant BIS standards.Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable andearthing etc. as required with Minimum 2 year OEM warranty. System lumen efficacy ≥105 and <120lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shallbe submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink ofaluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector Shape size shall be as approved by Engineer-in-Charge as per requirement.
47Supplying, Installation, Testing & Commissioning of 100 Watt LED Flood Light, powder coated pressure diecast aluminium (System lumen efficacy ≥120 and<135 lm/Watt). Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC,frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as perIEC 61000-4-5, Driver efficiency >85%,THD < 10% 53 DELHI SCHEDULE OF RATES (E&M)-2025 as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 2 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink ofaluminium housing such that LED junctiontemperature shall not rise above 90°C).Shape size shall be as approved by Engineer-in-Charge as per requirement.
48Supplying, Installation,Testing& Commissioning of 30 Watt - 40 Watt LED Panel light 1x4 ft. (System lumen efficacy Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) ≥120 <135 lm/Watt) of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Voltage AC 140-270 Volt, 50/60 hz, Operating temp range -50C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing / Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVCinsulated copper conductor single core cable and earthing etc. as required with Minimum 2 year OEM warranty. Shape size shall be as approved by Engineer-in-Charge as per requirement.
49Removal of existing wiring in Mini Auditorium including removal of incoming cable from Main DB , Old DB Panel, wiring form DB to swicth board , Switch boards, AC points , socket outlets, circuit wiring etc after disconnection of mains and earth connections etc complete. The recess area of DB/ electrical boxes/ switch boards if any available after installing new DB/ switch boards is to be filled with cement concrete, necessary plastering & painting is to be done so as to match with the adjoining areas of wall on all sides, making the good, segregating and stacking the old removed items, including cost of materials, labour, tool & plants, taxes etc as per the instructions and directions of E-I-C.
50Removal of the existing ceiling light fitting installed at a height of 4–5 m after disconnecting the power supply and earthing connections, including dismantling, segregating and stacking the removed materials at the designated location, and all labour, tools and plants (T&P), taxes, and incidental charges, complete as per the instructions and directions of the Engineer-in-Charge (E-I-C).
51Removal of existing fire detector after disconnection of power supply and earth connections etc complete, segregating and stacking the old removed items, including cost of materials, labour, tool & plants, taxes etc as per the instructions and directions of E-I-C.
52Re-installation, fixing, connection, testing, and commissioning of the fire detector (as removed under Item No. 24 and available at site) at the required location, including making power supply and earthing connections, alignment, functional testing with the existing fire alarm system, and making the detector fully operational, complete with all labour, tools & plants (T&P), incidental materials, fasteners, taxes, etc., as per the instructions and directions of the Engineer-in-Charge (E-I-C). Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58517239
AUTHORITY Government Departments
TENDER VALUE 18.10 Lakhs
LAST DATE 25-11-2026
Authority
Authority Name Atomic Minerals Directorate For Exploration And Research
Work Description Tender for Renovation/ Up-Gradation Of Saminar Hall At Amd Office Complex,Begumpet, Hyderabad.
Basic Detail
Tender No AMD/CESG/ET-156/2026-27
Bidding Type Tender
Location
City Hyderabad
State Telangana
Key Dates
Publish Date 13 Nov 2026
Submission Date 25 Nov 2026
Open Date 26 Nov 2026
Finance
Tender Value 18.10 Lakhs
Tender Fee Ref. Documents
EMD 36210
Exemption Not Available
Document List
1a2d5396-ee6c-4cf9-8b56-480b3f3c5b27.html
BOQ_981810.xls
GCC.pdf
Preamble.pdf
specificationcivilworks.pdf
Techforms.xls
Tendernotice_1.pdf
Tendernotice_2.pdf
Undertakings.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Nov 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

1a2d5396-ee6c-4cf9-8b56-480b3f3c5b27.html

xls

BOQ_981810.xls

pdf

GCC.pdf

pdf

Preamble.pdf

pdf

specificationcivilworks.pdf

xls

Techforms.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Undertakings.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender