Public Administrative Department Government Departments Closing in 0 days TDR #58516558

Tender For Providing And Laying Pipeline For Integration Of Pond Near Permanent Shelter,Vijay Nagar To 12.00 Km Wtp At Vijay Nagar,Campbell Bay Including Pump Set.

Issued by Government Departments · Nicobars, Andaman And Nicobar Islands
Tender Value
1.21 Crore
Estimated cost
Bid Submission
26 Nov 2026
0 days left
EMD
2.42 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nicobars → Andaman And Nicobar Islands
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing And Laying Pipeline For Integration Of Pond Near Permanent Shelter,Vijay Nagar To 12.00 Km Wtp At Vijay Nagar,Campbell Bay Including Pump Set.

BOQ

Name of Work:- Providing and Laying pipeline for integration of Pond near Permanent Shelter,Vijay Nagar to 12.00 km WTP at Vijay Nagar,Campbell bay including Pump set.
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing ofsides and ramming of bottoms, forall lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, withina lead of 50 m.
2All kinds of soil.
3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up toplinth level:
41:3:6 (1 Cement: 3 coarse sand (zone-III) derived from natural sources:6 gradedstoneaggregate40 mm nominal size derived from natural sources)
51:4:8 (1 Cement:4 coarse sand (zone-III) derived from natural sources:8 gradedstoneaggregate40 mm nominal size derived from natural sources)
6Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain windowsills, fillets, sunken floor etc., up to floor five level, excluding the cost ofcentering, shuttering and finishing:
71:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources:6 gradedstoneaggregate 20 mm nominal size derived from natural sources)
8Centering and shuttering including strutting, propping etc. and removal ofform for
9Foundations, footings, bases of columns, etc. for mass concrete
10Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
11Hot finished welded type tubes
12Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand:4 graded stone aggregate) finished witha floating coat of neat cement, including cementslurry, but excluding the cost ofnosing ofsteps etc. complete.
1340 mm thick with 20 mm nominal size stone aggregate
14Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm asperIS: 277, in 240 mpa steel grade, 5-7 microns epoxyprimeron both sideofthe sheetand polyestertop coat 15-18 microns. Sheetshould have protective guard film of 25 microns minimum toavoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /seIf tapping screws ofsize (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shapewherever required.
15Providing and fixing precoated galvanised steel sheetroofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram persqm asperIS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete:
16Ridges plain (500 - 600mm)
17Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade
18Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
19Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
20Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
21Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. External work
22PN - 10 Pipe, 90 mm OD (SDR-11)
23Providing and fixing PP-R Unions.
24PPR Union 90mm
25Providing and fixing PPR Gate Valve of approved quality :
2690 mm nominal bore
27Extra for providing and fixing flat Aluminium wind ties of 40x6 mm. flat Aluminium section with necessary etc., complete.
28Supplying, Installation, Testing and commissioning of Kirloskar or equivalent make 16 HP, TV2 Diesel Engine coupled with Kirloskar or equivalent make 16SR6 Pump @ 1800 RPM, water cooled, having discharge of 6.0–9.0 Ltr/Sec, head 80–90 mtrs, suction & delivery of 80 × 65 mm, with base frame for Engine & pump with foundation nut & bolt, coupling arrangement, Normax foot valve 80 mm dia with suction and delivery flange, fuel tank of suitable capacity, GI fitting for silencer etc. as required and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58516558
AUTHORITY Government Departments
TENDER VALUE 1.21 Crore
LAST DATE 26-11-2026
Authority
Authority Name Andaman Public Works Dept
Work Description Tender for Providing And Laying Pipeline For Integration Of Pond Near Permanent Shelter,Vijay Nagar To 12.00 Km Wtp At Vijay Nagar,Campbell Bay Including Pump Set.
Basic Detail
Tender No 36/EE/CD/CB/2026-27
Bidding Type Tender
Location
City Nicobars
State Andaman And Nicobar Islands
Key Dates
Publish Date 13 Nov 2026
Submission Date 26 Nov 2026
Open Date 27 Nov 2026
Finance
Tender Value 1.21 Crore
Tender Fee Ref. Documents
EMD 2.42 Lakhs
Exemption Not Available
Document List
16a7d007-7bdd-4c35-8ed5-fc4e5e26232f.html
BOQ_27464.xls
Instructions-to-bidders.pdf
Tenderdocument36.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Nov 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

16a7d007-7bdd-4c35-8ed5-fc4e5e26232f.html

xls

BOQ_27464.xls

pdf

Instructions-to-bidders.pdf

pdf

Tenderdocument36.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender