Tender For Providing And Installation Of New Tubwell Size 200Mm I/D, 195Mtr Depth, With Reverse Rotary Rig And Providing, Fixing And Jointing Of Pvc Pipe, Ci/Di Flanged End, Construction Of Sluice Valve Chamber, Chemical Dosing Chlorinator, Testing A
Tender Overview
Project Description
Tender for Providing And Installation Of New Tubwell Size 200Mm I/D, 195Mtr Depth, With Reverse Rotary Rig And Providing, Fixing And Jointing Of Pvc Pipe, Ci/Di Flanged End, Construction Of Sluice Valve Chamber, Chemical Dosing Chlorinator, Testing And Commissioning Of Pumping Machinery In The Place Of Failed Tubewell, At Existing W/S Scheme Sotal Baba Block Morinda, District Rupnagar (Under 4215)
BOQ
| Sl. No. | Item Description |
| 1 | Tubewell |
| 2 | Drilling of 500mm dia bore with Reverse Rotatry Rig in all kinds of soil including the cost of consumable stores, fuel oil and transportation of rig to the site. complete in all respect. |
| 3 | Drilling of 500mm dia bore with Reverse Rotatry Rig Upto 150 m depth BGL. |
| 4 | Drilling of 500mm dia bore with Reverse Rotatry Rig Beyond 150 m depth BGL up to 300 Mtr |
| 5 | Drilling of test bore hole including the rate for logging (Electric logging shall be carried out by Contractor upto full depth) to be paid only for the drilling depth beyond the bail plug margin or the tubewell is abandoned.1. Eraction and dismantling of boring plant including all arrangment for the transportation of the boring equitment to site of work from the store of the contractor at site and back are to be made by the contractor at his own cost. all rates should be quated for supplying the material at site of work. pits for collection of water and water for drilling tubewell to be arranged by the firm/contractor at site at his own cost. 2. in case the bore is converted into a tube well payment of bore shall be made up to the bail plug margin(7% of main bore drilling or as actual as per fiel requirmwnt whichever is less) required for sustaining the main bore. the test bore beyond margin shall be paid at the rate of test bore drilling. |
| 6 | Making electric Logging of borehole with electronic well logger including cost of equipment at site etc.complete in all respect |
| 7 | Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore. |
| 8 | 200mm nominal diameter (weight 41.6 kg per metre) 8.00 mm thickness |
| 9 | Supplying, Fixing & lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell respects. |
| 10 | 200mm Steel Strainer (slot size 0.75mm) 8.00 mm thickness |
| 11 | Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect. |
| 12 | 200mm internal diameter |
| 13 | Supplying, Fixing & lowering of Stainless Steel Socket as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell bore complete in all Respect. |
| 14 | 200mm internal diameter |
| 15 | Supplying & Fixing of bail plug of M.S pipe complete with inverted U-hook attched to the bottom plug complete in all respect. |
| 16 | 200mm internal diameter (weight 41.6 kg per metre) 8.0 mm thickness |
| 17 | Supplying and fixing well cap having thread to fix on housing pipe. Complete in all respects. |
| 18 | 200mm internal diameter |
| 19 | Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect. |
| 20 | Supplying at site Wooden Box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore. |
| 21 | Supplying at site of gravel of 1/16\\" to 1/8\\" sizes including pouring and packing in the annular space between the pipes assembly and the bore.The gravel should be free from, dust,dirt, or the vegetable manner as per IS 4097/1967 with latest amendments .(to be paid as per actual length of pipe) |
| 22 | The rates including loading & unloading charges. |
| 23 | Supplying & fixing mild steel centering guides made out of 32mm x 6mm thick M.S. bar complete in all respects. |
| 24 | (a) Strainer & MS pipe should be properly jointed with sockets and duly welded to ensure maximum strength of joint. |
| 25 | (b) A steel strip of suitable size should be welded across the length of strainer to provide additional strength to the tubewell assembley. |
| 26 | Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide & Urenium etc.) |
| 27 | Development and Stabilizing of the tubewell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. |
| 28 | Capacity of Air compressor 550 cfm at 600 PSI |
| 29 | Development and Stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. |
| 30 | Collection of water sample from different strata and testing of sample from approved laboratory |
| 31 | Supplying at site Tibba sand etc. including pouring and packing in the annular space between the pipes assembly and the bore above clay seal complete in all respect. |
| 32 | Providing & Fixing Sanitery Seal (As per IS:2800-2019) |
| 33 | Provision for Sterilisation of tubewell with sodium hypochorlide/chlorination of well as per IS code 2800: 2019 complete job. The well shall be disinfected or sterilized as per IS code 2800:2019 or latest, after the development by pump and before the final test. All wells regardless of the use should be sterilized on completion to prevent or retard the growth of corrosion or incrustation fostering organisms. This should be done by introducing chlorine into the water in the well and immediate aquifer surrounding the well .The volume of water in the screen and casing should be estimated and sufficient chlorine added to yield for water with chlorination of 1000 ppm. The solution should be poured into the well and thoroughly mixed in the well by surging with pump. The solution should remain in the well for at leaset 6 hours during which it should be surged at about 2 h interval. After expiration of contact time , the well should be pumped initially back into the well for abour 30 minute and late to waste until there is little of no odour or taste of chlorine in the discharged water . IT has been found that using hypochlorite is of 10% concentration, the requirement of hypochlorite is 10 litre for every cubic meter of water in the well to produce. |
| 34 | Providing & Fixing Clay seal in graval pack minimum 3 Mtr. (As per IS: 2800-2019) |
| 35 | RISING MAIN |
| 36 | Providing, Laying, fixing & jointing of PVC pipes as per ISI-4985 (ISI marked with prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including excavation & back filling as per analysis A 14 complete in all respects. |
| 37 | 110mm o/d PVC Pipe of 10kg/Sqm2 |
| 38 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) |
| 39 | 150 mm I/d |
| 40 | Providing, Fixing & jointing Cast Iron Surface box for Sluice Valve, Air Valve, Fire hydrant etc. including all carriages complete @ 33Kg Each |
| 41 | Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department (size 0.9m x 0.9m) |
| 42 | Chlorinator |
| 43 | Prov. Installing, testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator ,suitable for delivering 0.5 to 6 Litres of Bleaching Powder Solution/Sodium Hypo solution per hour under maximum delivery pressure up to 7 Kg.cm2, and suction lift not less than 1.5 m, as per DWSS. standard specifications. |
| 44 | PUMPING MACHINERY |
| 45 | Providing, installing, testing and commissioning of 1 no. 15 BHP electrically driven pumping set of reputed make Complete in all respects |
| 46 | PVC INSULATED FR COPPER CONDUCTOR CABLES:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 47 | Overall size 4.0sq.mm (56/0.3mm), 3Core |
| 48 | Construction of Gravel Pit outside the Pump Chamber. (0.90m Dia.) as per standard design & drawings of public health department. |
| 49 | Providing and installing 100 mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects |
| 50 | Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) B- Class, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. |
| 51 | 80mm i/d Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender