Tender For National Bank For Agriculture And Rural Development Department Of Premises, Security And Procurement Nabard, Keralam Regional Office, Thiruvananthapuram
Tender Value
63 Lakhs
Estimated cost
Bid Submission
04 Dec 2026
15 days left
EMD
1.26 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvananthapuram → Kerala
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for National Bank For Agriculture And Rural Development Department Of Premises, Security And Procurement Nabard, Keralam Regional Office, Thiruvananthapuram
BOQ
| Sl. No. | Item Description |
| 1 | MSB - 1 & 2Supply, erection, testing, and commissioning of dust and vermine proof floor mounted powder coated sheet steel enclosure consisting of main incomer: 400A TPN isolator with rotary handle -1 No out going 250 A TP MCCB—3 Nos VAF with C.T & control MCB 0.5A, and MCB with RYB indicators - 1 set suitable bus bar of 50mm x 12mm aluminium |
| 2 | GSB-1Supply, erection, testing, and commissioning of dust and vermine proof floor mounted powder coated sheet steel enclosure consisting of main incomer: 320A TPN MCCB with rotary handle – 1 No Outgoing 100/125 A TP MCCB - 6Nos VAF with C.T & Control MCB 0.5A MCB With RYB indicators - 1 set suitable bus bar of 50mm x 10mm aluminium |
| 3 | SSB#-1 BlockSupply, erection, testing, and commissioning of dust and vermine proof floor mounted powder coated sheet steel enclosure consisting of main incomer: 250A 4p MCCB with rotary handle - 1No Outgoing 125A TPN MCCB, 5Nos VAF with C.T & CONTROL MCB 0.5A with RYB indicators --1 set suitable bus bar |
| 4 | GSSB#-1Supply, erection, testing, and commissioning of dust and vermine proof floor mounted powder coated sheet steel enclosure consisting of main incomer: - 125A TPN MCCB --1 No, outgoing 63 A TPN MCB- 1Nos, and 32 A TPN MCB -3 Nos with suitable copper bus bar and etc., 4-way VTPN MCCB DB DOUBLE DOOR |
| 5 | Generator DB-1Supply, erection, testing, and commissioning of dust and vermine proof floor mounted powder coated sheet steel enclosure consisting of main incomer: -- 40A 4POLE 30mA RCBO - 1 No., Outgoing 2 or 5 A SP MCB - 12 Nos with suitable copper bus bar and etc., 4-way TPN MCB DB DOUBLE DOOR |
| 6 | Generator DB-2Supply, erection, testing, and commissioning of dust and vermine proof floor mounted powder coated sheet steel enclosure consisting of main incomer:-- 40A 4POLE 30mA RCBO - 1 No, Outgoing 2 or 5A SP MCB - 18 Nos with suitable copper bus bar and etc., 6 way TPN MCB DB DOUBLE DOOR |
| 7 | Generator DB-3Supply, erection, testing, and commissioning of dust and vermine proof floor mounted powder coated sheet steel enclosure consisting of main incomer:-- 63A 4POLE 30mA RCBO - 1No Outgoing 2 or 5A SP MCB - 24 Nos with Suitable copper bus bar and etc., 8-way TPN MCB DB DOUBLE DOOR |
| 8 | Common Panel – 1Supply, erection, testing, and commissioning of dust and vermine proof floor mounted powder coated sheet steel enclosure consisting of main incomer:-- 100A TPN MCCB --1 No., Outgoing 32 A SP MCB - 3 Nos, and 32A TP MCB -1 No., 40A TP Isolator-3 Nos., 63A TP MCB- - 1No., with suitable copper bus bar and etc., 6 way VTPN MCCB DB DOUBLE DOOR |
| 9 | Common ATS (COS)-1Supply, erection, testing, and commissioning of dust and vermine proof wall/floor mounted powder coated sheet steel enclosure consisting of 63 A 4 POLE AUTOMATIC COSr:--1 No., RYB INDICATOR SET for DG/KSEB -6 No. with control MSB |
| 10 | Metering Panel - All BlockSupply, erection, testing, and commissioning of dust and vermine proof floor mounted metering panel copper bus bar 25 x 6 and neutral 25x3 MAIN INCOMER 125A 4 POLE ISOLATOR with rotary handle --1No with RYB indicator.Meter box -8 Nos (3 phase metering board with 63A FUSE UNIT HRC TYPE and 50/40A fuse link - 3 Nos, 63A neutral link and 40/63A 4 pole MCB-1 No, Inter Connections using meter to fuse and MCB using 10 Sq. mm CU wire and etc) |
| 11 | Laison work with KSEB officials for changing the panel connections in each flat |
| 12 | Labour charges for removing and refixing the KWHR meter |
| 13 | Labour charges for removing and re-termination of GSSB generator connections and etc, including temporary connections etc., |
| 14 | Labour charges for removing and re termination of GSB generator connections and etc, including temporary connections etc., |
| 15 | Labour charges for removing all connections at MSB existing panel and temporary arrangements connections, etc., |
| 16 | Labour charges for removing and re termination of generator DB connections and etc, including temporary connections etc., |
| 17 | Supply and fixing copper earth bench 12-hole 25 x 3mm tinned |
| 18 | Supply and laying 6 swg copper bare earth for all body inter link connections |
| 19 | Supply and laying 10 swg copper bare earth for all body inter link connections |
| 20 | Supply and laying 25 x 3 mm copper bare earth for pit to bench & body inter link connections |
| 21 | Supply, installation and commissioning of copper plate earthing using 600 x 600 x 3 mm copper plate and 25 x 3 mm copper strip, 35 mm G.I pipe using 2.5 mtr watering and masonal chamber, funnel and filling charcoal with chemical and etc as per IS 3043 (each flat - 3 Nos) |
| 22 | Supply and fix cable end termination using cable gland, socket for termination box or joint kit and etc cables 4 x 10 to 35 sq mm AYFY cable existing cable connections to metring panel |
| 23 | Supply and fix cable end termination using gland socket and etc., for meter cables 4 x 10/16 AYFY cable |
| 24 | Supply and fix cable end termination using gland socket and etc., for meter cables 4 x 25/35/50 AYFY cable |
| 25 | Supply and fix cable end termination using gland socket 4 x 70/95/120 AYFY cable |
| 26 | Supply and fix cable end termination using gland socket cables 4 x 185 AYFY cable |
| 27 | Supply and fix cable end termination using gland socket 4 x 240 AYFY cable |
| 28 | Supply and fix cable end termination using gland socket 4 x 300 AYFY cable |
| 29 | Supply and fix cable end termination using joint kit or termination box forout door transformer side 4 x 300 AYFY cable |
| 30 | Supply and laying armoured cable through floor/wall and clamped etc 4 x 10 AYFY |
| 31 | Supply and laying armoured cable through floor/wall and clamped etc 4 x 16 AYFY |
| 32 | Supply and laying armoured cable through floor/wall and clamped etc 4 x 25 AYFY |
| 33 | Supply and laying armoured cable through floor/wall and clamped etc 4 x 35 AYFY |
| 34 | Supply and laying armoured cable through floor/wall and clamped etc 3.5 x 50 AYFY |
| 35 | Supply and laying armoured cable through floor/wall and clamped etc 3.5 x 70 AYFY |
| 36 | Supply and laying armoured cable through floor/wall and clamped etc 3.5 x 95 AYFY |
| 37 | Supply and laying armoured cable through floor/wall and clamped etc 3.5 x 120 AYFY |
| 38 | Supply and laying armoured cable through floor/wall and clamped etc 3.5 x 150 AYFY |
| 39 | Supply and laying armoured cable through floor/wall and clamped etc 3.5 x 185 AYFY |
| 40 | Supply and laying armoured cable through floor/wall and clamped etc 3.5 x 240 AYFY |
| 41 | Supply and laying armoured cable through floor/wall and clamped etc 3.5 x 300 AYFY |
| 42 | Supply and laying armoured cable through floor/wall and clamped etc 6 x 2.5 Copper Cable for generator control cable and battery charges and auto starter |
| 43 | Supply and wiring using 3 x 1.5 sq. mm copper wire with 20mm (M) PVC pipe and modular switches etc for light/fan/exhaust fan point at meter box rooms |
| 44 | Supply and wiring 3 x 2.5 sq mm Cu wire circuit wiring and etc through 20 mm PVC pipe |
| 45 | Labour charges for making the trench and fill red brick with sand and etc up to 90 cm depth for laying the cables |
| 46 | Labour charges for cleaning the existing trench and opening the slab and relaying he slab and etc including minor civil work and etc |
| 47 | liaison work with electrical inspectorate for full approval and sanction for 125 KVA generator, 250 KVA transformer and submitting all the SLD with approved diagrams etc… |
| 48 | MAIN INCOMER PANELSupply, erection, testing and commissioning of a dust-proof and vermin-proof floor-mounted LT panel fabricated from 16 SWG CRCA sheet steel, powder-coated after suitable surface treatment, complete with the following:Main Incomer: 1 No. 800A-1000A, 440V, 4 Pole, Motorised ACB, 50kA breaking capacity, microprocessor-based protection unit (L&T U-Power or equivalent) complete with Over Current, Earth Fault and Short Circuit Protection (O/C + E/F + S/C), shunt trip release, under-voltage release, auxiliary contacts and all associated accessories.Suitable spreaders, busbar supports, cable alleys, glands and termination arrangements.Outgoing Feeders: 6 Nos. 250A TP MCCBs with required accessories.Voltmeter and Ammeter with selector switches, CTs, control MCBs, indicating lamps and measuring instruments.RYB phase indication lamps complete with 0.5A control MCBs.Heavy-duty aluminium busbar system rated for 1500A, complete with PVC sleeves, supports, shrouding and busbar chambers. |
| 49 | Buy back all material Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysDec 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender