Tender For Replacement Of Bearing, Sleeve And Some Spare Parts Of Pump Unit No.-1 & 2 And Replacement Of By Pass Contactor Coil With Ancillary Works At Gayeshpur Clear Water Booster Pumping Station
Tender Value
4.43 Lakhs
Estimated cost
Bid Submission
20 Nov 2026
0 days left
EMD
8873
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Replacement Of Bearing, Sleeve And Some Spare Parts Of Pump Unit No.-1 & 2 And Replacement Of By Pass Contactor Coil With Ancillary Works At Gayeshpur Clear Water Booster Pumping Station
BOQ
| Sl. No. | Item Description |
| 1 | Disconnecting the LT power line from motor terminal & necessary closing of suction & delivery valves, lifting the horizontal pump from the existing place with proper care by using overhead crane and placing at working floor as per direction of the EIC |
| 2 | Dismantling of horizontal pump after decoupling from the motor & loosening /cutting the nuts,bolts, washers, bearings & its housing from DE & NDE portion of pump along with removing of spares such as bearing cove jamnut, separator gland packing,SS sleeve etc. to be taken out from the shaft very carefully as per direction of EIC. |
| 3 | Dismantling & taking out carefully the impeller unit of pump from casing carefully & placing it on the working bay as per direction of EIC |
| 4 | Hiring charges for transportation vehicles (TATA 407 or equivalent) incl. driver, helper, fuel,mobil all complete with all materials handling accessories,all necy valid documents as per MV rules and to be used from workshop to site incl. for carrying out the materials used for the job as per direction of E.I.C |
| 5 | Supplying & replacement of following consumable materials for minor maintenance of all the electro-mechanical equipments |
| 6 | a) Grease |
| 7 | b) Gland Packing (12/20 mm) |
| 8 | Replacement of bearing (Bearing no-6312 -2RS1/C3),Make:-SKF |
| 9 | S,D & Fixing Neoprene rubber bush as per direction of EIC |
| 10 | Supply & fixing of pump top cover gasket |
| 11 | Manufacturing of SS Shaft Sleeves and key nuts for the DE and NDE and machining and threaded as per sample specification 225 mm long x 80 mm inner dia x 120 mm outer dia including necessary transportation cost and less cost of old damage dismantled materials as per direction of EIC. |
| 12 | Under cut of damaged NDE side bearing housing portion,metal deposition on the under cut surface,machining,turning & polishing with proper tolerance according to the size of bearing outer.Work should be completed in all respects up to the satisfaction of E.I.C. |
| 13 | S & D 12 X 70 mm Dowel Pin |
| 14 | S & D 24 X 150 mm High Strength Structural Bolt |
| 15 | S & D 20 X 120 mm High Strength Structural Bolt |
| 16 | Reassembling & refixing the all accessories bearings,bearing cover, gland packing after replacement of electro-mechanical damage parts and spares mentioned above with all accessories on the impeller shaft of pump carefully with the arrangement of proper tools & tackles /machinaries, shaft and spares should be throughly cleaned,polished and bearing to be properly lubricated with suitable grade lubricant as per direction of the EIC. |
| 17 | Re-fixing of impeller after dynamic balancing in workshop as per I.S rule after dismantling the same. |
| 18 | Installation,aligning the HSC centrifugal pump-motor set after necessary adjustment, testing, checking and commissioning of horizontal pump motor set incl. lowering down the pump set in existing place (well/pit) with the help of using overhead EOT crane.This item also includes the arrangement for Chain Pulley block, tools, tackles, sundry materials . |
| 19 | Supply,delivery & replacement of Contactor coil of By-Pass Contactor for motor feeder no-01,Model:-AF 580A, Make:-ABB or equivalent |
| 20 | Supply,delivery & laying 3.5C X 120 Sqmm Al conductor unarmoured Cable as per direction of EIC |
| 21 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.:3½ X 120 sq. mm (45mm) |
| 22 | Taking down the heavy duty exhaust fan 1ph 23 cm sweep to 60cm sweep with necessary tools and tackles and arrangement from top of the wall |
| 23 | Opening the 1ph 24\\" or 60cm sweep exhaust fan,testing, checking,re-winding by supplying super enameled copper wire of appropriate gauge,minalex paper,mica sheet,changing the loops,overhauling, becking,varnishing,re-fitting and testing and measuring r.p.m etc. |
| 24 | Opening the heavy duty 24\\" or 60 cm Exhaust fan testing,checking,servicing and overhauling including supplying 1.5sqmm PVC Copper flexible wire up to length 0.5 Meter. Including transportation charges etc. and refitting the same. |
| 25 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required:2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 26 | Supplying of approved make 500mm sweep Pedestal fan oscillating type with base, blades, guard, speed regulator etc. AC 230-250 Volts |
| 27 | Supply & fixing of 230/240V, LED indicating lamp.(Make :AE/KAPPA/IMP) other than Blue/ white color. |
| 28 | Taking down the Ceiling fan 900 / 1200/ 1400 mm sweep (GEC/Crompton/ Usha/ Havells etc.) with necessary tools and tackles from ceiling |
| 29 | Opening the Ceiling Fan testing,checking and Re-winding by supplying super enamelled copper wire of appropriate gauge,minilex paper,mica sheet, changing the loops, overhauling , backing,varnishing,re-fitting and using and measuring r.p.m for ceiling fan above 36\\" sweep upto 60\\" sweep. |
| 30 | S&F LED lamp incl. best quality LED lighting arrangement to be fixed by proper arrangement with complete connection.(1 module contain 3 nos LED,0.5W Each) |
| 31 | S & F Water proof 200 Watt,Model ELG 200 power supply system IP65,Output voltage :12V/24V DC,50/60Hz frequency,108 to 305 VAC Power supply>0.95 power factor for LED lamp(Make:-Meanwell) |
| 32 | Supply,delivery & fixing (5 KVAR X2 Nos ) 10KVAR of Ultra Heavy Duty Capacitors Cylindrical Series 440V (Make: L & T/ABB/ Schneider/Simence/ GE) |
| 33 | Add CESS @ 1.00% on Rs. 372259.64 i.e Total amount over item no. 1.00 to 31 |
| 34 | Add GST @ 18.00% on Rs. 375982.24 i.e Total amount over item no. 1.00 to 32.00 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayNov 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender