| Sl. No. | Item Description |
| 1 | Taking down carefully existing ceiling fan of any sweep, including disconnecting the electrical connection and removing the existing down rod with its fixing arrangement without damaging the fan, its canopy or the electrical installation, keeping the fan safely at site for re-hanging under item No. 2 and depositing the old down rod in the store of AGE E/M-III, complete all as specified and directed by Engineer-in-Charge. |
| 2 | Supply and fixing in replacement of anti-suicide down rod for ceiling fan, 300 mm long, of mild steel, powder coated in a colour to match the fan, spring-loaded telescopic type which extends and lowers the fan when an added downward load exceeding 20 kg is applied, without affecting the normal running of the fan, compatible with the existing fan shackle and ceiling hook, which the contractor shall check at site before supply, including fasteners, clamps, nuts, bolts, washers, split pins and other accessories; re-hanging the fan taken down under item No. 1, reconnecting, aligning and testing for firm fixing and safe operation, complete all as specified and directed by Engineer-in-Charge. |
| 3 | Supply and fixing of electric water heater, storage type, 50 litre, 2 kW, 230 V single phase, vertical wall-mounted, steel outer body with copper inner tank, BEE 5 star rated, complete with heating element, thermostat, pressure relief safety valve, non-return valve, wall brackets with fixing fasteners and two flexible connection pipes, including connection to the existing hot and cold water lines, testing and commissioning, complete all as specified and directed by Engineer-in-Charge. |
| 4 | Wiring for one independent power point with 2 x 4 sq mm FRLSH PVC insulated copper conductor single core cable in surface steel conduit, along with 1 x 4 sq mm FRLS PVC insulated copper conductor single core cable for loop earthing, from the distribution board to the water heater enclosure under item No. 5, including all conduit accessories, complete all as specified and directed by Engineer-in-Charge. |
| 5 | Supply and fixing of single pole and neutral metal clad industrial type enclosure, 20 A, 230 V, with 2 pin and earth socket outlet with plug top and single pole MCB 20 A, 10 kA, conforming to IS/IEC 60898-1, for the water heater, including connections, complete all as specified and directed by Engineer-in-Charge. |
| 6 | Supply and fixing of flameproof LED light fitting, 40 W, 230 V, Ex d, conforming to IS/IEC 60079-1, suitable for Zone 1 and Zone 2 hazardous areas, gas groups IIA and IIB, temperature class T4, tested by CIMFR or a notified laboratory and approved by PESO, IP 65, die cast aluminium housing with heat resistant toughened glass, LED module with driver and connector, luminous efficacy not less than 100 lm/W, prewired, including flameproof double compression cable gland and connection to the existing flameproof point with 3 core 1.5 sq mm copper conductor flexible cable up to 3 m, testing and commissioning, complete all as specified and directed by Engineer-in-Charge. |
| 7 | Supply and fixing of flameproof LED light fitting for building security lighting, 35 W, 230 V, outdoor type, Ex d, conforming to IS/IEC 60079-1, suitable for Zone 1 and Zone 2 hazardous areas, gas groups IIA and IIB, temperature class T4, tested by CIMFR or a notified laboratory and approved by PESO, IP 66, high pressure die cast aluminium housing with heat resistant toughened glass, impact and corrosion resistant, complete with driver and wall mounting bracket, including flameproof double compression cable gland and connection to the existing flameproof point with 3 core 1.5 sq mm copper conductor flexible cable up to 3 m, testing and commissioning, complete all as specified and directed by Engineer-in-Charge. |
| 8 | Supply and fixing of flameproof exhaust fan, 300 mm sweep, 230 V AC single phase, with flameproof motor Ex d, conforming to IS/IEC 60079-1, suitable for Zone 1 and Zone 2 hazardous areas, gas groups IIA and IIB, temperature class T4, tested by CIMFR or a notified laboratory and approved by PESO, steel body with blades, frame and louvers, fixed with nuts and bolts, including cutting an opening to suit the fan frame in brick or concrete wall up to 230 mm thick, making good and disposal of debris within 50 m, flameproof double compression cable gland and connection to the existing flameproof point with 3 core 1.5 sq mm copper conductor flexible cable up to 3 m, testing and commissioning, complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender