Tender For special Repair/ Replacement Of Old Rusted Unsv Ci/Di Pipelines And Connected Items Of Ssd Area And special Repairs Of Bldg No P-102, 109, 115, 121 At 17 Bihar Under Ge Ranchi
Tender Value
49.32 Lakhs
Estimated cost
Bid Submission
04 Dec 2026
12 days left
EMD
98700
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ranchi → Jharkhand
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair/ Replacement Of Old Rusted Unsv Ci/Di Pipelines And Connected Items Of Ssd Area And special Repairs Of Bldg No P-102, 109, 115, 121 At 17 Bihar Under Ge Ranchi
BOQ
| Sl. No. | Item Description |
| 1 | M & L for repairing broken edges of chajja's, roof projection, Fascias etc . In small widths/depths ( exposed area exc 0.05 sqm but n exc 0.10 Sqm ) by breaking the cracked/loose portion and filling with Cement Mortar / Plain Cement Concrete 1:2:4 ,Type B-0 , using 12.5 mm Crushed stone aggregates , over GI wire mesh, giving a coat of anti corrosive paint to exposed Reinforcement and using coat of anti corrosive paint to exposed Reinforcement and using chemical for bonding old and new concrete/plaster and finishing with CM 1:3 plastering, incl 2 coats of white wash to match the exisitng surfaces incl removing debris , necessary scaffolding , etc all as specified and directed. (Note : Reinforcement if any provided shall be measured and paid separately) |
| 2 | Description all as per Ser item No 01 above herein before but exposed area exc 0.10 Sqm but not exc 0.16 Sqm |
| 3 | M&L for repair and rendering 10mm thick in cm 1 :3 on chajjas, facia, roof projection, column sides, beam bottom and sides including throating after removing cracked plaster and concrete including cleaning of viisible reinforcement and treating with cement slurry also necessary repair to cracked concrete if any with cement concrete 1:2:4 Type B-0 using 12.5mm graded aggregate including necessary scafolding work for double/single storey bldgs all as directed . |
| 4 | Mild steel TMT bars 10 mm dia and over as in reinforcement, cut to length, bent to shape required, incl cranking bending spirally for hooping for columns and binding with MS wire (annealed) not less than 0.9 mm dia or securing with clips. |
| 5 | M&L for mild steel 6 - 8mm dia TMT bars bent to shape required, including cranking, bending and binding with mild steel annealed wire not less than 0.9mm dia complete all as specified and directed. |
| 6 | Taking down cement plaster on wall of any description incl racking out joints hacking for key and scrubbing down with water complete all as specified and directed. |
| 7 | M&L 15mm thick rendering on fair faces of bk /concrete surfaces in cm (1:4), finished even and smooth (Without using extra cement ) complete all as specified and directed.including scafolding up to G+3 story bldg, etc complete.complete. |
| 8 | M&L finishing walls on newly prepared surfaces with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.including scafolding up to G+3 story bldg, etc complete.complete |
| 9 | M&L finishing walls on Complete removal of old prepared surfaces with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed. including scafolding up to G+3 story bldg, etc complete.complete. |
| 10 | Demolition of cement concrete unreinforced in floors , roof and pavings n. exc 15 cm thickness (below or above ground level). |
| 11 | Dismantling brick tiles or terracing tiles /roof covering materialsingle layer on roofs complete all as specified |
| 12 | Scarpping surfaces of roof by wire brushing and removing all loose dust and cleaning and washing down the surfaces with water complete . |
| 13 | M&L for 10 mm thick plaster in cement mortor 1:3 laid over roof with integral water proofing admixture @ 200 ml per 50 kgs of cement (after the cement is cured the roof will be testd for water tightness by ponding with water for seven days of any seepage/leakage etc.) Note :- supply only water proofing compound shall be measured and paid separately. |
| 14 | M&L Applying membrane on primed surface by press application method with minimum 75 mm longitudinal wise lap and 100 mm over lap on the transverse direction duly sticked using 3 mm thick APP (Atactic Polyproplene Polymer) modified prefabricated five layer, weight not less than 3.6 kg/Sqm water proofing membrane, black finished non woven polyester reinforced (wt not less than 150 grams) over applying one coat of bituminous primer @ 0.4 kg per Sqm complete all as specified and directed. |
| 15 | M&L for two coats of bituminous based aluminum paint on APP membrane all as specified and directed. |
| 16 | PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in copping, roof kerbs, benches and water troughs etc. including necessary moulding complete all as specified & directed. |
| 17 | 75mm thick, PCC 1:3:6, type C-1 using 20 mm graded stone aggregate, as in plinth protection finished even & smooth without using extra cement complete all as specified and directed . |
| 18 | Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for foundation ect. Or for shafts, well, cesspits, mainholes ect. In any type of soil for foundation and getting out and levelling of bottom surface to required level all as specified and directed by engineer-in-charge |
| 19 | Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 20 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed. |
| 21 | M&L for PCC (1:4:8) type D2 using 40 mm graded stone aggregate in foundation mass concrete and filling including weathering slightly rounded or chamfered complete with necessary use and waste fo form work complete all as specified and directed at site. |
| 22 | Cutting the existing road of any kind straight by manual, depth and width not less than 30 cm for pipes up to 50 mm dia and filling back with excavated soil up to 75 % road portion and 25 % shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate complete all as specified and directed. |
| 23 | M&L for road crossing/ drain crossing by adopting trench less tunnelling work through specified pipe jacking method by erecting the equipment to true to the alignment and gradient by hydraulic pipe jacking technique complete including tunnelling, excavation in any type of soils including hard rock, TO CROSS WATER PIPE LINE UP TO 150 mm dia in any length including jointing materials and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorities complete all as specified and as directed INCLUDING MAKING GOOD OF DISTURBED SURFACE.NOTE: Pipe will be measured and paid separately under relevant items. |
| 24 | Taking up (dismantling and removing) existing CI/DI water mains, including all associated fittings such as bends, tees, reducers, collars, specials, etc., having spigot and socket ends or flanged joints, including burning out / cutting and removing existing lead joints from spigot and socket connections and dismantling of flanged joints, complete all as specified and directed by Engr-in-charge, of following sizes:-Note :- Taking down of the existing pipe and laying, jointing, and connecting of the new pipe shall be carried out simultaneously on the same day to ensure uninterrupted and continuous water supply. |
| 25 | 150mm dia |
| 26 | 100mm dia |
| 27 | 80mm dia |
| 28 | Supply, laying, jointing, fixing, testing and commissioning of Ductile Iron (DI) pipes, spigot and socket (S/S) ends, Class K-9, conforming to IS:8329 / ISO:2531, complete, pipes shall be laid in trenches or in open execution, as directed at site, including excavation in all kinds of soil, lowering, aligning, jointing using rubber gasket (push-on joint) or approved jointing material, including cutting of pipes, deflection at joints where required, and thrust blocks / anchor blocks wherever necessary, includes hydrostatic pressure testing, and making good disturbed surfaces, complete all as specified and as directed by the Engineer-in-Charge of following sizes of pipes.Note :- Necessary earth and PCC/Brick work will be measured and paid seperately |
| 29 | 150mm dia |
| 30 | 100mm dia |
| 31 | 80mm dia |
| 32 | Taking up or down steel tubing and connections, from trench or wall/floor including cleaning the pipes free from scaling for re-fixing or removal complete with all fittings and connections of the following sizes :-Note : (a) Excavation and Earth work shall be measured and paid separately. |
| 33 | 20 mm dia |
| 34 | 25 mm dia |
| 35 | 40 mm dia |
| 36 | 50 mm dia |
| 37 | Refixing of old steel tubing and connection in new or old position including cleaning and removal of scaling, cutting threads if required, fittings with old/ new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches, floors, walls and ceilings and testing for leakages complete all as specified and directed for the following sizes:- |
| 38 | 20 mm dia |
| 39 | 25 mm dia |
| 40 | 40 mm dia |
| 41 | 50 mm dia |
| 42 | Supply and laying steel water tubing medium grade, galvanised with all fittings such as bends, elbow, tee, socket, reducers, unions etc as required at site laid in trenches, fixed to wall and ceilings and testing for leakages complete all as specified and directed for the following sizes:-Note : (a) Excavation and Earth work shall be measured and paid separately. |
| 43 | 20 mm dia |
| 44 | 25 mm dia |
| 45 | 40 mm dia |
| 46 | 50 mm dia |
| 47 | Supply and fixing in replacement of cast iron sluice valves, PN-1.6, with flanged or socket & spigot ends as specified, SS stem, gun metal working parts, flanges drilled to PN-1.6, jointing, testing and commissioning, complete all as specified and directed |
| 48 | Description all as per Ser item No 29 here-in-before but of size 150 mm dia |
| 49 | Description all as per Ser item No 29 here-in-before but of size 100 mm dia |
| 50 | Description all as per Ser item No 29 here-in-before but of size 80 mm dia |
| 51 | Supply and fixing, jointing, testing and commissioning of Ductile Iron (DI) specials, suitable for socket and spigot (S&S) joints as well as flanged joints, conforming to IS:8329 / IS:9523 / ISO:2531, DI bends of any type, radius and angle, DI tapers of all types such as straight tapers, increasing or decreasing tapers, double socket tapers, tee pieces (single branch), Y-junctions, double branch tees, crosses, collars, end caps, and plugs, with all-socket, socket-and-spigot, or flanged end configurations, suitable for any bore size up to 350 mm diameter including lowering, aligning and jointing of specials using rubber gasket (push-on) joints for socket and spigot connections and bolted flanged joints for flanged connections, including supply and fixing of gaskets, nuts, bolts and washers, cutting and trimming where required, deflection at joints, provision of thrust / anchor blocks wherever necessary, and all jointing materials, labour, tools and accessories, pressure testing of joints, checking alignment and leak-proof performance, and commissioning of the pipeline, complete all as specified and as directed by the Engineer-in-Charge |
| 52 | Cutting existing CI/DI pipe line for insertion of new tees, collars for branch connections complete all as specified and directed for the following sizes:- Note: CI / DI specials, Joints and Earth work shall be measured and paid separately under relevant items of this schedule. |
| 53 | Description all as per Ser item No 31 here-in-before but of size 150 mm dia |
| 54 | Description all as per Ser item No 31 here-in-before but of size 100 mm dia |
| 55 | Supply and fix in replacement of unserviceable Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and directed for the following sizes:- |
| 56 | 25mm dia bore |
| 57 | 40mm dia bore |
| 58 | 50mm dia bore |
| 59 | Supply and fixing ball valve of specified size, forged brass body, chrome-plated brass ball, 20 mm bore PTFE seats, lever operated, screwed female BSP ends, suitable for working pressure PN16, complete all as specified and directed |
| 60 | M&L drilling and tapping Ductile iron/ Cast iron water mains 20 mm bore in position for branch connections of following internal dia size complete all as directed at site. |
| 61 | S&F in repair straight plain brass ferrules 20 mm bore (or connecting screws)screwed both ends of following size dia complete all as directed at site. |
| 62 | Supply and fixing in replacement of float valve brass, 20 mm dia, high pressure with polythene float and fly nut complete screwed for iron pipe of following sizes:- |
| 63 | Construction of valve pit of sizes 900mmx900mmx900mm (internal dimentions), any type soil, returning, filling in, disposal of surplus spoil to a distance not exceeding 50m and depositing where directed, 100mm thick PCC in foundation of the mix (1:4:8), type D-2, (using 40mm graded crushed stone aggregate) brick masonry in cement mortar (1:4), rendering, 12 mm thick cement mortar (1:4) internally, finished even and fair & pointing flush externaly as the work proceeds in the same mortar, mild steel frame, MS sheet cover 5mm thick with handle and locking arrangement, painting all the exposed MS work with two coats of synthetic enamel paint of the tint as approved by the GE over a coat of red oxide primer and painting all the MS embedded in PCC with two coats of black bituminous paint including dismantling old unsv valve pit, complete all as specified. |
| 64 | Construction of valve pit of sizes 600mmx600mmx600mm (internal dimentions), any type soil, returning, filling in, disposal of surplus spoil to a distance not exceeding 50m and depositing where directed, 100mm thick PCC in foundation of the mix (1:4:8), type D-2, (using 40mm graded crushed stone aggregate) brick masonry in cement mortar (1:4), rendering, 12 mm thick cement mortar (1:4) internally, finished even and fair & pointing flush externaly as the work proceeds in the same mortar, mild steel frame, MS sheet cover 5mm thick with handle and locking arrangement, painting all the exposed MS work with two coats of synthetic enamel paint of the tint as approved by the GE over a coat of red oxide primer and painting all the MS embedded in PCC with two coats of black bituminous paint including dismantling old unsv valve pit, complete all as specified. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysDec 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender