Tender For Repair/ Replacement Of Roof Sheet, Fasle Ceiling, Tiling Etc In H47 & H48 Of Area Account Under Ge West Agra
Tender Overview
Project Description
Tender for Repair/ Replacement Of Roof Sheet, Fasle Ceiling, Tiling Etc In H47 & H48 Of Area Account Under Ge West Agra
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 18-Nov-2026 | Corrigendum | Other | 04-Dec-2026 |
| 2 | 18-Nov-2026 | Corrigendum | BOQ | 04-Dec-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down cement or cement lime plaster of any discription on brick or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 2 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar ficings, dressed stone work and pre-cast concrete articles complete all as specified and directed. |
| 3 | M&L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed |
| 4 | M&L for 10-12mm thick ready mix repair plaster with high quality polymer additives and well graded sand and fillers which can be used for plastering (as per manufacturer instructions )over exterior surface of wall complete all as specified and directed. |
| 5 | M&L for 10-12mm thick ready mix repair plaster with high quality polymer additives and well graded sand and fillers which can be used for plastering (as per manufacturer instructions )over interior surface of wall complete all as specified and directed. |
| 6 | M&L Preparing newly plastered surfaces of walls and applying two coats of oil bound distemper over and including two or more coat wall care putty on wall to obtain smooth finish complete all as specified and directed. |
| 7 | M&L for complete removal of extg treatment of old plastered surfaces of wall and applying two coat of oil bound distemper with roller on old decorated wall surfaces over and including two or more coat wall care putty to obtain smooth finish complete all as specified and directed. |
| 8 | Material & Labour for preparing newly plastered surfaces of wall, applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm including putty over new surface of wall complete all as specified and directed. |
| 9 | Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm including putty complete removal of existing treatment old wall surface complete all as specified and directed. |
| 10 | M&L Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings .complete all as specified (Paymentfor providing grooves shall be made separately). |
| 11 | M&L Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge |
| 12 | Dismantling asbestos cement (corrugated semi corrugated etc ) sheets in roof covering above 12 to 15 m height complete all as specified and directed. |
| 13 | S&F for pre- painted galvatume aluminum zinc coating GI based corrugated steelsheet 0.50mm thick of any colour having tensilestrength of 550 Mpa as in roof covering/cladding towall, fixed with selftapping screws up to a height of 12 to 15m complete all as specified and directed |
| 14 | S& F for pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 15 | Dismantling timber scantlings 40 sq. cm and over in section, in any position |
| 16 | S & F Mild steel Angles, bars, flats etc., as in supports for stiffening of fencing, wall ties, hold fasts, clamps, plain angle cleats for securing purlins and similar small articles confirming toFe-290 Gde-E-165 including for drilling the members for site, fitting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats connections complete all as specified and directed. |
| 17 | S&F Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to Fe-290 grade E-165 including for drilling the members for site, Fabrication, fitting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting connections complete all as specified and directed. |
| 18 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete , including taking out, cleaning of flase ceiling and handling removing to store or stacking for reuse all as specified and directed. |
| 19 | S&F anodised aluminium/GI snap grid frame work for false ceiling all as specified of grid 605 x 605 including GI hangers of suitable dia and fixed to purlin/rafters as specified. |
| 20 | S&F 4 mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws in ceiling complete all as specified and directed. |
| 21 | S&F Louvers Prelam PVC wall panelling profiles with integrated skin of any shape/ size as per directed by enge-in-charge manufactured by an ISO 9001-2015 certified compony, having tounge and groove design with inter locking facility, will be fixed in perpendiculordirection at the face wallusing 8x38mm steel screwat every 450mm centre to centre covering to avoide leakage through joints.the profile are to b e jointed and finished so as to have a flush lock which includes filling and finishing with joined compound (Adhesive) between brick wall & wall linninginclude L/T & C type bedding all as per manufacturers instruction and directed by Engieer -In Charge, complete all as specified and directed . |
| 22 | Demolition of cement concrete (unreinforced) in gd floor and paving n.exc 15 cm thickness below or above the gd level. |
| 23 | M&L 25 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in sub base of flooring finished even and fair without using extra cement complete all as specified & directed. |
| 24 | M & L for Vitrified tiles 7-8 mm thick light shade (square/rectangular) area of each tile exceeding 0.42 sqm but n exc 1.00sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match in floor over and including 15mm thick cement screed bed of CM (1:6) complete all as specified & directed. |
| 25 | M&L Granite slab 18 to 20 mm thick in steps, pillars, window cills, pillars, window cills, cooking platforms and like laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rounding edges of stone slab one edge and including 15mm thick screed bed or bedding layer of cment mortar (1:6) complete all as specified and as directed. |
| 26 | M&L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings, kerbs, benching and the like, including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete. |
| 27 | Taking down Chowkhats or frames not exc. 1.5 sq. m but (without taking off shutters from the frames each complete all as specified and directed. |
| 28 | Taking down Chowkhats orframes exc. 1.5 sq. m but n. exe 4 sqm (without taking off shutters from the frames each complete all as specified and directed. |
| 29 | M&L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45X85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length and hinges complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be madeetc complete all as specified and directed. |
| 30 | S&F for factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and including fixing with 100mm long stainless steel butt hinges -04Nos with necessary full body threaded star headed counter sunk S.S screws, complete all as per specified and directed. |
| 31 | S&F 200 mm long stainless steel tower bolt of extruded section complete all as specified & directed. |
| 32 | S&F Stainless steel , 250 mm sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 33 | S&F 150 mm long stainless steel handle cast type complete all as specified and directed. |
| 34 | S & F in repair cast iron Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed. |
| 35 | S&F aluminium anodised grill (DG 104) 10mm x 5 mm thick on Deco grill or equivalent fixed with 'F' section approved make complete all as specified and directed. |
| 36 | S&F powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc (minimum thickness of powder coating 50 micron) weighing 0.55 Kg/M or frame size as per ground requirement complete all as specified |
| 37 | M&L for Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m or as per site requirement including 4mm thick sheet glass , necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specifiedcomplete all as specified and directed. |
| 38 | S&F in repairs Stainless steel drapery rods, 20mm internal diameter including decorative type brackets and PVC curtain rings 8 Nos per RM including fixing arrangement with drilling holes in walls, brackets etc complete all as specified and directed. |
| 39 | M&L for PCC 1:3:6 C-2 (using 20mm graded crushed stone aggregate) as in plinth protection, path ( 75 mm thick ) finished cement concrete surface even and smooth without nusing extra cement all as specified. |
| 40 | M&L fo mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 |
| 41 | M& L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along the internal/external wall and wooden Cup board,shelves,etc.wooden area should drill by 6 mm bit,Gap between two holes is 30 cm to 45 cm internal/external wall skirting level should drill by 8/10/12 mm bit,gap between two holes is 45 cm to 60 cm.filling the holes by 100 ml to 150 ml dilution of chemical emulsion in two stages 3 stage close the holes by white cement and finsihes with existing surfaces.The ATT chemical should be odorless and mixed formulation should be injected at the rate of 5 ltr per sqm.The ATT chemical should contains.(i) Byfinthrin 20 % EC(Smell Chemical)(ii)CHLORPYRIPHOS 20 % EC (Smell Chemical)(iii) Imidacloprid 30.5 % SC (Odor less Chemical)The work pertaining to ATT shall be executed from authorized applicator through manufacturer of which the materials is proposed to be used by the contractor and approved by GE.(a) 02 years guarantee of painting work will be admissible after date of completion and 10% amount will be reserve against ATT work after date of completion for the 02 years. |
| 42 | Taking down carefully copper/aluminium point wiring on batten/ PVC conduit (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, including removal and making good disturbed surfaces of walls, ceilings etc by cement/ colour /plaster to match with the existing location spot complete all as specified & directed by Engr-in -Charge. |
| 43 | M&L for concealed point wiring for one light point/fan point/bell point controlled by one switch (using red, black and green colour coding) complete with 1.5 sqmm unsheathed and multi stranded copper conductor single core FRLSH PVC insulated, 1100 volts PVC insulated unsheathed cable with proper colour coding drawn in through and including PVC concealed conduit not less than 25 mm dia ( medium duty, ISI marked) with all fittings and accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc.,including pressed steel powder coated sunken terminal box suitable for modular switch socket concealed in wall, suitable for fixing modular switches/ socket/ regulator etc, including provn of 1.5 sqmm single core FRLSH PVC insulated multi standed copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ ceiling/ floors etc by using CM (1:3) complete all as specified & directed by Engr-in -Charge. NOTE:- Modular switches/ socket/ regulator shall be measured and paid separately under appropriate item |
| 44 | All as per item No-43 here in before but One socket outlet 5/6 Amps on independent switch board controlled by one switch complete it with 2.5sqmm unsheathed and multistranded copper conductor single core, complete all as specified & directed by Engr-in -Charge. |
| 45 | All as per item No-43 here in before but One socket outlet 5/6 Amps controlled by one switch on same board with other switches complete it with 2.5 sqmm unsheathed and multistranded copper conductor single core, complete all as specified & directed by Engr-in -Charge. |
| 46 | All as per item No-43 here in before but using 2.5 sqmm PVC FRLS insulated stranded copper conductor cable and for one socket out let 3/6 pin, 15/16 Amps controlled by one 1 way switch on independent board complete all as specified & directed. Please Enable Macros to View BoQ information |
| 47 | All as per item No-43 here in before but using 2.5 sqmm PVC FRLS insulated stranded copper conductor cable and for one socket out let 3/6 pin, 15/16 Amps controlled by one 1 way switch on independent board complete all as specified & directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 13 daysCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 13 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender