Housing Urban and Rular Development Local Bodies Closing in 4 days TDR #58513236

Tender For Development Of City Forest At Colony No.4 Sukhna Choe Forest Industrial Area Phase-1, Chandigarh

Issued by Local Bodies · Chandigarh, Chandigarh
Tender Value
12.41 Crore
Estimated cost
Bid Submission
26 Nov 2026
4 days left
EMD
22.41 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Development Of City Forest At Colony No.4 Sukhna Choe Forest Industrial Area Phase-1, Chandigarh

BOQ

Name of Work:- development of city forest at colony no.4 sukhna choe forest industrial area phase-1, chandigarh
Sl. No. Item Description
1civll work
2Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m complete in all respects and to the entire satisfaction of Engineer in charge. N.S.
3Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m
4Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil
5Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
6Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
7Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
8Preparation and consolidation of sub grade after loosening of the ground upto a level of 150 mm below the sub-grade level, watered, mechanically/manual means and compacted in layers to meet requirement of table 300-2 for sub-grade construction complete in all respect in all respects and to the entire satisfaction of the Engineer in charge. N.S.
9Providing, laying, spreading and compacting granular sub base material 100-200 mm thick compacted of natural sand, morrum, gravel crushed stone or combination thereof as per MORT&H specification confirming to clause 401 coarse graded grading – 3 as per table 400.1 of MORT&H specification, including spreading on the prepared sub grade with the help of tractor with planner of adequate capacity maintaining the requited slope and grade during operation, rolling with road roller 8-10 tone with the grade and cross fall (camber) to be checked and any high spot or depressing which becomes apparent, corrected by removing or adding fresh material, including cost of tools and plants, carriage of material from stacks, templates, barrier, lighting arrangement at night, chowkidar and maintenance of diversion etc. complete in all respect as per MORT&H specifications, density of GSB as laid 2 gms/cc complete in all respect and to the entire satisfaction of Engineer in charge.
10Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete (DSR 5.9.1)
11Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
12Centering and shuttering including strutting, propping etc. and removal of form Shelves (Cast in situ)
13Centering and shuttering including strutting, propping etc. and removal of form Lintels, beams, plinth beams, girders, bressumers and cantilevers
14Centering and shuttering including strutting, propping etc. and removal of form Columns, Pillars, Piers, Abutments, Posts and Struts
15Centering and shuttering including strutting, propping etc. and removal of form Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
16Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22.6)
17Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
18Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth
19Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) (DSR 4.1.10)
20Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
21Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
22Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) (DSR 5.1.2)
23Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
24Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
25Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum
26Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate I retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth levelConcrete of M30 grade with minimum cement content of 350 kg /cum
27Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate I retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M30 grade with minimum cement content of 350 kg /cum All works above plinth level upto floor V level
28Add for using extra cement in the items of design mix over and above the specified cement content therein.
29Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR No. 4.1.2)
30Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR 10.2)
31Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (DSR 10.25.2)
32Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube
33Galvanised Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (NS)
34Providing and Fixing 1\\" dia Synthetic Manilla Rope on existing Bamboo Railing by looping it around the railing to give it enough strength to act as railing to the entire satisfaction of engineer in charge (NS)
35Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.l. limpet washers or with G.l. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m2
36Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of size 595 × 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225:1987, non-combustible as per BS 476 (Part 4)-1970 and light reflectance of 85% (minimum), laid in true horizontal level suspended on interlocking hot dipped galvanised iron T-grid complete with main runners, cross runners, intermediate cross tees, hanger rods, dash fasteners, level adjusters, perimeter wall angle and all accessories, complete as per specifications, drawings and directions of the Engineer-in-Charge. With fully perforated 12 mm thick micro tegular edged or 10 mm thick square edged GRG false ceiling tiles.
37Providing and fixing 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/tiles with GI framework, complete with jointing and finishing using recommended calcium silicate based jointing compound, fibre joint tape, primer etc., all complete as per manufacturer's specifications and as directed by the Engineer-in-Charge. With 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/tiles.
38Providing and Fixing Synthetic Bamboo Railing of diameter 75mm & thickness 3mm of required length made up of 100% recyclable, ASA resins added material for high durability and strength having minimum warranty period of 10 Years. It should be fire resistant & should be tied with one another with screws and bamboo ropes to join the members together as per the site and structural strength to the entire satisfaction of Engineer in Charge (NS).
39Providing and Fixing Synthetic Bamboo Railing of diameter 55mm & thickness 3mm of required length made up of 100% recyclable, ASA resins added material for high durability and strength having minimum warranty period of 10 Years. It should be fire resistant & should be tied with one another screws and bamboo ropes to join the members together as per the site and structural strength to the entire satisfaction of Engineer in Charge (NS).
40Providing and Fixing Synthetic Bamboo Railing of diameter 95mm & thickness 3mm of required length made up of 100% recyclable, ASA resins added material for high durability and strength having minimum warranty period of 10 Years. It should be fire resistant & should be tied with one another screws and bamboo ropes to join the members together as per the site and structural strength to the entire satisfaction of Engineer in Charge (NS).
41Providing and Fixing Wooden planks of 35mm thick second class teak wood (kiln seasoned) of size 4'0\\" x 0'9\\" tied together with Bamboo Rope having gap of 6\\" in between and engraved with required text and Colour as per the site requirements. The plank should be treated with anti-termite & should be Weather protected to the entire satisfaction of Engineer in Charge (NS).
42Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red - Area of slab over 0.50 sqm (DSR no. 8.2.2.2)
43Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) For fixed portion - Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (DSR No. 21.1.1.1)
44Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) (DSR no. 21.3.3)
45Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
46Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mmthick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Light shade pigment using white cement
47Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/Granite / stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
48Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer in-charge: Profile B -Fixing with adjustable lugs with split end tail to each jamb (DSR No. 10.14.1.1)
49Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
50Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality1.0 mm thick
51Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : Cement mortar 1:6 (1 cement : 6 Coarse sand)
52Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to 18:2185(Part 3)in superstructure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately)
53Stoneworkin plain ashlar in superstructure upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : Both face dressed Red sand stone
5425 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with : Second class teak wood
55Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete
56Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Kiln seasoned and chemically treated hollock wood. 35 mm thick
57Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
58Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws: 35 mm thick shutters. with ISI marked M.S. pressed butt hinges bright finished of required size - Second class teak wood Kiln seasoned and chemically treated hollock wood 35 mm thick
59Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws: 35 mm thick shutters. with ISI marked M.S. pressed butt hinges bright finished of required size - Second class teak wood Kiln seasoned and chemically treated hollock wood
60Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 300x16 mm
61Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm
62Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 250x10 mm
63Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 200x10 mm
64Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 150x10 mm
65Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete 125 mm
66Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete 100 mm
67Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete Twin rubber stopper
6825 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762 mm X 25 mm or less as per requirement with an average wall thickness of 1 mm (± 0.3 mm). PVC foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size 25 mm X 11 mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufacturer’s specification and direction of Engineer-in-charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places
69Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement , including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturer’s specification and direction of Engineer-in-charge.
70Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes (DSR no. 10.30.1)
71Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR no. 4.2.5)
72Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (DSR 12.50)
73Providing and fixing 6mm thick polycarbonate multi wall sheet to be fixed on existing M.S. frame with Aluminum rivets complete in all respect to the entire satisfaction of Engineer-in-charge.
74Providing and fixing top aluminium profile with rubber gasket to seal the joint of polycarbonate sheet with self drilling screws etc complete fixed in all respect and to the entire satisfaction of Engineer-in-charge.
75Providing and fixing bottom aluminium profile with rubber gasket to seal the joint of polycarbonate sheet with self drilling screws etc complete fixed in all respect and to the entire satisfaction of Engineer-in-charge.
76Providing and fixing 1500mmX140mmx19mm thick IPE wood decking planks, with eased edges and anti-slip grooves, fixed with SS 304 clips and screws over aluminium hollow box section 25x50x 1.65mm sub-frame grid laid @ 400mm c/c bothways. Aluminium pipes to be filled with soft wood battens of section 25mmx25mm for additional strength and screw holding. Grid supported on aluminium height riser pedestals adjustable 50-150mm for level and ventilation, fixed to RCC slab with anchor fasteners @ 600mm c/c. Gap 5-6mm between planks for drainage. All aluminium sections mill finish/6000 series alloy. Top surface finished with 2 coats of decking oil. Including cost of all materials, labour, T&P, wastage, etc complete in all respect to the entire satisfaction of Engineer- in -charge
77Providing and fixing 1500mmX140mmx19mm thick IPE wood planks , fixed over existing MS angle frame using SS 304 hex head nut-bolts 8mm dia x 50mm with SS washers and neoprene washers. Planks end sealed with wax sealer. Gap 5mm between planks for drainage. Top surface finished with 2 coats of UV resistant decking oil. Including cost of drilling, counter sinking, nut-bolting, wastage, labour, T&P, etc complete in all respect to the entire satisfaction of Engineer In Charge.
78Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :.Masonry work (first sort), in cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 7.1.1)
79Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like. Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 7.2.1)
80Providing and laying 75 mm thick stone soling with hard stone aggregates 25-40mm size hand packed, with interstices filled with smaller stone chips (6-10 mm size), properly compacted with power road roller / plate vibrator compacter to required grade and camber on existing base of PCC, including spreading fine aggregates, watering and compaction, etc complete.
81Providing and laying 20-25mm Kandla Grey natural stone flooring in required design and patterns, in linear , risers , skirting as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
82Brick edging 7 cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
83Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: 1:4 (1 cement 1 : 4 coarse sand) (DSR 11.1.1)
84Providing fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS : 8183, density 24kg / m3, 50 mm thick, wrapped in 200 G Virgin Polythene bags, fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 gauge wire mesh, for top most ceiling of building.
85Providing and fixing thermal insulation with Resin Bonded Fibre glass woolconforming to IS: 8183 having density 24 kg/m3, 50 mm thick, wrappedin 200G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in-Charge.
86Providing and fixing 2400mm X146mmx 24mm thick WPC decking planks, with eased edges and anti-slip grooves, fixed with SS 304 clips and screws over aluminium hollow box section 25x50x 1.65mm sub-frame grid laid @ 400mm c/c bothways. Aluminium pipes to be filled with soft wood battens of section 25mmx25mm for additional strength and screw holding. Grid supported on aluminium height riser pedestals adjustable 50-150mm for level and ventilation, fixed to RCC slab with anchor fasteners @ 600mm c/c. Gap 5-6mm between planks for drainage. All aluminium sections mill finish/6000 series alloy. Including cost of all materials, labour, T&P, wastage, etc complete in all respect to the entire satisfaction of Engineer- in -charge
87Providing and laying of gabion stone wall, edging, columns etc. crates of required Size with stone sizes 75-150mm thick hand packed tightly in wire crates made with 4mm dia GI wire conforming to IS: 280 & IS:4826 in 100mm x 100mm mesh (weaved diagonally, double twist at each inter section) including 10 percent extra for laps and joints complete in all resepect of MORT&H Specifications and to the entire satisfaction of the Engineer-in-charge. N.S.
88Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
89Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete
90Providing and laying 1st quality ceramic glazed wall tiles of size 300x450 mm conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make, in all colours, shades as approved by Engineer-in-Charge,in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand). The tiles are to be fixed by providing 2 mm thick spacer. The area of spacer is to be filled by using cement based grout of approved shade. The grooves are to be filled with cemenitious grout mix with proportion of 0.90 kg grout and 0.10 kg of hardener for each kg of filling material complete in all respect and to entire statisfaction of Engineer-in-Charge.
91Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
92Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.
93Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
94Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain) 110 mm Shoe
95Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.( DSR 12.22)
9662 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. (DSR 11.5)
97Extra for hiring of crane making , assembling the MS steel structure in their position
98Providing and fixing 2400mmX146mmx24mm thick WPC decking planks, fixed over existing MS angle frame using SS 304 hex head nut-bolts 8mm dia x 50mm with SS washers and neoprene washers. Planks end sealed with wax sealer. Gap 5mm between planks for drainage. . Including cost of drilling, counter sinking, nut-bolting, wastage, labour, T&P, etc complete in all respect to the entire satisfaction of Engineer In Charge.
99Providing and fixing Synthetic Bamboo Thatch on existing GI sheet roof and joining the thatch properly with the existing roof with the help of Bamboo Ropes and Screws including Scaffolding, carriage and T & P in all respect to the entire satisfaction of Engineer In Charge (NS).
100Providing and fixing Synthetic Bamboo Mats on existing GI sheet roof and joining the thatch properly with the existing roof with the help of Bamboo Ropes and Screws including Scaffolding, carriage and T & P in all respect to the entire satisfaction of Engineer In Charge (NS).
101Providing and fixing Synthetic Bamboo Panel Ceiling on existing Truss roof and screwing and installing the Ceiling properly with the existing truss with the help of necessary Screws, glue etc including Scaffolding, carriage and T & P in all respect to the entire satisfaction of Engineer In Charge (NS).
102Providing, designing, fabricating, and installing FX Linearlux Wooden Grooved Acoustical Panel system or approved equivalent on wall and/or ceiling substrates, comprising 16mm thick high-density engineered wood panel (density 750–850 kg/m³) conforming to IS:12406 / EN 622-5, CNC-profiled with 4mm linear grooves at 28mm module (c/c) and finished in approved decorative laminates/veneers (Maple, Sea Beech, Ivory Coast, Classic Walnut, White Pine) with sealed edges and protective coating. Panels shall be acoustically optimized with 10mm dia rear perforations in calibrated pattern to achieve system NRC ≥0.78 (ASTM C423 / ISO 354) under installed conditions with specified backing. Fixing shall be executed over corrosion-resistant extruded aluminium sub-framing using concealed clip-in arrangement or direct mechanical fastening onto prepared substrate, ensuring tolerance-controlled alignment, modular continuity, and allowance for dimensional movement. Providing and fixing acoustical insulation comprising 50mm thick resin-bonded mineral wool/glass wool insulation of minimum 50 kg/m³ density in black finish/shade, conforming to relevant IS/ASTM standards for thermal and acoustic performance. Insulation shall be securely installed within a framework made of G.I. sections of approved size and gauge, duly suspended/fixed as per approved drawings and site requirements. The insulation shall be properly cut, fitted, and mechanically retained without sagging, gaps, or displacement, ensuring continuous acoustic coverage and enhanced sound absorption performance. The scope shall include all necessary G.I. framework members, supports, cleats, fasteners, anchors, and accessories required for complete installation, finished true to line, level, and plumb as directed by the Engineer-in-Charge.
103Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works.
104Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work (DSR no. 13.61.1)
105Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work (DSR 13.52.1)
106Providing and laying 40-50mm thick random rubble flat stone flooring/walling in random pattern, stone dressed on top + sides, laid evenly on 25mm thick cement mortar bed 1:4, joint 8-12mm wide filled with 2-part epoxy resin grout, including cutting, cleaning, curing, finishing, complete as per IS 3316 & direction of Engineer-in-charge.
107Providing and laying antiskid vitrified floor tiles of size 600 x 600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade. The tiles are to be laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand). The tiles are to be fixed with 2 mm grove using spacers. The grove are to be filled with cementitious grout mix with proportion of 0.90 kg grout and 0.10 kg of hardener for each kg of filling material complete in all respect and to entire statisfaction of Engineer in Charge.
108Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor five level in : Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR no. 6.32.1)
109Half brick masonry with non modular fly ash bricks of class designation 10, conforming to IS :12894, in super structure above plinth upto floor V level. Cement mortar 1 : 3 (1 cement : 3 coarse sand) (DSR No. 6.45.1)
110Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4(1 cement :4 coarse sand) DSR 6.1.1
111Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand)
11212 mm cement plaster of mix: 1:6(1 cement: 6 fine sand)
11315 mm cement plaster on rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand)
1146 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand)
115Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
116Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
117Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
118Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
119Providing and applying of CNC Laser cut on a Mild Steel Plate of thickness 3mm into required shape of animal and tree as required as per the entire satisfaction of Engineer in charge.
120Supply Installation Testing & commissioning of 533 mmc/c Fire Retardant fabric upholstered chair conforming to BIFMA standards. The chair to have MS tubular framework welded together with continous arc welding. The chair shall have powder coating of 65microns on all of the MS tubular framework . The seat shall have Polyurethane foam of density 55+3 KG/Cum & Back to have density of 50+3 Kg/CuM. The height of the back to be 950-1000mm from the ground to top of back & for Seat to be 400-450mm from the ground . The rear of back shell & bottom of seat shell to be Polypropylene plastic in black colour Polypropylene plastic cover. The wooden armrest to be of 80mm & 400mm length with melamie polished in black colour . The armrest between two chairs in a row to be shared & at the both ends to be individual. Including cost of suitable chemical expnasion fastners as required of Hilti/Fischer make. Make Penworkers/ Featherlite /Godrej.
121PUBLIC HEALTH WORK
122Carriage of material by mechanical transport including loading, unloading and stacking.
123Earth upto 1 Km.
124Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.
125All kinds of soil
126Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
127All kinds of soil.
128Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
129Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
130Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
131Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
132All kinds of soil
133CONCRETE WORK
134Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level.
1351:2:4 (1 cement : 2 coarse sand (zone-III) derived fromnatural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1361:4:8 (1 Cement : 4 coarse sand (zone-III) derived fromnatural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
1371:5:10 (1 cement : 5 coarse sand (zone-Ill) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
138Providing & applying a coat of residual petroleum bitumen of gradeof VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
139REINFORCED CEMENT CONCRETE
140Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level
1411:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
142Centering and shuttering including shuttering, propping etc. and removal of form to:-
143Foundations, footings, bases of columns, etc. for mass concrete
144Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
145Suspended floors, roofs, landings, balconies and access platform
146Edges of Slab and breaks in slab and floor
147Unde 20 cm wide
148Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.
149Cold twisted bars
150Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
151Cement mortar 1:4 (1 cement : 4 coarse sand)
152Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
153Cement mortar 1:6 (1 cement : 6 coarse sand)
154Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarsesand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
155300 mm x 600 mm
156Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a primingcoat of approved steel primer all complete.
157Steel work welded in built up ections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using tructural steel etc. as required.
158In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works
159Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete.
160Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4(1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
16112 mm cement plaster of mix :
1621:6 (1 cement : 6 fine sand)
16312 mm cement plaster finished with a floating coat of neat cement of mix :
1641:4 (1 cement: 4 fine sand)
165Cement plaster (1:3) finished with a floating coat of neat cement.
16612 mm Cement Plaster
167Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
168Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
169Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
170W.C. pan with ISI marked white solid plastic seat and lid
171Providing and fixing white vitreous china water closet squatting pan (Indian type) :
172Orissa pattern W.C. pan of size 580x440 mm
173Providing and fixing 8 mm dia C.P./ S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge
174Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete.
17510 litre (full flush) capacity-white
176Providing and fixing soil, waste and vent pipes
177100 mm dia
178Centrifugal Sand cast iron S&S pipe as per iS : 3989
17975 mm dia
180Centrifugal Sand cast iron S&S pipe as per iS : 3989
181Providing and fixing heel rest sanitary bend
182100 mm dia
183Providing and fixing collar :
184100 mm dia
185Sand cast iron S&S as per IS - 3989
18675 mm dia
187Sand cast iron S&S as per IS - 3989
188Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.
18915 mm dia. nominal bore
19020 mm dia. nominal bore
19125 mm dia. nominal bore
192Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
19325 mm dia nominal bore
19432 mm dia nominal bore
19540 mm dia nominal bore
196Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
19720mm nominal bore
19825 mm nominal bore
19932 mm nominal bore.
20040 mm nominal bore
20165 mm nominal bore
202Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete
20320mm nominal bore
20425mm nominal bore
205Providing and fixing uplasticised PVC connection pipe with brass unions
20615 mm nominal bore
207Providing and laying flanged C.I. standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 :
208Up to 300 mm dia
209Providing flanged joints to double flanged C.I./ D.I. pipes and specials, including testing of joints :
210100 mm diameter pipe
211For Sluice Valves and Other specials
212Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :
213100 mm diameter
214Class II
215Providing and fixing G.I. Union in G.I. pipe including cutting andthreading the pipe and making long screws etc. complete (Newwork) :
21615mm nominal bore
21720mm nominal bore
21825m nominal bore
21965 mm nominal bore
220Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
221Providing and fixing C.P. brass bib cock of approved quality conforming to IS : 8931 DSR 18.49
22215 mm nominal bore DSR 18.49.1
223Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931 DSR 18.53
22415 mm nominal bore DSR 18.53.1
225Providing and fixing of Extension nippple upto 1-1/2\\" length
226Providing and laying D.I. specials of class K-12 suitable for push-on jointing as per IS : 9523 :
227Up to 600 mm dia
228Providing push-on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and the cost of rubber gasket :
229100 mm dia pipes
230Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 :
231100 mm dia Ductile Iron Class K-7 pipes
232Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
233150 mm diameter S.W. pipe
234Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :
235150 mm diameter S.W. pipe
236200 mm diameter S.W. pipe
237Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
238100x100 mm size P type
239With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
240Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
241250 mm dia. R.C.C. pipe
242Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality
243HD - 20
244Circular shape 560 mm internal diameter
245MD - 10
246Square shape 450 mm internal dimension
247E & M
248Supplying & installing following sizes of perforated Hot Dipped Galavanised Iron cable tray (Galavnisation thickness not less than 50 microns) with perfoaration more than 17.5 % in convenient sections, joined with connectors, suspended from ceiling with GI suspenderes including GI Bolts & nuts etc. as required
24950mm(H) x 300mm(W) x 50 mm(H) and 1.5 mm Thick
25050mm(H) x 150mm(W) x 50 mm.(H) and 1.5 mm Thick
251Supplying & installing following sizes of perforated Hot Dipped Galavanised Iron cable tray \\"bends\\" (Galavnisation thickness not less than 50 microns) with perfoaration more than 17.5 % in convenient sections, joined with connectors, suspended from ceiling with GI suspenderes including GI Bolts & nuts etc. as required
25250mm(H) x 300mm(W) x 50 mm(H) and 1.5 mm Thick
25350mm(H) x 150mm(W) x 50 mm.(H) and 1.5 mm Thick
254Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required
255Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)
256Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520
257Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.
258M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.
259Suitable cement concrete foundation duly plastered and with anti vibration pads.
260450 lpm at 35 m Head
261Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
26225 mm dia
26340 mm dia
26450 mm dia
26565 mm dia
26680 mm dia
267100 mm dia
268Supplying and fixing single headed internal hydrant valve with instantaneous Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank cap and chain as required :
269Single headed Stainless steel
270Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
27180 mm dia
272100mm dia
273Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
274Stainless Steel (Grade 304)
275Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.
27620 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585
27720 mm nominal internal dia gun metal globe valve & nozzle.
278Drum and brackets for fixing the equipmets on wall.
279Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
280Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
281Stainless Steel (Grade 304)
282Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
2832 way-100 mm dia M.S. Pipe
284Supplying and fixing air vessel made of 250mm dia, 8mm thick MS sheet, 1200mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required
285Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 °C with required accessories :
286Pendent Sprinkler
287Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.
2881000 mm
289Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
290DUCTING, GRILLS,DIFFUSER AND INSULATION
291Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, Splitler dampers,vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required and shall also confirm to the BIS specifications.
2920.63 mm (24 gauge) GSS
2930.80 mm (22 gauge) GSS
294Supplying, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps,collars etc as required complete in all respect in confirmation with IS : 655 and approved drawings and specifications of following sheet thickness complete as required.
2950.80 mm (22 gauge) GSS
296Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volumecontrol damper with enthalpy sensor and necessary control wire for integration within AHU room complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in confirmation to SMACNA/IS and as per specifications complete etc. as required.
297Fire damper
298Actuator
299Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications
300Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required
301Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
302Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.
303Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber ( Class \\"O\\" ) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints should be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
30419 mm
305Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
30612.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
30728.58 mm dia (OD) (Hard drawn) withtube thickness 1.2 mm
308Providing and fixing of Openable MS Cover for UGR with locking arrangement and frame made from MS Angle and Sheet, duly painted with two coats over primer complete to the satisfaction of EIC
309Supplying, lowering, testing and commissioning of Openwell Submersible Pump 10 HP of approved make complete.
310Manufacturing, Supplying, Testing, Commissioning of Electrical Control Panel suitable for operation of 2 no's Submersible Pump Single or Both, independently at a time, complete with Voltmeter, Ammeter, Selector Switch, Indicator, MCB, Starter to the satisfaction of EIC
311Supplying, fixing, testing and commissioning of CI , Swing Type, Non Return Valve of size 100 mm of approved make complete.
312Supplying and laying of UPVC Pipe for Underground drainage and Sewerage, IS - 1538 approved make, complete with cost of solvent to the satisfaction of EIC
313110 mm Nominal Dia
314160 mm Nominal Dia
315200 mm Nominal Dia
316Providing and fixing of Chinaware One piece EWC with slim soft close seat cover make CERA model Campbell or equivalent Model of any other approved make to the satisfaction of EIC
317Providing and fixing of Chinaware Two Piece Wall Hung Extended EWC Cistern with Twin flush fittings Campbell with slim soft close seat cover or equivalent Model of any other approved make to the satisfaction of EIC
318Providing and fixing of white vitreous chinaware urinal partitions of size 90x320x720 mm complete in all respect Make M-cera S4090101
319Providing and fixing of Chinaware Urinal of size 375 x 390 x 590 mm , CERA Capriana of equivalent model of other approved make.
320Providing and Fixing Chinaware Basin of following type / Make / Model or equivalent model of other approved makes Jaquar / Hindware / Kerovit
321Counter Top BasinMake CERA Model Clair
322Table Top Make CERA model CAFÉ
323Wall Hung with half pedestal Make CERA Model Clair
324Providing and fixing of Pressmatic Pillar Cock for Basin complete in all respect of make Jaquar / CERA / Hindware / Kerovit
325Providing and fixing of Self closing angle cock pressmatic for urinal with wall flange and 200 mm connecting pipe and spreader complete of approve make and model
326Providing and fixing of Spout as per approved design for water spouts
327Providing and fixing of looking glass mirror 5mm thick of approved make with PVC beading 1-1/4\\" x 3/4\\" with plastic Hard Board duly fixed on wall with screw/nuts/clips/rod plug
328Providing and fixing Mild Steel Grab Bar capable of moving to different position sitting to standing make Viking Model 56631 or equivalent
329Providing and fixing 32\\" dia ABS Grab Bar 24\\" long make Viking Model 56597 or equivalent
330Providing and fixing of Liquid Lotion Dispenser ( Wall Mounted ) of make Viking or equivalent to the satisfaction of EIC
331Capacity 200 ml
332Capacity 500 ml
333Supplying and Installation of 400 Ltrs Capacity Drinking Water Cooler having (+10%) following specification, full body stainless steel SS 304, ISI marked of approved make
334Storage Capacity: 400 Ltrs
335Cooling Capacity: 150 LPH
336Tank Material: SS 304, Body SS
337BIS Approval IS 1475
338Make Blue Star/Voltas/Climatrol approved by BIS
339Supplying & Fixing of Water Purifier with 3 Stage Purification system consisting of sediment filter, Activated Carbon Filter and Ultravoilet treatment having purification capacity of 200 LPH, water control sensor for automatic control of purifier as per level of water cooler and valve for back flushing of sediment filter complete of make Aquaguard to the satisfaction of EIC
340Supplying & Fixing of Voltage Stablizer with MCB, Voltmeter, Ampere Meter Copper Wound complete of approved make capacity 4 KVA
341Providing and fixing of HCI P.Trap complete in all respect
342100 mm
34375 mm
344Providing and fixing of G.I Tank Nipple complete in all respect
34525 MM
346Providing and fixing polished CP/SS P-Trap/Bottle Trap for Wash Basin complete of approved make to the satisfaction of EIC
347Providing and fixing of C.P. Steel Grating Heavy (With / without hole) size 4\\" i/d of approved make.
348Providing and fixing of Drip Seal Joint to CI Pipes and Specials
349100 mm
35075 mm
351For Control of Terrace Pumps
352HOSE CABINET FOR 15 MTR. LONG HOSE REEL PIPE & BRANCH PIPE ETC.
353Providing and fixing of HOSE CABINET of Size: (600mm x 600mm x 450mm) made of 16 gauge MS sheet with 4mmthick glazed glass door i/c necessary locking arrangement suitable to accommodate 15 mtr. long hose reel pipe & branch pipe mounted on wall or raised bric platform & duly painted with Post office red externally and white internally with synthetic enamel paint complete in all respect as required of approved make.
354Supplying and fixing MS chequred Plate 5mm thick inclduing cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete in all respects
355Fabrication, Supply, Installation, Testing and Commissioning of Electrical Control Panel of cubical construction, Floor/Wall Mounted type, Fabricated out of 2 mm thick CRCA Sheet, compartmentalized with hinged lockable door, dust and vermin proof, powder coated of approved shade , interconnection with suitable size copper condutor cable,having switchgears and accessories mountings and internal wiring, earth terminals, complete in all respect, suitable for Terrace Pump of 7.5 HP Capacity, complete as per CPWD specifications with the following Incoming/outgoings suitable for operation on 415 V / 3 Phase, 50 Hz Supply with enclosures protection.
3564 Pole MCB/TPN 40 Ampere Voltmeter with Selector Switch Ammeter with Selector Switch & CTs etc LED Type RYB Phase Indicating lamps, ON/OFF, Trip Indicating Lamps
357Starter suitable for 7.5 HP Pump with overload protection, Single phase preventor, complete with all accessories Internal wiring required and Sensor for automatic operation Selector Switch for auto/manual/off operation
358Supplying, installing, testing and commissioning of Copper Conductor Cables, XLPE Insulated, unarmoured IS 7098 (Part 1) marked of approved make Havells, Finolex, Polycab to the satisfaction of EIC
3592C x 1.5 Sqmm
3603C x 2.5 Sqmm
3614C x 4 Sqmm
362From Mains to Electrical Panel
363Supplying, installing, testing and commissioning of C.I. Dual Plate Wafer type Non-return Valves PN 16 with SS 304 discs with Nitrile rubber lining as per with required flanges, nuts, bolts and gaskets etc. complete.
364100mm dia.
365Providing and fixing of G.I. tank Nipple Complete in all respect
36625 mm dia nominal bore
36765 mm dia nominal bore
368Supply, Installtion, Testing and Commissioning of Air Cooled Ducted split type air conditioning units with Scroll comperessors and first charge of refrigerant R410A or equivalent permitted green refrigerant, Cooling Coil of Copper with aluminium fins complete of approved make, to the satisfaction of EIC.The rates quoted should include lifting, shifting and positioning of Indoor and Outdoor unit as per site requirements, making hanging arrangement for Indoor Units and hanging arrangement/foundation for outdoor units. The units should be factory charged, however any top up required, Nitrogen leak testing, Oil Charging, Vacuumization, Canvass Connections should also be included in the rates quoted.Make Daikin, Voltas, Bluestar, Carrier, Toshiba
3698.5 TR (+/- 5%)
370Providing and fixing of UPVC Pipe of Class 5 (10KG/CM2) of various sizes for condensed water drainage from Indoor unit to nearest disposal point as per site to the entire satisfaction of EIC.
371All necessary ,Supports ,civil works like cutting & chasing of walls/floor/ glass etc. and make them good thereof should be included in the rates quoted.
37240 mm dia with 6mm Class O Nitrile Insulation
37332 mm dia with 6mm Class O Nitrile Insulation
374Providing and fixing of LT Control Cable Copper, XLPE Insulated PVC Shielded unarmoured complete in all respect.
3754 core x 16 sqmm Aluminium Armoured
3764.0 core x 6 sqmm Copper Armoured
3774 core x 2.5 sqmm copper flexible
3784 Core x 1.5 sqmm
379Main Electrical Panel-1 (CPRI Approved)
380Design,Supply,Installation,Testing and Commissioning Electrical Main Panel weather Proof outdoor Type Powder Coated Made out of TATA/SAIL/ESSAR/JINDAL/Reputed make sheet having thickness 2.0 mm for load bearing surfaces & 1.6 mm Non bearing surfaces duly processsed powder coated having Siemens grey colour or as approved by client or department (Outdoor Type with weatherproof canopy design)as per following specifications complete in all respect .
381INCOMING SUPPLY
382100-160Amps ,3Pole MCCB,36 KA with Microprocessor release.The MCCB shall be double break & the ICS=100% ICU = 1nos
383Spreader Link with phase Barriers = 4sets
384Rotary Mechanism = 1nos
385Metering Section
386Load Manager EM6400NG with RS485 Port or Equivalent (Class 1.0, with RS485 Port, with Paramenters V, Amp, PF, % THD, F,W,WH,VA,VAH, VAR,VARH, Runhrs, ON hrs, Interupts = 1No.
387Control MCB SP C Curve= 3nos
388CT's 200/5 = 3nos
389Indication Lamps LED Type RYB = 3nos
390Outgoing Feeders - (4 Nos + 1 Spare )
391MCB TPN32- 40 Amps C Curve 10 KA -5nos
392ELCB 32-40 Amps 300 MA 4 Pole -5 Nos or as Required by OEM
393Outgoing Feeders - (4Nos + 1 Spare )
394MCB TPN 16 Amps or as per IDU rating C Curve 10 KA -5nos
395Multi function Meter EM 64xx 1.0 RS or equavalent for EMS/BMS compatibilty - 5 nos
396INDICATING LAMPS LED Type
397Control MCB SP C Curve for control
398CT's 30/5
399PANEL
400Fabrication of Powder Coated Enclosure made out of approved/reputed make CRCA sheet having 2 mm for load bearing surfaces & 1.6 mm for non load bearing surfaces ,duly processsed powder coated having Siemens grey colour. (Outdoor Type with weatherproof canopy design)
401Assembly charges of Aluminium Bus Bar 250A TPN Electrolite grade E91 having Suitable cross section Phase & Neutral & Current carring capacity 1 A/Sq. mm2. inclusive of Insulators, colour coded Heat shrinkable Insulation sleeve (RYBN)
402Assembly of Hardware (PVC Channels/MCB Channels/Fibre-Glass/Gaskits/nuts/Bolts/washers/ Terminal blocks, etc)
403Complete Wiring inclusive of control wiring, power wiring, Aluminium Solid connections/interconnections including insulators, thimbles,etc
404Unloading at site, placement of Panel on the foundation, co-ordination during execution, rendering necessary guidance for execution, supervision, testing, commissioning and startup of above mentioned Panel.
405AMC FOR 03 YEARS AFTER DEFECT LIABILITY PERIOD OF 24 MONTHS (02 YEARS) FROM THE DATE OF HANDING OVER THE SYSTEM.
406Comprehesive Maintenance charges for Air Conditioning system including (routine and preventive maintenance with parts including consumables such as gas, oil, filters) and break down maintenance of high & low side of the air conditioning system comprising of all the machinery during FIVE years after expiry of Two year defect liablity period.
407Maintainence
4083rd year (1.5 % of Capital Cost)
4094th year (add 10% on 3rd Year maintenance cost i.e. 40,517/-)
4105th year (add 10% on 4rt Year maintenance cost i.e. 44,569/-)
411ELECTRICAL WORK
412SCHEDULE-A (ELECTRICAL INSTALLATION)
413DSR item No.1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
414Group C
415DSR item No.1.17 Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
4163 x 1.5 sq.mm
4173 x 2.5 sq.mm
4183 x 4 sq. mm
419DSR item No.1.18 Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
4202 Pair
421DSR 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
422DSR item No.1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
423Telephone Socket
424DSR 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
425DSR 1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
426DSR 1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
4271 or 2 Module (75 mm x 75 mm)
428DSR 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
429DSR item No.1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
430DSR 1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
431DSR 1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
432DSR item No.2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
433100 A,30KA,FPMCCB
434125 A,36KA,FPMCCB
435200 A,36KA,FPMCCB
436DSR Item No. 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without (MCB/RCCB/Isolator)
4374 way (4 + 12), Double door
4386 way (4 + 18), Double door
439DSR Item No.2.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required).
4408 way (4 + 24), Double door
441DSR 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
442Single pole
443Triple Pole
444Triple pole and neutral
445DSR item No.1.57 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
446DSR 2.24 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required.
447For 4 way, Double door TPN MCBDB
448DSR item No.2.25 Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required
449DSR 5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
450DSR item No.5.12 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
451DSR 11.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4524 X 16 sq. mm (28mm)
4533 ½ x 35 Sq mm ( 32 mm)
4543 ½ x 120 Sq mm ( 45 mm)
455DSR item No.15.16 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
45663 mm dia (OD-63 mm & ID-51 mm nominal)
45790 mm dia (OD-90 mm & ID-76 mm nominal)
458Civil DSR 10.18 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
459DSR item No.8.7 LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) (Recessed/ Surface type)
460Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5°C to 40°C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K
461(As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C)
462Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)
46336 watt
464DSR item No.8.1 LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt )
465Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5°C to 40°C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI > 80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K
466(As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C)
467Powder coated die cast /Extruded aluminium Body including trim
46822 watt
469DSR item No.8.9 LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).
470Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5°C to 40°C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI > 80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K
471(As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
472Powder Coated CRCA Sheet Body (Thickness ≥ 0.50 mm)
47324- 26 Watt
474DSR item No.8.16 LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt).
475Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5°C to 50°C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI > 70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K
476(As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
477100 watt
478DSR item No.9.2 Brush Less Direct Current (BLDC) Fan without Remote
479Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req.
4801400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum)
481Supply and fixing of 12 modules (200 mm x 150 mm) G.I box suitable for accommodate the following accessories along with modular base and cover plate for modular switches in recess/ surface etc as required for Computer Point with 4 Nos. 5/6 Amp. modular switch and 4 Nos. 3 pin 5/6 Amp. modular socket outlet. The job includes the cost of making interconnections with suitable copper wire, painting of box with approved paint and other petty material required to complete the job to the entire satisfaction of Engineer-in-Charge at site. The Modular accessories should be of Lauritz Knudsen (Entice) / ABB (Ivie) / Legrand (Myrius) / Crabtree (Athena)/ Norisys (Square series) make only.
482Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making the hole to suit the size of above fan making good the damage, Carriage Charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of Engineer-in-charge.
483Size 12 inch (300mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver of Havells (Turbo Force SP) / Orient (Industrial Heavy Duty)/ Usha (Turbo HDEF)/ Crompton (EXHD300-6-1)/ Bajaj (Supreme Plus) make only.
484Supply & fixing of OEM made Junction box IP-66/67 made out of Polycarbonate with Glass fiber reinforced of size 210x155x90 (minimum) with 5 nos. OEM made connectors/ terminal blocks. The Jn. Box and connectors/ terminal blocks should be supplied by OEM. The terminal blocks/ connectors should be of Hensel/ Wago/ Elmax/ Siemens make only and junction box shall be of Hensel make KF-1616 G or its equivalent Clipsal/ Legrand/ Rittal/ Schneider/ ABB make only. The Junction box shall be fire retardant and self-extinguishing. The gasket material shall be polyurethane and the gasket shall be internally embedded. The job includes the cost of cable glands for cable entry, mounting kit for pipe and post installation, fixing screw, all labour and petty material required to complete the job to the entire satisfaction of the Engineer in Charge of work.
485S/E of angle iron bracket rectangle shape (1 mtr. x 0.6 mtr.) made out of 50mm x 50mm x 5mm with 4\\" dia 45 cm long GI pipe medium class canopy suitable for installation of 4 nos. LED flood lights. The bracket shall be welded to GI pipe canopy at the top of the pole. The bracket shall be provided with suitable size. nut/bolts crossed through out the pole & the bracket complete with washer etc. The angle iron shall have at least 3 nos. holes for erection and adjustment of flood lights. The bracket shall be painted with red oxide and then aluminium paint as required at site. The job includes making holes in pole and bracket at site as per the requirement. The job includes the cost of installation of angle iron bracket with canopy on existing pole upto 9 mtr. height with help of hydraulic ladder / Crain with bucket which shall be arranged by the firm at his own cost. The sample of the bracket is to be got approved at Workshop prior to carriage to site of installation to complete the job to the entire satisfaction of Engineer-in-charge. The GI pipe should be medium class ISI marked of Hindustan / Jindal / Tata / Sail/ Zenith only.
486Supply & erection of Wall Fan 400mm sweep oscillating type complete with blades with regulator. The fan should be of Havells (Swing)/ Usha (MAXX AIR)/ Orient (400mm Wall44)/ Crompton (WM Hiflo wave Plus)/ Bajaj (Esteem Double String) make only. The wall fan should be provided with double string i.e. one no. controlling oscillating and one for speed. The cost including connection with adjacent light points.
487Supply and laying of XLPE insulated PVC sheathed Aluminum conductor armoured cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid in existing Trench/Ducts/Cable Tray/ RCC/ HUME/ METAL/ DWC pipe / on surface with the help of MS clamps of suitable size/ as required at site to the entire satisfaction of Engineer-in-Charge. The job includes labour charges of laying the cable and making connections with suitable size aluminum lugs/thimbles etc. The cable shall be of Polycab / Havells / R.R. Kabel/ KEI/ Finolex make only.
48816 sq.mm 4 core In pipe
48935 sq.mm 3.5 core in pipe
490120 sq.mm 3.5 core In pipe
491Supply and erection of 14 GMS sheet frame of suitable size for erection of 12”/15”/18” sweep exhaust fan. The holder should be suitable for 12”/15”/18” sweep exhaust fan shall be cut from the centre of the sheet and bedding ¼” round collar with round cut and duly fixed with existing ventilator frame with suitable arrangement after removing the existing glass. The exhaust fan frame shall be painted on both side with superior quality paint after one coat of primer. The job includes the cost of M.S. strips of 1”x1/4” and other petty material required to complete the job to the entire satisfaction of Engineer-in-charge.
492S/E of 7 Mtr. long Hot dipped Galvanized pole of octagonal cross-section continuously tapered made out from high tensile steel of minimum thickness 3mm complete with the base plate of minimum size 220mm x220mm x12mm alongwith inbuilt lockable junction box which should be operated with single key with connectors of Elmax / Connectwell / Essen / Wago make for the cable termination as per site requirement and one no. 6 Amps. Single pole MCB for each luminaire. The diameter across from the dimensions of the base and top should be minimum 130 mm and 70mm A/F (Across Face). The size of the poles and foundation bolts shall be suitable to withstand the maximum wind speed/ pressure as per IS-875. There should be no any circumferential welding on the pole. The method and material shall comply with as BSEN-10025 grade S355 or equivalent poles should be hot dipped galvanized in single dip to 65 microns min. confirming to IS 2629-1966. The material and specifications of flange plate/base plate shall be as per IS 2062.
493The street light poles shall be as per IS 2062. The street light poles shall be erected in the existing RCC foundation with 4 nos. special foundation bolts ‘J’ type minimum 700mm long galvanized M.S. rod of duly threaded of minimum 20mm dia in existing RCC foundation of suitable size as per the approved drawing. The material of steel foundation bolts shall be confirming to grade EN-8 exposed threaded portion of foundation bolts shall be hot dipped galvanized. The octagonal pole should be of Bajaj / Transrail / Utkarsh / Valmont/ Salasar make only. (The cost of 7 Meter long S/L octagonal poles is including with 4 nos. x M20 x 600mm long ‘J’ type bolts with nuts, carriage of pole at site & installation complete as required.
494FOUNDATION FOR 7 MTR. LONG OCTAGONAL POLE:
495DSR 2.6 (Civil work)
496Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and for all lift, as directed by Engineer-in-charge.
497All kinds of soil (Size 0.7mx0.7mx1.65m = 0.81 cum (2 Nos. x 0.81cum= 1.62)
498DSR ITEM NO. 4.1 (CIVIL WORK)
499Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
5001:5:10 (1 cement : 5 fine sand drived from natural source : 10 graded stone aggregate 40mm nominal size drived from natural source) (0.7m x 0.7m x 0.10m = 0.05 cum.)
501(2 nos. x 0.05 = 0.10)
502DSR ITEM NO. 5.22.6 (CIVIL WORK)
503Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
504Thermo-Mechanically Treated bars
5051.Vertical Bar 12mm dia =4 nos.x1.55=6.2 r.mtr. @0.89 kg per mtr. =5.52 kg
5062.Horizontal Ring 8mm dia =11 nos.x2=22 [email protected] per mtr.=8.58kg
507Total (5.52+8.58=14.1+5% =14.8
508wastage = 2 nos. x14.81 = 29.62)
509DSR 5.1. (Civil) Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
5101:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources) Size 0.5x0.5x1.55 = 0.388 cum = (2 nos. x 0.388= 0.78 cum.)
511DSR Item No. 5.9.1 (CIVIL WORK)
512Centering and shuttering including strutting, propping etc. and removal of form for :
513Foundations, footings, bases of columns, etc. for mass concrete
514Size 0.5x0.5x1.55
515(0.5 x 1.55) x 4 = 3.1 Sq. Mtr.
5163.1 x 2 = 6.2 Sq. Mtr.
517Supply and erection of sheet metal cubical pedestal of suitable dimensions made from 50 mm X 50 mm X 6 mm thick M.S angle iron frame, covered with 1.6 mm thick M.S. sheet duly welded on five sides and front side hinged complete with locking arrangement with 4 Nos. switchgear supporting members each of M.S. flat 50 mm X 6 mm thick of suitable length duly welded. The cubical pedestal shall have 4 Nos. legs of 50 mm X 50 mm X 6 mm each 60 cm long M.S. angle iron each long including painting, bonding to the existing earth etc. the same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15cm high form ground level and 45 mm thick. The cubical pedestal shall be 15 cm from the top of cement concrete platform.
518Cubical size 1200 mm X 900 mm X 350 mm
519Cubical size 900 mm X 600 mm X 350 mm
520Fabrication, supplying, installation, testing and commissioning of Indoor type cubicle type fully enclosed compartmentalized electric panel of suitable size (300mm-900mm) deep as required as site suitable for three phase 50 Hz 415 volt AC supply system made out of 1.6 mm thick CRCA sheet duly strong thread with suitable size of MS channel members and base weather proof dust and vermin proof, ventilated with louvers at sides removable gland plates at the bottom, earthing studs at both ends duly painted with powder coated finish of approved shade and two coats of anticorrosion paint including providing and fixing of four strip main and auxiliary aluminium bus bars of rating min 200 amp., multifunction meter, LT phase indicator lamp for each incomer/ outgoing, MCB distribution board metering unit and having space for accommodating various MCCB’s, MCB SP, MCB TPN, Change over switch etc as per site requirement. The manufacturer/ fabricator of LT panel should posse’s type test certificate/ reports w.r.t. construction/ manufacturing of LT panel confirming to IS: 8623/93 with breaking capacity 50KA (minimum) & Degree of protection IP42 (minimum) from CPRI /ERDA approved Lab.
521Size 1.7 mtr. X 1.6 Mtr.
522Size 1.7 mtr. X 0.8 Mtr.
523DSR item No. 39.17 Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range: -5° to +60°C. Bending Radius: < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force: 11.5Kg etc. complete as required.
5241 Run of cable
525Supply installation testing commissioning of COB DALI dimmable Recess Down Light Fixture to be installed recess in false ceiling. The fitting should be Philips / Wipro/ Lighting Technologies /Bajaj make only. The job includes the cost of testing, commissioning and making connection with copper wire from adjacent light point. The job includes all labour and petty material required to install the fitting to the entire satisfaction of the EIC of work. The LED fittings should be as per following design criteria.
526TECH. SPEC. OF LED FIXTURE: Recess COB Down Light Fixture DALI Dimmable
527Wattage of LED fittings As per following parametersTotal lumens of the LED fittings Minimum 3300 LumenHousing Die cast aluminiumReflector Anodized aluminium deep recessed reflector for Glare free lightOperating voltage 140 - 270Volt, AC, 50Hz ± 1%Power factor >.95Luminaries efficacy > 110 Lm/Watt or HigherColor rendering index CRI shall be >80Working/ operating temperature 0℃ to 45℃ or betterColor temperature 5700 to 6500 degree KELECTRONIC DRIVERDrive current (LED) As per OEMType of Driver Constant current, Constant Voltage output driverTHD <10%Surge Protection 2.5 KV MinimumDriver Efficiency >85%Protection Over & Under Voltage protectionWarrantee of LED fixture including driver 5 Yrs from the date of InstallationFixture Should comply LM 79 test from NABL or UL accredited LabLED Make Power CREE, OSRAM, NICHIA, Philips LumiLED.Type of LED 50,000 burning hours @ 70% lumen maintenance complying with LM 80 test report
528Life of LED 50,000 burning hours @ 70% lumen maintenance
529Supply installation testing commissioning of LED Flexible Strip to be installed in existing cove of false ceiling/ wooden design with suitable arrangement. The LED Strip should be Philips / Wipro/ Lighting Technologies /Bajaj make only. The job includes the cost of testing, commissioning and making connection with copper wire from adjacent light point. The job also includes the cost of electronics driver required for the LED Strip of the same make as mentioned for LED Strip. The LED fittings should be as per following design criteria.
530TECH. SPEC. OF LED FIXTURE: LED Flexible Strip (5 Mtr Roll)
531Wattage of LED fittings As per following parametersTotal lumens of the LED fittings Minimum 400 Lumens per meterMounting and fixing Self AdhesiveOperating voltage 140 - 270Volt, AC, 50Hz ± 1%Power factor >.95Luminaries efficacy > 80 Lm/Watt or HigherColor rendering index CRI shall be >80Working/ operating temperature 0℃ to 45℃ or betterColor temperature 5700 to 6500 degree K
532ELECTRONIC DRIVER
533Drive current (LED) As per OEMType of Driver Constant current, Constant Voltage output driverTHD < 15 % Surge Protection 2.5 KV MinimumDriver Efficiency >85%Protection Over & Under Voltage protectionWarrantee of LED fixture including driver 5 Yrs from the date of InstallationFixture Should comply LM 79 test from NABL or UL accredited LabLED Make Power CREE, OSRAM, NICHIA, Philips LumiLED.Type of LED 50,000 burning hours @ 70% lumen maintenancecomplying with LM 80 test report
534Life of LED 50,000 burning hours @ 70% lumen maintenance
535Supply, installation, testing, and commissioning of a 6-Watt LED Step Light (recess type) with aluminum die- cast housing in powder-coated grey color and CCT 3000K, complete with an electronic driver. The job includes testing and commissioning to the satisfaction of the Engineer-in-Charge. The fitting should be of Philips / Wipro/ Lighting Technologies /Bajaj make only. The sample of the fixture must be approved by the Engineer-in-Charge prior to site installation.
536Supply, installation, testing, and commissioning of KNX Bus Power Supply suitable for KNX/EIB intelligent building automation system, having input voltage range of 150–275 VAC, 50/60 Hz and providing Output-1 for KNX bus power supply of 30 V DC SELV, 320 mA with integrated choke for supplying and isolating the KNX bus line and Output-2 as additional auxiliary voltage output of 30 V DC SELV. The unit shall be DIN rail mounted type and shall be complete with inbuilt protection against overload and short circuit, integrated reset facility, screw type terminals and LED indications for Power, Overload and Reset status. The power supply shall be suitable for continuous operation in KNX automation networks and compatible with ETS programmed KNX devices. The item shall include all necessary hardware, interconnections, mounting accessories and wiring required for proper installation, testing and commissioning complete as required at site.
537Make: Legrand / JUNG/ ABB/ Siemens only.
538Supply, installation, testing, and commissioning of KNX 4/8 Button Keypad/Control Element suitable for KNX/EIB intelligent building automation system, configurable for multi-functional operation through ETS programming software. The keypad shall be capable of performing functions such as switching ON/OFF of lighting circuits, dimming control, curtain/blind open-close operation, scene recall and control, staircase lighting control and other programmable KNX automation functions as required. The unit shall be modular type with 4/8 independent programmable push buttons/rockers with status indication LEDs and shall support short press and long press configurable operations. The keypad shall communicate through KNX bus and shall be fully compatible with standard KNX protocol and KNX-certified devices. The item shall be complete with bus coupling unit/interface, mounting accessories, flush mounting box compatibility, front plate, programming facility, interconnections and all associated accessories required for proper installation, testing and commissioning complete as required at site.
539Make: Legrand / JUNG/ ABB/ Siemens only.
540Supply, installation, testing, and commissioning of Web-Based KNX Automation Controller/ Gateway for centralized monitoring, integration and control of all connected KNX devices on a single platform through a common user interface/application. The controller shall be capable of integrating and controlling lighting circuits, dimming modules, curtain/blind controls, HVAC systems, scenes, scheduling functions and other connected electrical loads within the KNX automation network. The controller shall support integrated IP, serial and infrared control in a compact single-unit design and shall be suitable for integration with mobile applications, touch panels, remote controls and web-based interfaces for centralized operation and monitoring. The system shall provide a consistent multi-platform user experience with common themes and layouts across touch panels, remotes and mobile applications. The controller shall be based on an ultra-efficient fanless architecture with no moving parts to ensure silent, reliable and long-lasting continuous operation. The unit shall be compatible with KNX protocol and ETS-programmed KNX devices and shall support future scalability through compatible control extenders/interfaces for larger installations. The item shall include all necessary software licenses, gateways, communication interfaces, power supply requirements, mounting accessories, programming, integration, testing and commissioning complete in all respects as required at site.
541Make: Nice ELAN / Legrand / JUNG /ABB/ Siemens only.
542Supply, installation, testing, and commissioning of KNX–DALI Gateway/ Controller suitable for intelligent lighting automation system for integration of DALI lighting network with KNX/EIB building automation system. The gateway shall support control and monitoring of DALI electronic control gear/luminaires through KNX protocol and shall provide one complete DALI universe comprising 64 DALI addresses per control output. The controller shall be available with 1/2/3 DALI control outputs supporting full DALI universes of 64/120/192 addresses respectively, including backward channel communication for status feedback, fault monitoring and real-time control verification. The gateway shall additionally support DMX-512 control functionality for integration of architectural and dynamic lighting systems wherever required.
543The KNX-DALI controller shall have an inbuilt/on-board web server facility for configuration, testing, commissioning and verification of connected lighting loads through web-based interface without requiring additional external software. The unit shall support switching, dimming, scene control, group control, scheduling, status monitoring, emergency lighting integration and programmable automation functions through ETS software and DALI commissioning interface. The gateway shall be DIN rail mounted type and fully compatible with standard KNX and DALI protocols.
544The item shall include all necessary interfaces, communication modules, addressing/ programming accessories, software integration, mounting hardware, wiring terminations and all associated accessories required for proper installation, testing and commissioning complete in all respects as required at site.
545Make: Legrand / JUNG/ ABB/ Siemens only.
546DSR item No.4.1 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastner etc as required.
547300 mm width X 50 mm depth X 1.6 mm thickness
548DSR Item No.1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
5494 X 6 sq. mm + 2 X 6 sq. mm earth wire
550SCHEDULE-B (DG SET)
551DSR item No.29.1
552Supplying, Installation, Testing & Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings:
553(A) Diesel Engine: Turbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40⁰C, 50% RH & at 1000 Meter MSL, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications.
554B) Engine mounted Instrument Panel fitted with and having digital dis Plate for following:
555Start-stop switch with key
556Water temperature indication
557Lubrication oil pressure indication
558Lubrication oil temperature indication
559Battery charging indication and Voltage indication
560RPM indication
561Over speed indication
562Low lubrication Oil trip indication
563Engine Running Hours indication
564Fuel Level
565(C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40⁰C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self-cooled, self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.
566(D) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.
567(E) FUEL TANK: Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.
568(F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor.
569(G) Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set.
570(H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications.
571(I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyzer to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/ SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following:
5721. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip.
5732. Auto/Manual/Test/Off selector switch
5743. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay).
5754. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering
5765. Energy analyser unit to indicate current, Voltage( L N & L_L), kW, kVA (Phase & Total), Frequency, KWH, PF.
5776. LED Indicating lamps for load on mains and load on set
5787. Fuse/ MCB for instruments
5798. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.
5809. Main supply failure monitor
58110. Supply failure timer
58211. Restoration timer
58312. Control unit with three impulse automatic engine start/stop and failure to start lockout.
58413. Impulse counter with locking and reset facility.
58514. ON/OFF/Control circuit switch with indicator
58615. Audio/Video annunciation for
587(i) High water temperature
588(ii) Low lubricating oil pressure
589(iii) Engine over speed
590(iv) Engine fails to start
591(v) Full load/maximum load warning
59216. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories
59317. Maintenance notification based on Engine Run Hour & due date.
59418. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel, interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring.
59562.5 KVA
596FOUNDATION FOR DG SET
597DSR 2.6 (Civil) Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and for all lift, as directed by Engineer-in-charge.i) All kind of soil.
598DSR 2.27 (Civil) Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
599DSR item No. 4.1.11 (Civil) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
6001:5:10 (1 cement: 5 fine sand derived from natural sources: 10 graded stone aggregate 40 mm nominal size derived from natural sources).
601DSR 5.22 (Civil) Steel Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.
602Thermo-mechanically treated bars of grade Fe-500D or more.
603DSR 5.1 (Civil) Providing and laying in position specified grade of reinforced cement concret, excluding the cost of centering, shuttering, finishing and reinforcement- All work upto plinth level:
6041:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural source: 4 graded stone aggregate 20 mm nominal size derived from natural sources) .
605DSR 13.1 (Civil) 12 mm cement plaster of mix:
6061:4 (1 cement: 4 fine sand)
607DSR Item No. 5.9 (Civil) Centering and shuttering including strutting, propping etc. and removal of form for :
608Foundations, footings, basis of columns, etc. for mass concrete.
609DSR 12.1.1 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
6101.00 mm thick with zinc coating not less than 275 gm/m²
611DSR 10.25 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
612In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
613DSR item No.5.4 Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (with charcoal/coke and salt) as required.
614DSR item No.5.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
615DSR 11.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
6163½ X 50 sq. mm (35mm)
617DSR item No.15.16 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
61863 mm dia (OD-63 mm & ID-51 mm nominal)
619Supply and laying of XLPE insulated PVC sheathed Aluminum conductor armoured cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid in existing Trench/ Ducts/Cable Tray/ RCC/ HUME/ METAL/ DWC pipe / on surface with the help of MS clamps of suitable size/ as required at site to the entire satisfaction of Engineer-in-Charge. The job includes labour charges of laying the cable and making connections with suitable size aluminum lugs/thimbles etc. The cable shall be of Polycab / Havells / R.R. Kabel/ KEI/ Finolex make only.
620Size 50 Sq. mm 3.5 core (In pipe)
621SCHEDULE-C (UPS)
622DSR item No.26.2 Online UPS- Input supply: Three Phase, Output supply: Three Phase
623Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) at operating temperature 0 to 40 deg C, Relative humidity 0 to 95%, Online double conversion true sine wave Uninterrupted hot swapable (allow for the replacement or addition of battery modules without shutting down the entire system) modular Power Supply (UPS) system with N+1 modules (N denotes total number of modules required for rated capacity). The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch alongwith manual bypass, suitable isolation transformer for additional protection against neutral faults etc. UPS shall have inbuilt phase sequence correction. The UPS systems offered are to be of the latest technology with Digital Control Microprocessor based for reliable operation using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter (3 Level) with PWM (Pulse Width Modulation). The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE.
624The operating efficiency of the UPS systems shall be ≥96% while operating on battery mode and delivering quality power to the 100% non-linear loads. Current total harmonic effect (ITHD) on the input grid shall be < 5% at 50 %load. (The required LC (inductor (L) and a capacitor (C)) filters shall be included in UPS cost), extreme power factor kit to be included to limit the input power factor (PF) to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1), however UPS shall be suitable to take load at 0.7 lagging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC: 3Phase 400V +/-20%, 50 Hz +/-5 Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins, Sine wave output. Non condensing, noise level less than 60db at 1 meter distance, protections: Input Under voltage over voltage, abnormal out voltage, battery over charging, output over current, short circuit protection, battery deep discharge protection, 10KV surge. UPS must comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI)-type UPS. Communication RS232/RS485/SNMP port open protocol for BMS integration, all hardware & software for iOT Communication as per approved by Engineering in charge.
625Required battery racks and interconnecting copper conductor cables of suitable size and connectors and all required accessories are inclusive of the cost). This system must provide a means for logging and alarming of all monitored points plus email notification. Forced air-cooling with integral inbuilt fans with redundancy (if one fan fail UPS should be able to handle at least 80% of the load, Noise Level 65 DB at 1 meter distance. The system shall be in compliance IEC 62040- 1,2 & 3, IS: 16242 and CPWD Specification. Display Panel (minimum) (In-build 5 inch or more LC Display / LED) to display: a) Input: Voltage, current, Frequency. b) Bypass: Voltage, Frequency. c) Output: Voltage, frequency, Current. d) Battery: Voltage, Capacity. e) Load: KVA, KW, Percentage. f)Temperature: STS, Inverter, PFC. g) Event Logging & Statistical Data (On LCD/LED): UPS should capture
626and display up to 3000 events like: Over temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-circuit / Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) Statistical Data: No. of power failures / Transfers to Bypass / Total Running time, etc. i) Mains Mode of Operation /Battery Mode of Operation / Bypass feeding the load / UPS Fault /Battery charging and discharging, overload, battery voltage and battery capacity. j) Audible Alarms : Mains Failure, Battery Low Alarm, UPS Overload, Fault, Shutdown, Input Over, Under Voltage, Output Over, Under Voltage, Battery Over, Under Voltage, Over Load and short circuit, Over Temperature. The UPS should have QR code which should contain drawing, test report OEM manual, Geo-tag of manufacturing location etc.
62740 KVA (Each Power module shall be ≤ 10 KVA)
628DSR item No.2.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
62912 way (4 + 36), Double door
630DSR item No.2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
631Single pole
632Triple Pole
633DSR item No.5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
634DSR item No.5.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
635DSR item No.2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
636100 A,30KA,FPMCCB
637DSR Item No.1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
6384 X 16 sq. mm + 2 X 6 sq. mm earth wire
639SCHEDULE-D (FIRE ALARM SYSTEM)
640DSR item No.1.17 Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
6412 x 1.5 sq.mm
6423 x 1.5 sq.mm
643DSR 1.20 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
64425 mm
645DSR item No.1.18 Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
6462 Pair
647DSR 28.1.4 Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
648DSR 28.1.7 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
649DSR item No. 28.1.8 Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required.
650DSR 28.1.11 Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required.
6516 zone panel for fire alarm system 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required- 2 Nos. (one to act as standby) Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set.
652Announcement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set. Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch -1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt, 30 AH each sealed maintenance free batteries -1 set.
653DSR item No. 28.5.3 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.
654speaker cable Single pair, 2-core, 1.5 sqmm
655Supply and installation of Red/ Green LED Laser etched emergency exit signage‘s double sided pendant type made out of powder coated MS housing and etched acrylic sheet indicator with reflective light source> 2W LED, Emergency Backup of minimum 4 hours, 6V 3.2 AH SMF/ SLA battery, SMPS Power supply suitable for operation on 230 AV 50 Hz AC supply as per the requirement at all prominent locations to guide the way out of the building to the building users in case of fire. The size of the letter should be sufficient for visibility of the people as per NBC-2016. The exit sign board should be of THORN/ PROLITE/ AUTO GLOW/ AUTOLITE/ GLOWLITE/ HONEYWELL make only.
656Supply, installation, testing and commissioning of 2x10 watt wall/ceiling mounted industrial Double Beam emergency LED light with exit sign board. The fitting should have CRCA steel housing, 5700K color Temperature, 50000 burning hours, minimum emergency backup of 4 to 5 hours. The fitting should be fully automatic i.e. automatic on in case of normal supply failure and automatic off as power resumes. The battery should have inbuilt protection for over, under charge and short circuit protection. The job also includes the cost of testing commissioning and making connections with 3x1.5 copper conductor from adjacent light point, other petty material and labour etc. as required to complete the job to be entire satisfaction of Engineer-in-Charge. Make: Mr. Lite/ Agni/ Edvent only. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58513236
AUTHORITY Local Bodies
TENDER VALUE 12.41 Crore
LAST DATE 26-11-2026
Authority
Authority Name Chandigarh Administration Engineering Department
Work Description Tender for Development Of City Forest At Colony No.4 Sukhna Choe Forest Industrial Area Phase-1, Chandigarh
Basic Detail
Tender No CP6/2026/2250-2262/SUKHNACHOE
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 13 Nov 2026
Submission Date 26 Nov 2026
Open Date 26 Nov 2026
Finance
Tender Value 12.41 Crore
Tender Fee Ref. Documents
EMD 22.41 Lakhs
Exemption Not Available
Document List
BOQ_119132.xls
ca750178-1728-402c-8f37-bd15ffd83306.html
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Nov 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_119132.xls

html

ca750178-1728-402c-8f37-bd15ffd83306.html

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender