Educational and Research Institute Government Departments Closing in 8 days TDR #58516580

Tender For Round The Clock Service For annual maintenance contract Of 11 Kv Substation And Attending Day To Day Complaints In All Electrical Installation And Minor Project Works In Iitm Discovery Campus At Thaiyur For The Period From 01-02-2027 To 31

Issued by Government Departments · Chennai, Tamil Nadu
Tender Value
53.82 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
8 days left
EMD
1.07 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Round The Clock Service For annual maintenance contract Of 11 Kv Substation And Attending Day To Day Complaints In All Electrical Installation And Minor Project Works In Iitm Discovery Campus At Thaiyur For The Period From 01-02-2027 To 31-03-2028

BOQ

Name of Work:- Round the clock service for AMC of 11 KV Substation and attending day to day complaints in all electrical installation and minor project works in IITM Discovery Campus at Thaiyur for the period from 01-02-2027 to 31-03-2028
Sl. No. Item Description
1Attending day to day maintenance of HT/ LT equipments, break down work, fuse of calls, emergency faults, major break down inside the entire campus including street lights on round the clock service on shift duty work with the following designated staff. (Shift Duty: 3 shifts/day)1 No Supervisor cum Electrician with valid C License and 1 No helper in each shift and total three shifts in a day. The Supervisor cum Electrician and helper should have minimum three years experience in O & M of Substations up to 11 kV Supply System . Shift Duty time: 6 am to 2 pm & 2pm to 10 pm & 10 pm to 6.00 am.(For all days incuding govement holidays).
2Supplying of following accessories for replacement in item no.1 and when required during the contract period.
360W LED fitting DC Drive( XO75C070V107FNYIB0 OR EQUIVALENT IN Aspproved make)
4Surge protectors for LED fittings ( SRPSQ-10kV/5kA-440 10kV OR EQUIVALENT IN approved make)
5Modular GI box for 2 module
6Modular GI box for 4 module
7Modular GI box for 6 module
8Modular GI box for 8 module
9S.P. 5/6 A, one way modular switch, ISI marked
10S.P. 15/16 A, one way modular switch, ISI marked
113 pin 5/6 A modular socket outlet, ISI marked
126 pin 15/16 A modular socket outlet, ISI marked
13Stepped type Modular Fan regulator (2 module)
14Modular base & cover plate for 1/2 module
15Modular base & cover plate for 6 module
16Modular base & cover plate for 8 module
17Modular base & cover plate for 12 module
18Supply of 36 watt LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120lm/Watt) of owder-coated die-castPowder coated die cast /Extruded aluminium Bod
19Supply of 36 watt LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
20Modular timer switches Maxi Rex 4QTB of Legrand or Eqvt in L&T and GE.
2140A TP power contactor
22Supplying& Laying of following sizes PVC XLPE insulated alu. Conductor armored 1100V LTUG cable in a 50 mm to 100 mm dia HDPE DWC pipe in a trench of 50cm wide and 75cm depth including earth work excavation in all soils and sub soils and back filling, consolidated in a regular interval of 25cm thick rammed and complying with standard specification.cable identification on both side with aluminium cable tags.
234C x 10 sq.mm XLPE insulated armoured aluminium cable.
243.5c x 16 sq.mm XLPE insulated armoured aluminium cable.
253.5c x 35 sq.mm XLPE insulated armoured aluminium cable.
263.5 x 70 sq.mm XLPE insulated armoured aluminium cable
273.5c x 150 sq.mm XLPE insulated armoured aluminium cable
283.5c x 240 sq.mm XLPE insulated armoured aluminium cable.
293.5c x 400 sq.mm XLPE insulated armoured aluminium cable
30Supplying and making end termination for following sizes alu. Conductor LT UG cable using suitable compression gland with required copper ferulles / socket and other jointing materials
314c x 10 sq.mm
324c x 16 sq.mm
333.5c x 35 sq.mm
343.5c x 70 sq.mm
353.5c x 150 sq.mm
363.5c x 240 sq.mm
373.5c x 400 sq.mm
38Providing and fixing following of rating and breaking capacity MCCB in the existing cubicle panel board including drilling holes in cubicle panel, making connections, etc as required.
3916 kA,150 amperes 3 pole MCCB
4036 kA,125 amperes 4 pole MCCB
4136kA, 250A amperes 4 pole MCCB
42Supplying & fixing of following ratings, miniature circuit breaker in the existing MCB/MCCB DB's complete with connections, testing and commissioning etc as required
436 - 32 Amperes Single pole MCB
446 to 32 Amperes double pole MCB
456 to 32 Amperes triple pole MCB
466 to 32 Amperes Triple Pole and Neutral MCB
47Supplying and fixing DP sheet steel enclousre on surface /recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc.as required.
48Supplying and fixing of following sheet steel enclousre on surface / recess along with following rating of \\"c\\" curve MCB complete with connections, testing and commissioning etc.as required.
4916/25/32 A 415 V \\"c\\" curve TP MCB with Enclosure
5040A Four pole MCB with Enclosure
5163A four pole MCB with Enclosure
52100A Four pole MCB with Enclosure
53Supplying and fixing 8 way (4+24) three phase and neutral (VTPN double door type).company made sheet steel, MCB distribution board, 240V or 415 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc as required. ( without MCB/ RCCB/ Isolator).
54Supplying and fixing 4 way (4+12) three phase and neutral (VTPN double door type).company made sheet steel, MCCB distribution board, 240V or 415 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder-painted, including earthing etc as required. ( without MCB/ RCCB/ Isolator).
55Supplying and making straight thro cable joint for following sizes aluminium or copper Conductor LT UG cable using Heat Shrinkable /cast resin materials ( M-Seal-3M or RPG) with required copper ferulles / socket and other jointing materials.
563.5 core 35 sq.mm ( cast resin)
573.5 core 70 sq.mm ( Heat Shrinkable)
583.5 core 150 sq.mm ( Heat Shrinkable)
593.5 core 240 sq.mm ( Heat Shrinkable)
603.5 core 300/ 400 sq.mm ( Heat Shrinkable)
61Supply and fixing of 72W Street light LED fitting complete set with built in Drive. (approved make)
62SITC of 100w Flood light LED fitting complete set with built in Drive.( approved make)
63Supply and fixing of LED Batten light (System lumen efficacy ≥120 85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching)
6424-26 watt
65SITC of 18W LED Surface / Recessed mounting fitting complete set. Square or Round in Approved make
66Supply and fixing of streetlight PVC control box of 200x150x100mm size with suitable clamp with hylem sheet inside comprising 63A 4 way connector and a 10A SP MCB with necessay connections.
67Point wiring in PVC conduit, with modular type switch/regulator wiring for light point/ fan point/ exhaust fan point/ call bell point/ 6 amps switched socket with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable GI / PVC box, ceiling rose, round block and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required and instructed by the engineer incharge.1.10.3 Group C
68Supplying and fixing of following modular switch/ socket on a modular plate & G I /PVC switch box including connections as required
696 amps. socket controlled by 6 amps. one way switch.
706/16 amps. socket controlled by 16 amps. one way switch.
71Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface /recessed medium class PVC conduit as required.
722 runs of 1.5 sq.mm and 1 run of 1.5 sqmm cable.
732 runs of 2.5 sq.mm and 1 run of 2.5 sqmm cable.
742 runs of 4.0 sq.mm and 1 run of 4 sq.mm cable.
752 runs of 6 sq.mm and 1 run of 6 sq.mm earth wire
762 runs of 10 sq.mm and 1 run of 6 sq.mm earthwire
77Supplying, installing, testing and commissioning of 1200 mm sweep super efficient BLDC / Orient PSPO ceiling fan with 3 leaf , 5 speed completely pre wired up to the terminal block complete as required.The sample to be got approved before procurement.
78Supplying and installation of Heavy Duty 300 mm sweep exhaust fan exhaust fans with metal blade and louvers/ shutters in the existing opening and making connections and testing, commissioning etc as required.
79SITC of Earthing with copper earth plate 600x600x3mmthick including acessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7m long etc with charcoal/coke and salt as required.
80SITC of Earthing with GI earth plate 600x600x6 mmthick including acessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7m long etc with charcoal/coke and salt as required.
81SITC of Chemical Earthing -copper bonded solid rod 25mm dia earth electrode with ,3 metre length with 50Kg high conductive earthing compound including all acessories and providing HDPE round earth pit chamber and cover (300MMx350MM) with cover plate having locking arrangement as instructed by engineer incharge.(make: cikit,infinite, Ashlok).
82Supplying and laying of following size earth flats at 0.50 mt below the earth including soldering/welding as required
83Single run of 16 sqmm multistranted copper wire in a suitable PVC pipe and clamps
8425 x 5mm copper flat
8525 x 5mm GI flat
8650 x 6 mm GI Flat
87Supplying and replacing of 220V AC indication LED lamps as instructed by the Engineer incharge.
88Testing of earth electrodes using necessary testing equipment and improve the earth by excavating the soil and sub soil and refilling the same with alternate layer of charcoal/coke and salt if required. The values are to be entered in a seperate register and submitted to the Engineer incharge . The work should be inclusive of replacement of bolts and nuts, white washing the masonary pedastals , paint marking the earth values, date of testing done , due date for the next test and pit number on the enclosures and also inside the earth pit.
89Supplying and replacing of silica Gel for the Power/ Distribution transformer breathers
90Supplying and replacing of mineral oil suitable Power/ Distribution transformer as per IS 335/1993
91Removing the following sizes LT UG cable of size up to 3.5c x400 sq.mm from the existing trench of 75cm depth including earth work excavation in all soils and sub soils for identifying the faults and relaying the same cable / other cable in the trench, sand filling and brick cover protection of the cable using existing burnt bricks/ removed RCC troughs etc and back filling. consolidated etc as required.
92DG Set
93Supply and Replacement of all required acessories (including all filters, except Air filter) for B-check as per the DG manufacturer/OEM recommendations.
94250kVA DG Set (without lube oil)
95500kVA DG Set (without lube oil)
96Diesel Engine oil as per the manufacturer recommendations
97Charges for filling of high speed Diesel (diesel will be supplied by IIT Madras) to the DG sets at various locations in the premises by manualy or electricaly including neacessary labour and hire charges for vehicle for transoport from nearby pertrol bunk as and when required as instructed by the Engineer- Incharge. ( 1 job will be considered as a trip from nearest petrol bunk to DG location at IITM discovery campus) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58516580
AUTHORITY Government Departments
TENDER VALUE 53.82 Lakhs
LAST DATE 25-11-2026
Authority
Authority Name Indian Institute Of Technology
Work Description Tender for Round The Clock Service For annual maintenance contract Of 11 Kv Substation And Attending Day To Day Complaints In All Electrical Installation And Minor Project Works In Iitm Discovery Campus At Thaiyur For The Period From 01-02-2027 To 31-03-2028
Basic Detail
Tender No 12/2026-27/ELDB
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 13 Nov 2026
Submission Date 25 Nov 2026
Open Date 26 Nov 2026
Finance
Tender Value 53.82 Lakhs
Tender Fee Ref. Documents
EMD 1.07 Lakhs
Exemption Not Available
Document List
b3f5ec29-ae36-4c2d-9243-e14fb2c6e81b.html
BOQ_346918.xls
PriceBidForViewT12.pdf
TenderNoT12.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Nov 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

b3f5ec29-ae36-4c2d-9243-e14fb2c6e81b.html

xls

BOQ_346918.xls

pdf

PriceBidForViewT12.pdf

pdf

TenderNoT12.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender