Tender For Construction Of Auditorium ( Capacity 495 Seats) At School Of Eminence Nangal (Distt) Rupnagar. (Electrical External Services) (Providing For Security/Campus Lighting And 160 Kva D.G. Set)
Tender Value
27.47 Lakhs
Estimated cost
Bid Submission
27 Nov 2026
10 days left
EMD
54948
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Auditorium ( Capacity 495 Seats) At School Of Eminence Nangal (Distt) Rupnagar. (Electrical External Services) (Providing For Security/Campus Lighting And 160 Kva D.G. Set)
BOQ
| Sl. No. | Item Description |
| 1 | Provision for Security/Campus LightingPVC INSULATED FR COPPER CONDUCTOR CABLES:Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 2 | Overall size 1.5sq.mm (48/0.20mm), 3Core |
| 3 | XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- |
| 4 | Overall size 10sq.mm (3Core) Un-armoured (On-Surface) |
| 5 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 6 | Overall size 10sq.mm (2Core) Un-armoured (Loose) |
| 7 | GALVANIZED IRON PIPES AND G.I. EARTHING Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be erected in ground upto complete length vertically:- |
| 8 | GI Earth rod 20 mm dia., 3 mtr. Long |
| 9 | AUTOMATIC VOLTAGE STABLIZER, TIMER: S/E of Microprocessor Based Street Light Controller with digital time switch daily programmed with stand by lithium battery with back up of 6 years with min. time between 2 switching operations is 1 minute, three pole power contactors 40A. with coil voltage 220-230V AC with 1 no. aux. contact NO, MCB 2 pole 40amp. (C-Curve, 10kA) & power wiring with single core PVC insulated FR cable 10 sq. mm and control wiring with PVC insulated FR cable 1 sq. mm, 1 no. two position selector switch to bypass timer and other accessories & petty material (din rail, 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) should be fixed on bakelite sheet 6mm thick to be mounted in a IP54 surface/ flush mounting powder coated sheet metal (1.60mm thick) cabinet having size 450mm x 600mm x 150mm to switch ‘ON’ all the 3 phases & switch ‘OFF’ 3 phases pre-fixed timings complete in all respect as per satisfaction of Engineer-in-charge:- |
| 10 | Street Light Controller (For Single Phase Circuit) with 1 No. Three Pole Power Contactor 40A, 1 No. MCB 2 Pole 40amp. (C-Curve,10kA) & petty material (Din rail, 1 No. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) |
| 11 | GI PIPE POLES & BRACKETS:Supply and erection of G.I. pipe ‘A’ quality of suitable length and dia. confirming to IS:1239 (Part-I) 1979, including fixing up to a given depth below G/L, the hole of excavation about 30cm dia. and given depth to be filled in up to 15cm below G/L with 1:2:4 cement concrete including painting of pole with two coats of approved aluminium paint as required:- |
| 12 | G.I. Pipe Pole 4 metre Long, Dia. 65mm, Planting Depth 80cm with Pit Depth 95cm. |
| 13 | CEMENT CONCRETE MUFFS:Making of cement concrete muff of overall size 450mmdia., suitable length (15cm below ground level) with 1:2:4 cement concrete mixture. The muff is to be made around the steel tubular pole/ GI pipe pole. The outer surface of the muff shall be finished with 1:2 cement plaster with two coats of white snowcem complete in all respect as approved and desired by the Engineer in-Charge at site:- |
| 14 | Cement Concrete Muff of Overall Size 450mm dia., 60cm long |
| 15 | LAYING OF UNDER GROUND CABLES, DISMANTALLING & ERECTION OF POLES AND CEMENT CONCRETE MUFFS:Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:- |
| 16 | SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 140mm x 140mm x 95mm with hinged water tight cover with locking arrangement |
| 17 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 18 | Double walled corrugated (DWC) HDPE pipe 50 / 38mm (outer/inner dia.) |
| 19 | Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- |
| 20 | Aluminium thimble cable Core size 10 - 16sq.mm |
| 21 | Supply and Erection of LED Post top 40/45 watt Opal Diffuser Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. |
| 22 | Supply and erection of LED Flood Light 120watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. |
| 23 | Provision for Diesel Generating Set 160KVA PVC INSULATED FR COPPER CONDUCTOR CABLES:Supply and erection of XLPE/ PVC insulated PVC sheathed (10 core) unarmoured copper conductor cable (ISI marked) confirm to IS:7098 (PART-I), 1988 loose in the existing trench or pipe with suitable size of copper thimbles/ lugs complete in all respect as desired by the Engineer-in-charge:- |
| 24 | Overall size 2.5sq.mm (10 Core) |
| 25 | XLPE INSULATED ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- |
| 26 | Overall size 400sq.mm (4Core) Armoured (On-Surface) |
| 27 | Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 28 | Overall size 2.5sq.mm (50/0.25mm), 2Core |
| 29 | COPPER EARTHING (Upto 14 metre in Length):Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 30 | Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length) |
| 31 | COPPER EARTHING STRIP (As Additional Length):Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:- |
| 32 | Additional Length 20mm x 3mm thick Copper Tape |
| 33 | Supply, Installation, testing & commissioning of 160KVA Silent D.G. set and Manual Panel CPCB IV+ Silent DG Set 160 KVA powered by Diesel Engine, 303Manual control panel, battery with leads, fuel tank and AVM Pads, in Acoustic Enclosure incompliance to the latest Norms of CPCB-IV+ and ARAI.Amf( Auto mains failure) for 125 KVA DG set comprising of power contactors with interlocking systems, 2 nos MCCB for mains and DG set complete in all respects with on/off delay timers and VMRs with wiring etc.comprising GREEN COOLED SILENT DG SET comprising of Liquid cooled Diesel Engine Engine , 4 cylinder, inline, 4 stroke cycle, WATER COOLE developing 303 BHP at1500.00 RPM under NTP conditions of BS:5514. The engine shall be provide with electrical starting arrangement & shall give the electrical output 0.8 powerfactor, 230/415 Volts the alternator terminal.Key features of Engines are as below: > Engines are Highly Efficient100% Continuous Operations> Class A-1 Governing (in Genset Application)> Environment Friendly> Low Operation and Maintenance CostCompact Size, Low Footprint> Most Reliable Engine even under extreme conditions |
| 34 | Alternator:- Three Phase, 415V 0.8 PF, type, screen protected, revolvi excited, self-regulated through an AVR. The alternator has the following features:\\"H\\" class insulation- ‡ 1.0% voltage regulation (max.) in static conditions- IP: 23 protection with insulation class H- Permissible overioad of 10% for one hour in 12 hours of operation.Manual PANEL: The Control Panel is manufactured with suitable gaugeCRCA sheet and is powder coated for a weatherproof and long lasting finish.The Controi Panel consists of Microprocessor based electronic controller, MCCB of suitable rating, Key Switch, Push Button (starter), LED: Battery Charging alternator fail indication, Current Transformer, Instrument fuses.The microprocessor electronic controller displays the following parameters:* Voltage, Frequency, Current, Rpm, Cumulative Run Hours, Oil Pressure, Coolant Temperature & Charging Current (DC Amp Meter).The microprocessor electronic controller provides the following safety to the engine:* Under & Over Voltage, Under & over Frequency, Under & Over Speed, Overload, Low Lube Oil Pressure, High Coolant Temperature & Emergency Off.Fuel tank: Sub Base Fuel tank (DRAW IN TYPE) of MS sheet of minimum 250Itr capacity.Base Rail: Base Rail of adequate size is provided.Batteries: For electrical control circuit 1 no., 12 Volts, battery fo starting of DG set. Complete in all respect as desired by the Engineer in charge of work at site. |
| 35 | Making of Cement concrete foundation of size 15' X 8' X 2' high for DG Set. The foundation start with Earth work in excavation 16' x 10' in foundations, Cement Concrete 1:5:10 with 40mm gauge stone agreegate mixing by mechanical means using concrete mixer volumetric type of size 15'x10'x0.75' , First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth size 15'x1.125'x 2' , Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres sizes 15.75'x5.75'x2', Shuttering for faces of concrete foundations and foundations, Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. sizes 15'x8'x0.5', Cold twisted deformed (Ribbed/for Steel Bar) Bar Fe 500 grade as per IS 1786-2008 complete in all respect as per site requirement and as desired by the Engineer in charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysNov 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender