Tender For Repair/ Maintenance Of Ht Electrical Infrastructure Connected Items & Allied Works At Damtal, Kandrori, Nangal Bhur, Kaunterpur And Mirthal Under Ge (South) Pathankot
Tender Value
30 Lakhs
Estimated cost
Bid Submission
05 Dec 2026
21 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pathankot → Punjab
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Maintenance Of Ht Electrical Infrastructure Connected Items & Allied Works At Damtal, Kandrori, Nangal Bhur, Kaunterpur And Mirthal Under Ge (South) Pathankot
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches n.exc 1.5mtr wide and not exc 1.5mtr depth and getting out in any type of soil, complete all as specified and directed. |
| 2 | All as per item No 1here in before but exc 1.5 mtr or part there of in depth beyond 1.5 mtr depth, complete all as specified and directed. |
| 3 | Returning and filling in of excavated soil including spreading,levelling,watering and well ramming in layers not exceeding 25 cm each, complete all as specified and directed. |
| 4 | Removal of surplus soil not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed. |
| 5 | M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid. |
| 6 | Supplying and laying in replacement un-reinforced precast concrete cable cover factory made as per IS 5820-2024, class HV,flat, type 1 , size 300mm x 180mm x 50mm complete all as specified and directed.. |
| 7 | Supply and lay in replacement GI tubes light grade 80 mm dia bore galvanised with all fittings laid in trenches etc for protection of cable complete all as specified and as directed. |
| 8 | Supply and erection in vertical position Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws, type 410 SP-55 (11.0 metres long) all as specified duly factory painted with two coats of black bituminous paint internally through out and externaly for embeded portion and painting with one coat of red oxide primer, applying two coats of synthetic enamel aluminium paint on remaining exposed surfaces after errection complete, painting with synthetic enamel paint of colours black and yellow alternate strips of 30cm width upto 1.5 mtr from the top of coping complete including making suitable holes where required and dismantling existing UNSV conrete poles/ struts of any size complete all as specified and directed .Note : PCC in foundation, coping, Earth work ( Excavation, Returning & refilling and removal) will be measured and paid separately under relative items of Sch 'A', complete all as specified and directed. |
| 9 | M&L for Plain cement concrete (1:4:8) type D-2 (Using 40 mm graded crushed stone aggregate) as in foundation for poles mass concretes or in any indicated positions etc , complete all as specified and directed. |
| 10 | Plain cement concrete (1:2:4) type B-1 (Using 20 mm graded stone aggregate) for coping of pole, complete all as specified and directed. |
| 11 | S&F in replacement Cross arms, bracings, supports, clamps, chequered plates and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium /synthetic paint, inluding dismantling UNSV cross arms, clamps etc complete all as specified and directed. |
| 12 | M&L in replacement of ACSR conductor of any size as ordered by Engr-in-charge including tightening and binding with new binding wires to insulators, dismantling of existing UNSV ACR conductor of any size complete all as specified and directed. |
| 13 | M&L in replacement pin type insulator vitreous, white, brown, or green insulator includig one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150 mm height, 150 mm dia for 11000 volts grade, including dismantling of existing UNSV insulator of any size complete all as specified and directed. |
| 14 | S&F in replacement disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 Volts, including dismantling of existing UNSV insulator of any size complete all as specified and directed. |
| 15 | M&L in replacement of anti climbing device, spikes type fabricated out of MS bars (round/square/flat) including nuts,bolts, washers and welding in two halves made to shape to suit the cross section of the pole including dismantling old one, complete all as specified and directed. |
| 16 | S&F danger in replacement notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps,bolts, nuts of approved size for HT 25x20 cm size including dismantling old one, complete all as specified and directed. |
| 17 | Supply , install, testing and commissioning (in replacement) of HT 11 KV Switch air break, gang operated, triple pole, mechanically operated, mounted on insulators and MS channel frame, with operating mechanism made out of 25 mm dia GI medium grade pipe suitable for operation from ground level with locking arrangement complete for current rating 200 Amps , including dismantling UNSV air break gang operator switches complete all as specified and directed. |
| 18 | S&F in replacement expulsion fuse single phase above 50 & up to 100 AMPS capacity, 11000 Volts, complete all as specified and directed. |
| 19 | M&L for lightning arresters in replacement suitable voltage 11000 volts expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and directed.. |
| 20 | M&L for fixing in replacement Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required with galvanised iron strip 32x6 mm including dismantling old one, complete all as specified and directed. |
| 21 | M&L for fixing in repairs Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required with 4 mm dia galvanised iron or steel wire including dismantling old one, complete all as specified and directed. |
| 22 | Material and labour in replacement earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion. NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing) |
| 23 | M&L in replacement Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level )with top edge of the plate not less than 1.5 Mtr below normal ground level connecting with galvanized iron GI earth wire 4 mm dia by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing) |
| 24 | Supply ,laying , testing & commissioning in replacement of HT UG cable, XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable(heavy duty) with stranded aluminium conductor,6.35/11 KV grade (Earthed system cable) as per IS 7098 Part-II, of size 3 Core 95 Sqmm all as directed including dismantling and taking out old UNSV cable, complete all as specified and directed. Note:- (a) Earth work (Excavation, Returning & refilling and removal), sand cushioning, concrete cable covers,GI pipe protection for road crossings, HT termination joints will be measured and paid separately. |
| 25 | M&L cable jointing kit for 11 KV (Earthed) grade XLPE cable for outdoor end termination cold shrink type joint 3 Core 50 sqmm to 95 sqmm complete with jointing material and accessories suitable for following sizes including testing after jointing complete all as directed . Note:- Earth work ( Excavation, Returning & refilling and removal), sand cushioning, concrete cable covers,GI pipe protection will be measured and paid separately. |
| 26 | M&L cable jointing kit for 11 KV (Earthed) grade XLPE cable for Indoor end termination cold shrinkable type joint complete with jointing material and accessories suitable for 3 core 50 sqmm to 95 sqmm complete with jointing material and accessories suitable for following sizes including testing a XLPE cable including testing after jointing complete all as directed . Note:- Earth work ( Excavation, Returning & refilling and removal), sand cushioning, concrete cable covers,GI pipe protection will be measured and paid separately. |
| 27 | M&L cable jointing kit for 11 KV (Earthed) grade XLPE cable for Indoor end termination cold shrinkable type joint complete with jointing material and accessories suitable for 3 core 120 sqmm to 185 sqmm complete with jointing material and accessories suitable for following sizes including testing a XLPE cable including testing after jointing complete all as directed . Note:- Earth work ( Excavation, Returning & refilling and removal), sand cushioning, concrete cable covers,GI pipe protection will be measured and paid separately. |
| 28 | M&L cable jointing kit for 11 KV (Earthed) grade XLPE cable for outdoor straight through cold shrinkable type joint 3 Core 50 sqmm to 95 sqmm complete with jointing material and accessories suitable for following sizes including testing after jointing complete all as directed . Note:- Earth work ( Excavation, Returning & refilling and removal), sand cushioning, concrete cable covers,GI pipe protection will be measured and paid separately. |
| 29 | M&L in replacement cable jointing kit for 11 KV (Earthed) grade XLPE cable for outdoor straight through cold shrinkable type joint 3 Core 120 sqmm to 185 sqmm complete with jointing material and accessories suitable for following sizes including testing after jointing complete all as directed . Note:- Earth work (Excavation, Returning & refilling and removal), sand cushioning, concrete cable covers,GI pipe protection will be measured and paid separately. |
| 30 | Material & labour for fixing in repairs Stay assembly complete with accessories such as MS stay plate of size 300mmx300mmx6mm thick, stay rod 20mm dia, stay bow, nuts, bolts and check nuts of GI including GI stay strand of size 7/4 mm all as shown in electrical plate No. 1 of SSR Part-I of 2009 , complete all as specified and directed.Note: Earth work ( Excavation, Returning & refilling and removal), PCC, stay clamp and loop type insulators will be measured and paid separately under relevant schedule items). |
| 31 | M&L in replacement for Loop type insulator large size with overall dimensions 90x140mm with clearance of hole 25.5 mm vitreous white brown or green , complete all as specified and directed including dismantling old defective. |
| 32 | Plain cement concrete (1:3:6) type C-2 (Using 40 mm graded stone aggregate) as in foundation filling and mass concrete for stay , complete all as specified and directed. |
| 33 | M & L for cutting of existing hard standing / Road not exceeding 0.30 mtrs wide and 45 cm deep by using necessary tools and plants , returning filling in of excavated material upto required depth and making good the same to match with the existing level, using PCC 1:3::6 of minimum 200 mm thick, the same should be compact and protected untill driedup, If the PCC done by the contractor is settled down due to the impact of the vehicle movement the same will be redone by the Contractor without any extra cost. The balance excavated material will be deposited within 100 mtrs and complete all as specified and directed. |
| 34 | M&L for painting of HT 11 KV PCC/steel four pole structure applying one coat of zinc oxide primer on rusted portions after preparation of surfaces & a coat of aluminum paint to the entire steel structure and two coat of external emulsion wather proof paint on the PCC Poles , complete all as specified and directed. |
| 35 | M&L for painting of HT 11 KV PCC/steel Two pole structure applying one coat of zinc oxide primer on rusted portions after preparation of surfaces & two coat of aluminum paint to the entire steel structure , complete all as specified and directed. |
| 36 | Cutting /trimming tree branches along the over head HT/LT lines up to 3.0 mtr from electric line on both sides of the span and disposing of the cut tree-branches at places, complete all as specified and directed. Note : (i) Necessary permission will be obtained from department by contractor one day prior to trimming in particuar area and shut down of that area shall be arranged by department. (ii) The overhead line shall be maintained for whole period of contract and the payment shall be made once in entire Contract period only. |
| 37 | M/L for stringing of HT/LT Over head line ( ACSR) of any size of overhead line complete including binding with ACSR conductor near pitted conductor, complete all as specified and directed. Note: Stringing of three phase of conductor per span shall be measured and paid separately |
| 38 | M/L for strip opening the metering cubicle of HT panel of rating 11 KV, 3 phase comprising of following repairs in replacement, inspecting, overhauling and servicing/ re-fixing of the spares etc, complete all as specified and directed. a) Dismantling the complete instrument chamber/ HV cable box. Decarbonising/ cleaning the complete HT 11 KV 3 phase independent bus bar, bus bar chamber of HT panel and inspecting the bus bar insulators. b) Checking, inspecting the Numeric/ microprocessor/IDMT relays, multifunction meters/energymeters, ammeters and voltmeters for their serviceability and functionality etc complete. c) Checking complete electrical tripping circuit of HT panel including control wiring from secondary system rotary to tripping coil, auxiliary switch male and female housing cut out, etc. and wiring including replacement of damaged wire at places including operation on DC system, testing and commissioning complete all as directed. d) Inspection of CTs and PTs if any. Replacing the defective CT/PTs incl accuracy in checking of the CT wiring including identification to the base and connecting links to main switchcomplete all as directed by Engineer -in- Charge. e) Inspecting of indicating lamps, rotary switches/selector switches, toggle switches etc complete. Notes: (i) The rate quoted shall be deemed to include for necessary T&P, minor spares like nuts, bolts, washers, gasket, insulation tape, lugs, compound etc. to put in to the HT metering cubicles /panels in serviceable condition, testing and calibration all as specified and as directed by the Engineer-in-Charge.(ii) Major spares like CTs, PTs, relays, ammeters, voltmeters, multifunction meters, energymeters, indicator lamps, control wiring, rotary/selector & toggle switches, calibration of relays etc shall be measured and paid separately under relevant items of Schedule 'A' . However the rate quoted shall be deemed to include for any other minor spares require replacement. Please Enable Macros to View BoQ information |
| 39 | M/L for strip opening the metering cubicle of HT panel of rating 11 KV, 3 phase comprising of following repairs in replacement, inspecting, overhauling and servicing/ re-fixing of the spares etc, complete all as specified and directed. a) Dismantling the complete instrument chamber/ HV cable box. Decarbonising/ cleaning the complete HT 11 KV 3 phase independent bus bar, bus bar chamber of HT panel and inspecting the bus bar insulators. b) Checking, inspecting the Numeric/ microprocessor/IDMT relays, multifunction meters/energymeters, ammeters and voltmeters for their serviceability and functionality etc complete. c) Checking complete electrical tripping circuit of HT panel including control wiring from secondary system rotary to tripping coil, auxiliary switch male and female housing cut out, etc. and wiring including replacement of damaged wire at places including operation on DC system, testing and commissioning complete all as directed. d) Inspection of CTs and PTs if any. Replacing the defective CT/PTs incl accuracy in checking of the CT wiring including identification to the base and connecting links to main switchcomplete all as directed by Engineer -in- Charge. e) Inspecting of indicating lamps, rotary switches/selector switches, toggle switches etc complete. Notes: (i) The rate quoted shall be deemed to include for necessary T&P, minor spares like nuts, bolts, washers, gasket, insulation tape, lugs, compound etc. to put in to the HT metering cubicles /panels in serviceable condition, testing and calibration all as specified and as directed by the Engineer-in-Charge.(ii) Major spares like CTs, PTs, relays, ammeters, voltmeters, multifunction meters, energymeters, indicator lamps, control wiring, rotary/selector & toggle switches, calibration of relays etc shall be measured and paid separately under relevant items of Schedule 'A' . However the rate quoted shall be deemed to include for any other minor spares require replacement. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysDec 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender