Tender For Providing Lift Irrigation Scheme To Village Telker,Bharial,Sanahi Kalan And Sanahi Khurd From Kunah Khad In Tehsil Nadaun Distt. Hamirpur(Sh):-Supplying And Errection Of Submersible Pumping Machinery In Booster Stage And Supply Errection O
Tender Overview
Project Description
Tender for Providing Lift Irrigation Scheme To Village Telker,Bharial,Sanahi Kalan And Sanahi Khurd From Kunah Khad In Tehsil Nadaun Distt. Hamirpur(Sh):-Supplying And Errection Of Submersible Pumping Machinery In Booster Stage And Supply Errection Of Centrifugal Pumping Machinery With Allied Accesories Pump House To Mdt.
BOQ
| Sl. No. | Item Description |
| 1 | Submersible pumpset ( Booster stage) |
| 2 | Supply & Errection of horizontal spindle, vertical split casing single/multistages Subminible pumps of Standerd make such as KSB/Kirloskas/WPIL Confirming BIS 8034-1976 (Latest with upto date ammendments) to handle raw water with implellers Casing , ring & shaft sleeves of bronze shaft of steel with Cast iron Casing of suitable Capacity coupled directly through a flexible Coupling on a common base to Kirloskar/NGEF/ crompton/Siemen/ABB/Squirrel Cage screen protected drip proof induction electric motor Suitable for operation on the data given below:- |
| 3 | SITE CONDITIONS:- |
| 4 | Location of site:- Kunah Khad |
| 5 | The altitude of place in which the motor is intended to work in ordinary service.- 450 mtrs. |
| 6 | Humidity:- Humid during rainy season |
| 7 | Nature of atmosphere:- Normal |
| 8 | Detail of quality of water:- Raw water |
| 9 | Water free from sand or not:- Free from sand |
| 10 | Water corrosive or not:- Not corrosive |
| 11 | Turbidity:- upto 500 ppm |
| 12 | Type of well:- Jack well |
| 13 | Inside dia of well:- meter dia. |
| 14 | Depth of water during HFL in the well:- |
| 15 | Maximum draw down:- mtrs. |
| 16 | Depth of well :- 10.00 mtrs. |
| 17 | Any other information if required. |
| 18 | OPERATING CONDITIONS |
| 19 | Type of current:- AC. Three phase |
| 20 | Operating frequency 50 Hz. |
| 21 | Rated voltage 400(+/-) 10% volts. |
| 22 | System of earthing if any to be adopted Double loop earthing as per BIS: 3243-1987 latest with upto date amendments . |
| 23 | Speed of revolutionTo be quoted by tenderer |
| 24 | Direction of rotation To be quoted by tenderer . |
| 25 | No. of working hours per day. 20 hours |
| 26 | The maximum temperature of cooling air and water in the place in which the pump set is intended to work in ordinary service Temperature of place to be specified 20oC to 42oC. |
| 27 | MOTOR |
| 28 | Ref. to BIS code BIS 9283-1979 with upto date amendments |
| 29 | Type of enclosure of motor. As per BIS-4691-1985 (Latest) |
| 30 | Type of duty : Continuous |
| 31 | Mechanical output in KW Suitable for driving submersible pumps required for duties specified against pumps. To avoid over loading of motor a margin of about 15-20% may be kept in the rated output to prime Mover. |
| 32 | Class of insulation Class –B |
| 33 | Max. Permissible temp. Rise of motor reqd. if different from that given in 8 (viii) above.To be specified by the tenderer. |
| 34 | Particulars of test reqd. & where they are to be conducted. AS per terms and conditions attached. |
| 35 | Particulars as to whether voltage limiting device will be employed. Oil immersed star delta starter to be installed between bus bar and motor. Shunt capacitor is also proposed to be installed for improving the power factor at site.Note:- Star delta starter upto 37.5 Kw. |
| 36 | Type of motor Star Delta strater up to 37.5 KW As per BIS 9283-1979 or latest. |
| 37 | Details of shaft extension required |
| 38 | Break way torque in terms of rated load torque and the corresponding break-way starting current which may be taken from the supply with the starting apparatus in circuit should not exceed 2.5 times of the full load current . |
| 39 | Nature of load and any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelerated and No. of starts during a specified period. |
| 40 | Where possible fault capacity of the system to which the motor is connected.The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent deformations. |
| 41 | PUMPS |
| 42 | Nos. of pumps required. 2 No. pumps (Both will run simultaneously) |
| 43 | Spare parts required. For two years normal maintenance as recommended by manufacturer. |
| 44 | Type of drive. Electric induction motor. |
| 45 | Optional fittings required |
| 46 | Pump Operating conditions |
| 47 | Capacity 18.78 LPS for each Pump |
| 48 | Total head in meters 19.95 meter |
| 49 | Static head 17.00 meters |
| 50 | Minimum depth of water Meters |
| 51 | Variation in water level meter |
| 52 | Ground level to Max. water level meter |
| 53 | Ground level to delivery point Meter |
| 54 | Pressure in the suction tank. |
| 55 | Pressure in the delivery tank |
| 56 | Length of rising main 90 meters |
| 57 | Dia of rising main 200 mm dia |
| 58 | Turbidity of water upto 500 PPM |
| 59 | Drive type Electric driven |
| 60 | Limits of total head in which the pump is required to operate. (-) 15% to (+) 10% of total head |
| 61 | Suction/Delivery size of pump |
| 62 | Efficiency of pump at |
| 63 | a) Duty head |
| 64 | b) (+) 10% head. |
| 65 | c) (-) 15 % head. |
| 66 | Material of construction. To be specified by the tenderer (manufacturers certificate to be appended) |
| 67 | Supply of Direct on line of MEI/Kilburn make conforming to BIS 8544-1979 latest with upto date amendments for squirrel cage induction motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release and gas-pots, time legs, under voltage release & initial oil filing of suitable capacity. |
| 68 | Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel board shall be subject to approval of Engineer-in-Charge. |
| 69 | Ammeter AC supply, 100 mm square type auto electric of AE/ L&T Rishab make of suitable capacity for above motor with selector switches conforming to BIS-1248-1983 latest with upto date amendments. |
| 70 | Voltmeter AC supply, 100 mm square type auto electric AE/ L&T Rishab make of 0-500 Volts range for above motor with selector switches conforming to BIS-1248-1983 latest with upto date amendments. |
| 71 | ICTP switches with HRC fuses of Havells/L&T/standard /cromption make for required motor of suitable capacity and conforming to BIS: 4064-1978 latest with upto date amendments. |
| 72 | Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutral conforming to BIS: 8084 –1976 and 11353-1985 read with 5578-1985 all latest with upto date amendmentsof suitable rating. |
| 73 | MCB of suitable capacity of Havells/standard/MDS/Jyoti/Kilburn make to feed motors offered by the tenderer conforming to BIS: 2516-1985 latest with upto date amendments with neutral linked under voltage release. |
| 74 | 3 phase indicator lamps complete with toggle switches for individual motors conforming ti BIS 3452 part I & II latest with up to date amendments of 15 watts. |
| 75 | 50 mm dial Hour run meter of CEE/NEE make of suitable range as per relevant BIS specifications. |
| 76 | Supply of Kirloskar/leader make dia. cast iron class PN. 1.0 double flanged sluice valve having size one dia. Higher than pump size to delivery of pump and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS :780-1984 (Part I) |
| 77 | Supply of Kirloskar/leader make dia. cast iron (class PN. 1.0) double flanged ( swing check type) reflux valve having bye pass arrangement and having one dia. Higher than pump size to delivery of pump and capable of withstanding nominal seat pressure of 10.2 kg/cm2 as per BIS-5312-1984.(Part-I). |
| 78 | Supply of Leader /Kirloskar make 200 mm dia. cast iron class PN. 1.0double flanged (swing check type) reflux valve having bye pass arrangement and size equal to dia of rising i.e. 250 mm for withstanding nominal seat pressure of 10.2 Kg/Cm 2 as per BIS 5312-1984 (Part-I ) |
| 79 | Supply of PVC joint less flat water proof cable as per BIS: 694-1990 latest with upto date amendments suitable for the pump sets offered from MCB to motor including all other electrical equipment/accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced by tender. |
| 80 | Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of required capacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and other electrical equipment’s. |
| 81 | Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to BIS: 3624-1987 latest with upto date amendments. |
| 82 | Providing and laying delivery pipe . and common header 200 mm dia GMSERW jointed with MS flanges of table-17 as per IS: 6392-1971 (upto a length of 20 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses as per layout drawings approved by Engineer-in-Charge. |
| 83 | Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments Baja/L&T/Asian/cromption make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of siemens/Gloster/ICC make form bus bar chamber to capacitor and also including L&T/LK/Kilburn make ICTP switches conforming to BIS –4064-1978 or latest with HRC fuses (range to be specified by the tendrerer). |
| 84 | Supply of suitable cable for water level guard |
| 85 | Supply of supporting clamps. |
| 86 | Supply of cable clips of required size. |
| 87 | Erection of all equipment from Sen. 1 to 4,6,7,9 ,11 & 14 including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge. |
| 88 | Centrifugal pumping set (1st stage) |
| 89 | Supply ,Installation ,Testing & Commissioning of energy efficient horizontal spindle, horizontal/ radial split casing/end suctions (back pull out arrangement)single/double/multistage centrifugal pump suitable for operation, in parallel of recommended make such as Mather and platt/KSB/Kirloskar/Jyoti /Beaconweir confirming to BIS-1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting over Raw water for under mentioned characteristics with bronze/Bronze with 2.5% Nickel impellers, dia of 405mm priming funnels, casing ring and shaft sleeves of bronze/ steel, shaft of SS:410/AIS 1431 Chrom in plated with cast iron casing coupled directly through a flexible coupling on a Common MS base plate to squirrel cage induction motor TEFC type energy efficient minimum IE2 compliance conforming to IS:- 12615-2018 of standard make such as Kirloskar/BHEL/ Crompton/NGEF/GEC/Siemens/ Jyoti/ ABB/Marathon and suitable for operation on LT, 50 cycles/second 3 phase AC electric supply. The pump set should include water level guards, erection clamps , cables , depth gauge, double loop earthing, NRV, common header,Sluice valves and actuated valves of approved class including errection charges etc. The power of electric motor/motors should be at least (+) 10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-) 15% of the duty point head. The motor/motors should be as per IS: 325-1978 with upto date amendments read with IS:900-1972. The starting current of the motor shall be limited to not more than 4.5 to 5 times of full load current pumping set complete I/C allied acessories. |
| 90 | read with IS: 900-1972. It should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements:- |
| 91 | Discahrge (Q) : -Total 18.782 LPS |
| 92 | Total dynamic head : 143.04 Mtr. |
| 93 | (a) LWL in sump well (h) :529.00 Mtrs. |
| 94 | (b) Shaft level : 527 Mrs |
| 95 | (c ) Level at discahrge point :640 Mtrs. |
| 96 | (d) Suction lift :0.00 Mrtrs |
| 97 | (e) Residual head :3.00 Mtrs. |
| 98 | (f) Static head : 104 Mtrs. |
| 99 | (i) Rising Main : |
| 100 | (a) Length 2760 Mtrs. |
| 101 | (b) Dia. :200 mm |
| 102 | (iv) Pumping Hours : 20 Hours |
| 103 | (v) Altitude of installation above MSL : 500 |
| 104 | (vi) Characteristics of water : |
| 105 | (a) Temperature : 20.00 0 C |
| 106 | (b) Ambient temperature 42 Oc |
| 107 | (c ) Turbidity upto 500 NTU |
| 108 | (d) Alkalinity MG/CA CO3 |
| 109 | (e) Size of the solids mm |
| 110 | (f) Other |
| 111 | Providing ICTP Main Switch with HRC fuses/Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064-1978 with up to date amendments immediately after the power meter of HPSEB |
| 112 | Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:- |
| 113 | M.C.B. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516-1985 with up to date amendments with. |
| 114 | E.L.C.B. of Havell/MDS/INDETEC make as per IS: 2516-1977 with upto date amendment which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. |
| 115 | The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 3842 ( Latest edition). |
| 116 | 100mm square type A.C. supply voltmeter of AE/L&T Rishab make of suitable range with selector switches as per IS: 4064-1978 with up to date amendments. |
| 117 | Power factor meter of AE/L&T Rishab make as per relevant IS codes with up to date amendments of suitable rating. |
| 118 | Frequency meter of AE/ L&T Rishab make as per relevant IS: Codes with up to date amendments of suitable rating. |
| 119 | Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11353-1985 read with BIS 5578-1985 with up to date amendments 63 Amp. |
| 120 | ICTP switches with HRC fuses of L&T/ Standard/Havells make and of suitable capacity as per IS: 4064-1978 with up to date amendments. |
| 121 | Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I&II) with up to date amendments. |
| 122 | 100mm Square type AC supply Ammeter of AE /L&T Rishab make of suitable range with selector switches and CTS operated as per IS:1248 (P-II) 1983 with up to date amendments. |
| 123 | Capacitor of L&T/Bajaj/Assian/Crompton make as per IS:2834-1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVAR rating according to HP offered including cables as per relevant ISI code ( of Siemens/Glocter/IEC make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064-1978 with upto date amendments |
| 124 | Providing suitable Star delta starter of MEI/Kilburn make as per IS: 8544-1979 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments. |
| 125 | Providing Hour run meter of recommended make of suitable capacity as per IS: 722 (Latest edition) |
| 126 | Providing double flanged Cast iron sluice valve of Leader/Kirloskar make of 200 mm dia for the suction pipe and capable of withstanding the normal seat pressure 16.32kg/cm as per IS: 780-1984 class PN 1.6 with upto date ammendments. |
| 127 | Providing double flanged Cast iron sluice valve of Leader/Kirloskar make and size one dia. higher than pump for the delivery line of the pump and capable of with standing the normal seat pressure 16.32kg/cm as per IS: 780-1984 class PN 1.6 with upto date ammendments. |
| 128 | Providing double flanged (Swing type) CastSteel reflux valve of Leader/Kirloskar make and one dia. higher than pump having bye pass arrangement on the delivery line of pump and capable of with standing normal seat pressure 16.32 Kg/cm2 as per IS: 5312-1984 class PN. 1.6 with uptop date ammendments. |
| 129 | Providing double flanged Cast steel non return valve of Leader/ Kirloskar make and of 200 mm dia. having bye pass arrangement for rising main and capable of with standing normal seat pressure 16.32 Kg/cm2 as per IS: 5312-1984 class PN. 1.6 with uptop date ammendments. |
| 130 | Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0-52 Kg/cm2 |
| 131 | Installation of all the items appearing at Serial No. 1 to 8 as per the systematic drawing attached with the tender documents. |
| 132 | Providing and fixing double flanged GMSRW . piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1. |
| 133 | The size of the various components to be as under:- (i) Suction pipe As per site Requirement (ii) Delivery pipe As per site Requirement (iii) Common Header As per site Requirement And will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed. |
| 134 | Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/GICO/Grandly/National make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. Motor side: Suitable size cable Min length = 20 mtrs. Supply side: Suitable size cable Min. length =10 mtrs. |
| 135 | Providing and fixing double loop earthing and G.I. plate 600mmx600mmx3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx6mm G.I. strips & G.I. wire as per IS: 3043-1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender