Tender For Repair / Maintenance /Servicing Of Fire Fighting System Co2 Flooding System, Panels, Smoke Detector System With Its Components And Other Miscellaneous Connected Works At Age E/M-Ii Under Ge (C) Khadki.
Tender Value
39.17 Lakhs
Estimated cost
Bid Submission
08 Dec 2026
22 days left
EMD
78340
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Maintenance /Servicing Of Fire Fighting System Co2 Flooding System, Panels, Smoke Detector System With Its Components And Other Miscellaneous Connected Works At Age E/M-Ii Under Ge (C) Khadki.
BOQ
| Sl. No. | Item Description |
| 1 | M&L for Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for taking out or laying of pipe line and getting out in Hard/dense soil complete all as specified and directed by Engr-in-Charge. |
| 2 | Returning filling in, trenches around pipe line including spreading levelling in layers n.exc 25 cm after laying pipes and well ramming complete all as specified and directed by Engr-in-Charge. |
| 3 | Removal of surplus excavated soil to a distance n.exe. 50 mtr away from site and deposited where directed at a level not exceeding 1.5 mtr above the ground level complete all as specified and directed by Engr-in-Charge. |
| 4 | Dismantling of stone sett paving laid bedded and pointed in cement mortar of any description or thickness complete all as specified and directed by Engr-in-Charge. |
| 5 | Demolition of cement concrete in ground floors and paving n exc 15 cm thickness ( below or above ground level) complete all as specified and directed by Engr-in-Charge. |
| 6 | M&L for cement concrete 1:4:8 type D-2 ( using 40 mm graded agg) as in sub base for stone sett paving complete all as specified and directed upto 100 mm thick finished even and fair complete all as specified and directed by Engr-in-Charge. |
| 7 | M&L for stone sett flooring with stone setts of size 200 to 150 mm long ,150 to 200 mm wide and 150 mm deep and sides dressed, bedded in cement mortar 1:3 joints 20 mm thick ; grouted in cemnt mortar 1:2 with an admixture of metallic floor harder 5% by weight of cement and struck flush complete all as specified and directed by Engr-in-Charge. |
| 8 | All as item no 7.00 above but except stone complete all as specified and directed by Engr-in-Charge. |
| 9 | M&L for flush pointing 20mm thich to stone sett paving any decription in cement mortar 1:3 with an admixture of metallic floor harder 5% by weight of cement complete all as specified and directed by Engr-in-Charge. |
| 10 | Removal of debris ( concrete, broken stone etc.) to out side defence land (distance exceeding 1.5 KM but 5KM from the site ) an depositing where directed complete all as specified and directed by Engr-in-Charge. |
| 11 | M & L for attending complaint for repair/replacment of rusted/broken pipe line, removing leakage of water pipe lines of size 80/100/150 mm Bore pipe of any description such as CI/DI pipe line at any location under AGE E/M-II including necessary welding work, excavation, earth work, dewatering, including repairs with suitable flanges, rubber packing,lead wool or any other packing material complete all as specified and directed by Engr-in-Charge. |
| 12 | All as per item No 12.00 above but pipe size 200 to 350mm Note for item No. 11.00 to 12.00 :- i) Complaint will be notified to contractor on mobile phone at any time between 0800 hrs to 2200 hrs and will be rectified within 12 hours after notification, failing which Rs 500/- per day per complaint will be recovered ii) Cost for Excavation upto required depth, PCC demolition, earth work, PCC work if needed shall be mesured and paid under relavant items of schedule. Contractor should arrange JCB as per the direction of Engr-in-Charge at site. ii) Cost of Pipe, Fittings and mechenical joints if needed shall be mesured and paid under relavant items of schedule. |
| 13 | Supply only Mechanical joint coller coupling long sleeve with rubber washer, mild steel screw bolts (machine made) with both ends screwed of dia as per flange hole and required length each screwed end to be fitted with washers and hexagonal nut suitable for 100mm CI/DI/MS pipe complete all as specified and directed by Engr-in-Charge. |
| 14 | All as per item No 13.00 above but of pipe size 150mm |
| 15 | All as per item No 13.00 above but of pipe size 200mm |
| 16 | All as per item No 13.00 above but of pipe size 250mm |
| 17 | S&F in replacement Cast iron pipe fittings such as of coller ,bends,tail piece, of size upto 350 mm dia incl gasket , nutbolts,handlel etc complete all as specified and directed by Engr-in-Charge. |
| 18 | M & L for laying in replacement of MS ERW Pipes of 250 mm dia size including all specials in any lengths & welding , cutting , bending etc complete laid in trenches/in duct/along wall/floor complete all as specified and directed by Engr-in-Charge. |
| 19 | M & L for laying in replacement of MS ERW Pipes of 200 mm dia size including all specials in any lengths & welding , cutting , bending etc complete laid in trenches/in duct/along wall/floor complete all as specified and directed by Engr-in-Charge. |
| 20 | All as per Item No 19.00 above but of size 150 mm |
| 21 | All as per Item No 19.00 above but of size 100 mm |
| 22 | All as per Item No 19.00 above but of size 80 mm |
| 23 | S&F in replacement of fire hydrant landing valve, SS, Single headed outlet of 63mm dia size including all fittings complete all as specified and directed by Engr-in-Charge. |
| 24 | S&F in replacement of fire hydrant landing valve, SS, Double headed outlet of 63mm dia size including all fittings all complete all as specified and directed by Engr-in-Charge. |
| 25 | S&F in replacement of Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle short complete all as specified and directed by Engr-in-Charge. |
| 26 | S&F in replacement of 63mm dia 15 mtr long hose confirming to IS 636:2018 type I mark, wheel mark approved, jacket made of 100% polyster for extra strength, complete with SS male and female coupling confirming to IS 903, heat and abrasion resistant, confirming to BS 6391 type 1, DIN 14811, UL 219 UL 19, EN 14540 (2004) complete all as specified and directed by Engr-in-Charge. |
| 27 | S&F in replacement of hose reel of 15/20mm dia and 30 mtrs long confirming to IS 5132 complete all as specified and directed by Engr-in-Charge. |
| 28 | S&F in replacement of Hose box Out door type made of MS sheet 800mm x 600mm x 250mm with double door with 4mm thick glasses and door frame made of MS sheet painted fire red outside and brilliant white inside complete all as specified and directed by Engr-in-charge. |
| 29 | S&F in replacement of Flanged stand post MS of 80mm dia 1.5m height including all necessary earth work, PCC work and necessary welding work for fixing complete all as specified and directed by Engr-in-Charge. |
| 30 | S&F fabricated MS bracket /supports for MS and CI Pipe line, made out of angle iron and flat iron including bolts, nuts, washers and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge. |
| 31 | M&L for cutting,clearing bushes/small plants and grass surrounding the E/M installations and removing the debris to a distance of 50m complete all as specified and directed by Engr-in-Charge. |
| 32 | M & L for removing the existing defective sluice valve spindle with check nut of any size and type from existing sluice valve of size upto 150 mm dia and replacement with new sluice valve spindle with check nut complete incluiding new nut,bolts and gland packing as per existing complete all as specified and directed by Engr-in-Charge. Note - (i) The contractor shall repair and refixing the spindle assembly within two days from the date of opening and making it functionable. (ii) Complaint will be notified to contractor on mobile phone at any time between 0800 hrs to 2200 hrs and defect,s will be rectified within two days after notification, failing which Rs 500/- per day will be recovered(ii) Contractor shall provide six month gurranty for all replaced spare parts of sluice valve. |
| 33 | All as per item No 32.00 above but size 200 to 350mm |
| 34 | M & L For preparation of the old painted surface of 80 to 300 mm bore CI/GI/MS Pipe and applying two coats of synthetic enamel paint in different colours as per colour code complete all as specified and directed by Engr-in-Charge. |
| 35 | M&L for disconnecting and taking down carefully Electric driven pumping set of capacity 30HP (motor and pump) from foundation, disconnecting suction and discharge water line for carrying out repair work of pump set, dismantling of pump set, cleaning, repair replacement of all unserviceable parts, reassembling complete pumping set, reinstalling , mounting and fixing on base channel on existing foundation and coupling properly to existing motor with proper balancing and alingment including recoupling of suction and discharge line, testing on full load for smooth functioning complete all as specified and directed by Engr-in-Charge.Note: (i) Rates including minor spares like gland, grease, nut bolts and major spares will be measured and paid separately and rate quoted shall be deemed to be included for fixing of new spares under these items. (ii) Contractor should visit site before quoting the rates. (iii) Cost of transportation shall be deemed to be included in the rate quoted for these items. (iv) While taking out pump for repairs , the contractor will make arrengement pluging suction and discharge line with dead flanges without extra cost, so that pumping of installation is not disturbed and there is no leakage of water. (v) The contractor shall repair and refix the pump set within 04 working days from the date of opening and making it functionable . |
| 36 | All as per item No 35.00 above but Pump Size 60/75 HP |
| 37 | All as per item No 35.00 above but Pump Size 270/313 HP |
| 38 | Supply only for Pressure gauge of size 8\\" dial 0-30 PSI, 0 - 14 Kgs rating with 15mm valve & connector |
| 39 | Supply only for MS shaft suitable for pump of capacity 30 HP |
| 40 | Supply only forImpeller bush brass suitable for pump of capacity 30 HP |
| 41 | Supply only for Brass Impeller suitable for pump of capacity 30 HP |
| 42 | Supply only for Gasket set suitable suitable for pump of capacity 30 HP |
| 43 | Supply only forGland bush /Shaft sleeve (As per sample) suitable for pump of capacity 30 HP |
| 44 | Supply only for MS Coupling suitable for pump of capacity 30 HP |
| 45 | Supply only for Bearing suitaible for pump of capacity 30 HP |
| 46 | Supply only forMS shaft suitable for pump of capacity 60/75 HP |
| 47 | Supply only for Impeller bush brass suitable for pump of capacity 60/75 HP |
| 48 | Supply only for Brass Impeller suitable for pump of capacity 60/75 HP |
| 49 | Supply only for Gasket set suitable suitable for pump of capacity 60/75 HP |
| 50 | Supply only for Gland bush /Shaft sleeve (As per sample) suitable for pump of capacity 60/75 HP |
| 51 | Supply only for MS Coupling suitable for pump of capacity 60/75 HP |
| 52 | Supply only for Bearing suitaible for pump of capacity 60/75 HP |
| 53 | Supply only forMS shaft suitable for pump of capacity 270/313 HP |
| 54 | Supply only for Impeller bush brass suitable for pump of capacity 270/313 HP |
| 55 | Supply only for Brass Impeller suitable for pump of capacity 270/313 HP |
| 56 | Supply only for Gasket set suitable suitable for pump of capacity 7270/313 HP |
| 57 | Supply only for Gland bush /Shaft sleeve (As per sample) suitable for pump of capacity 270/313 HP |
| 58 | Supply only for MS Coupling suitable for pump of capacity 270/313 HP |
| 59 | Supply only for Bearing suitaible for pump of capacity 270/313 HP |
| 60 | M&L for disconnection/dismantling of electric motor 3 Phase, 415 Volt, from installation & transporting to workshop for rewinding , taking out old unserviceable burnt winding and rewinding the same with super enamelled copper wire of same guage/size to get the same output of motor including material such as varnish, sleeves, leothariod paper etc and refixing the same in position with proper alignment, balancing and testing of capacities 30 HP complete all as specified and directed by Engr-in-Charge. |
| 61 | All as per item No. 60.00 above but Pump Size 60 HP |
| 62 | All as per item No 60.00 above but Pump Size 75 HP |
| 63 | M&L for taking down old unserviceable smoke detector any type and Supply, Installation, Testing & Commissioning of Analogue Addressable Optical smoke detector with standard base having capacity of min 125 detectors per loop. The detector must be polarity insensitive & smart addressable type all as per following specifications:- |
| 64 | Detector must have have insect protection facility for ants and flyes with extra metallic mesh pattern. |
| 65 | The detector must have non volatile memory to feed the installation date & site codes. It should be made up of ABS material (Flame retardant 94 V0 rated) & should melt above 200 degree C. The detectors must be openable for cleaning whenever required. |
| 66 | Note: i) Contractor should visit site before quoting the rate. ii) Devices should be purachase as per existing make iii) Contractor should provide skilled labour and T&P for execution of work. |
| 67 | M&L for taking down old unserviceable heat detector any type and Supply, Installation, Testing & Commissioning of Analogue Addressable Heat detector with standard base having capacity of min 125 detectors per loop all as per following specification:- |
| 68 | The detector must be polarity insesitive & smart addressable type. Mechanical Dipswitch or Rotary addressing is not allowed. Operating temperature transient -10°C to 85°C. The detector should have dual polling 360 degree viewable LED with 4 class approved response modes |
| 69 | The detector must have non volatile memory to feed the installation date & site codes.It should be made up of ABS material (Fire retardant 94 V0 rated) & should melt above 200 degree C. |
| 70 | Note: i) Contractor should visit site before quoting the rate. ii) Devices should be purachase as per existing make |
| 71 | M&L for taking down old unserviceable Indoor manual call point any type and Supply, Installation, Testing & Commissioning of Dust and Vermin proof analogue addressable Indoor Manual call point with hinged cover having enhance front reset mechanism with viewable LED all as per following specifications :- |
| 72 | The MCP must be made up ABS material (Flame retardant 94 V0 rated) & should melt above 200 degree C. |
| 73 | Note: i) Contractor should visit site before quoting the rate. ii) Panel and devices should be of same manufacturer |
| 74 | M&L for taking down old unserviceable sounder any type and Supply, installation and testing of addressable wall mounted Open Area Sounder complete all as specified and directed by Engr-in-Charge. Note: i) Contractor should visit site before quoting the rate. |
| 75 | M&L for taking down old unservicible Isolator any type and supply and fix new Isolator suitable for the system complete all as specified and directed by Engr-in-Charge. |
| 76 | B-L-A-N-K Please Enable Macros to View BoQ information |
| 77 | B-L-A-N-K Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysDec 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender